RAFI RAMO 30 E Round Collar Owner’s Manual
- June 1, 2024
- RAFI
Table of Contents
Technical data sheet
1.11.031.011/0000
RAMO 30 E, M12, round collar, 2 NC, Gold, M12 5-pin A-coded, reset
by rotating, Mushroom head red, arrows red
Fields of application
- Measurement-control-regulation
- Electrical engineering
- Mechanical and system engineering
- Automotive
- Signalling systems
- Vehicle construction
- Chemical industry
- Industrial robots
Special features
- One-piece enclosed housing for protection classes of at least IP 65
- Plug & Play with M12 connection
- RAMO EDGE: mounting bracket for decentralized installation
- Design matching the RAFIX command devices
Description
Emergency stop with M12 connection: RAMO E switches are designed with two NC
contacts for a switching voltage of 35 V. They comply with all applicable ISO
and IEC standards and are characterized by their simple, time-saving
installation. Like the entire RAMO series, the emergency stop switches feature
installation-friendly M12 plug-in connections that reduce wiring effort to a
minimum.
Additional information according to UL certificate:
For Class 2 Power Source or Limited Voltage / Limited Current only
Installation only by trained specialist personnel.
Type 4x Indoor only with cable “Cat. No. 7000-08061-0210100 PUR 4×0.25mm² with
M8 connector, rated max. 30VAC/DC 4A, manufactured by Murrelektronik GmbH” and
“Cat. No. 7000-12221-0340100 PUR 4×0.34mm² with M12 connector, rated max.
30VAC/ DC 4A, manufactured by Murrelektronik GmbH”
For Use on a Flat Surface of a Type 1 or 4x indoor only Enclosure.
Technical data
General
Potential free | yes |
---|---|
Color of mushroom | red |
Legending color | red |
Collar color | yellow |
Collar shape | round |
Operating temperature, min. | -40 °C |
Operating temperature, max. | 85 °C |
Storage temperature, min. | -40 °C |
Storage temperature, max. | 90 °C |
illuminated | No |
Packaging | Box |
Direct links
RAFI eCatalog
Packaging unit | 2 pcs. |
---|---|
net weight | 32 g |
Operating life | 50,000 cycles |
B10 | 65,000 cycles |
B10d | 130,000 cycles |
Degree of protection, front side, according to DIN EN 60529 | IP65 |
Degree of protection, rear side, | IP65 |
according to DIN EN 60529 | IP67 |
UL Enclosure Type Rating front side | type 4X indoor |
Environment resistance | IEC 60068-2-14 |
IEC 60068-2-30
IEC 60068-2-33
IEC 60068-2-78
Shock resistance according to standard IEC 60068-2-27| 50 g at 11 ms amplitude
semi-sinusoidal
Salt-spray resistance according to standard| IEC 60068-2-11
shock resistance| 06 side
07 frontal
oscillation restistance according to standard IEC 60068-2-6| 5 g at 10…500 Hz
MOQ order| 2 pcs.
Pollution degree acc. to DIN EN 61010-1| Pollution degree 2
RoHS compliant| Yes
REACH compliant| Yes
Mounting diameters
Outside dimension, length | 34.5 mm |
---|---|
Outside dimension, width | 34.5 mm |
Outside dimension, height | 69.7 mm |
Mounting hole | 30.3 mm |
Mounting depth | 36.3 mm |
Installation height | 33.4 mm |
Grid, min. | 35 mm |
Mechanical data
Actuation function | latching |
---|---|
Resistance to force on the side | 300 N |
Contact function | 2 NC |
Contact material | Gold |
Resetting | by rotating |
Fixing | Threaded ring |
Threaded ring torque, max. | 1.2 Nm |
Terminal on the rear | M12 5-pin A-coded |
PIN 1 | Normally closed contact 1 |
PIN 2 | Normally closed contact 2 |
PIN 4 | Normally closed contact 1 |
PIN 5 | Normally closed contact 2 |
Electrical data
Rated insulation voltage | 250 V |
---|---|
Rated surge voltage | 2,500 V |
Rated operating voltage | 35 V (AC-15) |
35 V (DC-13)
Rated voltage, min.| 1 V
Rated voltage, max.| 35 V
Voltage type| DC
Rated operating current| 0.1 A
Rated operating voltage| 1-35 V
Rated current, min.| 0.001 A
Rated current, max.| 0.1 A
Power loss| 0.001 W
Overvoltage category| 2
Kind of short circuit protective device| fuse 250 V / 0,1 A / 1,5 kA gG quick
Conditional short circuit current| 1,000 A
Drawings
Dimensioned drawing
Mounting hole drawing
Schematic diagram
Mounting
LUMOTAST 16, LUMOTAST 22, LUMOTAST 25, RAMO 22, RAMO 30
Operating Instructions EMERGENCY STOP Control Units (Translation of the
source text)
1. Safety instructions
- Please read the operating instructions carefully prior to use.
- EMERGENCY STOP control units are designed to protect persons. Inappropriate installation, improper use or inadmissible manipulation may result in severe injuries!
- EMERGENCY STOP control units must never be bypassed, removed or disabled in any other way!
- Disconnect the power supply to the machinery and device prior to installation!
- Operate the EMERGENCY STOP control unit to test and verify proper installation and function prior to initial start-up of the machine or line.
- An EMERGENCY STOP control unit with an obvious defect must be replaced immediately.
- The emergency stop function is not to be used for safety measures or safety functions.
- The emergency stop function must not compromise the effectiveness of safety devices or devices with other safety functions.
2. General description and intended use
EMERGENCY STOP control units are electromechanical switching devices
designed to protect persons. They are used for instant disconnection to
achieve a safe status of machines, vehicles or other equipment in order to
avoid or reduce risks or damage to man and machine
The following standards and regulations apply to their start-up, use and
technical inspections, without limitation:
- Machinery Directive 2006/42/EC
- Safety standards
- Accident prevention regulations / rules for safety
Manufacturers and users of machines provided with EMERGENCY STOP control units
are responsible for ensuring that the operating instructions are observed and
the applicable safety standards and rules complied with.
For the installation and operation of EMERGENCY STOP control devices in line
with the intended use, the following requirements must be observed and a risk
assessment must be performed:
- ENISO 13849-1:2015
- ENISO 13849-2:2012
- ENISO 13850:2015
- EN 60204-1/A1:2009
3. Product description
Design: An EMERGENCY STOP button is an assembly of actuator combined with
one or more contact blocks. EMERGENCY STOP buttons are available either as a
panel mounting version or installed in a separate housing. They are operated
by pressing. Unlatching is done by one of two methods:
- Turning in either direction
- Pulling against the direction of operation
“Aktiv/Inaktiv”-Variants: “Aktiv”: illuminated red, Emergency Stop function given; “Inaktiv”: not illuminated, transparent, no Emergency Stop function.
Product | Mounting Ø mm | Actuator | Contact block |
---|---|---|---|
LUMOTAST 16 | Ø 16,2 | 1.15.213.001/0000 |
1.15.213.002/0000
1.15.213.003/0000
1.15.213.004/0000
1.15.213.011/0000
1.15.213.012/0000
1.15.213.013/0000
1.15.213.014/0000
1.15.213.051/0000
1.15.213.052/0000
1.15.213.053/0000
1.15.213.054/0000
1.15.213.061/0000
1.15.213.062/0000
1.15.213.063/0000
1.15.213.064/0000
1.15.213.101/0000
1.15.213.102/0000
1.15.213.103/0000
1.15.213.104/0000
1.15.213.301/0000
1.15.213.302/0000
1.15.213.303/0000
1.1§.213.304/0000
1.15.213.311/0000
1.15.213.312/0000
1.15.213.313/0000
1.15.213.314/0000
1.15.213.401/0000
1.15.213.402/0000
1.15.213.403/0000
1.15.213.404/0000
1.15.213.411/0000
1.15.213.412/0000
1.15.213.413/0000
1.15.213.414/0000| integriert / incl.
LUMOTAST 22| Ø 22,3| 1.15.105.002/0000
1.15.105.012/0000
1.15.105.022/0000
1.15. 105.032/0000
1.15. 105. 112/0000| integriert / incl.
LUMOTAST 25| Ø 16,2| 1.15. 154.006/0301
1.15. 154.016/0301| integriert / incl.
RAMO 22| Ø 22,3| 1.10.031.001/0000
1.10.031.004/0330
1.10.031.022/0330
1.10.031.101/0000| integriert / incl.
RAMO 30| Ø 30,3| 1.11.031.001/0000
1.11.031.004/0330
1.11.031.022/0330
1.11.031.101/0000| integriert / incl.
Table 3.1 For additional technical data, please refer to the catalogue.
The information in this data sheet only contains general descriptions and / or performance features, which may not apply precisely as described to the respective application, and which my change due to further product enhancements. The technical data, illustrations and other information about our products are the mere results of individual technical testing. These descriptions and other product features are only binding if they expressly agreed upon at the time of the conclusion of a binding contract. In all other cases, we reserve the right to make technical changes as well as changes of availability. Pictures and other graphic illustrations are approximations only. All product names may be trademarks or brand names of the RAFI Group or any other sub-supplier of RAFI. The use of such by any third parties for their own purposes may infringe the rights of the respective entity holding those rights.
RAFI GmbH & Co. KG
Ravensburger Str. 128-134