Streetworks ARCH1 Archeon Contemporary User Guide
- June 1, 2024
- Streetworks
Table of Contents
- Streetworks ARCH1 Archeon Contemporary
- Product Usage Instructions
- Product Certifications & Features
- Product Specifications
- Dimensional Details
- Ordering Information
- House Side Shield Details
- Mounting Details
- Installation Overview
- Energy and Performance Data
- Optical Distributions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Streetworks ARCH1 Archeon Contemporary
Product Specifications
- Product Name: Archeon Contemporary – ARCH1
- Type: Roadway Luminaire
- Interactive Menu: Light ARchitectTM
- Product Features:
- photocells
- Networked Lighting Control (NLC) modules
- Dimensions :
- Height: 15.75 in [400.3mm]
- Width: 4.5 in [115.9mm]
- Depth: 7.25 in [183.8mm]
Product Usage Instructions
-
Mounting Details
Press in the designated locations to install the luminaire. -
Optional Arms
Choose between a 15 straight arm or an adjustable slip fitter offset arm for mounting the luminaire. -
Photocontrol
The luminaire comes with factory-installed sensors for dusk-to-dawn lighting. The occupancy sensor is connected to a dimming driver for energy efficiency. -
Controls and Accessories
Refer to the ordering information for available controls and accessories that can be added separately for enhanced functionality.
FAQ
-
What should I do if the luminaire is not functioning properly?
If you encounter any issues with the product’s functionality, please refer to our customer support team for assistance. -
Can I use different mounting options for this luminaire?
Yes, you can choose between the provided optional arms for mounting the luminaire based on your specific requirements.
Streetworks
Archeon Contemporary – ARCH1
Roadway Luminaire
Product Certifications & Features
Interactive Menu
- Ordering Information page 2
- Accessory & Mounting Details page 4
- Installation Overview page 4
- Optical Distributions page 5
- Energy and Performance Data page 5
Product Specifications
OPTICAL
- 5 patented AccuLED high efficiency roadway and area optical distributions
- 7 color temperature options
- 70 CRI: 2200K, 2700K, 3000K, 4000K, 5000K
- Amber: wildlife-friendly and observatory applications
- Optics are IP66 enclosure rated
- 2 versions of field-installable shielding for superior spill light control
- Single-piece snap-on square shields
- Multiple-piece configurable vertical perimeter shielding
- IDA certified for 3000K, 2700K, 2200K CCTs
ELECTRICAL
- 120-277V, 240-480V, 347V, and 480V; 50/60Hz
- Standard 0-10V dimming
- 10kV and 20kV surge protection options in common- and differential- mode versions
- -40ºC to 40ºC ambient temperature operating range
- Standard 3-position terminal block
WARRANTY
Five-year limited warranty. Consult website for details.
www.cooperlightng.com/legal
PHYSICAL CHARACTERISTICS
- Heavy duty die-cast aluminum housing and door
- Tool-less entry for easy maintenance
- 3G vibration rating (ANSI C136.31)
- Standard CLS lineman-friendly features
- Tool-less entry
- 3-position terminal block
- Housing finished in 5-stage super TGIC polyester powder coat paint, 2.5 mil nominal thickness
- 5 standard color options, plus a wide range of customer colors (consult your Cooper Lighting representative for custom color options)
- Two-bolt slipfitter with cast-in pipe stop and 2.5º leveling steps
- Stamped metal birdguard seals entry for 1-1/4” to 2” (1-5/8” to 2-3/8” OD) mounting arms
- Approximate net weight: 7 lbs
- EPA: 0.35
CONTROLS
- Standard ANSI C136.10 7-pin receptacle for photocells Networked Lighting Control (NLC) modules
- Optional Field Adjustable Dimming Control Module (FADC)
- Enables manual adjustment of power consumption and lumen output. Factory pre-set to highest output level for option selected
- Allows a single fixture SKU to cover multiple field applications with manual adjustment at installation
- Optional 4-pin Zhaga Book 18 receptacle for integration of onboard sensors with DALI- and D4i-enabled drivers
- Fully compatible with Cooper Lighting Solutions Trellix Infrastructure UNB (Ultra Narrow Band) and cellular networked lighting controls platforms.
- Automatic, wireless collection of luminaire performance and status data
- Allows asset location for inventory management of large-scale installations
Dimensional Details
Streetworks Archeon Contemporary – ARCH1
Ordering Information
SAMPLE ORDER NUMBER: ARCH1-30-730-U-T2R-AP-10MSP
Product Family| Wattage Bucket| Color Temperature|
Voltage| Distribution| Mounting| Finish
---|---|---|---|---|---|---
ARCH1 =Archeon Contemporary Size 1 BAA-ARCH1 =Archeon Contemporary
Buy American Act Compliant²
TAA-ARCH1 =Archeon Contemporary Trade Agreements Act Compliant²
| 20 =20W (nominal) 30 =30W (nominal) 40 =40W (nominal) 50 =50W (nominal) 60 =60W (nominal)| 722 =70CRI, 2200K
727 =70CRI, 2700K
730 =70CRI, 3000K
740 =70CRI, 4000K
750 =70CRI, 5000K
AMB =Amber (check with factory quotes team for availability)
| U =Universal (120-277V)
1 =120V
2 =208V
3 =240V
4 =277V
8 =480V
9 =347V
H =High Voltage Driver (347-480V)
| T2R =Type II Roadway T2U =Type II Urban T3 =Type III T4W =Type IV Wide
5WQ =Type V Square Wide
| [Blank] =None
A15 =15″ Straight Mast Arm
ASJS00 =Adjustable Slipfitter (Factory set at 0°)
ASJS15 =Adjustable Slipfitter (Factory set at 15°)
ASJS25 =Adjustable Slipfitter (Factory set at 25°)
ASJS45 =Adjustable Slipfitter (Factory set at 45°)
| AP =Grey BZ =Bronze BK =Black DP =Dark Platinum
GM =Graphite Metallic
WH =White
Options (Add as Suffix)| | Controls| | Accessories (Order
Separately)
F =Single Pole Fusing, specify voltage (120V, 277V, 347V) FF =Double
Pole Fusing, specify voltage (208V, 240V, 480V) 10MSP =Parallel 10kV MOV
Surge Protection Device 10K =Series 10kV UL 1449 Surge Protection Device
20MSP =Parallel 20kV MOV Surge Protection Device 20K =Series 20kV UL
1449 Surge Protection Device 20KI =Series 20kV UL 1449 Surge Protection
Device with light indicator
HSS =Factory Installed House Side Shield3 HA =50°C High Ambient Temperature4 K =Level Indicator
CC =Coastal Construction5
XTB =No Terminal block
Dxxxxx =DOT Configuration – Contact Quotes Team
Uxxxxx =Utility Configuration – Contact Quotes Team
| PSC =Photocontrol Shorting Cap6 NPC =NEMA Photocontrol – Multi-Tap6 LLPC =Longlife Photocontrol Included6
PR =NEMA 3-PIN Twistlock Photocontrol Receptacle6
XPR =No Photocontrol Receptacle
FADC =Field Adjustable Dimming Controller7
DALI =DALI Driver(s) – check with factory quotes team for availability D4 =D4i driver(s) – check with factory quotes team for availability Z4 =4-pin DALI receptacle Zhaga Book 188, 9, 11
ZD =4-pin DALI receptacle Zhaga Book 18 for Wavelinx Wireless Sensor8, 10, 11 SWPD4XX =WaveLinx Wireless Sensor, 7′-15′ mounting height11, 1² SWPD5XX =WaveLinx Wireless Sensor, 15′-40” mounting height11, 1² WOBXX =WaveLinx Wireless Sensor with Bluetooth, 7′-15′ mounting height11, 1² WOFXX =WaveLinx Wireless Sensor with Bluetooth, 15′-40′ mounting height11, 1² ZSC =Zhaga Book 18 shorting cap13
| OA / RA1013 =Photocontrol Shorting Cap OA1223 =10kV Surge Module Replacement OA/RA1014 =NEMA Photocontrol – 120V OA/RA1016 =NEMA Photocontrol – Multi-Tap
A15-xx =15″ Straight Mast Arm (replace xx with finish color designator)
ASJS00-xx =Adjustable slipfitter, Factory set at 10º (replace xx with finish color designator)
ASJS15-xx =Adjustable slipfitter, Factory set at 15º (replace xx with finish color designator)
ASJS25-xx =Adjustable slipfitter, Factory set at 25º (replace xx with finish color designator)
ASJS45-xx =Adjustable slipfitter, Factory set at 45º (replace xx with finish color designator)
PBHSS =House Side Shield (Single)3
PBPFS =Perimeter Fence Shield Kit (4 Pieces)
NOTES:
- Customer is responsible for engineering analysis to confirm pole and fixture compatiblity for all applications. Refer to our white paper WP513001EN for additional support information.”
- Only product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements.”
- Not available/compatible with 5WQ optic
- Not available in 50W or 60W configurations
- Coastal construction finish salt spray tested to over 5,000-hours per ASTM B117, with a scribe rating of 9 per ASTM D1654.”
- Not available with XPR option
- Must specify PR or XPR
- Must specify XPR (no NEMA receptacle)
- For use only with other manufacturers’ Zhaga Book 18 sensors; not available when Wavelinx Wireless Sensors (SWPD, WOB) are also selected
- Select this option only when Wavelinx Wireless Sensors (SWPD, WOB) are also selected
- Must select DALI or D4 driver option
- Must select ZD receptacle option
- Must select Z4 or ZD receptacle option
House Side Shield Details
Perimeter Shield Details
Mounting Details
Installation Overview
Quick Instruction Steps:
- Open Door Latch
- Loosen Bolts for Mast Arm Clamp (Inside Housing)
- Insert Mast Arm Into Fixture Through Mast Receptacle
- Wire Appropriately
- Tighten Bolts on Mast Arm Clamp
- Close fixture Door and Secure Door Latch
Energy and Performance Data
Nominal Power (Watts)| 20| 30| 40| 50|
60
---|---|---|---|---|---
Actual Power (Watts)| 23.5| 33| 43| 53| 60
Wattage Label| 20| 30| 40| 50| 60
Input Current @ 120V (A)| 0.20| 0.28| 0.36| 0.44| 0.50
Input Current @ 277V (A)| 0.08| 0.12| 0.16| 0.19| 0.22
Input Current @ 347V (A)| 0.07| 0.10| 0.12| 0.15| 0.17
Input Current @ 480V (A)| 0.05| 0.07| 0.09| 0.11| 0.13
Supplemental Lumen Tables
Archeon Contemporary – ARCH1 IES Files
70 CRI, 3000K
T2R| Lumens| 3,471| 4,564| 5,637| 6,559| 7,110
Lumens per Watt| 148| 138| 131| 124| 118
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B2 U0 G2| B2 U0 G2
T2U| Lumens| 3,441| 4,524| 5,588| 6,502| 7,048
Lumens per Watt| 146| 137| 130| 123| 117
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B2 U0 G2| B2 U0 G2
T3| Lumens| 3,418| 4,495| 5,551| 6,459| 7,001
Lumens per Watt| 145| 136| 129| 122| 117
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G2
** T4W| Lumens| 3,312| 4,355| 5,379| 6,258| 6,783
Lumens per Watt| 141| 132| 125| 118| 113
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G2
5WQ| Lumens| 3,465| 4,556| 5,628| 6,548| 7,097
Lumens per Watt| 147| 138| 131| 124| 118
BUG Rating| B2 U0 G1| B3 U0 G1| B3 U0 G1| B3 U0 G1| B3 U0 G1
70 CRI, 4000K**
T2R| Lumens| 3,644| 4,792| 5,919| 6,887| 7,465
Lumens per Watt| 155| 145| 138| 130| 124
BUG Rating| B1 U0 G1| B1 U0 G1| B2 U0 G1| B2 U0 G2| B2 U0 G2
T2U| Lumens| 3,613| 4,751| 5,868| 6,827| 7,400
Lumens per Watt| 154| 144| 136| 129| 123
BUG Rating| B1 U0 G1| B1 U0 G1| B2 U0 G2| B2 U0 G2| B2 U0 G2
T3| Lumens| 3,589| 4,719| 5,829| 6,782| 7,351
Lumens per Watt| 153| 143| 136| 128| 123
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G2
T4W| Lumens| 3,477| 4,572| 5,648| 6,571| 7,122
Lumens per Watt| 148| 139| 131| 124| 119
BUG Rating| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G1| B1 U0 G2
5WQ| Lumens| 3,638| 4,784| 5,909| 6,875| 7,452
Lumens per Watt| 155| 145| 137| 130| 124
BUG Rating| B2 U0 G1| B3 U0 G1| B3 U0 G1| B3 U0 G1| B3 U0 G1
Lumen Maintenance
Ambient Temperature| 25,000
**hours***
| 50,000
**hours***
| 60,000
**hours***
| 100,000
**hours***
| **L70***
---|---|---|---|---|---
25°C| 98.1%| 96.3%| 95.6%| 92.8%| >102,000
40°C| 98.0%| 96.1%| 95.3%| 92.3%| >102,000
50°C| 97.8%| 95.6%| 94.8%| 91.4%| >102,000
Note: * Calculations provided in accordance with IES TM-21-11 using the configuration resulting in highest LED temperature. Previous versions of IES TM-21 where theoretical calculations were used are no longer recommended as a proxy of lumen depreciation.
LED Color Multipliers
| CCT
---|---
2200| 2700| 3000| 4000| 5000
CRI| | Lumen Multiplier*|
70| 0.83| 0.92| 0.95| 1.00| 1.00
80| —| 0.85| —| —| —
Note: * Estimates, refer to IES files for accuracy.
Lumen Multiplier
Ambient Temperature | Lumen Multiplier |
---|---|
0°C | 1.02 |
10°C | 1.01 |
25°C | 1.00 |
40°C | 0.99 |
50°C | 0.97 |
FADC Settings
FADC Position | Percent of Typical Lumen Output |
---|---|
1 | 25% |
2 | 48% |
3 | 56% |
4 | 65% |
5 | 75% |
6 | 80% |
7 | 85% |
8 | 90% |
9 | 95% |
10 | 100% |
Note: +/-5% typical value
Note: +/-5% typical value
Optical Distributions
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2024 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>