zens PuK 2 Built In Wireless Charger Installation Guide

June 3, 2024
ZeNS

zens PuK 2 Built In Wireless Charger Installation Guide
zens PuK 2 Built In Wireless Charger

Safety instructions

  • Failure to comply with these instructions may result in damage to the device, fire, or other hazards.
  • During the charging process, magnetic fields are generated which may affect pacemakers or other implanted devices. Contact the manufacturer of the implant before commissioning/using the device.
  • These instructions are an integral component of the product and must be retained by the end user.

Usage instructions

  • Only suitable for indoor applications.
  • Suitable for surface or sub-surface installation.
  • When installing as a surface charger, please use PuK 2 wireless charger only with top plate.
  • When installing the PuK 2 wireless charger sub-surface, please install under at least 2 mm. and at most 3 mm. material.
  • Not suitable for sub-surface installation in metallic materials or materials with a metallic coating.
  • Care must be taken to ensure that no metallic objects are lying on the wireless charger.
  • Only use the original power adapter supplied with the charger.
  • Do not use any extension cables.

Compatibility

The PuK 2 wireless charger is compatible with Qi certified devices and with most lightweight cases (< 3 mm).
Any cases with metal inside (e.g. magnets, bankcards, etc.) or a metal lining need to be removed before charging.

Included items

Included items Included
items

Included items Included
items

  • PuK 2 wireless charger
  • Top plate for surface installation
  • Power supply with DC plug interface
  • Mounting set* for installation (screws and self-adhesive clips)
  • Mold for installation

Installation location selection

When selecting the installation location, make sure:

  • There is enough room to place devices on the charging point.
  • There are no sources of water or other fluids nearby.
  • There are no metallic objects nearby.
  • There are no heat sources nearby.
  • The material thickness of the mounting surface is adequate in the case of sub surface installation (see page 4).

Sub-surface installation

Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation
Sub-surface installation

  1. Use the mold to mark the position of the PuK 2 wireless charger.
  2. Make a sub-surface recess of Ø 81 mm. into the mounting surface from below. When implementing the sub-surface recess make sure that:
    • The depth of the recess is at least 16 mm. so the clamping lugs can clamp the charging unit sufficiently.
    • The thickness of the remaining material over the recess does not exceed the minimum of 2 mm. and the maximum of 3 mm. (see page 4).
  3. Insert the PuK 2 wireless charger (A) straight into the recess from below. Make sure no open space is left between the PuK and the top surface (see page 6).
  4. The PuK 2 wireless charger can be fixated in place by inserting the two enclosed screws into the grooved clamping lugs. Fasten the screws carefully until the clamping lugs grip on th edges of the opening.
  5. Use the self-adhesive cable clips to secure the cable.
  6. Measure the exact center point of the recess. Place the sticker exactly in the center position on the top surface above the recess to indicate the charging point (see page 10).
  7. Connect the charger cable to the power adapter and plug the adapter into the nearest, suitable power socket.

Surface installation

Surface installation
Surface installation
Surface installation
Surface installation

Surface installation
Surface installation
Surface installation
Surface installation

  1. Use the mold to mark the position of the PuK 2 wireless charger.
  2. Make an opening of Ø 81 mm. in the mounting surface.
  3. Place top plate (B) onto the PuK 2 wireless charger (A) and gently press down until it snaps into place.
  4. Insert the PuK 2 wireless charger with attached top plate from above into the opening and press down gently. Optional: remove the protective film from the self-adhesive edge on the bottom of the top plate (B) before placing the PuK 2 wireless charger in the opening.
  5. The PuK 2 wireless charger can be fixated in place by inserting the two enclosed screws into the grooved clamping lugs. Fasten the screws carefully until the clamping lugs grip on the edges of the opening.
  6. Use the self-adhesive cable clips to secure the cable.
  7. Connect the charger cable to the power adapter and plug the adapter into the nearest, suitable power socket.

Charging a device

  • The PuK 2 wireless charger may only be used to charge Qi compatible devices.

  • Place the device on the charging point, indicated by the top plate (B) or sticker (C), in such a way the receiving coil is positioned centrally on the wireless charger.

  • The device displays the charging progress.

  • The position of the charging system in the device may vary depending on the manufacturer and model.
    Please observe the instructions of the device. If charging does not work, keep adjusting the position of the device until the device displays the charging process.

  • The charging process may result in the device getting slightly warm.

Cleaning the top plate

  • Unplug the power adapter from the socket outlet.
  • Wipe the top plate (B) with a slightly damp, lint-free cloth.
  • Do not allow any moisture to get into the device.
  • Dry the top plate (B) completely with a dry cloth.
  • Plug the power adapter back into the socket outlet.

Technical data – power adapter

Input voltage: 100 … 240 V AC
Frequency: 50/60 Hz
Output voltage: 15.0 V DC +/- 5 %
Output current: (max) 1.6 A DC
Power consumption (standby): < 0.3 W
Energy efficiency class: V
Cable length: 1.8 m

Product dimensions

Diameter: 80 mm.
Height: 21 mm.
Height of top plate: 1.7 mm.
Cable length: 1.8 m

Certification and ratings

Water resistance rating (top plate): IP-43
Qi certification ID: 9296

RoHS directive 2011/65/EU

(amendment directives (EU) 2015/863.
EU Regulation (EC) No 1907/2006 (REACH)

Technical data – wireless charger

Input current: 1.5 A
Input voltage: 15 V / +/- 1,5 %
Switching frequency: 110 … 125 kHz
Charging capacity: max. 15 W, Qi certified devices
Operating temperature: 10 … 35 °C
Storage temperature: -20 … +70 °C

Installation dimensions

Diameter of built-in/sub-surface opening: 81 mm.
Depth of the sub-surface recess: min. 16 mm.
Material thickness of left over surface above recess:
min. 2 mm., max. 3 mm.

Directives

Radio Equipment Directive 2014/53/EU
ETSI EN 303 417 V1.1.1 (2017-09)
ETSI EN 301 489-1 V2.2.3 (2019-11)
ETSI EN 301 489-3 V2.1.2 (2021-03)
EN 50364:2018
EN 62368-1:2020+ A11:2020
FCC Part 18

Europa
Europe
Simplified Declaration of Conformity
Hereby, Zens Consumer B.V. and Zens Electronics B.V. declares that the radio equipment device ZETC09N/00 is in compliance with the Directive 2014/53/EU (CE-RED) and Directive 2011/65/EU (RoHS).
The full text of the EU declaration of conformity is available at the following internet address: www.makezens.com/mediaroom/products.

North America – FCC statement

DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY
Hereby, Zens Consumers B.V. and Zens Electronics B.V. declare that the device, ZETC09N/00 complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC interference statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC radiation exposure statement
The device shall be used in such a manner that the potential for human contact normal operation is minimized.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
FCC Caution: any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Radio Frequency range: 127.795 kHz
Max RF power in frequency band: 102.48 dBuA/m

Zens B.V.
High Tech Campus 85
5656 AG Eindhoven, The Netherlands
Phone: +31 40 218 0088
www.makezens.com

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZeNS User Manuals

Related Manuals