Bellababy BLA-8021 Pocket Electric Breast Pump User Manual
- June 1, 2024
- Bellababy
Table of Contents
- Bellababy BLA-8021 Pocket Electric Breast Pump
- Read Before Use
- How to Use and Maintain
- Troubleshooting
- Components Diagram
- Assembly Steps
- Touch Panel Controls
- PRODUCT DESCRIPTION
- Matters Need Attention
- Symbols & Meanings
- Product Parameters
- Safety Classification
- FREQUENTLY ASKED QUESTIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Bellababy BLA-8021 Pocket Electric Breast Pump
Read Before Use
-
Any questions/problems during assembly and use please contact the service team for assistance.
Email: service-US@bellababy-med.com -
There are metal springs inside the storage bag adapters, do not microwave them otherwise they will melt.
-
Make sure every part is dry enough before use, especially the cylinder, cylinder cover, and tubing, otherwise the water/moisture will get into the machine through the tubing and then damage the circuit, motor, and battery. Do not wash or steam-sterilize the tubing because it does not touch the body or milk.
-
This pump is totally in a closed system, air and milk are completely separated. So if milk gets into the tubing, there must be something wrong with the assembly. Please stop using and contact with service team to troubleshoot. If need to connect with other brands’ flanges, please make sure they are in a closed system (there is a membrane/ cylinder to separate air and milk). If you are not sure please send an email with photos for our confirmation before use.
-
Before the first use, please fully recharge the machine. To prolong the battery life, do not keep using the item when the battery is very low, and do not use it when it is recharging.
-
Accessories are on sale, please click the store name on the Amazon products page, then click Product to find them. If still confused please contact the seller.
-
When pressing the button to turn on the machine, make sure the finger is dry and clean without sweat, oil, water, or callus, so the machine can detect the operation better.
-
The machine will shut off automatically after 30 minutes of use, this is a protection setting but not a malfunction, just turn it on if you need to continue using it.
How to Use and Maintain
- Before the first use, please wash every part except the tubing and machine, then sterilize them with a steam sterilizer(Boiling water instead if don’t have a steam sterilizer). If yours is a UV sterilizer or a microwave oven, please do not put it in the storage bag adapters. Make sure every part is dry enough, then follow the instructions to assemble the parts properly.
- Before pumping, it’s better to massage and warm the breasts with a hot towel for a while, that will help milk letdown and less pain, especially for new moms.
- Sit down and relax, attach the flange to your breast closely without air leakage. Incline the upper body forward a little. If no breast milk comes out in 5 minutes, please try another time to pump or consult a doctor.
- For moms pumping many times a day, please wash and air dry the parts after every use. Then sterilize them after the last use. When assembling or disassembling, please follow the instructions to make sure every part is assembled correctly, no air leakage.
- The USB cable can connect a laptop, power bank, and car charger to recharge, do not use any unoriginal charger to recharge, if your charger missing, please purchase in our Amazon store or contact with seller for assistance.
- Long press the on/off button to turn on. Pumping will automatically start with massage mode, clicking the button will switch to expression mode, long press the button will shut off. Press the – or + button to adjust the suction that is most comfortable to you.
- An electric breast pump is intended for the suction of lactating women and breast milk collection.
- When the machine is working and you want to stop using it, please long press the on/off button to shut it off.
Troubleshooting
No suction
- Insert the tubing into the wrong hole of the machine, there are a suction hole and a recharging hole, please check.
- The tubing connection is wrong, the main tubing should be inserted into the machine, and the branched tubings should be inserted into the flanges.
- Assemble the cylinder wrong and there is an air leak, make sure the cylinder and cylinder cover is assembled correctly and tightly
- The shield doesn’t cover the breast closely enough, please attache the breast to the shield tightly without air leakage.
- The motor is broken, please contact the service team for assistance.
Weak suction
- The accessories get aging. It the time to replace. Usually, the duckbill/cylinder valves should be replaced after 2~4 weeks according to your use frequency.
- The battery is too low, please recharge the machine.
- For air leakage, please check every part connection.
- The Duckbill valve is loose, please replace it.
- Motor malfunction, please contact the service team for assistance.
Milk get into the tubing
- A mistake of assembly, this pump is in a closed system and milk can not get into the tubing, please check or contact with service team.
- The cylinder is broken, please replace the cylinder.
- An open system flange doesn’t connect with any open system flange, closed system only.
Milk can not drip into a bottle/storage bag and stay on/under the cushion pad
- The duckbill valve closes too tight and milk can not flow through, please replace the valve or make the valve a little open to let the milk drop down.
The machine can not turn on
- Low battery, please recharge and try again.
- Short press, please long press the power button for at least 3 seconds to turn it on.
- The finger is with water/oil or callus, clear and dry your finger.
- Not under operating conditions, please use the product under room temperature and ordinary pressure.
- Machine malfunction, please contact with service team or seller.
Components Diagram
No Name Material Heat-resistance Quantity
1| Dust cover| pp| -20~120°(| 2
2| Massage cushion| Liquid silicone| -20~180°(| 2
3| Tee Joint| pp| -20~120°(| 2
4| Cover of suction cylinder| pp| -20~120°(| 2
5| Suction cylinder| Liquid silicone| -20~180°(| 2
6| Valve| Liquid silicone| -20~180°(| 4
7| Bottle| pp| -20~120°C| 2
8| Main Machine| ABS| -10~80°(| 1
9| Base of bottle| pp| -20~120°(| 2
10| Tube joint| pp| -20~120°(| 1
11| Screw cap of bottle| pp| -20~120°(| 2
12| Nipple| Liquid silicone| -20~180°C| 2
13| Bottle Cover| pp| -20~120°(| 2
Assembly Steps
- Insert the massage cushion into the shield tightly.
- Set the cylinder into the tee joint tightly, then press the cylinder cover closely, no air leakage.
- Set the valve on the round bulge in the tee joint tightly(Note: Please do it carefully as the valve is flimsy, if damaged, replace it) If need a single pump. just insert the brenenod tude to the tubing joint as this image shows.
- Screw bottles in the tee joint, and connect them with the machine by the tubing tightly.
Attention: Make sure the tubing is inserted into the suction hole on the right side but not the recharging hole on the left side.
Touch Panel Controls
- Massage Mode – Massages and stimulates breasts. Quicker and Lighter suction. Adjustable up to 6 levels. Use this mode initially to enable milk letdown, especially for new moms.
- Expression Mode – Longer and stronger suction. Adjustable up to 9 levels. Experienced moms could use this mode to pump more efficiently.
PRODUCT DESCRIPTION
- Compact and portable
- Super silent
- Window Icd screen that shows massage/expression mode, battery life, suction level, and time elapsed
- Touch panel controls
- Battery life up to 240 minutes per full charge
- Can be plugged into a 2A power bank
- Strong suction up to 300mmHg
- Massage mode has 6 levels/expression mode has 9 levels
- BPA free materials
- Includes silicone cushion pad and bottle stands
- Closed system with backflow preventer
Matters Need Attention
- Please feel free to contact the MANUFACTURER or MANUFACTURER’S representative on the following issues:
- Assistance needed in setting up, using, or maintaining the EQUIPMENT or SYSTEM
- or to report unexpected operations or events.
- This equipment complies with IEC 60601-1-2:2014 for electromagnetic compatibility for medical electrical equipment and/or systems. However, because of the proliferation of radio frequency transmitting equipment and other sources of electrical noise in healthcare and other environments, it is possible that high levels of such interference due to close proximity or strength of a source might disrupt the performance of this device.
- Portable and mobile RF communications equipment can affect medical electrical equipment.
- Keep the breast pump out of reach of children. Avoid inhalation or swallowing of small parts. And the tube may cause strangulation.
- Use of accessories other than those specified or provided by the manufacturer of this equipment may result in failure to work or even safety incidents.
- Do not modify the device without the authorization of the manufacturer. This could cause improper functioning.
- Do not use the Breast pump in the vicinity of shortwave or microwave therapy equipment, since this may affect the normal safe operation.
- This product cannot be used in harsh environments such as cotton wool, dust, or strong light (including sunlight).
- Do not replace the battery by yourself, otherwise, incorrect replacement of the battery will result in battery damage, even fire, or explosion. If necessary, please feel free to contact our customer service staff and it will be repaired or replaced by our qualified personnel.
- Do not perform any repair or maintenance while using this product for breast milk collection.
- If the product is in no use for a long time, it is recommended to be charged every 1 dad to have good performance.
- Follow local ordinances and recycling instructions regarding disposal or recycling of the device and device components. including batteries.
- External equipment intended for connection to USB for charging shall comply with relevant IEC standards (e.g., IEC 60950 for IT equipment and IEC 60601 series for medical electrical equipment). If, in doubt, contact a qualified technician or your local representative.
- The circuit diagrams, the list of components, the illustration of diagrams, and the detailed rules of calibration are provided exclusively to professional personnel authorized by our company.
Symbols & Meanings
- Product serial number (The first 4 digits are the year and month, and the last 6 digits are the serial number.)
- Manufacturer name and address
- Please refer to the instruction manual
- Waste electrical materials should be sent to a dedicated collection point for recycling
- The level of dust and water repellency
- Alliped parts: Type BF
- DC symbol
Product Parameters
Product Applicable Environment
Operating temperature | 0°C~+40°C | Stored temperature | -10°C~+60°C |
---|---|---|---|
Working humidity | 45%~80% | Storage humidity | 45%~90°/o |
Net weight | 720g | Atmospheric pressure | 80KPa-106KPa |
Power | 5w | Voltage | DC5V 1A |
Suction | 80-300mmH | Battery | 3.7V 2400mAh Li-ion |
Working time (Full Charged) | About 240 Minutes |
Service life of the device: 1 years
Safety Classification
- Type of protection against electric shock: Internally powered equipment.
- Degree of protection against electric shock: Type BF applied part.
- Degree of protection against ingress of water: IP22
- Safety degree of using in flammable anesthetic gas blending with air, oxygen or nitrous oxide: Non-AP/APG
- Continuous or Non-continuous operation: Continuous
- Classification of sterilization methods: No need for sterilization
Bellababy
NingBo Huiyoo Baby Products Co., LTD.
- Add: 523# Cizhang Road,Zhangqi Industrial Area, Cixi City,Zhejiang Province,P.R. China.
- Tel.: +86 574 63679665
- Fax: +86 574 63677885
- E-mail: service-US@bellababy-med.com
- service-EU@bellababy-med.com
- Date of issue: 2019/03/12
- Version: V1.0
FREQUENTLY ASKED QUESTIONS
What is the operation mode of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The Bellababy BLA-8021 Pocket Electric Breast Pump operates electrically.
What are the product dimensions of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The product dimensions of the Bellababy BLA-8021 Pocket Electric Breast Pump are 10 x 2 x 4 inches.
What are the additional product features of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The Bellababy BLA-8021 Pocket Electric Breast Pump is portable and rechargeable.
What is the power source of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The power source of the Bellababy BLA-8021 Pocket Electric Breast Pump is battery-powered.
Is the Bellababy BLA-8021 Pocket Electric Breast Pump dishwasher safe?
Yes, the Bellababy BLA-8021 Pocket Electric Breast Pump is dishwasher safe.
What is the item weight of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The item weight of the Bellababy BLA-8021 Pocket Electric Breast Pump is 1.76 pounds.
What is the price of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The price of the Bellababy BLA-8021 Pocket Electric Breast Pump is $29.99.
What is the item model number of the Bellababy BLA-8021 Pocket Electric Breast Pump?
The item model number of the Bellababy BLA-8021 Pocket Electric Breast Pump is BLA-8021.
What is the warranty period for the Bellababy BLA-8021 Pocket Electric Breast Pump?
The Bellababy BLA-8021 Pocket Electric Breast Pump comes with a 1-year warranty.
How do I recharge the Bellababy BLA-8021 Pocket Electric Breast Pump?
To recharge the Bellababy BLA-8021 Pocket Electric Breast Pump, connect it to a power source using the provided charging cable
Why is my Bellababy BLA-8021 Pocket Electric Breast Pump not turning on?
Ensure that the pump is properly charged or has fresh batteries inserted. Check if the power button is pressed correctly. If the pump still doesn't turn on, there may be an issue with the power source or internal components. Contact Bellababy customer support for assistance.
What should I do if my Bellababy BLA-8021 Pocket Electric Breast Pump is not suctioning effectively?
Make sure all parts are assembled correctly and securely. Check for any tears or damage in the silicone parts. Adjust the suction level if possible. If the issue persists, there may be a problem with the pump's motor or suction mechanism. Contact Bellababy customer support for further assistance.
My Bellababy BLA-8021 Pocket Electric Breast Pump is making unusual noises during operation. What could be the problem?
Unplug the pump and inspect it for any loose parts or foreign objects. Check if all parts are properly aligned and connected. If the noise persists, there may be an issue with the motor or internal components.
Why is my Bellababy BLA-8021 Pocket Electric Breast Pump not charging properly?
Ensure that the charging cable is securely connected to both the pump and the power source. Check for any damage to the charging cable or port. If the pump still doesn't charge, there may be an issue with the battery or charging circuit.
What should I do if the suction strength of my Bellababy BLA-8021 Pocket Electric Breast Pump is too weak?
Check if all parts are clean and properly assembled. Try adjusting the suction level if possible. If the suction strength remains weak, there may be an issue with the pump's motor or suction mechanism.
DOWNLOAD THE PDF LINK:Bellababy BLA-8021 Pocket Electric Breast Pump User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>