INTRODUCTION

  1. Thank you for having chosen a 200T-RGBW LED Zoom Fresnel Light, please read this user manual carefully before you initially start-up.
  2. This product is allowed to be operated with an alternating voltage of AC90-240V 50/60Hz and designed for indoor use only.

Description of the fixture

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 1

  1. Fixation screws
  2. LCD Display
  3. Function selection knob
  4. Power IN
  5. Power Out
  6. DMX Out
  7. DMX IN
  8. Installation stand
  9. Insulate handle

Dimensions

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 2

Wiring Diagram

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 3

Control Board

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 4

  • Adjust the key setting function on the control panel
  • Press“MENU”—>Display first -level menu—>
    Press“Enter”—>Display second-level menu—>
    Press“Down”&“Up”to adjust relevant function->
    Press“Enter”and“MENU”to quit current menu
    Press“Enter”—> To next first-level menu.

Operation

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 5

LCD display Function setting
DMX512 MODE setting the DMX starting address from 001- 512
Dimmer R- [MODE] setting  the  red color brightness   000- 255
Dimmer G- [MODE] setting  the  green color brightness   000- 255
Dimmer B- [MODE] setting  the  blue color brightness   000- 255
Dimmer W- [MODE] setting  the  white color brightness   000- 255
Col_Temp [MODE] setting the CCT 1800K- 9928K
Dimming [MODE] Dimming 000- 255
Strobe [MODE] setting  the strobe speed      000- 012
Fade [MODE] setting  the fade speed      000- 012
Auto [MODE] setting  the auto speed      000- 012
CCS [MODE] correcting function     ON- OFF
Channel [MODE] setting DMX channels 11CH-6CH
PWM Frequency [MODE] setting PWM frequency    1200Hz-20000Hz

Master/ Slave Setting

  1. Set the mast fixture to Dimmer or Strobe
  2. Set each slave fixture to the same DMX001( As show below)

Illumination Diagram

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 6

DMX Channels

(This fixture has two DMX channel mode options)
11 Channels Function

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 7

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 11

HSIC Channels Mode

SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light 8

HSIC Channels Function

channel 1- Hue 000 – 255 levels RGBW color mixing
channel 2- Saturation 000- 255 levels saturation adjustable
channel 3- Intensity 000 – 255 levels master dimming
channel 4- Intensity fine 000 – 255 levels dimmer fine
channel 5- CCT 000 – 255 levels linear dimming,CCT1800K- 10000K
channel 6- STROBE 000 – 009 levels without function

010 – 255 levels strobe function

Note: Color Temperature (CCT) Ratio

DMX levels CCT DATA DMX levels CCT DATA
000↔006 1800 K↔2000 K 131↔137 6000 K↔6200 K
006↔012 2000 K↔2200 K 137↔144 6200 K↔6400 K
012↔018 2200 K↔2400 K 144↔150 6400 K↔6600 K
018↔024 2400 K↔2600 K 150↔156 6600 K↔6800 K
024↔030 2600 K↔2800 K 156↔162 6800 K↔7000 K
030↔036 2800 K↔3000 K 162↔169 7000 K↔7200 K
036↔044 3000 K↔3200 K 169↔175 7200 K↔7400 K
044↔050 3200 K↔3400 K 175↔181 7400 K↔7600 K
050↔056 3400 K↔3600 K 181↔187 7600 K↔7800 K
056↔062 3600 K↔3800 K 187↔194 7800 K↔8000 K
062↔069 3800 K↔4000 K 194↔200 8000 K↔8200 K
069↔075 4000 K↔4200 K 200↔206 8200 K↔8400 K
075↔081 4200 K↔4400 K 206↔212 8400 K↔8600 K
081↔087 4400 K↔4600 K 212↔219 8600 K↔8800 K
087↔094 4600 K↔4800 K 219↔225 8800 K↔9000 K
094↔100 4800 K↔5000 K 225↔231 9000 K↔9200 K
100↔106 5000 K↔5200 K 231↔237 9200 K↔9400 K
106↔112 5200 K↔5400 K 237↔244 9400 K↔9600 K
112↔119 5400 K↔5600 K 244↔250 9600 K↔9800 K
119↔125 5600 K↔5800 K 250↔255 9800 K↔10000 K
125↔131 5800 K↔6000 K  

Technical Specifications

LED Source COB 200W LED 4 IN 1, RGBW
Beam Angle Beam angle 25-50° with hight- efficiency optical system
Control 1.DMX512 2. RDM 3.Master/ Slave Operation
DMX Channels 11CH/6CH
Connection PowerCON IN & OUT; 3- Pin DMX In& Out(5 – Pin DMX available)
Voltage Electronic full- range AC 100-240V 50/60Hz
Working Temperature Indoor,IP20.

– 20℃- 40℃(- 4°F- 104°F)
Power

Consumption

| 180W
Dimensions

( LxWxH)

| 58.7X26.4X19.4cm
Weight| 7.25Kg

Please Note

  1. Dimming, Brightness Function
    Before using the fixture,you should check whether (Dimming, brightness function) is turned on , As shown in figure①;the factory setting is on .This function should be
    checked when the fixture does not turn on when the lamp is turned on.It is not affected by this function

  2. 《ColorTemp
    Master/Slave Mode, Colortemp(CCT)adjustable from 1800K to 9928K As show below①②,factory setting as below 3.
    ( If the Colortemp function is enabled, the R G B W function cannot be used alone.
    If you want to use the RGBW function alone, you must turn off Colortemp).SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light
10

  3. CCS、Color Calibration System
    If more than two fixtures have different output colors, check that the whether correcting settings for each fixture are consistent, as show below ①,Factory setting:ON.SHOWLIGHT SL-200T-RGBW LED Zoom Fresnel Light
12

  4. Channels Function
    This fixture has 6-channel mode and 11-channel mode selection. In DMX512 mode, If more than two fixtures have different settings, check whether the channel functions
    are consistent. as show below ①②,Factory setting[11CH].SHOWLIGHT SL-200T-
RGBW LED Zoom Fresnel Light 13

  5. PWM Function
    In DMX、Master/Slave mode,If the dimming smoothness and color output are different on more than two fixtures, check that whether the PWM settings are consistent. as show below ①②,Factory setting[1200Hz].SHOWLIGHT SL-200T-RGBW
LED Zoom Fresnel Light 14

  6. RDM Function
    If use the RDM function, that must use the console to search each fixture and change the fixture address code in the DMX 512 mode.
    Identification Code: each fixture has an identification code as show below① , the identification code of each fixture is different , Please check he fixture label.

  7. DMX512 Function
    In D M X mode, the LED display is normal when there is no DMX5 1 2 signal input, and the LED display is lights up when the DMX5 1 2 signal is input