Technical data
Continuous operating temperature | -40 °C …. + 85 °C |
---|---|
Rated voltage | 1500 V DC |
Rated current | 30 A |
Protection degree mated | IP65 /IP68 (1 m, 1 h) |
Protection degree unmated | IP2x |
Protection class | II |
Wire cross section | 4 mm² … 6 mm² |
Cable diameter | 5.4 – 7.6 mm |
Overvoltage category | III |
Polution degree inside / outside | 2 / 3 |
Clearance and creepage distance acc. | DIN EN 60664-1:2007 |
Power loss / Contact resistance acc. | IEC 62852:2014+Amd.1:2020 |
Certified | gepri.ift nach / tested acc. to IEC 62852:2014+Amd.1:2020 |
Rated impulse voltage | 16 kV |
Connection technologie | SNAP IN |
Installation temperature | +10 °C … +40 °C |
Upper limitin temperature | +115 °C |
Safety notice
- Prior to work the device must be disconnected from the power supply and potected against re-connection and it must be de-energized.
- This product may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this filed of application.
Intended use
The connector is intended for use only in photovoltaic systems within the
specifications described.
The connector can only be used for connections within one string. In
applications up to 1,500 V the connector may only be used together with cables
that are released for this purpose. Any other usage can lead to serious
personal injury and damage to property. The observance of this installation
instructions is part of the intended use.
Ambient conditions
The components shall be clean during installation. If neccessary please use
the dust cap (see accessories) to protect it from dirt.
- The installed PV-stick shall not be located directly on the roof panel.
- The installed PV-stick shall not be exposed to permanent mechanical load. All cables shall be fixed using cable ties or any kind of strain relief.
Connectable PV cables
The PV cables to be connected must meet the following requirements:
- Appoval according to IEC 62930:2017
- Tinned copper conductor class 5 according to IEC 60228:2005
- Sheathing material comlpying with material group II according to IEC 60664-1:2020
Order data
| Buchse / Female| Stift / Male
---|---|---
|
VPE
Packaging unit| Order No.| Order No.
10| 1303450000| 1303490000
50| 1303460000| 1303500000
200| 1303470000| 1303510000
PV-Stick Set| 1 x Female and male 1422030000
Accessories| | Order No.
---|---|---
Female housing box version| | 1530630000
Female contact| | 1530670000
Male housing box version| | 1530640000
Male contact| | 1530680000
Dust protection cap for female and male| | 1254870000
Locking clip| | 1328150000
multi-stripax PV Stripping and cutting tool| | 1190490000
MULTITOOL PV SET| | 2771530000
Installing the PV-Stick
Preparing the cable
Inserting the cable
Connecting the cable
Replacing the PV-Stick
| DANGER
---|---
Hazardous electrical voltage!
Do not disconnect under load!
Make sure that the device is disconnected from the power supply and potected
against re-connection and that it
is de-energized, before you unlink the PV-Stick.
| The PV-Stick cannot be re-used.
---|---
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-29 20 83
www.weidmueller.com
1422020000/10/09.2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>