KICKASS KABTRYSHUNT-V0.9 12V Battery Monitor with 500A Shunt User Manual
- June 1, 2024
- KICKASS
Table of Contents
- KICKASS KABTRYSHUNT-V0.9 12V Battery Monitor with 500A Shunt
- Installation
- WHY KICKASS?
- OVERVIEW
- INCLUDED PARTS
- OPTIONAL ACCESSORIES
- PRODUCT OVERVIEW
- SPECIFICATIONS
- INSTALLATION
- SETUP
- Recommended Values for Different Battery Types
- OPERATION
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KICKASS KABTRYSHUNT-V0.9 12V Battery Monitor with 500A Shunt
Specifications
- Working Voltage Range: 12V
- Working current (backlight on): Not specified
- Standby current (backlight off): Not specified
- Accuracy: Not specified
- Battery Capacity Range: Not specified
- Operating Temperature Range: Not specified
- Display Housing Dimensions: Not specified
- B+ Wire: Included
- Display Temperature Sensor Cable: Included
- Display Data Cable: Included
- Shunt Assembly Data Cable: Included
- Optional extension cable wire length: 5m
Installation
Fitting Shunt Assembly
The shunt can be connected to a battery in two ways:
Option 1 – Direct to Battery
- Remove the bolts from the shunt assembly and discard the shunt holder.
- Attach the shunt side labeled B- to the negative battery terminal using the included M8 bolt, washers, and nut.
- Fit the B+ Wire by inserting the exposed conductor end into the small green terminal block located on the shunt (labeled B+).
- Connect the ring terminal to the battery positive pole along with the system positive loads.
Option 2 – Fit Shunt Assembly Using Holder
The shunt can be mounted to a flat surface using any of the pre-drilled holes in the shunt holder.
FAQ
Q: What is the purpose of the Battery Monitor Display?
A: The Battery Monitor Display provides information on battery state of
charge, instantaneous current flow, battery voltage, ambient temperature,
remaining time to full/empty calculations, and low battery/SOC alarms.
CONGRATULATIONS ON PURCHASING YOUR NEW
KICKASS 12V BATTERY MONITOR WITH 500A SHUNT
WHY KICKASS?
KickAss is focussed on bringing the luxury of home to the outdoors. Your one stop shop for 12V products. All of our products are designed to be plug and play for the ultimate camping experience.
OVERVIEW
The KickAss Battery Monitor with 500A Shunt includes the following features:
- Battery State of Charge (SOC %).
- Instantaneous current (A) flow, positive when charging, negative when discharging
- Battery voltage
- Ambient temperature
- Remaining time to full/empty calculations
- Low battery / Low SOC alarm – Audible alarm can be muted
- Remote Display with back lit LCD screen
WARNINGS
- Please read and understand the product user manual and warnings carefully before installing and operating.
- Any 12V installation work should be done by a professional, failing to do this may result in damage to your unit or vehicle.
- Ensure suitable gauge wiring is used.
- It is the customers responsibility to ensure that all components are safely and correctly installed.
- Disassembling the device may void warranty.
- Do not expose the display to excessive moisture or dust.
- Do not expose the display screen to excessive sunlight, doing so may shorten the lifespan of the LCD.
INCLUDED PARTS
OPTIONAL ACCESSORIES
KA recommends using the 5M (RDU) extension cable to remotely mount your
Battery Monitor Display.
SKU: KARDUEXT5M
PRODUCT OVERVIEW
SPECIFICATIONS
Description | Parameter |
---|---|
Working Voltage Range | 10-30V DC |
Working current (backlight on) | ~100 mA |
Standby current (backlight off) | ~1-2 mA |
Accuracy | 1% |
Battery Capacity Range | 0.1 – 999.9Ah |
Operating Temperature Range | -10º to 60º |
Display Housing Dimensions | 126L x 66.6H |
B+ Wire | 20AWG, Length: 100mm |
Display Temperature Sensor Cable | 5m |
Display Data Cable | 25cm |
Shunt Assembly Data Cable | 35cm |
Optional extension cable wire length | Recommended 5m Extension Cable |
INSTALLATION
Fitting Shunt Assembly
The shunt can be connected to a battery in two ways, bolted directly to the
negative battery terminal or connected via a short wire to the negative
terminal.
-
Option 1 – Direct to Battery
-
To bolt the shunt directly to the battery terminal, remove the bolts from the shunt assembly and discard the shunt holder.
-
Using the included M8 bolt, washers and nut, attach the shunt side labeled “B-” to the negative battery terminal.
-
Fit the B+ Wire by inserting the exposed conductor end into the small green terminal block located on the shunt. This is labeled B+. Tighten down the the terminal block screw with a 2.4mm flat head screw driver.
-
Now fit the ring terminal to the battery positive pole, along with the system positive loads.
-
Option 2 – Fit shunt assembly using holder
-
The shunt can be mounted to a flat surface using any of the pre drilled holes in the shunt holder.
-
Connect a cable assembly using M8 ring terminals and a minimum of 25mmsq wire, to the shunt side labeled “B-“. The cable assembly should be maximum of 300mm long. Connect the other side of the cable assembly to the battery Negative terminal.
-
Follow steps 3 and 4 as above.
CAUTION
- Please check all connections are correctly terminated and secured tightly!
- Ensure the B+ Wire is fitted using circuit protection: Split conduit or an in-line fuse rated at 3A will be suitable.
Connecting Display to the Shunt Assembly
The Battery Monitor Display can be connected to the Shunt, with the provided
cables. To do this firstly connect the data cable to the shunt assembly by
plugging in the small white 5 pin connector, now connect the two round black
connectors to join the display and shunt together. The Temperature sensors can
now be run to the battery or desired location for ambient temperature reading.
Connecting Loads
and Chargers to Shunt Assembly
When connecting loads and chargers to the battery using the Shunt, system
negative connections must be connected to the P-side of the Shunt Assembly. No
negative connections should be made directly to the battery terminal as this
will cause the battery monitor to provide false readings. When wiring
batteries in parallel, ensure the correct connection configuration is used.
Please refer to diagram.
CAUTION: Use a suitably rated Fuse/Circuit breaker for all loads. When using
the shunt in the parallel configuration, we recommend using an in-line fuse for
the B+ Wire. See diagram.
SETUP
Initial Setup
Before powering any system loads, the display must be calibrated to 100% SOC.
Do this by ensuring your battery bank is fully charged and the display is
showing 100%. To manually calibrate the SOC, press and hold the UP arrow for 3
seconds.
NOTE: The connected battery charger should be in the float stage before
manually calibrating the display.
Setting Parameters
To access the parameter setting menu, press and hold the OK button for
approximately 3 seconds.
The following screen will be displayed. The selected line will begin to flash, to navigate through each line use the up and down arrows. Click OK to select the parameter and then using the up and down arrows, set the values. Use the OK button to move the cursor to the left. The Back (<<) button can be used to exit out of the selected parameter and used again to close the settings menu.
Each of the following parameters will need to be set, below is a table which shows typical values for different battery types:
- CAP – Battery Capacity: The total capacity of the battery bank is measured in Ah and is the total capacity of your battery bank. For example: 2x 120AH batteries connected in parallel will total 240Ah.
- FCV – Full Cell Voltage: This parameter setting is the voltage point at which the battery is fully charged. When this voltage point is reach, the displayed SOC will calibrate to 100%. The system has now calculate that the battery bank is fully charged. It is recommended to set this value to the max charge voltage of your battery charger. Please check the manufactures specifications. NOTE: If calibration is off, see trouble shooting guide for details.
- LCA – Low Capacity Alarm: An audible alarm will sound when the remaining capacity is below this set value and the current (A) value will flash on the display. For lead acid batteries like AGM, it is recommend to set this value equal to or above the recommend usable capacity (50% of the total CAP). For example, a 120Ah AGM battery should be set to 60Ah or above.
- ZCV – Zero Cell Voltage: The zero cell voltage is the value point at which the battery bank is empty. Once this value has been reached, the SOC% will automatically reset to 0% and voltage display will flash. The audible alarm will also sound once per 10s if the load discharge the continues.
- NOTE: This value should be set just above the recommended minimum operating voltage of your battery type. For example, Lithium: 10~10.4V, AGM: 10.5~10.9V
- POV – Power Off Voltage: The power off voltage is the value point at which the display screen will turn off to save power. This will occur after 10s once the battery voltage is below this set value. To wake the screen up, press the OK button.
Recommended Values for Different Battery Types
Battery Type | GEL | AGM | WET | CALCIUM | LITHIUM |
---|---|---|---|---|---|
CAP | *Total rated capacity of battery bank. |
For example: A single @ 120Ah battery: CAP= 120Ah, 2x battery @ 120Ah: CAP= 240AH
FCV
(refer to charger spec)
| ****
14.1V
| ****
14.4-14.7V
| ****
14.7V
| ****
14.7V
| ****
14.4-14.6V
LCA| 50%-60% of CAP| 20%
ZCV| 10.8V| 10.5V
POV| 11.5V| 12V
- Rated Capacity – The capacity the battery is rated to by the manufacturer. For many battery types like AGM, it is not recommended to use 100% of the battery capacity.
- DOD: Depth of Discharge – The percentage at which the battery is discharged in relation to the rated capacity. eg. At 80% DOD, the State of Charge is approximately 20% of the total rated capacity of the battery.
- ATT Setting
Early versions of the KickAss Battery Monitor with 500A Shunt utilised an ATT value. If the ATT value is present in the configuration menu, please ensure this value is set to 0.
OPERATION
Backlight
The LCD is fitted with a Backlight. To turn on the Backlight, press the OK
button. The Backlight will time out and turn off after 60 seconds.
Alarm
The alarm will sound when the capacity of the battery goes below the set
value. This alarm can be muted by pressing the OK button.
Power off voltage
If the battery falls below the user set power off voltage (POV), the display
will turn off within 10 seconds. To view the display, press the OK button, the
display will turn off again after 10 seconds of inactivity.
SOC% Calibration
Manual Calibration is necessary on initial setup and after some time of use,
if the SOC% does not reach 100% under normal opratration. To do this simply
fully charge your battery and hold the UP arrow for 3 seconds. If the display
is frequently getting out of calibration, the user defined setting may require
review.
TROUBLESHOOTING
-
Q: Battery is discharging but the display is showing it is charging or vice versa.
A: It is likely the Shunt is wired back to front. Ensure the negative battery terminal is connected to the B- side of the shunt and loads/chargers are connected to the P- side of the shunt. -
Q: The display is not turning on.
A: Check to see all connection between display and shunt are fully connected, ensure dongle connection is screwed together.
A: Check to ensure that the red wire is connected to the positive terminal of the battery and to one of the two B+ points on the Shunt.
A: Press the OK button, if the display turns on than turns off again, it is likely the battery voltage is below the POV setting.
Q: The Displayed SOC% is not accurate. This could occur if the display shows 0% SOC before the system is at the correct DOD or the calibrating to 100% SOC is not occurring at the excepted time. For example, too early or not at all.
A: Check the CAP setting, this may need to be adjusted for the type of battery.
Review the FCV – The setting value for the max charging voltage may need to be reduced (100% not reached once charger is in float stage) or increased (100% reached before the charger has reached float stage).
Check ZCV – If 0% is reached too soon, this value needs to be increased and via versea. -
Q: What is the maximum current the shunt can monitor?
A: The shunt is rated to 500A continuous draw.