wilfa AC1W-7000 Connected Air Conditioner Instruction Manual

June 1, 2024
Wilfa

wilfa-LOGO

wilfa AC1W-7000 Connected Air Conditioner

wilfa-AC1W-7000-Connected-Air-Conditioner-PRODUCT

Product Specifications

  • Product Name: CHILL 12 CONNECTED AIR CONDITION AC2B-12000C
  • Refrigerant: R290 (environmentally friendly with no damaging influence on the ozone layer)
  • Features: Wifi connectivity, Remote control, Timer setting, Drainage system, Control panel with display

Product Usage Instructions

Important Safety Instructions

It is crucial to read all safety instructions before using the air conditioner to prevent any potential hazards. The unit uses a flammable refrigerant and precautions should be taken to ensure safe operation.

Operational Precautions

Follow these operational precautions to reduce the risk of fire, electric shock, or injury:

  • Only certified personnel should work on or break into the refrigerant circuit.
  • Servicing and maintenance should be performed as recommended by the manufacturer.
  • Do not replace or extend the exhaust hose to maintain efficiency and prevent unit shutdown.

Product Overview

  • The air conditioner features a control panel, adjustable louver air outlet, air inlet with air filter, drainage hole, remote control, and other accessories for efficient cooling.

Installation

  • Choose Your Location: Select a suitable location for the air conditioner installation.
  • Attach the Exhaust Hose: Vent the air conditioner outside using the provided exhaust hose to release waste heat and moisture. Do not replace or extend the hose to maintain unit efficiency.

Control Panel and Display

  • The control panel allows you to adjust settings such as temperature, fan speed, and mode. The display provides real-time information on the unit’s operation.

Remote Control

  • Use the remote control to conveniently operate the air conditioner from a distance. Ensure proper battery installation and point it towards the unit for effective control.

Settings

  • Adjust various settings on the air conditioner, including fan speed, cooling mode, and timer settings for personalized comfort.

Troubleshooting

  • Refer to the troubleshooting section in the user manual for guidance on resolving common issues with the air conditioner.

FAQ (Frequently Asked Questions)

Q: Can I use this air conditioner without venting it outside?

A: No, it is essential to vent the air conditioner outside to release waste heat and moisture for efficient operation.

Q: How often should I clean the air filter?

A: It is recommended to clean the air filter every 2-4 weeks to maintain optimal performance.

IMPORTANT SAFETY INSTRUCTIONS

  • Read this instruction manual thoroughly before use and save it for future reference. It is also available on our website; wilfa.com.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
  • This product is intended for indoor, non-industrial, non-commercial; household use only.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • The unit is designed only for use with R- 290(propane) gas as the designated refrigerant.
  • The refrigerant loop is sealed. Only a qualified technician should attempt to service!
  • Do not discharge the refrigerant into the atmosphere.
  • R-290 (propane) is flammable and heavier than air. It accumulates first in low areas but can be circulated by fans.
  • If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
  • The propane gas used in the unit has no odor.
  • The lack of smell does not indicate a lack of escaped gas.
  • If a leak is detected, immediately evacuate all persons from the room, ventilate the room, and contact the local fire department to advise them that a propane leak has occurred.
  • Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
  • No open flames, cigarettes, or other possible sources of ignition should be used inside or in the vicinity of the units.
  • Parts are designed for propane and non-incentive and non-sparking. Parts shall only be replaced with identical repair parts.
  • FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
  • The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP), and is available worldwide.
  • Because of its efficient energy properties, R290 is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant’s high flammability.

SYMBOLS FROM THE UNIT AND USER MANUAL

  • Warning This unit uses a flammable refrigerant.
    • If refrigerant leaks and comes in contact with a fire or heating part, it will create harmful gas and there is a risk of fire.
  • Read the USER MANUAL carefully before operation.
  • Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
  • Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

OPERATIONAL PRECAUTIONS

  • WARNING- to reduce the risk of fire, electric shock, or injury to persons or property:
  • Always operate the unit from a power source of equal voltage, frequency, and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture, or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged, or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed under national wiring regulations.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuous operating sources (for example: open flames, an operating gas appliance, or an operating electric heater).
  • The appliance shall be stored to prevent mechanical damage from occurring.
  • Do not pierce or burn, even after use.
  • Be aware that refrigerants may not contain an odor.
  • Pipework shall be protected from physical damage and shall not be installed in an unventilated space if that space is smaller than 8m².
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • WARNING Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely under an industry-recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

PRODUCT OVERVIEW

  1. Control panel
  2. Air outlet with adjustable louver
  3. Handle
  4. Air inlet with air filter
  5. Wheel
  6. Drainage hole
  7. Air exhaust
  8. Front panel

Accessories:

  1. Exhaust hose
  2. Hose connector
  3. Window kit adapter
  4. Remote control
  5. Window bracket
  6. Drainage hose

Note: The appearance is only for reference. Please see the real product for detailed information.

INSTALLATION

CHOOSE YOUR LOCATION

  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start-up.
  • Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
  • Do not operate close to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
  • Never install the unit where it could be subject to:
  • Heat sources such as radiators, heat registers, stoves, or other products that produce heat.
  • Direct sunlight
  • Mechanical vibration or shock
  • Excessive dust
  • Lack of ventilation, such as a cabinet or bookcase
  • Uneven surface

WARNING!

  • Install the unit in rooms that exceed 10 m².
  • Do not install the unit in a place where inflammable gas may leak.

ATTACH THE EXHAUST HOSE

  • The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture.
  • Do not replace or extend the exhaust hose which will result in decreased efficiency or, even worse shut down the unit due to low back pressure.
  1. Step 1: Connect the hose connector to one end of the exhaust hose.
  2. Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
  3. Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.
  4. Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place and secure the window kit with duct tape if required.
    • It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
  5. Step 5: Attach the hose connector to the exhaust air outlet of the unit.
  6. Step 6: Adjust the length of the flexible exhaust hose, to make sure the distance between the unit and the window will be more than 70cm and, height from the exhaust hose to the floor will be more than 90cm. And avoid bends in the hose. Then place AC near an electrical outlet.
  7. Step 7: Adjust the louver at the air outlet, and then switch on the unit.

CONTROL PANEL AND DISPLAY

wilfa-AC1W-7000-Connected-Air-Conditioner-FIG-12

1 SWING Adjust the air flow direction vertically.
2 MODE Mode button Press to switch the operation mode between fan, cooling,

and dehumidifier.
3| UP| Increasing the desired temperature (16°C – 32°C) or timer setting.
4| POWER| Press to switch the machine on or off.
5| DOWN| Decreasing the desired temperature or timer setting.
6| SPEED| Press to switch the fan speed between high, medium, and low.
7| TIMER| Sets a time for the unit to automatically start or stop.
8| SLEEP| Press to enter sleep mode. Can only be entered in cooling mode.
9| INDICATORS| LED indicators for fan speed and WIFI.
10| LED Display| This LED Displays the Room Temperature or Time Setting.
11| MODE Indicator| This displays the Mode Setting between the fan, cooling, and dehumidifier.

REMOTE CONTROL

wilfa-AC1W-7000-Connected-Air-Conditioner-FIG-13

SETTINGS START-UP AND SHUTDOWN

  • Press POWER to turn the unit on.
  • Press the MODE button to select the desired operation mode.
  • Press POWER again to turn off the power.

OPERATION MODE

  • The unit has four operation modes: Cool, dry, fan, and sleep.

COOLING YOUR ROOM

  • Select the cool mode to lower the temperature in your room.
  • Press the MODE button repeatedly until the COOL indicator lights up.
  • Press the Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between 16°C and 32°C.
  • Press the SPEED button repeatedly until the desired fan speed indicator lights up.
  • To control the direction of the airflow horizontally, please adjust the inner louver by hand.
  • Note: The air conditioner stops if the room temperature is lower than the selected temperature.

VENTILATING YOUR ROOM

  • Press the MODE button repeatedly until the FAN indicator lights up.
  • In ventilation mode, the room air is circulated, but not cooled.
  • Press the SPEED button repeatedly to select the fan speed as desired.

DRYING YOUR ROOM

  • Press the MODE button on the control panel or remote control, and the dry indicator lights up. The fan speed is unable to be selected. The user should connect the hose to the drain outlet at the bottom of the unit.
  • Note: In this mode, the fan speed switches over to low speed and cannot be selected.

SLEEP MODE

  • The sleep button can only be set in cooling mode.
  • The machine enters sleep mode, all lights are dimmed at the same time, and the buzzer is disabled in sleep mode:
  • 1 hour after sleep mode is turned ON, the set temperature will automatically increase by 1°C, and after another hour, the set temperature will automatically increase by 1°C.

AUTOMATIC DEFROST

  • At low room temperatures, frost may build up at the evaporator during operation. The unit will automatically start defrosting and the POWER LED will blink.

The de-frost control sequence is as follows:

  • A. When the unit operates in the cooling and drying operation, and the ambient temperature sensor senses the evaporator coil temperature is below -1°C after the compressor stops operating for 10 minutes or the coil temperature up to 7°C, the unit restarts to cool operating mode.
  • B. When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40°C and the differential temperature between coil temperature and room temperature is below 19°C after the compressor operation for 20 minutes, the unit starts defrosting for 5 minutes and the power indicator blinking.

TIMER SETTING (1HOUR-24HOURS)

The timer has two ways of operation:wilfa-AC1W-7000-Connected-Air-
Conditioner-FIG-14

OVERLOAD PROTECTION

In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.

DRAINAGE MANUAL DRAINAGE

  1. When the machine stops after the water is full, please unplug the power plug.
    • Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.
  2. Place the water container below the side water outlet behind the body.
  3. Unplug the water plug, the water will automatically flow into the water container.

Notes:

  1. Keep the water plug properly.
  2. During drainage, the body can be tilted slightly backward.
  3. If the water container cannot hold all the water before the water container is full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
  4. When the water is discharged, stuff the water plug.
  • Notes: Restart the machine after the water plug and drainage cover are installed, otherwise condensate water of the machine will flow to the floor or the carpet.

SELF- EVAPORATING SYSTEM

  • The self-evaporating system uses the collected water to cool the condenser coils for better, more efficient performance.
  • There is no need to empty the drainage tank in cooling mode, except in high humidity conditions.
  • In drying mode, the drainage tank needs to be emptied. The condensed water evaporates at the condenser and disappears through the exhaust hose.
  • For continuous operation or unattended operation in drying mode, please connect the attached drain hose to the unit. Condensed water can automatically run into a bucket or drain.
  • Switch off the unit before operating.
  • Remove the plug of the water outlet opening and keep it in the safe area.
  • Securely and properly connect the drain hose. Make sure it is not kinked and clear of obstruction.
  • Place the outlet of the hose over a drain or bucket and ensure that water can freely flow out of the unit.
  • Do not submerge the end of the hose into the water; otherwise, it can cause an “Air Lock” in the hose.

TO AVOID WATER SPILLAGE

  • As the negative pressure of the condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
  • Straighten the hose to avoid trapping water in the hose.

DISASSEMBLY AND CLEANING

CLEANING THE AIR FILTER (EVERY TWO WEEKS)

  • Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
  • The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.
  1. Press the POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to vacuum dust from the filter.
  4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.

TROUBLESHOOTING

Problem Possible reasons Solutions
The unit is not operating Check the power connection securely.
Check if the water level indicator lights up.Check the room temperature.

Insert the power cord securely into the wall outlet.

Empty the drain pan by removing the rubber plug.

The range of operating temperature is 5-35°C.

The unit works with reduced capacity.| Check the air filter for dust.

Check if the air duct is blocked.

Check if the door or window is open.

Check if the desired operating mode is selected and the temperature is properly set.

The exhaust hose is detached.

| Clean the air filter as necessary.

Clear the obstacle.

Keep the door and windows closed.

Set the mode and temperature at the desired point according to the manual.

Make sure the exhaust hose is securely attached.

Water Leakage| Overflow while moving the unit.

Check if the drain hose is kinked or bends.

| Empty the water tank before transport.

Straighten the hose to avoid trapping water.

Excessive Noise| Check if the unit is securely positioned.

Check if any loose, vibrating parts.

The noise sounds like water flowing.

| Place the unit on a horizontal and firm floor.

Secure and tighten the parts.

Noise comes from flowing

refrigerant. This is normal.

STORAGE

Long-Term Storage – If you will not be using the unit for an extended time (more than a few weeks) it is best to clean the unit and dry it out completely.

Please store the unit per the following steps:

  1. unplug the unit and remove the exhaust hose and window kit stored with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Re-install the filter at its position.
  5. The unit must be kept in an upright position when in storage.
  6. Preserve the machine in ventilating, dry, non-corrosive gas and safe place indoors.

WIFI DESCRIPTION

INFORMATION ON THE APP “WILDLIFE”

  • The “WiLife” app is available for Android and iOS. Scan the corresponding QR code to get directly to the download.

INFORMATION ON HOW TO USE THE APP

  • This appliance allows you to operate the appliance via your home network. A prerequisite is a permanent Wi-Fi connection to your router and the free app “WiLife”.
  • We recommend disconnecting the appliance from the power supply when you are away from home to prevent unintentional switching on while you are on the road.

SYSTEM REQUIREMENT FOR USE OF THE APP

  • iOs 11.0 or higher
  • Android 5.0 or higher
  • Bluetooth 4.2

COMMISSIONING VIA THE APP FOR WIFI

  1. Install the “WiLife” app. Create a user account.
  2. Activate the Wi-Fi function in the settings of your appliance.
  3. Place the appliance at a distance of about 5 meters from your router.
  4. Press and hold the Timer button for about 3 seconds. The Wi-Fi lamp will flash rapidly.
  5. Launch the app and select ”+”.
  6. Select the “Air Conditioner” menu and follow the instructions on the display.
  7. Once the appliance has been successfully connected, the Wi-Fi lamp lights up. Now you can operate the appliance using the app.
  8. Press and hold the Timer button for about 3 seconds, the appliance disconnects, and the Wi-Fi lamp lights off.

COMMISSIONING VIA THE APP FOR BLUETOOTH

  1. Install the “WiLife” app. Create a user account.
  2. Turn on the Bluetooth on your smartphone.
  3. Turn on the device.
  4. Within 10 meters of the device, open the app, and the device should appear automatically on the bottom of your screen
  5. Follow further instructions on the app

TROUBLESHOOTING CONNECTION

Problem Solutions
The device does not show up in the app when you try to connect with wi-fi

Make sure your Bluetooth is turned on on your smartphone. Turn your internet off for 3 minutes. Keep your phone within 10 meters of the unit and try to connect again using bluetooth.
The device does not show up in the app when you try to connect with Bluetooth| Press the + in the upright corner and press “large home appliances”, then add air conditioner. Press and hold the timer button for 3 seconds until the wi-fi lamp flashes rapidly. Then follow the instructions on the app
The app is not working to control the device| Make sure you are connected to the wi-fi. If the wi-fi is down, make sure you are connected to Bluetooth

Turn the device off for 5 seconds and turn it back on.

Restart the application.

GUARANTEE

  • Wilfa issues a 5-year guarantee on this product from the day of purchase. The guarantee covers production failure or defects that arise during the guarantee period.
  • Your purchase receipt works as proof towards the retailer if claiming your guarantee.
  • The guarantee is valid only for products that are bought and used in private households. The guarantee is not valid if the product is used commercially.
  • The guarantee is not valid if the product is misused, used by negligence, if not following instructions given by Wilfa, if modified or if unauthorized reparation is done.
  • The guarantee is also not valid for normal wear of the product, misuse, lack of maintenance, use of wrong electrical voltage, or:
  • Overloading of product
  • Parts which are normally worn down
  • Parts you can expect to be replaced regularly (e.g. filter, battery, etc.)
  • Instructions manual is also available at our website wilfa.com

PRODUCT SPECIFICATIONS

  • 220-240V~50Hz 1300W
  • Gas R290: 195g

SUPPORT AND SPARE PARTS

  • For support please visit us at wilfa.com, and see our customer service/support page.
  • Here you will find frequently asked questions, spare parts, tips and tricks, and all our contact information.

RECYCLABILITY

  • This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling free of charge.
  • Releasing refrigerant into the atmosphere is strictly forbidden!

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals