Danfoss VLT FC 101 HVAC Basic Drive User Guide
- June 14, 2024
- Danfoss
Table of Contents
- Danfoss VLT FC 101 HVAC Basic Drive
- Makes your buildings perform
- Ideal for simple fans, pumps, and compressors
- VLT® HVAC Basic Drive
- Enclosure protection options
- Freedom to change settings prior to installation
- Technical data
- Electrical data – H and I enclosures
- Accessories
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Danfoss VLT FC 101 HVAC Basic Drive
Makes your buildings perform
Danfoss commitment
Danfoss’ longstanding experience in applying drives in HVAC systems has
enhanced our ability to design a HVAC Basic drive to the exact needs in simple
mass produced applications.
Save energy and CO2 emission
Energy savings through more than 1.5 million VLT® HVAC Drives installed
worldwide are estimated at 285 million MWhrs a year. This equals the annual
energy consumption of 60 million households and has an impact on the annual
CO₂ emissions – a reduction of 180 million tonnes!
A wealth of knowledge
The various applications incorporated within high performance buildings are
well understood by Danfoss and as global market leader we have built a wealth
of knowledge and developed products and technology to ensure we meet and shape
future trends in HVAC.
Danfoss experts with HVAC application knowledge support you in making an efficient system design and investing wisely for documented returns.
Certify your building
Today the prime focus is on overall buildings performance which includes
design, construction, efficiency, sustainability and the environmental impact
of buildings in the future.
Energy efficient products form part of this overall plan. In many countries
around the world the evaluation of high performance buildings falls under the
banner LEED. Danfoss drives help you to reduce the energy consumption in your
building and to fulfill the highest standards set by these certification
bodies.
Ideal for simple fans, pumps, and compressors
User-friendly, distributed intelligence and reduced power consumption are beneficial for fan applications. Basic AHU functions enable the VLT® HVAC Basic Drive to control a wide range of functions. Pump-specific features developed in cooperation with OEMs, contractors and manufacturers around the world.
Fire Override Mode
Fire Override Mode prevents the VLT® HVAC Basic Drive from stopping for self-
protecting reasons. In this mode it will continue vital fan operation
regardless of control signals, warnings or alarms.
Fire Override Mode helps keep fire escape routes free of smoke and ensures
secure and continued operation within applications such as stair-well
pressurization, car park exhaust fans, smoke exhaust and essential service
functions.
Fire mode is clearly indicated on the display to prevent any confusion. When
set, the drive will override self protection and will continue operation
despite the possibility of permanent damage in case of over-heating or
overload. The vital goal is to keep the motor running even if it means self-
destruction.
Skip frequencies
By pressing a few buttons on the Local Control Panel the drive can be set to
avoid frequency bands at which connected fans create resonances in the
ventilation system. This reduces vibration, noises and wear on equipment.
No load / Broken Belt warning
Many fan applications are still operated by a belt. This function monitors
whether the belt is still in use, has ceased operation due to wear and tear.
The built-in maintenance program helps you to ensure belt inspection at
regular intervals.
Flying start
The drive can detect speed and direction of a freely spinning fan or pump and
“catch” it at the right speed.
This feature prevents violent starts and tear on the equipment.
Sleep Mode
In situations with low or no flow, the drive enters sleep mode to conserve
energy. When the pressure falls below the pre-defined setpoint, the drive
starts automatically. Compared to continuous operation this method reduces
energy costs and equipment wear and tear, extending the lifetime of the
application.
Sensorless pump control
Eliminate the need for external pressure transmitters, using this drive.
The drive delivers sensorless pump control, meaning no external pressure
transmitter is required.
Constant torque for air compressors
The drive has a dedicated constant torque mode for air compressor
applications.
Quiet operation
Direct control of the cooling fan ensures that the drive operates as quietly
as possible. The cooling fan adjusts precisely to the load, for optimum
efficiency and energy savings.
Simple timer function
There is no need for an external timer, since you can use the integrated timer
in the drive. This simple timer function is useful for testing the motor, for
example in Fire Mode applications.
Use the motor of your choice
VLT® HVAC Basic Drive FC 101 is equally compatible with induction and
permanent magnet (PM) motors for the full power range. There is no need to
change out motor type when retrofitting the drive.
More robust when power is unstable
Voltage dips or power interruptions in the grid cause huge problems in your
systems. It is reassuring to know that integrated power loss ride-through
capability in the drive ensures more stable and robust operation.
Voltage sag immunity
With Semi 47 certification, you can be sure that this drive is performs
robustly, whatever the quality of the power supply.
Improved power factor with VLT® Advanced Harmonic Filter AHF 010
Are you using VLT® Advanced Harmonic Filter AHF 010 to mitigate harmonics?
Use the relay output on the drive to control this passive harmonic filter, to
achieve a higher power factor at zero load or partial load.
VLT® HVAC Basic Drive
The VLT® HVAC Basic Drive is a competitive drive for simple applications – with basic needs.
Easy commissioning
The Quick Menu wizard makes it easy to set up and operate the drive.
In situations where there is no mains power, use the VLT® Mains-Free Interface
tool. It gives you an easy way to configure drives on the production line, and
saves time and effort for installation and service technicians.
Maintenance free
Due to a series of self-protecting and monitoring features, the VLT® HVAC
Basic Drive is maintenance free, except for general cleaning.
Replacement of internal fans or capacitors is normally not required during
lifetime.
Save space
Due to its ultra compact design, the VLT® HVAC Basic Drive is easily mounted
inside a HVAC unit or panel, reducing overall enclosure costs.
Built-in mains filters
The standard integrated DC coils comply with EN 61000-3-12 reducing losses in
mains and ensuring reliable operation in the whole grid. The DC coils increase
the lifespan of the DC link capacitors and they also ensure that the drive can
operate motors to their full performance. Integrated DC coils save the cost
for adding external filters.
Reduced installation costs
- Built-in HVAC functions reducing need for other system components
- Ease of installation and set-up
Competitive performance
- Up to 98.5% efficiency
- Automatic Energy Optimisation
- System diagnostics
VLT® HVAC Basic Drive
The VLT® HVAC Basic Drive is a competitive drive for simple applications –
with basic needs.
Categories according
VLT® HVAC Basic Drive product range:
- 3 x 200 – 240 V……………. 0.25 – 45 kW
- 3 x 380 – 480 V……………. 0.37 – 90 kW
- 3 x 525 – 600 V……………. 2.2 – 90 kW
Available enclosure ratings:
- IP 20
- IP 21/UL Type 1 (separate option kit)
- IP 54
Intuitive control panel
- 2-line alphanumeric display
- 7 languages + numeric menu
- Status LED’s
- Quick menus (wizard for open loop applications, closed loop applications, and motor setup)
- IP 54 when mounted in a panel front
- Password protection
- Same parameter structure as the Danfoss VLT® FC – family drives
- Removable under operation (IP20)
- Upload and download parameters (LCP copy function)
- VLT® Control Panel LCP 32 makes it easier to program the drive, with a choice of five languages in the display.
Comparision of limits EN 55011/61800-3
The built-in EMC filter makes the VLT® HVAC Basic Drive conform to the limits for category C1 and C2 according to EN 61800-3, with no additional external components needed, even with long motor cables.
However, more importantly in practice is the compliance with the environmental standard EN 55011, Class B (residential) and Class A1 (industrial). This ensures reliable system operation in full compliance with all requirements for EMC in the operating environments and eliminates required product warnings and restrictions prescribed by the standard, if the drive used does not conform to category C1.
Enclosure protection options
IP 20,Type1/IP21, IP54 enclosures
The installation volume and/or the mounting surfaces are minimized.
The functional sections nevertheless fulfil the highest requirements even for applications with ambient temperatures up to 50° C.
Compact design
Optimized efficiency and intelligent cooling technology ensure compact and
service-friendly design.
Supplementary equipment such as EMC filters and harmonics suppression are
integrated into the ultra compact enclosure.
Save installation time
The IP 20, Type 1/IP 21 (with option) and IP 54 series is designed for easy
accessibility and time-saving installation. Mechanical fastening points are
easy to access from the front even with automatic tools. All terminals are
sufficiently dimensioned and clearly marked behind a plate. Accessories for
bonding screened cables are included making compact enclosures easier to
install.
Freedom to change settings prior to installation
VLT® Mains-free Interface
Did you know you can change the settings of the FC 101 drive with no
connection to mains power supply? Just connect to a PC using the VLT® Mains-
free Interface.
The VLT® Mains-free Interface connects to the PC via a USB 2.0 interface.
A Mini-B USB connector is located at the front, and a standard drive connector
is located on the back. Both the VLT® Mains-free Interface and the drive get a
supply of current from the USB ports on the PC.
For drive enclosure sizes H1–H5 and I2–I4:
The required current is within the standard capability of a single USB port.
Use a single USB type A connector.
For drive enclosure sizes H6–H10 and I6–I8:
More than 500 mA current is required (500 mA is the maximum standard current a
USB port can deliver).
Connect to the PC using a double USB type A cable.
The drive obtains the required current via both of the USB ports. The second
USB port is marked “Auxiliary power only”.
Technical data
Main supply (L1, L2, L3)
Supply voltage| 200 – 240 V ±10%
Supply voltage| 380 – 480 V ±10%
Supply voltage| 525 – 600 V ±10%
Supply frequency| 50/60 Hz
Displacement power factor (cos ф)| > 0.98 (near unity)
Switching on input supply L1, L2, L3| 1–2 times/min.
Harmonic disturbance| Meets EN 61000-3-12
Output data (U, V, W)
Output voltage| 0 – 100% of supply voltage
Output frequency| 0 – 400 Hz
Switching on output| Unlimited
Ramp-up and -down times| 1 – 3600 sec.
Digital inputs
Programmable digital inputs| 4
Logic| PNP or NPN programable
Voltage level| 0 – 24 V DC
Maximum voltage on input| 28 V DC
Input resistance, Ri| Approx. 4 kΩ
Analog inputs
Analog inputs| 2
Modes| Voltage or current
Voltage level| 0 to +10 V (scaleable)
Current level| 0/4 to 20 mA (scaleable)
Accuracy of analog inputs| Max. error: 0.5% of full scale
Analog output
Programmable analog outputs| 2
Current range at analog output| 0/4 – 20 mA
Max. load to common at analog output (terminal 30)| 500 Ω
Accuracy on analog output| Max. error: 1% of full scale
Analog outputs can be used as digital outputs
Control card
RS485 interface| Up to 115 kBaud
Max. load (10 V)| 25 mA
Max. load (24 V)| 80 mA
Relay output
Programmable relay outputs| 2
Max. terminal load (AC) on 1-3 (break), 1-2 (make)| 240 VAC, 2 A and 400 VAC,
2 A
Surroundings/external
Enclosure
| IP 20/Chassis
(IP 21/Type 1 optional kit)
IP 54
Vibration test| 1.14 g
Max. relative humidity| 5% – 95% (IEC 721-3-3; Class 3K3
(non-condensing) during operation
Ambient temperature| up to 50° C
Galvanic isolation of all| I/O supplies according to PELV
Aggressive environment| Designed for coated/uncoated 3C3/3C2 (IEC 60721-3-3)
Fieldbus communication
Standard built-in:
| BACnet Modbus RTU N2 Metasys FLN Apogee FC Protocol
Protection mode for longest possible up-time
– Electronic thermal motor protection against overload
– Temperature monitoring of the heatsink ensures that the frequency converter
trips if the temperature reaches 95° C ± 5° C.
– The frequency converter is protected against short-circuits on motor
terminals U, V, W.
– The frequency converter is protected against earth faults on motor terminals
U, V, W.
– Protection against mains phase loss
Compliance
Semi 47 certified for voltage sag immunity compliance
Electrical data – H and I enclosures
200 – 240 VAC
Enclosure
200 – 240 VAC
| IP 20/Chassis| H1| H2| H3| H4| H5
---|---|---|---|---|---|---
| PK25| PK37| PK75| P1K5| P2K2| P3K7| P5K5|
P7K5| P11K
Typical Shaft Output| [kW]| 0.25| 0.37| 0.75| 1.5| 2.2| 3.7| 5.5| 7.5|
11
[HP]| 0.33| 0.5| 1| 2| 3| 5| 7.5| 10| 15
Output Current
(3 x 200 – 240 V)
| Continuous| [A]| 1.5| 2.2| 4.2| 6.8| 9.6| 15.2| 22| 28| 42
Intermittent| [A]| 1.7| 2.4| 4.6| 7.5| 10.6| 16.7| 24.2| 30.8| 46.2
Max. cable size
Mains, motor
| [mm2] ([AWG])| 4/10| 16/6
Max. Input Current
(3 x 200 – 240 V)
| Continuous| ** [A]| 1.1| 1.6| 2.8| 5.6| 8.8/7.2| 14.1/12| 21/18| 28.3/24|
41/38.2
Intermittent| 1.2| 1.8| 3.1| 6.2| 9.5/7.9| 15.5/13.2| 23.1/19.8| 31.1/26.4|
45.1/42
Environment
Estimated power loss at rated max. load, best case| [W]| 12| 15| 21| 48|
80| 97| 182| 230| 369
typically| | 14| 18| 26| 60| 182| 120| 204| 268| 386
Weight| [kg]| 2.0| 2.1| 3.4| 4.5| 7.9| 9.5
Efficiency [%], best case| 97.0| 97.3| 98.0| 97.6| 97.1| 97.9| 97.3|
97.5| 97.2
typically| 96.5| 96.8| 97.6| 97.0| 96.3| 97.4| 97| 97.1
Enclosure| IP 20/Chassis| H6| H7| H8
---|---|---|---|---
200 – 240 VAC| | P15K| P18K| P22K| P30K| P37K|
P45K**
Typical Shaft Output
| [kW]| 15.0| 18.5| 22.0| 30.0| 37.0| 45.0
[HP]| 20.0| 25.0| 30.0| 40.0| 50.0| 60.0
Output Current
(3 x 200 – 240 V)
| Continuous| [A]| 59.4| 74.8| 88.0| 115.0| 143.0| 170.0
Intermittent| [A]| 65.3| 82.3| 96.8| 126.5| 157.3| 187.0
Max. cable size
Mains, motor
| [mm2] ([AWG])| 35/2| 50/1| 95/0| 120/(4/0)
Max. Input Current
(3 x 200 – 240 V)
| Continuous| ****
[A]| 52.7| 65.0| 76.0| 103.7| 127.9| 153.0
Intermittent| 58.0| 71.5| 83.7| 114.1| 140.7| 168.3
Environment
Estimated power loss at rated max. load, best case| [W]| 512| 658| 804|
1015| 1459| 1350
Weight| [kg]| 24.5| 36.0| 51.0
Efficiency [%], best case| 97.0| 96.9| 96.8| 97.0| 96.5| 97.3
380 – 480 VAC
Enclosure 380-480 VAC
| IP 20/Chassis| H1| H2| H3
---|---|---|---|---
IP 54| NA| I2| I3
| PK37| PK75| P1K5| P2K2| P3K0| P4K0| P5K5|
P7K5
Typical Shaft Output
| [kW]| 0.37| 0.75| 1.5| 2.2| 3| 4| 5.5| 7.5
[HP]| 0.5| 1| 2| 3| 4| 5| 7.5| 10
Output Current
(3 x 380-440 V)
| Continuous| ** [A]| 1.2| 2.2| 3.7| 5.3| 7.2| 9.1| 12| 15.5
Intermittent [1 min. max]| 1.3| 2.4| 4.1| 5.8| 7.9| 9.9| 13.2| 17.1
Output Current**
(3 x 440-480 V)
| Continuous| ** [A]| 1.1| 2.1| 3.4| 4.8| 6.3| 8.2| 11| 14
Intermittent [1 min. max]| 1.2| 2.3| 3.7| 5.3| 6.9| 9.0| 12.1| 15.4
Max. cable size**
Mains, motor
| IP 20| [mm2] ([AWG])| ****
4/10
IP 54
Max. Input Current
(3 x 380-440 V)
| Continuous| ** [A]| 1.2| 2.1| 3.5| 4.7| 6.3| 8.3| 11.2| 15.1
Intermittent [1 min. max]| 1.3| 2.3| 3.9| 5.2| 6.9| 9.1| 12.3| 16.6
Max. Input Current**
(3 x 440-480 V)
| Continuous| ** [A]| 1.0| 1.8| 2.9| 3.9| 5.3| 6.8| 9.4| 12.6
Intermittent [1 min. max]| 1.1| 2| 3.2| 4.3| 5.8| 7.5| 10.3| 13.9
Environment
Estimated power loss at rated max. load**| [W]| 13| 21| 46| 46| 66| 95|
104| 159
Weight
| IP 20| ** [kg]| 2.0| 2.1| 3.3| 3.4| 4.3| 4.5
IP 54| | 5.3| 7.2
Efficiency [%]**| 97.8| 98.0| 97.7| 98.3| 98.2| 98.0| 98.4| 98.2
Enclosure 380-480 VAC
| IP 20/Chassis| H4| H5| H6| H7| H8
---|---|---|---|---|---|---
IP 54| I4| I6| I7| I8
| P11K| P15K| P18K| P22K| P30K| P37K| P45K|
P55K| P75K| P90K
Typical Shaft Output
| [kW]| 11| 15| 18| 22| 30| 37| 45| 55| 75| 90
[HP]| 15| 20| 25| 30| 40| 50| 60| 75| 100| 125
Output Current
(3 x 380-440 V)
| Continuous| ** [A]| 23| 31| 37| 42.5| 61| 73| 90| 106| 147| 177
Intermittent [1 min. max]| 25.3| 34| 40.7| 46.8| 67.1| 80.3| 99| 116| 161| 194
Output Current**
(3 x 440-480 V)
| Continuous| ** [A]| 21| 27| 34| 40| 52| 65| 80| 105| 130| 160
Intermittent [1 min. max]| 23.1| 29.7| 37.4| 44| 57.2| 71.5| 88| 115| 143| 176
Max. cable size**
Mains, motor
| IP 20| [mm2] ([AWG])| 16/6| 35/2| 50/1| 95/0| 120/250
IP 54| 10/7| 35/2| 50/1| 95/(3/0)| 120/(4/0)
Max. Input Current
(3 x 380-440 V)
| Continuous| ** [A]| 22.1| 29.9| 35.2| 41.5| 57| 70| 84| 103| 140| 166
Intermittent [1 min. max]| 24.3| 32.9| 38.7| 45.7| 62.7| 77| 92.4| 113| 154|
182
Max. Input Current**
(3 x 440-480 V)
| Continuous| ** [A]| 18.4| 24.7| 29.3| 34.6| 49-46| 61-57| 73-68| 89-83|
121-113| 143-133
Intermittent [1 min. max]| 20.2| 27.2| 32.2| 38.1| 54-50| 67-62| 80-74| 98-91|
133-124| 157-146
Environment**
Weight
| IP 20| ** [kg]| 7.9| 9.5| 24.5| 36| 51
IP 54| 13.8| 27| 45| 65
Efficiency**| [%]| 98.1| 98.0| 98.1| 98.1| 97.8| 97.9| 97.1| 98.3| 98.3|
98.3
525 – 600 VAC
Enclosure
525 – 600 VAC
| IP 20/Chassis| H9| H10| H6
---|---|---|---|---
| P2K2| P3K0| P5K5| P7K5| P11K| P15K| P22K|
P30K
Typical Shaft Output
| [kW]| 2.2| 3.0| 5.5| 7.5| 11.0| 15.0| 22.0| 30.0
[HP]| 3.0| 4.0| 7.5| 10.0| 15.0| 20.0| 30.0| 40.0
Output Current
(3 x 525 – 550 V)
| Continuous| ** [A]| 4.1| 5.2| 9.5| 11.5| 19.0| 23.0| 36.0| 43.0
Intermittent| 4.5| 5.7| 10.5| 12.7| 20.9| 25.3| 39.6| 47.3
Output Current**
(3 x 551 – 600 V)
| Continuous| ** [A]| 3.9| 4.9| 9.0| 11.0| 18.0| 22.0| 34.0| 41.0
Intermittent| 4.3| 5.4| 9.9| 12.1| 19.8| 24.2| 37.4| 45.1
Max. cable size**
Mains, motor
| [mm2] ([AWG])| 4/10| 10/8| 35/2
Max. Input Current
(3 x 525 – 550 V)
| Continuous| ** [A]| 3.7| 5.1| 8.7| 11.9| 16.5| 22.5| 33.1| 45.1
Intermittent| 4.1| 5.6| 9.6| 13.1| 18.2| 24.8| 36.4| 49.6
Max. Input Current**
(3 x 551 – 600 V)
| Continuous| ** [A]| 3.5| 4.8| 8.3| 11.4| 15.7| 21.4| 31.5| 42.9
Intermittent| 3.9| 5.3| 9.2| 12.5| 17.3| 23.6| 34.6| 47.2
Environment
Estimated power loss at rated max. load| [W]| 8.4| 112.0| 178.0| 239.0|
360.0| 503.0| 607.0| 820.0
Weight| [kg]| 6.6| 11.5| 24.5
Efficiency [%]| 97.0| 97.5
Enclosure**
525 – 600 VAC
| IP 20/Chassis| H7| H8
---|---|---|---
| P45K| P55K| P75K| P90K
Typical Shaft Output
| [kW]| 45.0| 55.0| 75.0| 90.0
[HP]| 60.0| 70.0| 100.0| 125.0
Output Current
(3 x 525 – 550 V)
| Continuous| ** [A]| 65.0| 87.0| 105.0| 137.0
Intermittent| 71.5| 95.7| 115.5| 150.7
Output Current**
(3 x 551 – 600 V)
| Continuous| ** [A]| 62.0| 83.0| 100.0| 131.0
Intermittent| 68.2| 91.3| 110.0| 144.1
Max. cable size**
Mains, motor
| [mm2] ([AWG])| 50/1| 95/0| 120/ (4/0)
Max. Input Current
(3 x 525 – 550 V)
| Continuous| ** [A]| 66.5| 81.3| 109.0| 130.9
Intermittent| 73.1| 89.4| 119.9| 143.9
Max. Input Current**
(3 x 551 – 600 V)
| Continuous| ** [A]| 63.3| 77.4| 103.8| 124.5
Intermittent| 69.6| 85.1| 114.2| 137.0
Environment
Estimated power loss at rated max. load| [W]| 972.0| 1182.0| 1281.0|
1437.0
Weight| [kg]| 36.0| 51.0
Efficiency [%]**| 98.0| 98.4| 98.5
Accessories
IP 21/ Type 1 Kit
The IP 21/ Type 1 kit is used for installation of VLT® HVAC Basic Drives in
dry environments where dripping water can occour. The enclosure kits are
available for all frame sizes.
- PG 16 and PG 21 holes for cable glands
LCP Panel Mounting Kit
For easy installation of the local control panel in a cabinet door.
- IP 54 (front)
- Thumb screws for tool-free installation
- ncl. 3 meters of cables in industry quality (also available separately)
- Easy to install
Ordering number LCP & kit
-
132B0201 (Mounting kit for LCPi ncluding fasteners, 3 m cable and gasket).
-
132B0200 Alpha-numeric VLT® Control Panel LCP 31 – to be ordered separately for IP20 units – it is delivered as standard for IP 54 units).
-
132B9221
VLT® Control Panel LCP 32
Graphical local control panel with choice of 5 languages: English, Chinese, French, German, or Spanish -
132B0203
FC 101 LCP RJ 45 Plug Converter
This plug converter enables you to easily extend the cable for remote mounting. Minimum order quantity is 12 sets (1 box).
VLT® Mains-Free Interface
- 132B9222
Use this USB 2.0 based programming interface for PC programming of the drives, with no need for mains power.
Set parameters and flash firmware.
Use this interface together with VLT® Motion Control Tool MCT 10.
Ordering codes IP21/ Type 1 kit
Enclosure | IP 21 kit | UL Type 1 kit | Decoupling plate |
---|---|---|---|
H1 | 132B0212 | 132B0222 | 132B0202 |
H2 | 132B0213 | 132B0223 | 132B0202 |
H3 | 132B0214 | 132B0224 | 132B0204 |
H4 | 132B0215 | 132B0225 | 132B0205 |
H5 | 132B0216 | 132B0226 | 132B0205 |
H6 | 132B0217 | 132B0217 | 132B0207 |
H6 | 132B0217 | 132B0227 | 132B0242 |
H7 | 132B0218 | 132B0218 | 132B0208 |
H7 | 132B0218 | 132B0218 | 132B0243 |
H8 | 132B0219 | 132B0219 | 132B0209 |
Minimize energy usage while maximizing comfort levels with VLT® HVAC Basic Drive
The VLT® HVAC Basic Drive is installed on a broad range of heating, ventilation and air conditioning applications in new and existing buildings and infrastructural systems all over the world.
VLT® drives enhance air quality and indoor comfort levels, improve control and save energy, ensure better asset protection, reduce maintenance costs and increase reliability
The daily load variation in HVAC facilities is considerable. Variable speed control of electrical motors has proved to be one of the most effective costreducing measures available.
VLT® drive delivers reliable, low-energy ventilation for 40 years
Learn how the compact VLT® HVAC Basic Drive FC 101 was installed in an
industrial kitchen.
It replaced a VLT® 5 drive, to reduce electricity consumption by 390 MWh each
year.
Read the case story
Discover more case stories for the HVAC industry here:
http://drives.danfoss.com/industries/hvac/case-stories/#/
Follow us and learn more about AC drives
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>