Autonics SPA-100-05 Switching Mode Power Supply User Guide

June 17, 2024
Autonics

Autonics SPA-100-05 Switching Mode Power Supply

Product Information

Product Name: Autonics Switching Mode Power Supply

Model Number: DRW171421AA

Series: SPA Series

Safety Considerations

Please observe the following safety considerations to ensure safe and proper operation of the product and to avoid hazards:

  • Warning: Failure to follow these instructions may result in serious injury or death.
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. Failure to follow this instruction may result in fire, personal injury, or economic loss.
2. Install on the device panel and ground to the F.G. terminal separately. Failure to follow this instruction may result in electric shock or fire.
3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in electric shock or fire.
4. Check ‘Wiring Diagram’ before wiring. Failure to follow this instruction may result in fire.
5. Do not disassemble or modify the unit. Failure to follow this instruction may result in electric shock o r fire.
  • Caution: Failure to follow these instructions may result in personal injury or product damage.
1. When connecting the F.G. terminal, use AWG 14 (2.1mm2) cable or over and tighten the terminal screw with a tightening torque of 0.7 to 0.9N.m. Failure to follow this instruction may result in fire or malfunction due to contact failure.
2. Use the unit within the rated specifications. Failure to follow this instruction may result in shortening the life cycle of the product, fire, or product damage.
3. Use a dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire.
4. Do not use the unit in a place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion.
5. Keep metal chips, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire product damage.
6. Do not touch the product during operation or for a certain period of time after stopping. Failure to follow this instruction may result in burns.
7. Upon the occurrence of an error, disconnect the power source. Failure to follow this instruction may result in fire or product damage.

Ordering Information

Specification of Input Cable

Model: SPA

Item Output Voltage Output Power
05 5VDC 30W
12 12VDC 50W
24 24VDC 75W

Specification of Input Cable AWG21 to 19

Model: SPA-030-05, SPA-030-12, SPA-050-12, SPA-075-12, SPA-030-24, SPA-050-24, SPA-075-24, SPA-100-24

Specification of Input Cable AWG18 to 16:

Model: SPA-050-05, SPA-075-05, SPA-100-05, SPA-100-12

FAQ

  • Q: Can I use water or organic solvents to clean the unit?
    • A : No, you should use a dry cloth to clean the unit. Using water or organic solvents may result in electric shock or fire.
  • Q: What should I do if an error occurs?
    • A : Disconnect the power source immediately upon the occurrence of an error to prevent fire or product damage.

Thank you for choosing our Autonics product. Please read the following safety considerations before use.

Safety Considerations

  • Please observe all safety considerations for safe and proper product operation to avoid hazards.
  • symbol represents caution due to special circumstances in which hazards may occur.
  • Warning : Failure to follow these instructions may result in serious injury or death.
  • Caution: Failure to follow these instructions may result in personal injury or product damage.

Warning

  1. Fail-safe device must be installed when using the unit with machinery that may  cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss.
  2. Install on the device panel, and ground to the F.G. terminal separately. Failure to follow this instruction may result in electric shock or fire.
  3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in electric shock or fire.
  4. Check ‘Wiring Diagram’ before wiring. Failure to follow this instruction may result in fire.
  5. Do not disassemble or modify the unit. Failure to follow this instruction may result in electric shock or fire.

Caution

  1. When connecting the F.G. terminal, use AWG 14 (2.1mm2) cable or over and tighten the terminal screw with a tightening torque of 0.7 to 0.9N.m. Failure to follow this instruction may result in fire or malfunction due to contact failure.
  2. Use the unit within the rated specifications. Failure to follow this instruction may result in shortening the life cycle of the product, fire, or product damage.
  3. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire.
  4. Do not use the unit in a place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion.
  5. Keep metal chip, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage.
  6. Do not touch the product during operation or for a certain period of time after stopping. Failure to follow this instruction may result in burns.
  7. Upon occurrence of an error, disconnect the power source. Failure to follow this instruction may result in fire or product damage.
  • The above specifications are subject to change and some models may be discontinued without notice.
  • Be sure to follow the cautions written in the instruction manual and the technical descriptions (catalog, homepage).

Ordering Information

Autonics-SPA-100-05-Switching-Mode-Power-Supply-FIG1

Specification of Input Cable

Autonics-SPA-100-05-Switching-Mode-Power-Supply-FIG3

Specifications

Autonics-SPA-100-05-Switching-Mode-Power-Supply-FIG2

Dimensions

Autonics-SPA-100-05-Switching-Mode-Power-Supply-FIG4

Wiring Diagram/Unit Description

  • Wiring Diagram
  1. Output voltage [+] terminal
  2. Output voltage [-] Terminal
  3. Frame ground [F.G.] terminal
  4. Input power [N] terminal
  5. Input power [L] terminal
  • Unit Description
    • A. Output indicator (green)
    • B. Output voltage adjuster (V.ADJ)

Over-Heating Protection

The overheat protection function cuts off the output voltage when the temperature in an element increases due to overheating. This product has an overheat protection function within itself.

When the overheat protection function is activated and the product does not work properly, please resupply power.

Cautions during Use

  1. Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
  2. Do not connect the output voltage either in serial or in parallel.
  3. Since there is no harmonic suppression or power factor correction circuit, install the circuit separately if necessary.
  4. Since using the condenser input method, the power factor is in the range of 0.4 to 0.6. When using a distribution board or transformer, check the capacity of the input voltage.Autonics-SPA-100-05-Switching-Mode-Power-Supply-FIG7
  5. Even though a noise filter is installed inside the product, the product can be affected by noise depending on the installation location or wiring
  6. If the internal fuse is damaged, please contact our A/S center.
  7. In the case of models using the user-switching method for the input voltage selection, the factory default is set to 220V. When switching over to 110V, remove the case of the product as below and select the voltage with the jumper switch within the range of the input voltage.
  8. To ensure the reliability of the product, install the product on the panel or metal surface.
  9. Install the unit in the well-ventilated place.
  10. Do not use near the equipment that generates strong magnetic force or high-frequency noise.
  11. This unit may be used in the following environments.
    • ①Indoors (in the environment condition rated in ‘Specifications’)
    • ②Altitude max. 2,000m
    • ③Pollution degree 2
    • ④Installation Category II

Major Products

  • Photoelectric Sensors
  • Fiber Optic Sensors
  • Door Sensors
  • Door Side Sensors
  • Area Sensors
  • Proximity Sensors
  • Pressure Sensors
  • Rotary Encoders
  • Connectors/Sockets
  • Switching Mode Power Supplies
  • Control Switches/Lamps/Buzzers
  • 1/0 Terminal Blocks & Cables
  • Stepper Motors/Drivers/Motion Controllers
  • Graphic/Logic Panels
  • Field Network Devices
  • Laser Marking System(Fiber, COz, Nd: YAG)
  • Laser Welding/Cutting System
  • Temperature Controllers
  • Temperature/Humidity Transducers
  • SSRs/Power Controllers
  • Counters
  • Timers
  • Panel Meters
  • Tachometer/Pulse(Rate) Meters
  • Display Units
  • Sensor Controllers

Autonics Corporation

HEADQUARTERS:

  • 18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South Korea, 48002
  • TEL : 82-51-519-3232
  • E-mail: sales@autonics.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Autonics User Manuals