hoymiles HYS-3.0LV-EUG1 Hybrid Inverter Installation Guide

June 3, 2024
hoymiles

HYS-3.0LV-EUG1 Hybrid Inverter
Installation Guidehoymiles HYS-3.0LV-EUG1 Hybrid
Inverter

HYS-3.0LV-EUG1 HYS-3.6LV-EUG1
HYS-4.6LV-EUG1 HYS-5.0LV-EUG1
HYS-6.0LV-EUG1

General Declaration

  • The information in this quick installation guide is subject to change due to product updates or other reasons.
  • This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions here are for guidance only.
  • Before installations, read through the quick installation guide and the user manual to learn about the product and the precautions.
  • All installations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations.
  • Check the deliverables for correct model, complete contents, and intact appearance. Contact the manufacturer if any damage is found or any component is missing.
  • Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strips when touching electron devices to protect the inverter from damage. The manufacturer shall not be liable for any damage caused by static electricity.
  • Strictly follow the installation, operation, and configuration instructions in this guide and user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions.
  • All cables in this article are copper cables.

Packing List

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 1

Mounting the Inverter

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 4

Wiring Diagram

Wiring diagram for countries such as Australia, New Zealand, South Africa, etc.
Please follow local wiring regulations.

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 5

Model 1 2 3 4 5 6 7
HYS-3.0LV-EUG1 100A/60V DC Breaker 20A/230V AC Breaker 40A/230V AC Breaker
Depends on Loads Main
Breaker 30mA RCD
HYS-3.6LV-EUG1 125A/60V DC Breaker 20A/230V AC Breaker 40A/230V AC Breaker
HYS-4.6LV-EUG1 125A/60V DC Breaker 25A/230V AC Breaker 40A/230V AC Breaker
HYS-5.0LV-EUG1 125A/60V DC Breaker 32A/230V AC Breaker 40A/230V AC Breaker
HYS-6.0LV-EUG1 125A/60V DC Breaker 40A/230V AC Breaker 40A/230V AC Breaker

Note:

  • If the battery has integrated a readily accessible internal DC breaker, then no additional ① DC breaker is required.
  • ⑥⑦ 30mA RCD, please comply with local regulations for the system installation.

Wiring diagram for other countries, please follow local wiring regulations.

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 6

Model 1 2 3 4 5 6 7
HYS-3.01V-EUG1 100A/60V DC Breaker 20A/230V AC Breaker 40A/230V AC Breaker
Depends on Loads Main
Breaker 30mA RCD
HYS-3.6LV-EUG1 125A/60V DC Breaker 20A/230V AC Breaker 40A/230V AC Breaker
HYS-4.6LV-EUG1 125A/60V DC Breaker 25A/230V AC Breaker 40A/230V AC Breaker
HYS-5.0LV-EUG1 125A/60V DC Breaker 32A/230V AC Breaker 40A/230V AC Breaker
HYS-6.0LV-EUG1 125A/60V DC Breaker 40A/230V AC Breaker 40A/230V AC Breaker

Note:

  • If the battery has integrated a readily accessible internal DC breaker, then no additional ① DC breaker is required.
  • The use of ⑥⑦ 30mA RCD is recommended but not mandatory, please comply with local regulations for the system installation.

Electrical Connection

Step 1 Grounding Protection Wire

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 7

Step 2 Grid (Same wirings for GEN connector, leave it alone if not used)

Step 3 EPS

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 9

Step 4 PV

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 10

Step 5 Battery

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 11

Step 6 Signal Communication (Connection of communication box is mandatory)

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 12

Label Description
Meter (485A, 485B) For the Smart Meter.
BMS (NTC+, NTC-, CANH, CANL, 485A, 485B) For Li-ion battery communication via

CAN or RS485. For lead-acid battery temperature is monitored via a sensor through NTC+ and NTC-.
DRM (D1/5, D2/6, D3/7, D4/8, REF, COM)| For external  Demand Response Enabling Device.
DI (IN-, IN+)| Dry-contact input of external bypass contactor.
Parallel (DI IN+, DI IN-,CANH, CANL, 485A_1, 485B_1, 485A_2, 485B_2)| For parallel operation.
120 Ohm (ON, OFF)| 120 Ohm termination resistor for parallel operation.
DO1 (NO1, COM1)| Dry-contact output. The DO1 will control the bypass contactor under certain logic.
DO2 (NO2, COM2)| Dry-contact output. The DO2 can be set to one of the functions as follows: Earth Fault Alarm, Load Control, Backup Load Smart Control, and Generator Control.

RJ45 Terminal Connection (METER, BMS)

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 13

Step 7 Data Transfer Stick (DTS)
WIFI Connection

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 14

Step 7 Data Transfer Stick (DTS)
Ether Connection

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 15

DTS Online Setting

hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - qr codehttp://m.hoymiles.com/download_installer.html

  1. Search “Homilies” in the App Store (iOS) or the Play Store (Android), or scan the QR code to download the Hoymiles Installer App.

  2. Open the app and log in with your installer account and password. For new Hoymiles installers, please apply for an installer account from your distributor in advance.

  3. Use the App to connect to the DTS.
    (a) Open the Installer App on your smartphone/tablet and log in. Click on “O&M” at the bottom of the page then click on “Network Configuration”.
    hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 16(b) Select the DTS’s wireless network and click Connect. (The network name of the DTS consists of DTS and product serial number, and the default password is ESS12345)hoymiles HYS-3.0LV-EUG1 Hybrid Inverter -
Figure 17hoymiles HYS-3.0LV-EUG1 Hybrid Inverter -
Figure 18

  4. Network configuration.
    (a) Upon successful connection, click on “Network Configuration” again and access the Network Configuration page.
    (b) Select the router Wi-Fi and enter the password.
    (c) Click on “Send to DTU”.
    hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 195. Check the DTS indicator for a solid blue light, which signifies a successful connection.
    The network configuration takes about 1 minute, please be patient. If the network is not connected, please check the internet as instructed.
    hoymiles HYS-3.0LV-EUG1 Hybrid Inverter - Figure 20

User Manual in the QR code or at

www.hoymiles.com/resources/download/

Hoymiles Power Electronics Inc.
Add: No.18 Kangjing Road, Hangzhou 310015, P.R. China
Tel: +86 571 2805 6101
Email: service@hoymiles.com
support@hoymiles.com
www.hoymiles.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals