WILO PB-400EA High Pressure Pump Instruction Manual

June 3, 2024
wilo

High Pressure Pump
Instruction Manual

WILO PB-400EA High Pressure Pump -

PB-400EA High Pressure Pump

WILO PB-400EA High Pressure Pump - Featured Image| WILO PB-
400EA High Pressure Pump - Fig1
---|---

About this document
The language of the original operating instructions in English. All other languages of these instructions are translations of the original operating instructions. These installation and operating instructions are an integral part of the product. They must be kept readily available at the place where the product is installed. Strict adherence to these instructions is a precondition for the proper use and correct operation of the product. This installation and operating instructions correspond to the relevant version of the product and the underlying safety standards valid at the time of going to print. EC declaration of conformity: A copy of the EC declaration of conformity is a component of these operating instructions. If a technical modification is made on the designs named there without our agreement, this declaration loses its validity.

Safety
These operating instructions contain basic information which must be adhered to during installation, operation, and maintenance. For this reason, these operating instructions must, without fail, be read by the service technician and the responsible specialist/ operator before installation and commissioning. It is not only the general safety instructions listed under the main point “safety” that must be adhered to but also the special safety instructions with danger symbols included under the following main points.
General danger symbol
Danger due to electrical voltage Note

2.1 Personnel qualifications
The installation, operating, and maintenance personnel must have the appropriate qualifications for this work. Area of responsibility, terms of reference and monitoring of the personnel are to be ensured by the operator. If the personnel are not in possession of the necessary knowledge, they are to be trained and instructed. This can be accomplished if necessary by the manufacturer of the product at the request of the operator.

2.2 Danger in the event of non-observance of the safety instructions
Non-observance of the safety instructions can result in risk of injury to persons and damage to the environment and the product/unit. Non-observance of the safety instructions results in the loss of any claims to damages. In detail, non-observance can, for example, result in the following risks:

  • Danger to persons from electrical, mechanical and bacteriological influences,
  • Damage to the environment due to leakage of hazardous materials
  • Property damage
  • Failure of important product/unit functions
  • Failure of required maintenance and repair procedures

2.3 Safety consciousness on the job
The safety instructions included in this installation and operating instructions, the existing national regulations for accident prevention together with any internal working, operating, and safety regulations of the operator are to be complied with.

2.4 Safety instructions for the operator
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  •  If hot or cold components on the product/the unit lead to hazards, local measures must be taken to guard them against touching.
  • Guards protecting against touching moving components (such as the coupling) must not be removed whilst the product is in operation.
  • Leakages (e.g. from the shaft seals) of hazardous fluids (which are explosive, toxic or hot) must be led away so that no danger to persons or to the environment arises. National statutory provisions are to be complied with.
  • Highly flammable materials are always to be kept at a safe distance from the product.
  •  Danger from electrical current must be eliminated. Local directives or general directives [e.g. IEC, VDE, etc.] and local power supply companies must be adhered to.

2.5 Safety instructions for installation and maintenance work
The operator must ensure that all installation and maintenance work is carried out by authorized and qualified personnel, who are sufficiently informed from their own detailed study of the operating instructions. Work on the product/unit must only be carried out when at a standstill. It is mandatory that the procedure described in the installation and operating instructions for shutting down the product/unit be complied with. Immediately on conclusion of the work, all safety and protective devices must be put back in position.and/or recommissioned.
2.6 Unauthorised modification and manufacture of spare parts
Unauthorized modification and manufacture of spare parts will impair the safety of the product/ personnel and will make void the manufacturer’s declarations regarding safety. Modifications to the product are only permissible after consultation with the manufacturer. Original spare parts and accessories authorized by the manufacturer ensure safety. The use of other parts will absolve us of liability for consequential events.
2.7 Improper use
The operating safety of the supplied product is only guaranteed for conventional use in accordance with Section 4 of the operating instructions. The limit values must on no account fall under or exceed those specified in the catalog/datasheet.
General
See the start of the document.
Safety
See the start of the document.
Transport and interim storage
When you receive the equipment, check that it has not been damaged during transport. If you notice a fault, take all necessary action with the carrier within the time allowed. CAUTION! Storage environment may cause damage. If the equipment is to be installed at a later date, store it in a dry place and protect it from impacts and any external stresses (humidity, frost etc.). Temperature range for transport and storage: -30°C to +60°C Handle the pump with care so as not to damage the product before installation.

Application

These devices are domestic pressure-boosting systems designed for pressurizing clean water. The downward type is designed for boosting water from roof-top water tank to the lower floors using water and the upward type is designed for boosting water from the tank on the ground to upper floors.
DANGER! Risk of explosion!
Do not use this pump to convey flammable or explosive liquids.

Technical data

5.1 Data table Upward type (60 Hz)

Hydraulic data PB-410SMA PB-601SMA
Maximum operating pressure 3.8 bar (3.8 x 105 Pa) Ł.2 bar (Ł.2 x 105 Pa)
Maximum suction pressure 1.3 bar (1.3 x 105 Pa) 1.Ł bar (1.Ł x 105 Pa)
Maximum altitude 1000 m
Suction head Max. 3 m (available with a foot valve at the end of the suction

pipe only)
DN of the suction connection| 1″| 1 1/Ł”
DN of pressure connection
Temperature range
Fluid temperature range| +5°C to +60°C
Ambient temperature| max. +Ł0°C
Electrical data
Motor protection rating| IPXŁ
Insulation class| F_155
Frequency| 60 Hz 220 V
Voltage
Other
Max. sound level| 62 dB(A)

Upward type (50 Hz)

Hydraulic data PB-250SEA PB-401SEA
Maximum operating pressure 2.7 bar (2.7 x 105 Pa) 3.1 bar (3.1 x 105 Pa)
Maximum suction pressure 0.9 bar (0.9 x 105 Pa) 1 bar (1 x 105 Pa)
Maximum altitude 1000 m
Suction head Max. 3 m (available with a foot valve at the end of the suction

pipe only)
DN of suction connection| 1″| 1 1/Ł”
DN of pressure connection
Temperature range
Fluid temperature range| +5°C to +60°C
Ambient temperature| max. +Ł0°C
Electrical data
Motor protection rating| IPXŁ
Insulation class| F_155
Frequency| 50 Hz 220 V – 230 V
Voltage
Other
Max. sound level| 62 dB(A)

Downward type (60 Hz)

Hydraulic data| PB-138MA| PB-S250MA| PB-350/351MA| PB- 600MA
---|---|---|---|---
Maximum operating pressure| 1.8 bar (1.8 x 105 Pa)| 2.3 bar (2.3 x 105 Pa)| 3.2 bar (3.2 x 105 Pa)| Ł.2 bar (Ł.2 x 105 Pa)
Maximum suction pressure| 0.6 bar (0.6 x 105 Pa)| 0.8 bar (0.8 x 105 Pa)| 1.1 bar (1.1 x 105 Pa)| 1.Ł bar (1.Ł x 105 Pa)
Maximum altitude| 1000 m
Suction head| –
DN of the suction connection| 3/Ł”| 1 1/Ł“
DN of pressure connection
Temperature range
Fluid temperature range| +5°C to +80°C
Ambient temperature| max. +Ł0°C
Electrical data
Motor protection rating| IPXŁ
Insulation class| F_155
Frequency| 50 Hz 220 V – 230 V
Voltage
Other
Max. sound level| 62 dB(A)

Downward type (50 Hz)

Hydraulic data| PB-088EA| PB-S125EA| PB-201EA| PB- 400EA
---|---|---|---|---
Maximum operating pressure| 1.2 bar (1.2 x 105 Pa)| 1.6 bar (1.6 x 105 Pa)| 2.2 bar (2.2 x 105 Pa)| 3 bar (3 x 105 Pa)
Maximum suction pressure| 0.Ł bar (0.Ł x 105 Pa)| 0.5 bar (0.5 x 105 Pa)| 0.7 bar (0.7 x 105 Pa)| 1 bar (1 x 105 Pa)
Maximum altitude| 1000 m
Suction head| –
DN of the suction connection| 3/Ł”| 1 1/Ł“
DN of pressure connection
Temperature range
Fluid temperature range| +5°C to +80°C
Ambient temperature| max. +Ł0°C
Electrical data
Motor protection rating| IPXŁ
Insulation class| F_155
Frequency| 50 Hz 220 V – 230 V
Voltage
Other
Max. sound level| 62 dB(A)

5.2 Scope of delivery

  • Single-stage horizontal automatic pump
  • Installation and operating instructions
  • Assembly package (2 sets of unions, nipples, and gaskets for piping, for PB-088EA, PB-138MA, and PB-350MA only)
  • Assembly package (2 sets of flanges, and gaskets, for upward type only)

Products and functions

6.1 Product description (see Figures)
Pressure boosting systems for domestic applications require higher water pressure from a roof-top water tank (downward type) or a water tank on the ground (upward type).
6.2 Product function
Operating options as “Auto”, “Manual”, and “Off” for downward type only. Automatic operation with flow switch. Automatic operation with flow switch and pressure switch in case of upward type.
6.3 The pump
Single-stage horizontal centrifugal, non-self-priming pump. Shaft sealing with mechanical seal. 6.4 The motor Single-phase, 2-pole, 50 Hz and 60 Hz motor, the capacitor in the terminal box, and thermal protector for motor protection.

  • Protection class: IPX4
  • Insulation class: F_155
Frequency 50 Hz 60 Hz
Speed in RPM ~ 2900 ~ 3500
Voltage 1 ~ 230V (±10%)

Installation and connections

All installation and electrical connection work must be carried out solely by authorized and qualified personnel, in accordance with applicable regulations.
WARNING! Physical injuries!
The applicable regulations for the prevention of accidents must be complied with.
7.1 Upon receipt of the product
Unpack the pump and recycle or dispose of the packaging in an environmentally responsible manner.
7.2 Hydraulic connections General connection instructions

  • Use flexible, braid-reinforced hose piping or rigid piping.
  • The pump must not bear the weight of the pipes.
  • Seal the piping well using appropriate products.

Suction connections

  • The diameter of the suction pipe must never be less than the port on the product. Handling and installation
  • See Fig. 1 to 4 for the upward type.
  • See Fig. 5 to 11 for the downward type. (Fig. 8 installation is available only for PB-200EA and PB-350MA)
  • Suction mode installation of upward type (Fig. 2). Fig. 2, item 1: Foot valve (not in the scope of delivery)

7.3 Electrical connection
WARNING! Risk of electric shock! Danger from electrical current must be eliminated.

  • Have all electrical work carried out by a qualified electrician only!

  • Before any electrical connection is made, the pump must be de-energized (switched off) and protected against unauthorized restarting.

  • To ensure safe installation and operation, the unit must be earthed correctly with the earth terminals of the power supply.
    CAUTION! An error in the electrical connection will damage the motor. The power cable must never touch the piping or the pump and must be kept away from any moisture.

  • See the pump cladding for its electrical characteristics (frequency, voltage, current).

  • The single-phase motor of this pump has a built-in thermal protector.

  • See the wiring diagram marked on the inside of the terminal cover, fasten the cable with the cable gland and cable anchorage located in a terminal box securely when the cable connector is.

  • The cross-section of the supply cord for this pump shall be at least 3  x  0,75  mm² and the properties of the supply cord shall be at lease ordinary polychloroprene sheathed cords (60245 IEC 57).

  • A damaged cable or connector must be replaced by the corresponding part available from the manufacturer or the manufacturer’s customer service.

Commissioning
Check that there are no leaks at the connections to the sanitary devices connected to the lifting unit.

  • Switch the power supply to the unit.
  • Check that the current consumed is less than or equal to the rated current.

Maintenance

All maintenance work must be carried out by authorized and qualified personnel!
WARNING! Risk of electric shock! Danger from electrical current must be eliminated.
Before carrying out any electrical work, the pump must be de-energized (switched off) and protected against unauthorized restarting. It is recommended to disconnect the plug.

  • No special maintenance work is required during operation.
  • Keep the pump clean.
  • If the pump is deactivated for a long period and there is no risk of freezing, it is best not to drain the pump. In the event of prolonged absence, be sure to cut off the mains’ water supply and protect the installation from freezing.

Faults, causes and remedies

Faults Causes Remedies
The motor does not start Thermal protector If the motor is overheated, it

will not operate. Then,  ait until the motor is cold. (20 – 30 minutes)
Faulty cable connection| Insert the power plug securely
The cable is disconnected or damaged.| Replace the cable
Trouble in the motor| Repair or replace the motor
The power supply voltage is too low.| Check the voltage of the power supply and consult with the local power supplier
Water is not pumped out even though the motor is running| The water level of the well is lower than the standard level| Check the water level of well
Fault in foot valve| Take off the check valve case and then clean the valve, valve seat and valve hole
Air is drawn into the suction hose| Check for leaks in the entire pipe and seal these if any are found
Air is drawn into the pump from the mechanical seal| Replace the mechanical seal
Thermal protector for motor works too often| The power supply voltage is either too low or too high| Check the voltage of the power supply and consult with the local power supplier
The impeller is in contact with another component| Repair the defects.
Short or open circuit of the capacitor| Repair or replace the capacitor.
Water does not come during the first few minutes after being switched on| Air is drawn into the suction pipe| Check for leaks in the entire pipe or replace the defective piping (to prevent air leaking)
The pump starts without water| Piping or pump are leaking water| Repair piping, pump parts and faucets, etc
Water leaks on mechanical seal| Replace the mechanical seal
Trouble in checking the valve| Take off the check valve case and then, clean the valve, valve seat and valve hole
Defacement or transformation of the impeller| Replace the impeller

If you cannot remedy the fault, please contact Wilo customer service.
Spare parts

All spare parts should be ordered directly from Wilo customer service.
To prevent errors, always quote the data on the pump’s rating plate when making an order. The spare parts catalog is available at: www.wilo.com.
Disposal
Your device contains valuable raw materials which can be recycled. Therefore, please take your device to your local collection point in your town or district. Subject to technical modifications!

EU/EC DECLARATION OF CONFORMITY
We, the manufacturer, declare under our sole responsibility that the pump types of the series
PB-.EA/PB-S.EA./PB-.SEA: The serial number is marked on the product site plate.
In their delivered state comply with the following relevant directives :
– Low voltage 2014/35/EU from April 20th, 2016
– Electromagnetic compatibility 2014/30/EU from April 20th, 2016
– Restriction of the use of certain hazardous substances 2011/65/EU
And with the relevant national legislation.
comply also with the following relevant harmonized European standards :
EN 60335-2-41/EN 61000-3-2:2014/ EN 61000-3-3:2013/EN 55014-1:2006+A1+A2:2011/EN 55014-2:2015.
Dortmund,

Digital
Holger Herchenhein
Datum: 2017.01.06
09:24:54 +01’00’
H. HERCHENHEIN
Senior Vice President – Group ITQ

WILO SE
Nortkirchenstraβe 100
44263 Dortmund – Germany
F_GQ_013-21

Wilo International Subsidiaries
WILO SE
Nortkirchenstraße 100
D-44263 Dortmund
T +49(0)231 4102-0
F +49(0)231 4102-7363
wilo@wilo.com
www.wilo.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals