Braun IRT3030 ThermoScan Infrared Ear Thermometer Instruction Manual

June 1, 2024
Braun

Braun IRT3030 ThermoScan Infrared Ear Thermometer

This product is manufactured by Kaz Europe Sàrl under a license to the ‘Braun’ trademark. ‘Braun’ is a registered trademark of Braun GmbH, Kronberg , Germany.
ThermoScan is a registered trademark of Kaz Europe Sàrl
Kaz Europe Sàrl
Place Chauderon 18
CH-1003 Lausanne, Switzerland
© 2016, Kaz Europe Sàrl
www.hot-europe.com
Designed in the USA Made in China
www.kaz.com/patents/braun
IRT3030WE
PN: 31IM303W190R1
25APR16

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(2\)

Product Description

  1. Protective cap
  2. Disposable lens filter
  3. Probe
  4. «start» button
  5. Probe tip (lens)
  6. Lens filter detector
  7. Display
  8. Battery door safety lock
  9. Battery door (1 X 3V type 2032 battery)

The Braun ThermoScan® thermometer is indicated for intermittent measurement and monitoring of human body temperature for people of all ages.

Important safety information

  • Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc. in spite of absence of fever.

  • The operating ambient temperature range for this thermometer is 10 – 40 °C (50 – 104 °F).

  • Do not expose the thermometer to temperature extremes (below –25 °C / –13 °F or over 55 °C / 131 °F) or excessive humidity (> 95 % RH).

  • This thermometer must only be used with genuine Braun ThermoScan® disposable lens filters. Other ens filters can lead to inaccuracy. To avoid inaccurate measurements always use this
    thermometer with a new, clean, disposable lens filter.

  • If the thermometer is accidentally used without a disposable lens filter, clean the lens after use (see «Care and cleaning»).

  • Keep disposable lens filters out of reach of children. This thermometer is intended for household use only.

  • Use of this thermometer is not intended as a substitute for consultation with your physician.

  • This thermometer must stay in stable ambient (room) temperature for 30 minutes before operating.

Audio fever indicator

Thermometer will signal by beeps normal, elevated or high temperature.

Temperature Reading Number of Beeps
Normal (≤37.4 °C or 99.3 °F) One beep: )
Elevated (≥ 37.5 °C or 99.5 °F) Two beeps, repeated: )) )) ))
High (≥ 38.6 °C or 101.5 °F) Four beeps, repeated: )))) )))) ))))

Body temperature
Normal body temperature is a range. It varies by site of measurement and it tends to decrease with age. It also varies from person to person and fluctuates throughout the day. Therefore, it is important to determine normal temperature ranges.

How to use your Braun ThermoScan®

Before taking the temperature, make sure the ear is free from obstructions or excess earwax. Do not attempt to take the reading without a disposable lens filter on – the measuring sensor must be kept protected and clean from earwax to give accurate readings. Change the disposable lens filter with each use to ensure hygiene, to keep child safe from cross-contamination and to ensure earwax residues on the disposable lens filter do not impact accuracy of the reading.

  1. To turn the thermometer on, push the «start» button 1  (4). During an internal self-check, the display shows all segments. The reading showed on the screen is the last temperature taken. Flashing symbol of lens filter will appear if no lens filter is attached. Temperature can be taken only if lens filter is mounted on the probe. The thermometer is ready to use after two beeps are sounded and the non- flashing ear icon appears.
  2. Fit the probe (3) snugly into the ear canal, then push the «start» button (4). One beep signals normal temperature. Audio fever indicator will trigger 2 consecutive beeps when the reading is equal or higher to 37.5 °C (99.5 °F) and 4 beeps if the reading is equal or higher to 38.6 °C (101.5 °F). The result is shown on the display (7).
  3. Gently pull off the disposable lens filter (2). Do not use force in removing the disposable lens filter.
  4. Put on a new, clean, disposable lens filter by snapping into position.
  5. Place the protective cap on (1).

The Braun ThermoScan ear thermometer turns off automatically after 60 seconds of inactivity. The thermometer can be turned off by pressing and holding the start button for more than 5 seconds.

Disposable lens filters

Use a clean disposable hygienic lens filter with each measurement:

  1. To ensure hygienic use
  2. To protect your child from cross-contamination
  3. To ensure earwax residues do not impact accuracy of the reading.

Earwax and dirt on the tip of the disposable lens filter, even in microscopic layer, can create an obstacle between the sensor and the infrared heat emitted by the ear and impact the accuracy of the measurement.

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(7\)

  • Replace the disposable lens filter with every use to maintain hygiene and accuracy.
  • A measurement taken in the right ear may differ from the measurement taken in the left ear. Therefore, always take the temperature in the same ear.
  • The ear must be free from obstructions or excess earwax build-up to take an accurate reading.
  • External factors may influence ear temperatures, including when an individual has:
    • been lying on one ear or the other
    • had their ears covered
    • been exposed to very hot or very cold temperatures, or
    • been recently swimming or bathing.

In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature.

  • If ear drops or other ear medications have been placed in the ear canal of one ear, take the temperature in the untreated ear.

Care and cleaning

  • The probe tip (5) is the most delicate part of the thermometer.
  • It has to be clean and intact to ensure accurate readings.
  • If the thermometer is accidentally used without a disposable lens filter, clean the probe tip as follows: Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. Do not use cleaners other than alcohol on the probe tip. Use of other cleaners could damange the tip.Braun-IRT3030-ThermoScan-Infrared-Ear-Thermometer-\(8\)
  • Once the alcohol has dried completely, a new disposable lens filter can be put on and a temperature measurement taken. If the probe tip is damaged, please contact your authorized local service center.
  • Use a soft, dry cloth to clean the thermometer display and product exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid.
  • Store the thermometer and disposable lens filters in a dry location free from dust and contamination and away from direct sunlight.
  • Additional disposable lens filters (LF 40) are available at most stores selling Braun ThermoScan.

 Trouble-shooting

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(9\)

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(10\) Braun-IRT3030
-ThermoScan-Infrared-Ear-Thermometer-\(11\)

Changing the temperature scale
Make sure the thermometer is turned off. Press and hold down the <> button. Keep holding down the <> button and after about 3 seconds the display will start to cycle between temperature scales (°C or °F). Release the start button when the desired scale is shown. This will reset the thermometer to the new temperature scale. The thermometer is supplied with one 3V Lithium cell battery (type 2032). Insert new battery when the low battery symbol appears on the display. The battery door design is intended to prevent a small child from easily opening the battery door to address a possible choke hazard. Open the battery compartment by inserting a narrow pointed object such as a ball point pen or paperclip into the small hole above the battery door (8). While pressing into the hole slowly slide back the battery door with the other hand. To close battery door align the tabs along the side of the battery into the battery compartment and slowly slide back into position until the door clicks into its locked position.

Calibration
This product has been calibrated at the time of manufacture. If used according to the use instructions, periodic calibration is not required. If at any time, you question the measuring accuracy, please contact our service representative (see last page for contact information) or visit www.hot- europe.com/support. Manufacturing date is given by the LOT number located in the battery compartment. The first three (3) digits after LOT represent the Julian date that the product was manufactured and the next two (2) digits represent the last two numbers of the calendar year the product was manufactured. The last identifiers are the letters that represent the manufacturer.
An example: LOT 11614fam, this product has been manufactured on the 116th day of the year 2014.

Guarantee
EMC tables and Consumer Card are available on our website at www.hot- europe.com/support For support requests, please visit www.hot-europe.com/support or find service contact information on the last page of this manual.
UK only: This guarantee in no way affects your rights under statutory law.

Product specifications

  • Model: IRT 3030

  • Displayed temperature range: 34 °C – 42.2 °C (93.2 °F – 108 °F)

  • Operating ambient temperature range: 10 °C – 40 °C (50 °F – 104 °F)

  • Storage temperature: -25 °C – 55 °C

  • Display resolution: 0.1 °C or °F

  • Accuracy for displayed temperature range:
    ± 0.2 °C (35.5 – 42 °C)
    (95.9 – 107.6 °F)
    ± 0.3 °C (outside this temperature range)

  • Clinical bias: -0.11 °C (-0.198 °F)

  • Limits of agreement: ± 0.25 °C (0.45 °F)

  • Clinical repeatability: ± 0.10 °C (0.18 °F)

  • Measuring Site: Ear

  • Reference Site: Oral (estimated oral temperature is Operating and storage displayed)

  • relative humidity: ≤ 95% non-condensing

  • Battery life: 2 years /1000 measurements

  • Service life: 5 years

  • Warranty: 2 years

If device is not used or stored within specified temperature and humidity ranges the technical accuracy cannot be ensured.

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(12\)

Subject to change without notice.
IP22: Protected against solid foreign objects of 12.5 mm diameter and greater. Protected against vertically falling water drops when the device is tilted up to 15 degrees.
EN 12470‑5:2003 Clinical thermometers—Part 5: Performance of i nfra‑red ear thermometers (with maximum device)
ISO 80601‑2‑56:2009 Medical electrical equipment— Part 2‑56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
This product conforms to the provisions of the EC directives 93/42/EEC (Medical Device Directive) and 2011/65/EU (RoHS). The Braun ThermoScan needs special precautions regarding EMC. For detailed description of EMC requirements please refer to www.hot-europe.com/support. Portable and mobile RF communications equipment can affect the Braun ThermoScan.
This product contains batteries and recyclable electronic waste. To protect the environment, do not dispose of it in the household waste, but take it to appropriate local collection points.

Support contact numbers

Austria
% +43 (0)1 360 277 1225

Iceland
% +354 555 3100

Central Region – Riyadh
% +966 (0) 12886808

Bahrain
% +973 17582250

Israel
% +1 800250221

Al-Khobar
% +966 (0) 38940555

Belgium/Luxemburg
% +32 (0) 2 620 01 01

Italy
% +39 02 3859 1183

South Region – Abha
% +966 (0) 72376062

Bosnia
% +387 (33) 636 285

Jordan
% +962 6 582

Slovakia
% +421 2 5011 2115

Bulgaria
% +359 (2) 40 24 600
0112-3-4-5

Kuwait
% +965 24833274

Slovenia
% +386 (01) 888 86 74

Croatia
% +385 (01) 3444 856

Lebanon
% +961 (01) 512002

South Africa
% +27 (0) 11 089 1200

Cyprus
% +357 22575016

Netherlands
% +31 (0) 78 201 8001

Spain
% + 34 913 754 176

Cyprus Northern region
% +0392 22 72 367

Norway
% +47 23 50 01 20

Sweden
% +46 (0)8 5199 3097

Czech Republic
% +420 (0) 2 25 43 97 69

Poland
% +48 22 512 39 02

Switzerland
% +41 (0) 22 567 5200

Denmark
% +45 35 15 80 40

Portugal
% +351 21 060 8045

Tunisia
% +216 71716880

Finland
% +358 (0)9 81 71 00 14

Qatar
% +974 4 4075048
% +974 4 4075000

Turkey
% +90 216 337 22 55

France
% +33 (0) 1 85 14 80 95

Romania
% +40 214 255 566

UAE
% +971 4 353 4506

Germany
% +49 (0) 21 173 749 003

Saudi-Arabia
% +966 3 8692244

United Kingdom/ Ireland
% +44 (0) 115 965 7449

Greece
% +30 211 180 94 56

Hungary
% +36 (06) 1 429 2216

Western Region – Jeddah
% +966 (0) 22565555

Helen of Troy
CREATIVE DEPARTMENT ARTWORK SPECIFICATIONS

  • Brand: Braun
  • Category: Thermometer
  • Model: IRT3030WE
  • Artwork Part #: 31IM303W190R1
  • Die Line Part #: N/A
  • Agile Desc: OM, IRT3030WE
  • Subject: Owner’s Manual
  • Region: EMEA
  • Flat Size: MM: W156 x H120
  • Folded Size: MM: W78 x H120
  • Scale: 1/1
  • Material: 50# matte text (inside pages)
  • Minimum 80# gloss or matte text (cover)
  • Page Count: 116
  • Revision: 19
  • Date: 25APR16
  • Release Date: 19JAN16
  • Re-release Date: 26FEB16
  • Re-release Date: 28APR16

Colors:

Braun-IRT3030-ThermoScan-Infrared-Ear-
Thermometer-\(14\)

Special Instructions:
Quality Requirement of Artwork and Quality Clarification Process of Artwork Printing: Meet Eng-QS-06&02
Kaz USA, Inc., a Helen of Troy Company Creative Services
Marlborough, MA 01752, USA +1 508 490 7000

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals