PHILIPS BY100P CoreLine Highbay Value Ceiling Light Instructions

June 4, 2024
Philips

PHILIPS BY100P CoreLine Highbay Value Ceiling Light Instructions
PHILIPS BY100P CoreLine Highbay Value Ceiling Light

Package Content

Package Content

Description

| System lumen (lm)| CCT (K)| Prmax (W)| Dimensions in mm
D           H| | light source energy efficiency class|

Reflector Siz e

---|---|---|---|---|---|---|---

BY100P LED100S/840 PSU WB

| 10500| | 77| 278| 89| 1.9| D| S
BY101P LED200S/840 PSU WB| 20500| 4000| 154| 305| 99| 2.3| D|

S

BY102P LED260S/840 PSU WB

| 25500| | 187| 358| 99| 3| D| M

Dimensions

Product Dimensions

Optional: Reflector

product Dimensions

12NC reflector

| EOC| Description| Reflector Size| d|

h

---|---|---|---|---|---

9114 016 77107

| 871951454583099| BY101Z ALU| S| 474| 141
9114 016 77207| 871951454584799| BY102Z ALU| M| 543|

153

Optional: Mounting Accessories Bracket

12NC

| EOC|

Description

---|---|---

9114 016 76807

| 871951454602899|

BY100Z BR L215

product Dimensions

Hook

Product Dimensions

Hook Mounting

Hook Mounting
Optional: Pipe Mounting

Optional Pipe Mounting

Optional: Bracket Mounting

Optional Bracket Mounting

Safety string mounting

Safety string mounting

The hole (φ5 ) is for a safety string
Safety string has to be mounted for this luminaire.
Safety string is not provided by Signify, need to be prepared by use

Optional: Reflector Mounting

Optional: Reflector Mounting

Remove 4 pcs nylon screws, use 4pcs M4x10 Screw & D4 Cushion to fix reflector.

  1. Attention: Reflector installation must be completed before steps of luminaire fixing and power cable connection .
  2. Please protect the diffuser during the steps of reflector installation.
Connect Power Cable

Connection Cable

Inrush current

Inrush current

BY100P                 BY101P                       BY102P

Electrical characteristics

Imax (A)

| 40| 42| 54
Tref (µs)| 600| 650|

750

MCB                                                 Maximum number of luminaire

B-16 A| 8| 6|

6

C-16 A

| 13| 8|

8

  • The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements .

  • Do not switch the luminaire on before completing installation.

  • The height between luminous surface and ground suggested be more than 5m; and the height between bottom of luminaire and mounting surface must be more than 0.3m.

  • If customer require the luminous surface levelness < 1°, pipe mounting method is recommended, and suggest to use gradienter to precisely measure and adjust.

  • If the external flexible cable or cord of this luminaire is damaged. It shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

  • The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

  • The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.

  • Luminaire don’t have any evaluation on additional protective measures to prevent luminaire from high-altitude falling and windproof structure, therefore it can’t be used as flood and tunnel luminaire.

  • Not suitable for use in harsh vibration and often causing vibration or swinging environment. Also not suitable for area prone to hurricane and extreme winds.

  • Installer needs to be arrange the Chain / Pipe for mounting. The default product is supplied with a mounting hook.
    Do not stare at the operating light source.

  • For Indoor use only. This product is not suitable for cold storage areas lower than -20⁰C or areas where obvious temperature gradients are present, such as ventilation opening, door, etc.

Disconnect before servicing

Luminaire has basic insulation between Low Voltage supply and control conductors.

Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime

This product contains a light source of energy efficiency class: see table or label.

Symbols




References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals