SPECIFICATIONS
Power Requirement 12 VDC or 24VDC, 0.21W Max
Sensing Element Capacitive / IC
Sensing Range 5 to 95% RH at 77 °F (25 °C)
Accuracy ±3% from 25 to 75% RH at 77 °F (25 °C)
Response Time TC < 12 minutes
Operating Temperature -40 to +140 °F (-40 to +60 °C)
Weight 5.3oz (150.0g)
Dimensions 3.9” x 2.9“ x 1.7” (9.9cm x 7.4cm x 4.3cm)
Mounting Surface mount
Case Material ABS
Warranty 1Year Limited
Environmental Conditions:
HA-4 is meant for Indoor Use Only
Operating Temperature -40 to +140 °F (-40 to +60 °C)
Overvoltage category OVC I
Pollution degree 2
Ingress Protection IP21
Cleaning HA-4:
Clean the device with a soft dry cloth. Do not use liquid cleaners, solvents, or abrasive cleaners.
Clean the device with a soft dry cloth. Do not use liquid cleaners, solvents, or abrasive cleaners.
Tech Support 8: 00am – 5:00pm Central Time
800-635-4269
www.winland.com
GENERAL INFORMATION
The Winland HA-4 is a sensor used for monitoring remote locations for rising
or falling rates of humidity.
The HA-4 is designed and approved to be used with EnviroAlert® and EnviroAlert
Professional® families of monitoring devices including the EA200-12/ 24,
EA400-12/24, EA800-I P, and the EAPro-GTWY
THEORY OF OPERATION
The HA-4 senses the ambient room humidity electronically using a capacitive sensing element. Humidity should be expected to vary from room to room and from one area of a room to another. Ventilation and airflow will greatly affect relative humidity.
When programming the HA-4 sensor on the monitor’ing device, the initial reading you receive shou Id be considered a base reading. Allow at least 30 minutes of operation for the sensor to stabilize prior to setting the high and low limits. It is necessary for the temperature of the sensor to stablilize before the readings are considered accurate. The outputs of Wi nland’s electronic monitoring devices react within seconds of a limit being exceeded. A sudden burst of humid air from a door opening or a ventilation system starting, could cause a brief change in the humidity reading. To avoid false alarms, a time delay should be programmed in to the EA200-12/24, EA400-12/24, EA800-IP, and the EAPro-GTWY. It is strongly recommended to utilize a time delay unless your application requires instant notification.
Installation
The HA-4 sensor should be flush mounted directly to a flat surface like a wall. The sensor should be located in an area free from drafts, heat sources, and direct sunlight. It is recommended that the sensor is mounted at a height of 4-5′(1.2-l.Sm) from the floor.
Wire the HA-4 to your EA200-12/24, EA400-12/24, EA800-IP or EAPro-GTWY monitoring device using the following wiring scheme (See Figures 2 and 3). Extend t he length of the probe wiring up to 1,000′(304.Sm) using 18-22 AWG twisted pair.
FJGURE2
Red Wire = 12VDC Positive
Black Wire – 12VDC Negative
Blue Wire = Wire to negative H terminal on sensor input of desired
device:
EA200-12/24, EA400-12/24, EA800-IP, or EAPro-GTWY (see figure 2 & 3) Sensor
Input Positive {+) is not used.
FIGURE 3
Shows typical use with an EA200-12/24 and EA400-12/24device
To insure proper operation, test weekly.
ENVIROALERT® AND ENVIROALERT PROFESSIONAL®
- **EA200
**
- **EA400
**
- **EA800-ip
**
- **EAPro-GTWY
**
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE Directive}. According to the WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered under the WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return Process: Contact Winland via our web site at www.winland.com.
Radio Frequency Interference Requirements: This device complies with Part 15
of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
CE Marking and European Union Compliance: Products intended for sale within the European Union are marked with the CE Mark, which indicates compliance to applicable Directives and European Norms (EN}. Amendments to these Directives or ENs are included: Electromagnetic Compatibility Directive 2004/108/EC; Low Voltage Directive 2006/95/EC; RoHS Directive 2002/95/EC; WEEE Directive 2002/96/EC.
Statement of Compliance : Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable Directives 2004/108/EC,2006/95/EC,2002/95/EC,2002/96/EC.
Symbols on the Product or Manual Labeling
WARRANTY AND SERVICE INFORMATION
Winland Electronics, Inc. (“Winland”) warrants to the original purchaser from Winland that each product of Winland’s that it manufactures shall be free from defects in material and factory workmanship for a period of one (1) year from the date of purchase, when properly installed and operated under normal conditions according to Winland’ s instruction.
Winland’ s obligation under this limited warranty is limited to correcting the product without charge, at its factory any part or parts thereof which are returned, transportation charges prepaid, to the factory within one year of the date of purchase subject to Winland’ s examination showing to Winland’s satisfaction to be covered by this warranty.
Product returns will not be accepted unless a Return Material Authorization
has been issued by Winland, which is subject to purchaser’s identification of
the purchase order number and product serial number. UNAUTHORIZED RETURN
SHIPMENT OR SHIPMENT CONTRAR TO WINLAND’S WRITTEN INSTRUCTIONS WILL VOID THIS
LIMITED WARRANTY.
Correction of such defects by repair, replacement or refund of the amount paid
for the product, at Winland’s option, shall constitute fulfillment of all
Winland’s obligations under this limited warranty. Repaired and replacement
parts will be warranted for the remainder of the original product warranty.
Repairs not covered by this limited warranty may be offered by Winland for a
charge.
This limited warranty shall not apply to any of Winland’s products which have been subject to misuse, negligence, accident or which have been repaired or altered outside of Winland’s factory.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT, DESIGN, AND TITLE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS MADE TO THE END USER/PURCHASER BY ANY OTHER PARTY ARE EXCLUDED. No person, agent or dealer is authorized to give warranties on behalf of Winland nor to assume for Winland any other liability in connection with any Winland product.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use, malfunction or unavailability of its products or any other cause except as stated in this limited warranty.
WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY OR
OTHER CONTRACT, NEGLIGENCE, OTHER TORT, STRICT LIABILITY OR OTHERWISE. Under
no circumstances shall Winland’ s liability under this limited warranty exceed
the purchase price paid by the end user/purchaser for the product.
The parties agree that the limitation of remedies in this document is an
agreed upon allocation of risk and does not cause the remedy to fail of its
essential purpose.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>