VOLLRATH 72723019 Food Processing Equipment
Specifications:
- Model: 17030-1 ml
- Language Options: English, Spanish, French
- Revision Date: 09/14
Product Usage Instructions
Safety Precautions:
To ensure safe operation, please read and understand the following safety
precautions:
- Warning: Indicates a hazard that can cause severe personal injury, death, or property damage if ignored.
- Caution: Indicates a hazard that can cause minor personal injury or property damage if ignored.
- Note: Provides important non-hazard related information.
For Your Safety!
Follow these precautions at all times to prevent injury or equipment damage:
- Use only grounded electrical outlets matching the rated voltage.
- Operate the unit on a flat, level surface.
- Turn off and allow the unit to cool before cleaning or moving.
- Avoid operating the unit unattended.
Unit Installation Clearances:
Follow these clearances to ensure the safe installation of the unit:
- Fire Hazard: Do not place near combustible materials.
- Electrical Shock Hazard: Keep liquids away from the unit to prevent electrical shock.
- Ensure proper distances from combustible and non-combustible surroundings as specified in the manual.
- Use only coated light bulbs meeting NSF standards in food service areas.
- Avoid contact with liquids or cleaning agents on control or exterior units.
FAQ
Q: What should I do if I encounter a warning or caution indication?
A: Take immediate action as per the warning or caution message to prevent injury or damage.
Q: Can I use an extension cord with the unit?
A: No, do not use extension cords, power strips, or surge protectors with this unit to ensure safety.
Q: What should I do if I need service for the unit?
A: Contact a Vollrath Authorized Service Agent for any required service using genuine Vollrath replacement parts to maintain warranty and safety standards.
Overview
REGISTER YOUR PRODUCT ON-LINE AT WWW.VOLLRATH.COM.
Thank you for purchasing this Vollrath Food Processing Equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Save the original box and packaging. Use this packaging to ship the equipment if repairs are needed.
SAFETY PRECAUTIONS
To ensure safe operation, read the following statements and understand their meaning. This manual contains safety precautions which are explained below. Please read carefully.
WARNING
The warning is used to indicate the presence of a hazard that can cause severe
personal injury, death, or substantial property damage if the warning is
ignored.
CAUTION
Caution is used to indicate the presence of a hazard that will or can cause
minor personal injury or property damage if the caution is ignored.
NOTE
The note is used to notify people of installation, operation, or maintenance
information that is important but not hazard-related.
For Your Safety!
- These precautions should be followed at all times. Failure to follow these precautions could result in injury to yourself and others or damage to the equipment.
- To reduce the risk of injury or damage to the unit:
- Use only grounded electrical outlets or circuits matching the nameplate-rated voltage.
- The unit should only be used in a flat, level position.
- Turn off the unit and let it cool before cleaning or moving.
- Do not operate unattended.
- Do not use extension cords, power strips or surge protectors with this unit.
- Install with distances specified in the Unit Installation section of this manual. Minimum distance to the following surfaces.
- Combustible surroundings 5” Sides 2” Top
- Non Combustible surroundings 1” Sides 1” Top
- Setback from the edge of pass-through 8” from any edge
- Units that require wiring for installation must follow National Electrical Code (NEC) standards and local ordinances.
- Only use coated light bulbs that meet NSF standards and are specifically designed for food service areas. Breakage of bulbs that are not coated could cause injury or contaminate food.
- Do not place materials on or allow combustible materials to come in contact with the unit.
- There are no serviceable parts in this unit. Contact a Vollrath Authorized Service Agent for service.
- Authorized service agents must use genuine Vollrath replacement parts. Failure to do so will void the warranty and may cause a safety hazard.
- Do not spray controls outside of the unit with liquids or cleaning agents.
- Units that require a circuit breaker larger than 20 amps must have separate circuits for the lighting circuit that is less than 20 amps.
FUNCTION AND PURPOSE
- Heat Strips = These units are intended to be used as a heat source to help maintain food at safe temperatures until served. They are not intended or designed to cook raw food or to reheat prepared food. Food must be prepared and placed in food stations at proper temperatures.
- Light Strips = These units are intended to illuminate food serving display areas or food preparation areas.
UNPACKING THE EQUIPMENT AND INITIAL SETUP
Carefully remove crating or packaging materials from the unit. Dispose of
all packaging, materials in an environmentally responsible manner.
UNIT INSTALLATION CLEARANCES
WARNING
Fire Hazard.
Do not install units near combustible material. Do not place combustible
material under or on top of the unit. Discolouration or combustion could
occur.
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the inside of the unit. The liquid
inside the unit could cause an electrical shock. The unit must be installed by
qualified personnel by all local and national ordinances. Do not use a power
cord that has been modified or damaged.
This unit must be installed by qualified personnel in compliance with electrical codes. The following distances must be kept between the unit and the surrounding surfaces for safe operation. It is recommended that two (2) or more people assist with the installation of this unit.
Minimum Clearances| Single
Non-Combustible Surface
| Single Combustible Surface| Dual Non-Combustible Surface| Dual Combustible
Surface
---|---|---|---|---
A Top of strip to surface above (minimum)| 1″ (2.5 cm)| 2″ (5.1 cm)| 1″ (2.5
cm)| 2″ (5.1 cm)
B Bottom of strip to surface below| Medium Wattage| 11″ (27.9 cm)| 13″ (33.0
cm)| 18″ (45.7 cm)| 20″ (50.8 cm)
High Wattage| 16″ (40.6 cm)| 16″ (40.6 cm)| 24″ (60.9 cm)| 25″ (63.5 cm)
C Side of the strip to the adjacent surface (minimum)| 1″ (2.5 cm)| 5″ (12.7
cm)| 1″ (2.5 cm)| 5″ (12.7 cm)
Setback from front opening on pass-through application: maximum of 8″ (20.3
cm)
NOTE:
This unit must be installed in an area that will not be affected by the heat
from the unit. Damage to solid surface countertops or other materials in the
heat zone of this product is not covered under warranty.
Installation
KOOL-TOUCH® TRIM INSTALLATION
The Kool-Touch® trim option is shipped separately. It will need to be
installed on the unit. We recommend that this option be installed before the
unit is mounted.
- Beginning on the side that does not have the control box (A), slide the Kool-Touch® (B) panel into position by starting at one end of the unit. Slide the Kool-Touch® panel in channel (C) on the side of the unit until it is in place. (Ganged units will require two pieces trimmed to fit). See Figure 1.
- The side of the unit that has the control box will need to be trimmed. Measure the area that is to be covered by the Kool-Touch® panel.
- Mark the length to be covered on the Kool-Touch® panel.
- Place a damp soft cloth under the end of the Kool-Touch® panel to be cut to prevent the Kool-Touch® panel from scratching or slipping while it is being cut.
- Using a hacksaw with a fine metal or plastic blade, slowly cut the panel to length.
- Install the panel on the unit in the same manner as the opposite side.
Unit Installation – Direct Wire Mounting
Top Mount Installation
Top mount brackets may be purchased as an option for direct-wired units. The
brackets are available in 1” height or 2” height. Dual units require two sets
of brackets.
NOTE:
Top mount brackets may not be used with units longer than 72”.
- Access the area the unit will be mounted in and mark the location where the centre mount brackets will be mounted. Make sure the material the unit will be mounted to will support the weight of the unit.
- Secure the top mount bracket (A) to the mounting holes (B) using lockwashers (C) and screws (D). Repeat on the other end. See Figure 2.
- Mount the brackets and unit to a suitable surface using holes (E) and suitable hardware.
Center Mount Installation
Top mount brackets may be purchased as an option for direct-wired units. The
brackets are available in 1” height or 2” height. Dual units require brackets
on each unit.
NOTE:
For units longer than 72”, a minimum of three (3) mounting points consisting
of the two ends and the centre of the unit must be used.
- Access the area the unit will be mounted in and mark the location where the centre mount brackets will be mounted. Make sure the material the unit will be mounted to will support the weight of the unit.
- The brackets must be located near the ends of the unit for greatest stability.
- Mount the hanging bracket (A) with the “T” slot cutout, in the locations identified in Step 1. Figure 3.
- Loosen the two screws (B) located in the centre of the flat channel plates (C) far enough so they do not protrude out of the bottom of the plate.
- Slide the channel plates (C) into the channel (D) on the top of the unit.
- Measure the distance from the centre points of the hanging brackets (A) and slide the channel plates (C) in the channel (D) on the top of the unit so the centre screws (E) in the channel plate (C) match the distance between the centre of the “T” slot (G) in the brackets (A).
- Tighten the two outside screws (B) in the channel plate (C) to lock the channel plate in position.
- Loosen the nut (F) in the center of the channel plate (C) but DO NOT REMOVE.
- Raise the unit and align the nut (F) in the centre of the channel plate (C) with the “T” in the bracket (A) mounted in step 2.
- Slide the nut (F) through the “T” slot and TIGHTEN THE NUT to keep the unit in place. THE NUT MUST BE TIGHTENED TO PREVENT THE UNIT FROM SLIPPING OUT OF THE BRACKET.
Chain Mount Installation
NOTE:
Units over 72” in length, must use the centre mounting point.
- The unit is shipped with mounting tabs (A) located on each end of the unit. For units that are longer than 72”, three (3) mounting points consisting of the two ends and the centre of the unit must be used. See Figure 4.
- Loosen the screws (B) holding the mounting tabs in place but do not remove them. Rotate tabs (A) to an upright position and the attach chain to holes (C). The chain must support each side of each end of the unit evenly.
- Hang the chain from an appropriate hanging point directly over the area to be kept warm. Make sure the hanging point is adequate for the total weight of the unit and chain.
- Adjust the height of the unit making sure it is level and each point is supporting the weight of the unit evenly.
- Tighten screws (B) to secure the mounting tabs.
Remote Mounting of Control(s)
NOTE:
Installations must be by National Electrical Code (NEC) regulations.
Control boxes must be mounted securely to surfaces using proper hardware. Mount the control box(es) in such a way they will not be bumped or accidently switched on or off.
- A. ON/OFF Toggle Switch. Move the toggle switch to the up position for “ON”. Move the toggle switch to the down position for “OFF”. The switch(es) may operate a heating element(s) or light(s).
- B. INFINITE HEAT CONTROL. Rotate the INFINITE HEAT CONTROL off zero “0” to turn control on. Rotate to desired heat.
Unit Installation – Corded Mounting
On Board Toggle Controls
A. ON/OFF Toggle Switch. Move the toggle switch to the up position for “ON”. Move the toggle switch to the down position for “OFF”.
Mounting Options
NOTE:
UL requires all cord and plug heat strips, from all manufacturers to be
mounted on legs. All heat strips are custom ordered and therefore cannot be
cancelled or returned per Vollrath’s Terms and Conditions.
Operation
WARNING
Burn Hazard.
Do not touch heating surfaces, liquid, or while the unit is heating or
operating. Hot food, surfaces, steam and liquids can burn skin. Use gloves,
mitts or pot holders if it is necessary to handle hot pans, plates and
equipment.
WARNING
Fire Hazard.
- Do not install units near combustible material. Do not place combustible material under or on top of the unit.
- Discolouration or combustion could occur.
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the inside of the unit. The liquid
inside the unit could cause an electrical shock. Unit must be installed by
qualified personnel by all local and national ordinances. Do not use a power
cord that has been modified or damaged.
NOTE:
Certain containers such as foam or plastic may melt if left in the heat zone.
Also, food left in the heat zone may begin to dry if left in the heat zone for
an extended time.
-
Make sure there are no combustible materials in contact with or near the food-warming unit.
-
Turn the heat switch(es) to the “ON” position or set the INFINITE HEAT CONTROL to the desired setting. Allow the unit to preheat for approximately 15 minutes before placing food in the heat zone.
-
If the unit is equipped with lights, switch the lights on.
-
Place food items to be kept warm in the heat zone. Regularly check the food temperature. Adjust controls as necessary. See Note:
NOTE:
Monitor food temperature closely for food safety. The United States Public Health Service recommends that hot food be held at a minimum of 140 ºF (60 ºC) to help prevent bacteria growth. Maintain correct water level and temperature setting. Periodically remove the food container and check the water level. Add water if needed. -
When not in use turn the heat switch(es) to the “OFF” position or rotate the infinite heat control to the zero (0) position. Turn the lights to the “OFF” position.
ADJUSTING THE HEAT REFLECTOR
The heat strip units have been equipped with a directional heat reflector to
allow the heat zone to be directed to best suit each application.
- Turn the switch(es) to the “OFF” position(s). Allow the unit to cool completely before continuing.
- Make sure the unit is cool. This is for safety and the reflector can be moved more easily when the unit is at room temperature.
- Remove the small screws (A) from the holes on the end alignment plates. There is one screw on each side of the end plate that secures the reflector. See Figure 10.
- Pivot the reflector in the desired direction.
- There are 3 alignment screw holes to choose from that are located on the outside end of the unit. Align the screw hole in the reflector end with the appropriate hole in the end plate for the desired direction of the reflector.
- Place the screws in the appropriate location and tighten them.
CLEANING
WARNING
Burn Hazard.
Hot surfaces can burn the skin. Allow the unit to cool completely before
cleaning.
WARNING
Electrical Shock Hazard.
- Do not spray the unit or controls with liquid or cleaning products
- Liquid could enter the electrical compartment and cause a short circuit or electric shock.
- Turn the power switch(es) off. Turn the light switch(es) off. Allow the unit to completely cool.
- Wipe the unit exterior with a clean damp cloth.
- Do not use abrasive materials, scratching cleansers or scouring pads to clean the unit. These can damage the finish.
- Thoroughly wipe off any mild soap or chemical cleaners. The residue could corrode the surface of the unit.
TROUBLESHOOTING
Problem | It might be caused by | Course of Action |
---|---|---|
The unit is switched “ON” but there is no heat. | No power to the unit. | Check |
that there is power to the outlet. Reset the circuit breaker if necessary.
Defective switch.| Replace the switch.
Wiring or heating element problem.| Check that all wires are good. Check that
the element connection is good. Check elements and replace them if necessary.
The unit is on, but low heat.| The unit is mounted too high above the heating
zone.| Re-mount the unit lower, placing heat closer to the heating zone. See
the Unit Installation Clearances chart on page 2.
Excess cold air circulation around the heating zone or unit.| Restrict or
redirect air movement away from the heating zone or unit.
Incorrect power supply (low).| Check that the power supply matches the
nameplate-rated voltage.
Lights or switches burn out after a short time.| Check mounting height. If the
unit is too low, the unit will overheat.| Check that the unit is mounted as
specified in the Unit Installation Clearances chart on page 2. If the
unit is not at the correct height, remount the unit.
Wiring Diagram
120 Volt Heater W/Infinate Control Assembly Wiring Diagram
120 Volt Heater W/Toggle Switch Control Assembly Wiring Diagram
208 – 240 Volt Heater W/Infinate Control Assembly Wiring Diagram
208 – 240 Volt Heater W/Toggle Switch Control Assembly Wiring Diagram
SERVICE AND REPAIR
There are no user-serviceable parts within this appliance. To avoid serious injury or damage, never attempt to repair the equipment or replace a damaged power cord yourself. Do not send equipment directly to The Vollrath Company LLC. Please contact Vollrath Technical Service from the list below.
VOLLRATH Technical Service
When contacting Vollrath Technical Service, please be ready with the item number, model number (if applicable), serial number, and proof of purchase showing the date the unit was purchased.
WARRANTY STATEMENT
WARRANTY STATEMENT FOR THE VOLLRATH CO. L.L.C.
This warranty does not apply to products purchased for personal, family or
household use, and The Vollrath Company LLC does not offer a written warranty
to purchasers for such uses.
The Vollrath Company LLC warrants each of its products listed below against defects in materials and workmanship for the applicable period provided below. All other products manufactured or distributed by The Vollrath Company LLC are warranted against defects in materials and workmanship for one year. In all cases, the warranty runs from the date of the end user’s original purchase date found on the receipt. Any damages from improper use, abuse, modification or damage resulting from improper packaging during return shipment for warranty repair will not be covered under warranty.
- Cayenne® Heat Strips, heating element only – The warranty period is 2 years.
- For refrigeration compressors and the second year of the warranty on Cayenne® Heat Strips and mixers, The Vollrath Company LLC will provide the part only; and the buyer will be responsible for all labour charges incurred in performing the repair or replacement.
- Replacement parts – The warranty period is 90 days.
- Glass, Breath Guard Glass and Light Bulbs are not covered by warranty.
For complete warranty information, product registration and new product announcement, visit www.vollrath.com.
- The Vollrath Company, L.L.C. 1236 North 18th Street Sheboygan, WI 53081-3201 U.S.A.
- Main Tel: 800.628.0830
- Fax: 800.752.5620
- Technical Services: 800.628.0832
- Service Fax: 920.459.5462
- Canada Service: 800.695.8560
© 2014 The Vollrath Company, L.L.C.