DRAPER RPT1 Radiator Pressure Test Kit Instructions

June 6, 2024
DRAPER

INSTRUCTIONS FOR
Radiator Pressure Test Kit

Stock No.14455
Part No.RPT1

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT.

GENERAL INFORMATION

These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product. Read all these instructions before assembling, operating or maintaining this product.

This manual has been compiled by Draper Tools describing the purpose for which the product has been designed, and contains all the necessary information to ensure its correct and safe use. Following all the general safety instructions contained in this manual, it will ensure both product and operator safety, together with the longer life of the product itself. All photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product. Whilst every effort has been made to ensure the accuracy of the information contained in this manual, the Draper Tools policy of continuous improvement determines the right to make modifications without prior warning.

MANUAL PRESSURE TESTING INSTRUCTIONS

| |
---|---|---

  1. IMPORTANT: For detailed and concise instructions on the correct use of this kit, refer to the vehicle manufacturer’s or Haynes workshop manual.
  2. WARNING: Do not over-pressurize the system, as excessive pressure may cause the failure of the radiator, hoses, etc.
  3. Carefully undo and remove the radiator or expansion tank pressure cap (use a cloth or gloves and arm protection if the radiator cap is known to be hot).
  4. Select the correct adaptor and configuration of the stationary seat accessories and ensure it is securely fitted to the filler neck of the radiator or expansion tank (Fig.1).
  5. Attach the `push-fit’ connector (A) onto the male tailpiece of the adaptor fitted to the radiator.
  6. Depress the hand pump handle (B) and check the reading indicated on the pressure gauge (C). Ideal readings should range between 12-15PSI (always check relevant manufacturer’s or Haynes workshop manual), if the pressure level is below this range or the pressure drops during testing, a leak in the coolant system (radiator, hose, etc.) is the most likely source of the problem.
  7. Once the test is complete, release the air pressure by depressing the quick-release valve (D). Disconnect the `push-fit’ connector (A) and adaptor assembly and replace the radiator filler cap securely.

USING KIT WITH COMPRESSED AIRLINE:

– WARNING: Input air pressure must be set to below 25psi on a compressed airline BEFORE connecting to the cooling system. Failure to do so will cause damage to the system and danger to the user.
– Proceed as in steps 1-4 above.
– Ensure air tap (E) is in the closed position (see Fig.3).
– Connect compressed air line to air inlet (F).
– Connect to the adaptor using quick-coupling (G).
– Slowly open air tap (E) until air pressure gauge (H) shows the required test pressure (always check relevant manufacturer’s or Haynes workshop manual).
– Once the test is complete, completely close air tap (E), disconnect compressed air line (F) then carefully re-open air tap (E) to release stored pressure and remove it from the cooling system. Finally, replace the radiator cap securely.

ADAPTORS AND ACCESSORIES

CONTACTS

– DRAPER TOOLS LIMITED,
Hursley Road, Chandler’s Ford,
Eastleigh, Hampshire. SO53 1YF. The U.K.

Helpline: (023) 8049 4344
Sales Desk: (023) 8049 4333
Internet: www.draper.co.uk
E-mail: sales@drapertools.com
Sales Fax: (023) 8049 4209
General Enquiries: (023) 8026 6355

– Service/Warranty Repair Agent
For aftersales servicing or warranty repairs, please contact the Draper Tools Helpline for details of an agent in your local area.

YOUR DRAPER STOCKIST

PJDH130510

©Published by Draper Tools Limited.

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission in writing from Draper Tools Ltd.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals