WINLAND PS-110 Electronic Power Loss Monitor Instruction Manual

June 1, 2024
WINLAND

WINLAND-LOGO

WINLAND PS-110 Electronic Power Loss Monitor

Product Information

Specifications

  • Application: Contact Range Time Delay
  • Operating Range : Standard 2-prong 120V AC outlet
  • Weight : Not specified
  • Dimensions : Not specified
  • Mounting: Plug-in

Product Usage Instructions

Installation

  1. Plug the Electronic Power Loss Monitor into a standard 2-prong 120V AC outlet.
  2. Attach the provided 15′ (4.57m) cable to remote warning devices such as alarm systems or emergency equipment.

Operation

The PS-110 activates alarms through a dry contact output when power to the monitored circuit is interrupted for more than 3 to 8 consecutive minutes.

Maintenance

Regularly check the connections and ensure proper functioning of the Electronic Power Loss Monitor to guarantee reliable performance.

FAQ

  • Q: How do I reset the Electronic Power Loss Monitor?
  • A: To reset the monitor, unplug it from the outlet and plug it back in after a few seconds. Ensure the connections are secure.
  • Q: Can I use this device with international outlets?
  • A : No, this device is designed for use with standard 2-prong 120V AC outlets in the USA.

Package Contains

This Package Contains

  • 1 PS-110
  • 1 Product Guide

Features

  • Detect power loss by plugging into a standard outlet
  • Connects to most hardwire or wireless alarm systems
  • 3 to 8 minutes of power interruption closes the dry contact
  • Built-in delay of 3 to 8 minutes to avoid nuisance alarms
  • Do not put the PS-110 device into a cooler/freezer environment

Note

  • The Power-Out Alert™ contact is Normally Open (”N.O.”). Once power is lost for 3 to 8 minutes the curcuit is Normally Closed (”N.C.”).
  • Once power is restored the contact will take 3 to 8 minutes to restore back to N.O.
  • Test the device weekly to ensure proper operation.

Specifications

WINLAND-PS-110-Electronic- Power-Loss-Monitor-
FIG-4

This compact, easy-to-use device plugs into any standard 2-prong 120V AC outlet that requires monitoring. It has an attached 15’ (4.57m) cable that wires into remote warning devices such as alarm systems or other emergency equipment.
When power to the monitored circuit is interrupted for more than 3 to 8 consecutive minutes, the PS-110 activates alarms through a dry contact output. This time delay feature means that short power outages (<3 minutes duration) will not cause the PS-110 to activate. As long as electrical power is restored within 3 minutes to the circuit that the PS-110 is monitoring, the unit will automatically reset itself to a normal condition. Several PS-110s can be wired into a single warning system, making power failure monitoring for an entire complex easy.

INSTALLATION

A standard screwdriver is all you need to install the PS-110.

  • STEP 1 Disconnect AC Power
    To prevent possible injury, shut off electrical power to the circuit by turning off the circuit breaker or removing the circuit fuse.

  • STEP 2 : Mounting
    Plug the PS-110 into a working 2-prong 120V electrical outlet (this should not be controlled by a wall switch). Remove the screw from the centre of the outlet’s faceplate and attach the PS-110 with the eyelet and screw.

  • STEP 3 Connecting Power-Out Alert™
    Connect sensor wires to the remote device being used to receive the warning signal from the PS-110.

  • STEP 4: Restore Power to the Circuit
    Restore electrical power to the circuit by turning the circuit breaker back on or by replacing the fuse. Wait approximately 15 minutes for the sensor to become operational before continuing. (The time delay will vary depending on the ambient room temperature).

  • STEP 5 : Testing (Test device weekly to ensure proper operation)
    Manually activate the sensor for testing by interrupting the electrical power to the circuit by turning off the circuit breaker or by removing the fuse for 3 to 8 minutes. Within 3 to 8 minutes of the loss of power, the PS-110 will activate your remote device.

WARRANTY

  • Winland Electronics, Inc. (“Winland”) warrants to the original purchaser from Winland that each product of Winland’s that it manufactures shall be free from defects in material and factory workmanship for a period of one (1) year from the date of purchase when properly installed and operated under normal conditions according to Winland’s instruction.
  • Winland’s obligation under this limited warranty is limited to correcting the product without charge, at its factory any part or parts thereof which are returned, transportation charges prepaid, to the factory within one year of the date of purchase subject to
  • Winland’s examination shows to Winland’s satisfaction to be covered by this warranty.
  • Product returns will not be accepted unless a Return Material Authorization has been issued by Winland, which is subject to the purchaser’s identification of the purchase order number and product serial number.
  • UNAUTHORIZED RETURN SHIPMENT OR SHIPMENT CONTRARY TO WINLAND’S WRITTEN INSTRUCTIONS WILL VOID THIS LIMITED WARRANTY. Correction of such defects by repair, replacement, or refund of the amount paid for the product, at
  • Winland’s option, shall constitute fulfilment of all Winland’s obligations under this limited warranty. Repaired and replacement parts will be warranted for the remainder of the original product warranty. Repairs not covered by this limited warranty may be offered by Winland for a charge. This limited warranty shall not apply to any of Winland’s products that have been subject to misuse, negligence, or accident, or which have been repaired or altered outside of Winland’s factory.

CONTACT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WINLAND User Manuals

Related Manuals