Hunter 19929 Two Light Vanity Instruction Manual
- June 3, 2024
- Hunter
Table of Contents
19929 Two Light Vanity
Instruction Manual
19929 Two Light Vanity
For Models : 19928 19929, 19930 19931,19932 19933
Here are the tools you’ll need to complete your installation:
Ladder|
---|---
Screwdriver|
Pliers|
Wire Strippers|
2 Light Vanity
Fixture weight ±2 lbs: 3.67 lbs (1.66 kg)
Hardware Service Kit
Part # | Model | Finish |
---|---|---|
KE99701214 | 19928 | |
19931 | Brushed Nickel | |
KE99701834 | 19929 | |
19932 | Noble Bronze | |
KE99701L24 | 19930 | |
19933 | Palm Gold |
Glass
Part # | Model | Type |
---|---|---|
KE30101045 | 19928 |
19929
19930| Cased White Glass
KE30102046| 19931
19932
19933| Clear Seeded Glass
INSTALLATION INSTRUCTIONS
WARNING
- To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
- The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
- All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that
they are read carefully and completely before beginning the installation of
the lighting fixture.
PREPARING FOR INSTALLATION
Carefully remove all contents from the carton. Shut off the power at the
circuit breaker and completely remove the old fixture from the wall, including
the old mounting bracket. Remove the new mounting bracket assembly from the
bag. Pull the house wires through the center of the mounting plate (A). Secure
mounting plate (A) to the junction box by tightening the screws (B).
CONNECTING
THE WIRES
Have a helper support the fixture’s weight while completing the wiring.
Attach the fixture’s wires to the power supply wires from the junction box.
Connect black to black (live); white to white (neutral); grounding to
grounding (green or copper). Twist the ends of the wire pairs together. Then,
twist on a wire connector. Make sure all twists are in the same direction.
Loop the fixture’s ground wire around the grounding screw (C) and tighten. If
there is no ground wire (green or copper) from the junction box, contact a
qualified electrician.
FINISHING THE INSTALLATION
Place the fixture (E) over the mounting plate (A) making sure to align the holes of the fixture with the holes of the mounting plate. Secure the fixture with screws (D). Install the bulb according to the fixture specifications (not included). Do not exceed the recommended wattage. Lift the glass (F) and align the notches in the glass with the tabs in the lamp cup (E). Attach the glass by lifting and turning clockwise one-third of a full turn of the glass until it stops. Turn on the power and test the fixture. For a vertical installation make sure the mounting plate (A) has folded sides with drilled holes at the top and bottom of the junction box. Your installation is now complete.
CLEANING
TIPS Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray the cleaner directly onto the fixture.