universal douglays LRL12-15L840-750C 2 Feet LED Lensed Module User Guide

June 3, 2024
universal douglays

universal douglays LRL12-15L840-750C 2 Feet LED Lensed Module

universal douglays LRL12-15L840-750C 2 Feet LED Lensed
Module

Description

2’ LED Lensed Module

  • Simple and easy installation
  • Long life with high efficacy
  • Diffuser lens provides broad, even light distribution
  • Integrated heatheatsink for cool operation
  • ClassClass2rating simplifies wiring

Lumen Performance


Catalog Number

| Nominal|

CRI

Current (Amps)| Initial

Lumens (1)

| Vf (2)

(Volts)

| Power (Watts)| Lm/W
LRL12-15L840-750C| 0.350| 1,575| 36| 12.5| 126| > 82
0.525| 2,250| 37| 19.8| 114

  1.  MID Flux Bin Values are shown for CCT of 4000K. Tolerance of ±6.5% at 25°C
  2. Vf is at Tc of 25°C with max tolerance of +/- 5%.

General Performance Specifications

  • Lumen Maintenance : L85 > 60Khrs (reported) L70 > 140Khrs (calculated) @ I= 525mA, tamb=40°C
  • Color Consistency: <3 SDCM (3500K, 4000K) <4 SDCM (5000K)

Mechanical Dimensions

  • Length: 21.45”
  • Width 0.8”
  • Height: 1.24”
  • Weight: 0.7 lbs.
  • Lead Length: Red & Blue 24”

Ordering Information

Part Number CCT Lumen Multiplier
LRL12‐15L835‐525C10C 3500K 96.7%
LRL12‐15L840‐525C10C 4000K 100.0%
LRL12‐15L850‐525C10C 5000K 104.1%

Application

  • Min. Ambient Operating Temp.: -22°F, -30°C
  • Max. Ambient Operating Temp.: 140°F 60°C
  • Maximum Current rating of 0.525 Amps Regulatory
  • UL8750
  •  CSA250.13-14
  • RoHS Compliant

Notes:

  • Performance data taken at Tamb = 25°C
  • Power consumption and photometric performance are typical values
  • Lumen maintenance value is based on LM80 testing and TM-21 calculation projections.

universal douglays LRL12-15L840-750C 2 Feet LED Lensed Module
1

Installation & Assembly Guidelines

  • This module is to be mounted using mounting slots and fasteners. The aluminum frame should be grounded or mounted to a grounded metal surface.
  • Modules may be connected in parallel to split current from the LED driver.

Dimensions

24” 20AWG Stranded Copper Leads

universal douglays LRL12-15L840-750C 2 Feet LED Lensed Module
2

Application Notes

  1. The standard base model version of this module without Conformal Coating is designed for indoor fixtures in dry applications. Damage caused by corrosion due to moisture, condensation and other harmful elements, is not covered by the warranty.

Conditions of Acceptability

  1. The LED modules are intended for connection to a Class 2, constant current source of supply. The connection of the LED arrays to a source of supply other than class 2, the suitability must be determined in the end use product investigation.
  2. The LED modules shall be installed in compliance with the mounting, spacing, casualty, and the segregation requirements applicable to the ultimate application.
  3. The LED modules were subjected to the Normal Temperature Test in a 40°C Ambient.
    Model| Maximum Input

Current

| Location

Center of the PCB

| Measured °C| Limit

°C

---|---|---|---|---

  • LRL12-15Lyzz- aaaC

|

600 mA

| Between 24th and

25th LED

| 67.3| 105
Center – Bottom

Heat Sink

| 63.6| —
4. The LED Array modules are suitable for “DRY” locations. The use in other than dry locations shall be evaluated to the end use application. 5.  The array modules may be marked with any voltage and current rating that do not exceed the maximum ratings specifies in the ELECTRICAL RATINGS. 6. Suitability of input connections to the LED module to be determined in
the end use product.