finder 72.A1 Float Level Switch Instructions
- June 9, 2024
- finder
Table of Contents
72.A1 Float Level Switch
Instructions
72.A1 Float Level Switch
72.A1.1.000.xx01 = H05 RN-F
72.A1.1.000.xx02 = WRAS NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON
RESPECT OF THE FOLLOWING POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF
THE WARANTY OF THE PRODUCT
Before any operation on the float remember to disconnect the power supply from
the main power.
Check that the maximum load power does not exceed the float’s electrical
values.
In case of cable damage by the final user or installer, the float must be
replaced.
Do not make any joint on the cable of the float switch, as immersion of such
joints could cause short circuits or electrical shocks.
TECHNICAL FEATURES
AC: Max 10 A (250 V) resistive load – 8 A (250 V) inductive load
Operating temperature: max. +50°C (+40°C ACS)
Wire gauge: 7 mm
Max working pressure: 10 BAR
Protection Grade: IP 68
ACTIVATION ANGLE: 30°
TERMINAL CONNECTIONS
The upstream circuit must protect the electric wires from the overcurrent.
WARNING
Lack of protection shall null and void the warrany in the event the float
breaks.
-
Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when the float is up.
Note: the blue wire must be insulated -
Filling: (Fig.3) when brown and blue wires are used, the circuit closes when float is down and opens when the float is up.
Note: the black wire must be insulated
100% MADE IN ITALY
IB72A1 – 01/23 – Finder S.p.A. con unico socio – 10040 ALMESE (TO) –
ITALY
Documents / Resources
|
finder 72.A1 Float Level
Switch
[pdf] Instructions
72.A1, 72.A1 Float Level Switch, Float Level Switch, Level Switch
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>