Cobra 036I400PSW Pure Sine 400w Power Inverter User Guide
- June 1, 2024
- Cobra
Table of Contents
036I400PSW Pure Sine 400w Power Inverter
“`html
Product Specifications:
-
Model: Pure Sine 400W Power Inverter
-
Power Output: 400W
-
Waveform: Pure Sine Wave
-
Input Voltage: 12V DC
-
Output Voltage: 120V AC
-
USB Ports: USB-A Fast Charge port (5V/9V/15W), USB-C Fast
Charge port (5V/9V/15W) -
AC Outlets: (2) GFCI Protected AC Outlets
Product Usage Instructions:
Connecting Directly To A Vehicle Battery:
-
Mount the inverter inside the vehicle in a well-ventilated
location close to the battery. -
Disconnect the NEGATIVE (-) or black battery terminal of the
vehicle. -
Route cables close to the battery.
-
Install the insulated terminal boots on the inverter end of the
power cables (RED = positive, BLACK = negative). -
Connect the BLACK Cable to the Negative(-) terminal on the
Inverter. -
Connect the RED Cable to the Positive (+) terminal on the
Inverter. -
Connect the other end of the RED cable to the (+) terminal on
the vehicle battery. -
Visually inspect and make sure the red wire or its connectors
are not touching any metal parts of the vehicle or the black wire
connectors. -
Connect the other end of the BLACK cable to the (-) terminal on
the vehicle battery. Caution: There is normally a spark at the
point of contact at the negative terminal. -
Check all connections making sure the RED cable is connected to
the POSITIVE (+) terminals and the BLACK cable is connected to the
NEGATIVE (-) terminals. -
Press the POWER button to turn on your inverter.
Connecting To A Vehicle Accessory Port:
-
Mount your inverter in a well-ventilated area of the
vehicle. -
Remove the thumb cap on the inverter for each terminal.
-
Connect the RED (+) 12V Accessory Cable ring terminal to the
RED(+) inverter terminal. -
Screw the thumb cap back on the RED (+) inverter terminal.
-
Connect the BLACK (-) 12V Accessory Cable ring terminal to the
BLACK (-) inverter terminal. -
Screw the thumb cap back on the BLACK(-) inverter
terminal. -
Plug the 12V Accessory Cable into a vehicle accessory
port. -
Place the power switch into the ON position by pressing the
left side of the switch to turn ON your inverter. Place the power
switch into the OFF position by pressing the right side of the
switch to turn OFF your inverter.
Frequently Asked Questions (FAQ):
Q: What is the maximum load supported by the 12V Accessory
Cable and how do I prevent overload?
A: The 12V Accessory Cable can support on average up to 120
Watts. To prevent overload, please refer to your vehicle manual for
the maximum load your vehicle’s accessory port can handle.
“`
Cobra®
PURE SINE 400W
POWER INVERTER
(Sold Separately)
QUICK START GUIDE
Connecting Directly To A Vehicle Battery
(Please Refer to Diagram on Previous Page)
1. Mount the inverter inside the vehicle in a well ventilated location close
to the battery
2. Disconnect the NEGATIVE (-) or black battery terminal of the vehicle
3. Route cables close to the battery
4. Install the insulated terminal boots on the inverter end of the power
cables (RED = positive, BLACK = negative)
5. Connect the BLACK Cable to the Negative(-) terminal on the Inverter
6. Connect the RED Cable to the Positive (+) terminal on the Inverter
7. Connect the other end of the RED cable to the (+) terminal on the vehicle
battery
8. Visually inspect and make sure the red wire or its connectors are not
touching any metal parts of the vehicle or the black wire connectors
9. Connect the other end of the BLACK cable to the(-) terminal on the vehicle
battery. Caution: There is normally a spark at the point of contact at the
negative terminal
10. Check all connections making sure the RED cable is connected to the
POSITIVE (+) terminals and the BLACK cable is connected to the NEGATIVE (-)
terminals
11. Press the POWER button to turn on your inverter
Connecting To A Vehicle Accessory Port
Connect the BLACK 12V Accessory Cable to the Negative Post on the Power Inverter
Connect the RED 12V Accessory Cable to the Positive Post on the Power Inverter
A
Be sure the cables are correctly connected
–
·Plug the 12V Accessory Cable
into the Vehicle Accessory Port*
1. Mount your inverter in a well-ventilated area of vehicle
2. Remove the thumb cap on the inverter for each terminal
3. Connect the RED (+) 12V Accessory Cable ring terminal to the RED(+)
inverter terminal.
4. Screw the thumb cap back on the RED (+) inverter terminal
5. Connect the BLACK (-) 12V Accessory Cable ring terminal to the BLACK (-)
inverter terminal.
6. Screw the thumb cap back on the BLACK(-) inverter terminal
7. Plug the 12V Accessory Cable into vehicle accessory port
8. Place the power switch into the ON position by pressing the left side of
the switch to turn ON your inverter. Place the power switch into the OFF
position by pressing the right side of the switch to turn OFF your inverter
The 12V Accessory Cable can support on average up to 120 Watts. Do not overload . Please refer to your vehicle manual for the maximum load your vehicle’s accessory port can handle
PURE SINE 400W Features
+ @
0
[Q]
A. Negative Power Input Terminal
B. Cooling Fan – regulate the temperature of the inverter, turning on when
temperature exceeds the preset limit, and turning off
when the temperature reduces
C. Positive Power Input Terminal
D. USB-A Fast Charge port (5V/9V/15W)
E. Power/Fault LED Indicator
F. USB-C Fast Charge port (5V/9V/15W)
G. Port for Cobra Remote On/Off Controller with Fast Charge USB (Sold
Separately)
H. (2) GFCI Protected AC Outlets
I. Power Switch
J. Power Cables
K. 12 Volt Accessory Cable (for vehicle accessory port) L. Cobra Remote On/Off
Controller with
Fast Charge USB (Sold Separately)
·
. iJ *Model CPIALCDG 1
I
Connecting Directly To A Vehicle Battery
(Instruction on the Following Page)
Connect the BLACK Cable to the Negative Post on the Power Inverter
–
+ @
0
Connect the RED Cable to the Positive Post on the Power Inverter
Connect the Negative and Positive Cables to
the Negative and Positive Terminals on the Vehicle Battery
A
Be sure the cables are correctly connected
L~J
–
To Vehicle
· i Electrical System
To Vehicle
i ·Electrical System Continued )
Thank you for purchasing the Cobra PURE SINE 400 Watt Inverter (Model
CPl400PSW)
Ideal for travelers and outdoor enthusiasts who want to power devices and
equipment as if they were home. Also perfect for specialty and medical
equipment. Count on Cobra for Power Where You Need It.
Download the full CPl400PSW manual at:
cobra.com/manuals
Cobra® and the snake design are registered trademarks of Cobra Electronics
Corporation, USA. Cobra Electronics CorporationTM is a trademark of Cobra
Electronics Corporation, USA. Other trademarks and trade names are those of
their respective owners.
©2020 Cobra Electronics Corporation
1|Page
©2020 Cobra Electronics Corporation
Version A
Table of Contents
Table of Contents ……………………………………………………………………………………………………. 2 INTRODUCTION
………………………………………………………………………………………………………. 3 HOW YOUR POWER INVERTER
WORKS……………………………………………………………………….. 3 WHAT’S IN THE BOX
………………………………………………………………………………………………… 3 OPTIONAL
ACCESSORIES…………………………………………………………………………………………… 3 CONTROLS AND CONNECTIONS
…………………………………………………………………………………. 4 IMPORTANT PRODUCT/SAFETY INFORMATION
……………………………………………………………. 6 PENTAGON
PROTECTION®………………………………………………………………………………………… 7 GETTING
STARTED…………………………………………………………………………………………………… 8 POWER CONSUMPTION
…………………………………………………………………………………………… 8 MOUNTING THE INVERTER
……………………………………………………………………………………….. 9 PURE SINE 400W
INSTALLATION………………………………………………………………………………..10 CONNECTING TO THE
BATTERY………………………………………………………………………………….11 PURE SINE 400W 12V ACCESSORY
INSTALLATION …………………………………………………………12 CONNECTING TO THE 12V
ACCESSORY………………………………………………………………………..13 TURNING YOUR INVERTER ON AND OFF
……………………………………………………………………..15 COBRA REMOTE ON/OFF CONTROLLER WITH FAST CHARGE
USB ……………………………………15 OPERATING INDICATORS
………………………………………………………………………………………….16 OPERATING
LIMITS………………………………………………………………………………………………….16 TROUBLESHOOTING
………………………………………………………………………………………………..17 SPECIFICATIONS
……………………………………………………………………………………………………..18 WARRANTY & TRADEMARK
ACKNOWLEDGEMENT……………………………………………………….19 MAINTENANCE & PRODUCT
SERVICE………………………………………………………………………….20
2|Page
INTRODUCTION
Thank you for purchasing the Cobra PURE SINE 400W Power Inverter (Model
CPI400PSW). Your inverter is designed with “Pure Sine Wave,” a wave form
identical to AC power you use inside your home. Rely on Pure Sine Wave to
operate your sensitive electronics such as medical equipment (i.e. CPAP or
nebulizer), audio/video systems, programmable appliances, computers,
communications equipment, and appliances designed with an inductive motor
properly and more efficiently. Your appliances will “thank you” for it. Use
this inverter to power AC appliances inside your vehicle. The inverter is
designed to power continuously from a 12 Volt DC source (i.e. vehicle
battery). Used properly, this Cobra product will give you reliable power to
run your appliances and devices. Please read this manual thoroughly before you
install and set up your new power inverter.
HOW YOUR POWER INVERTER WORKS
The Cobra PURE SINE 400W Power Inverter is a power conversion device that is
designed and built to operate from low Voltage DC (Direct Current) power from
your vehicle battery and converts it to standard 115 Volt AC (Alternating
Current) power like you have in your home. This conversion process allows you
to use many of your household appliances and electronic products in
automobiles, RVs, boats, trucks and virtually anywhere else with a 12 Volt
battery.
PRODUCT SERVICE AND SUPPORT
For any questions about operating or installing this new Cobra product, PLEASE
CONTACT COBRA FIRST…do not return this product to the retail store. The
contact information for Cobra will vary depending on the country in which you
purchased and utilize the product. For the latest contact information, please
go to www.cobra.com/support or call
1-800-543-1608.
If your product should require factory service, please go to
www.cobra.com/support and follow the instructions.
WHAT’S IN THE BOX
· Cobra CPI400PSW Power Inverter · 16″ #12 AWG Power Cables · 16″ 12-Volt
Accessory Cable · Quick Start Guide
OPTIONAL ACCESSORIES available at www.cobra.com
· CPIALCDG1 – Remote On/Off controller with Fast Charge USB
3|Page
CONTROLS AND CONNECTIONS
4|Page
A. Negative Power Input Terminal B. Cooling Fans regulate the temperature of
the inverter, turning on when
temperature exceeds the preset limit, and turning off when the temperature
reduces C. Positive Power Input Terminal D. USB-A Fast Charge port
(5V/9V/15W) E. Power/Fault LED Indicator F. USB-C Fast Charge port
(5V/9V/15W) G. Port for Cobra Remote On/Off Controller with Fast Charge USB
(Sold Separately) H. (2) GFCI Protected AC Outlets I. Power Switch J. Power
Cables K. 12 Volt Accessory Cable (for vehicle accessory port) L Cobra Remote
On/Off Controller with Fast Charge USB (Sold Separately)
** = Fast Charge works only on devices capable of supporting a charge up to
10W
5|Page
IMPORTANT PRODUCT /SAFETY INFORMATION
Before installing and using your Cobra power inverter, please read these
general precautions and warnings. Caution and Warning Statements Special
attention must be paid to the CAUTION and WARNING statements in the manual.
CAUTION: Statements specify conditions which could cause damage to the unit or
other equipment. WARNING: Statements identify conditions that could result in
personal injury or loss of life. General Precautions 1. Never install the
inverter in a boat’s engine compartment where gas and battery fumes are
present. 2. Do not operate the inverter if it has been dropped or damaged in
any way. 3. Do not open the inverter; it contains no user-serviceable parts.
Attempting to service unit could
cause electrical shock. NOTE: Internal components remain charged after all
power is disconnected. 3. Do not expose the inverter to rain, snow, bilge
water or spray. 4. Do not obstruct the ventilation openings. 5. Do not install
the inverter in zero-clearance compartment. 6. Do not allow water or liquids
in contact with the power inverter 7. Do not use appliances with damaged or
wet cords.
CAUTION: This inverter should be used in negative ground applications only.
CAUTION: The inverter must only be connected to batteries with a nominal
output voltage of 12 volts. Do not connect the power inverter to a 6 Volt
battery and will be damaged if connected to a 24 Volt battery.
WARNING: Power inverters contain components that tend to produce arcs or
sparks. To prevent fire or explosion, do not install the inverter in areas or
compartments containing batteries or flammable materials or in locations that
require ignition-protected equipment.
WARNING: To avoid fire, do not cover or obstruct the ventilation openings. Do
not install the power inverter in a tight space or closed compartment where
airflow may be restricted.
Proposition 65: Warning: Wash Hands After Handling Power Cord The power cord
on this product contains lead, a chemical known in the state of California to
cause birth defects or other reproductive harm.
6|Page
Caution: Rechargeable Appliances Certain chargers for small nickel cadmium
batteries can be damaged if connected to a Cobra POWER 400PSW inverter. Two
particular types of equipment are prone to this problem: 1. Small battery-
operated appliances such as flashlights, razors, and night lights that can be
plugged directly into an AC receptacle to recharge. 2. Certain battery
chargers for battery packs used in hand power tools. These chargers have a
WARNING label stating that dangerous voltages are present at the battery
terminals.
This problem does not occur with the vast majority of battery operated
equipment. Most use a separate charger or transformer that is plugged into the
AC receptacle and produces a low voltage output. If the label on the AC
adapter or charger states that it produces a low voltage AC or DC output (less
than 30 volts), the inverter will have no problem powering the adapter safely.
PENTAGON PROTECTION®
Cobra power inverters provide five levels of protection: 1. Over-Temperature:
Auto-shut off will occur when the safe operating temperature has been
exceeded. 2. Reverse Polarity: The inverter will not operate if connected
incorrectly to the power source. 3. Over-Voltage: Auto-shutdown will occur if
the DC input exceeds safe operating levels. 4. Low Voltage Alarm: The inverter
will sound an alarm to indicate a low battery voltage condition. 5. Low
Voltage Cutoff: The inverter will automatically shut off to prevent a dead
battery condition.
For detailed specifications go to Specifications section of this manual,
starting on page 18.
7|Page
GETTING STARTED
This section provides you with the basic information about the inverter and a
few tips before installation. To get started, you will need: 1. A 12 Volt DC
battery (i.e. vehicle battery. In order to understand how much current your
battery must
deliver, divide the number of Watts from your AC appliance or device by 10. 2.
Cables to connect your inverter to the vehicle battery. These come with your
PURE SINE 400W
Inverter and provide a length of 16″. If you need to install the inverter
permanently, longer cable is required with a larger gauge. DETERMINING THE
POWER REQUIREMENTS FOR YOUR PRO INVERTER Before you turn on your power
inverter and plug in an appliance or device, you will want to understand its
power requirements. To determine the requirements, you will need to know the
Watts of your device. This can be calculated by multiplying the Amps by 110
Volts (See Below).
POWER CONSUMPTION
For each piece of equipment you will be operating from the power inverter, you
must determine the battery’s reserve capacity (how long the battery can
deliver a specific amount of current in automotive batteries, usually 25
ampere) or ampere-hour capacity (a measure of how many amperes a battery can
deliver for a specified length of time). Example Ampere-hour capacity: a
battery with an ampere-hour capacity of 100 ampere-hours can deliver 5 ampere
for 20 hours before it is completely discharged. To determine the battery
Ampere-hour capacity you require: 1. Determine how many Watts each piece of
equipment consumes. This can normally be found on the
product label. If only the Amperage is provided, then multiply the Amps by 115
to determine the power in Watts. 2. Estimate how long you need your appliance
to run. 3. Now calculate the Amp-hour rating for the battery. You can do this
by multiplying the total AC load (in Watts) by the length of time (in Hours)
needed to run your appliance. This will give you the Watt-Hours needed.
4. Divide the watt-hours by 10 to determine how many battery (12 volt)
ampere-hours will be consumed.
8|Page
Multiply: AC AMPS X 110 (AC Voltage) = WATTS. This formula yields a close
approximation of the continuous load of your appliance. Multiply: WATTS X 2 =
Starting load for most appliances, tools and devices. This formula yields a
close approximation of the starting load for most appliances. Exceptions are
motorized appliances such as pumps, freezers, and air conditioners. These
appliances can have startup loads of up to eight times the rated Watts.
Determining the DC Power Requirements Your power inverter requires the input
of a 12-Volt battery. To calculate the approximate power in Amps as 12-Volt
battery bank you need to know the current, or Amps required for powering the
continuous AC load. A shortcut method is to divide the continuous AC load
Wattage by 10. For example, the continuous AC load is 400 Watts. The current
(Amps) is: 400/10 or 40 Amps at 12VDC. Add to the load any DC appliances that
may be powered by the battery bank.
MOUNTING THE INVERTER
Do not mount the power inverter under the hood of any vehicle. Choose a cool,
dry, and well-ventilated area inside the vehicle as close to the battery as
possible. Place the power inverter on a flat, secure surface. Make sure there
are no wires, fuel lines or fluid tanks directly behind the wall or surface
being drilled. When mounting, secure the power inverter in place using
corrosion-resistant mounting hardware (not included). What you will need:
· Assess your mounting needs depending
on the inverter and type of surface you are mounting (i.e. wood or fiber
glass)
· Gather the necessary tools depending
on the surface (i.e. drill or screwdriver)
· Determine size of mounting hardware.
Use only corrosive resistant screws (not included) Mounting Instructions: 1.
Make sure the inverter is OFF. 2. Check for wires, fuel lines or fluid tanks
behind the wall or surface you plan to drill. 3. Position the power inverter
horizontally when choosing the mounting location. If mounted on a wall
be sure the front of the inverter is facing out. Do not mount vertically to
prevent debris or dust from falling into the power inverter.
4. Mark the locations of the mounting screws before drilling. 5. Remove the
inverter and drill the (4) mounting holes. 6. Fasten the inverter to the
mounting surface using corrosion-resistant screws (not included).
9|Page
PURE SINE 400W INSTALLATION
10 | P a g e
CONNECTING TO THE BATTERY
1. Mount the inverter inside the vehicle in a well ventilated location close
to the battery.
2. Disconnect the NEGATIVE (-) or black battery terminal of the vehicle.
3. Route cables close to the battery.
4. Install the insulated terminal boots on the inverter end of the power
cables (RED = positive, BLACK = negative).
5. Connect the BLACK Cable to the Negative (-) terminal on the inverter.
6. Connect the RED Cable to the Positive (+) terminal on the inverter.
7. Connect the other end of the RED cable to the (+) terminal on the vehicle
battery.
8. Visually inspect and make sure the red wire or its connectors are not
touching any metal parts of the vehicle or the black wire connectors.
9. Connect the other end of the BLACK cable to the (-) terminal on the
vehicle battery. Caution: There is normally a spark at the point of contact at
the negative terminal.
10. Check all connections making sure the RED cable is connected to the
POSITIVE (+) terminals and the BLACK cable is connected to the NEGATIVE (-)
terminals.
11. Press the POWER button to turn on your inverter.
12. If you purchased the Cobra Remote On/Off Remote Controller with Fast
Charge USB (Model CPIALCDG1) accessory, plug the controller into the RJ45 jack
labeled “REMOTE”.
11 | P a g e
PURE SINE 400W 12V ACCESSORY INSTALLATION
12 | P a g e
CONNECTING TO THE 12V ACCESSORY
1. Mount your inverter in a well-ventilated area of vehicle. 2. Remove the
thumb cap on the inverter for each terminal. 3. Connect the RED (+) 12V
Accessory Cable ring to the RED (+)
inverter terminal. 4. Screw the thumb cap back on the RED (+) inverter
terminal. 5. Connect the BLACK (-) 12V Accessory Cable ring to the BLACK (-)
inverter terminal. 6. Screw the thumb cap back on the BLACK (-) inverter
terminal. 7. Make sure the inverter is in the OFF position “O”. 8. Plug the
12V Accessory Cable into vehicle accessory port*. 9. When turning your
inverter ON, place the power switch into the ON or “-”
position by pressing the left side of the switch. When turning your inverter
OFF, place the power switch into the OFF or “O” position by pressing the right
side of the Power Switch.
13 | P a g e
CAUTION: Do not connect the inverter and another AC source (such as a
generator or utility power) to the AC wiring at the same time. The inverter
will be damaged if its output is connected to AC voltage from another source.
Damage can even occur if the inverter is switched off.
CAUTION: Do not connect the inverter to a load greater than 400 Watts.
CAUTION: It is not recommended to operate loads at the maximum rated output
for permanent or extended periods of time. For continuous operation (greater
than 60 minutes), it is recommended to operate a load 20% less than the
inverter maximum output rating. For example, for a 400 Watt inverter, a
maximum load of 320 Watts is recommended.
CAUTION: Loose connectors result in excessive voltage drop and may cause over
heated wires and melted insulation.
CAUTION: Reverse polarity connections (positive to negative) will blow
internal fuses in the inverter and may permanently damage the unit. Such
damage is not covered by the warranty.
CAUTION We recommend a main fuse in the battery’s positive cable to protect
against DC wiring short circuits (external to the inverter). The fuse should
be as close to the battery as possible. We recommend a 50 Amp ANL fuse or
equivalent. The specific fuse ampere rating should be sized to allow operation
of all your DC powered equipment.
CAUTION: Remove any jewelry (watch, ring, etc.). Be careful not to short
circuit the battery with any metallic object (wrench, etc.).
CAUTION: Electrical installations must meet local and national wiring codes,
and should be performed by a qualified electrician.
WARNING: If you are making a permanent AC connection to the inverter, make
sure that the AC wiring steps are performed before any DC wiring is done. (DC
hook-up energizes internal components, regardless of the position of the
On/Off Switch). Working on AC connections in such a circumstance may result in
an electric shock.
WARNING: 115 volt AC power is potentially lethal. Do not work on AC wiring
when it is connected to the inverter (even if it is switched off) unless the
DC power source is physically disconnected from the inverter. Also, do not
work on AC wiring if it is connected to another AC power source such as a
generator or the utility line.
WARNING: You may observe a spark when making the connection because current
can flow to charge the capacitors in the inverter. Do not make this connection
in the presence of flammable fumes. Explosion or fire may result. Thoroughly
ventilate the battery compartment before making this connection.
14 | P a g e
TURNING YOUR POWER INVERTER ON AND OFF
Be sure to have your power inverter properly installed before attempting to
turn the unit on (see installation beginning on page 10) To turn the power
inverter on: 1. If a DC power supply is being used as the power source, switch
it on. 2. On the Output End, press the Power Button to on.
The power inverter is now ready to deliver AC power to your loads. If several
loads are to be operated by the inverter, turn them on separately, after the
inverter has been turned on. This will ensure that the inverter does not have
to deliver the starting currents required for all the loads at once.
NOTE: The Power Button turns the control circuit in the inverter on and off.
It does not disconnect power from the inverter. When the button is in the off
position, the inverter draws no current from the battery. When it’s in the on
position, but no power is being supplied to a load, the inverter draws less
than 600 milliamperes from the battery. This is low current draw. It would
take more than a week to discharge a 100 ampere-hour battery at this rate
depending on the age of the battery.
COBRA REMOTE ON/OFF CONTROLLER WITH FAST CHARGE USB
Your Cobra POWER inverter is equipped with an RJ-45 jack labeled “REMOTE” for
compatibility with the Cobra Remote On/Off Controller with Fast Charge USB to
allow you to conveniently turn the inverter ON and OFF from anywhere inside
your vehicle as well fast charge your devices at the same time. Perfect for
use while driving, traveling, camping or tailgating when your inverter is out
of reach. (4) mounting options allow you to install it permanently, use it
while driving in a cup holder or clip it to the back of a seat or a place
inside your vehicle.
Sold Separately. Can be purchased on www.Cobra.com
15 | P a g e
OPERATING INDICATORS
Indicators on the power inverter show the unit’s power status and alarms for
conditions that could cause it to shut down. The power and protection
indicator includes a dual color green and red light, and an alarm. Green Light
Power on The green light should remain on steady.
Red Light and/or Alarm Current overload The red light will blink
continuously, then the inverter will shutdown. The inverter will continue to
check for appropriate current levels while trying to restart the load.
DC input voltage overload The red light will turn on and the inverter will
shutdown. The inverter will continue to check for appropriate voltage levels
while trying to restart the load.
DC input voltage shortage As a warning that the voltage is getting low, the
internal alarm will sound. When the voltage is too low, the inverter will
shutdown and the light will turn red. The inverter will continue to check for
appropriate voltage levels while trying to restart the load.
Temperature overload The red light will blink, then the inverter will
shutdown. The inverter will continue to check for appropriate temperature
levels while trying to restart the load.
NOTE: A momentary sound of the internal alarm and/or flash of the red light is
normal at start up.
OPERATING LIMITS
Power Output The inverter can deliver 400 watts for about 60 minutes. The
inverter must cool for 15 minutes before it can resume operation at 400 watts.
Note: The wattage rating applies to resistive loads. The inverter will operate
most AC loads within its power rating. Some induction motors used in freezers,
pumps, and other motor-operated equipment require very high surge currents to
start. The inverter may not be able to start some of these motors even though
their rated current draw is within the inverter’s limits. The inverter will
normally start single phase induction motors rated at one-half HP or less.
Input Voltage The inverter will operate from input voltage ranging from 10
volts to 15 volts. Optimum performance will occur when the voltage is between
12 volts and 14 volts. If the voltage drops below 10.5V+/-0.3V, an audible low
battery warning will sound. The inverter will shut down if the input voltage
drops below 9.5V+/-0.3V. This protects the battery from being over-discharged.
It will restart when the input voltage exceeds 12V+/-0.3V. The inverter will
also shut down if the input voltage exceeds change to 15.5V+/-0.5V. This
protects the inverter against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be damaged if the input
voltage were to exceed 16 volts.
16 | P a g e
TROUBLESHOOTING GUIDE
Problem/Symptom Low output voltage No output voltage No output voltage aer
prolonged use
No output voltage, “Protect” indicator lighted
No output voltage No output voltage
Low baery alarm on all the me
Possible Causes Overload Low input voltage Thermal shutdown
High input voltage
Short circuit Inverter switched off No power to inverter Reverse DC polarity
Poor DC wiring Poor baery condion
on
Reduce the load.
Recharge baery. Check connecons and cable.
Allow inverter to cool o.
Reduce load, connuous operaon input current required.
Improve venlaon; make sure venlaon openings in the inverter are not
obstructed.
Reduce ambient temperature.
Make sure the inverter is connected to 12V baery.
Check regulaon or charging system.
Check load for proper operaon.
Turn inverter on.
Check wiring to inverter.
Observe correct polarity.
Check connecons.
Make sure baery is fully charged.
17 | P a g e
SPECIFICATIONS
Specifications: Model Input Output Output Waveform Continuous Power Peak Power
Efficiency No Load Draw
Low Battery Alarm
PURE SINE 400W CPI400PSW 13.0V DC
115V AC, 60Hz, 3.4A, 400W Pure Sine Wave (PSW) 400 Watt 800 Watt 90% < .6A
10.5V DC
Low Battery Shutdown USB-A Output Port USB-C Output Port AC Output Socket
Protection
Operating Temperature Storage Temperature Power Cable Length: CLA Cable
Length:
Compatible with Cobra Remote LCD (SKU CPIALCDG1)
9.5V DC 5V/3.0A, 9V/1.67A Fast Charge 5V/3.0A, 9V/1.67A Fast Charge 2 GFCI
Protected AC Outputs
Overload, Over Temperature, Short Circuit, Reverse Polarity, Over/Under
Voltage and GFCI
-10°C/14°F – 40°C/104°F -40°C/-40°F – 65°C/149°F 16″ #12 AWG (1) Red, (1) Black
16″
Yes
Specifications subject to change without notice. Please go to www.Cobra.com for more details
18 | P a g e
WARRANTY & TRADEMARK ACKNOWLEDGEMENT
Limited Two-Year Warranty For Products Purchased in the U.S.A. Cobra
Electronics Corporation warrants that its Cobra power inverter, and the
component parts thereof, will be free of defects in workmanship and materials
for a period of two years from the date of first consumer purchase. This
warranty may be enforced by the first consumer purchaser, provided that the
product is utilized within the U.S.A. Cobra will, without charge, repair or
replace, at its option, defective power inverters, products or component parts
upon delivery to the Cobra Factory Service department, accompanied by proof of
the date of first consumer purchase, such as a duplicated copy of a sales
receipt. You must pay any initial shipping charges required to ship the
product for warranty service, but the return charges will be at Cobra’s
expense, if the product is repaired or replaced under warranty. This warranty
gives you specific legal rights, and you may also have other rights which may
vary from state to state.
Exclusions: This limited warranty does not apply: 1. To any product damaged by
accident. 2. In the event of misuse or abuse of the product or as a result of
unauthorized alterations or repairs. 3. If the serial number has been altered,
defaced, or removed. 4. If the owner of the product resides outside the U.S.A.
All implied warranties, including warranties of merchantability and fitness
for a particular purpose are limited in duration to the length of this
warranty. Cobra shall not be liable for any incidental, consequential or other
damages; including, without limitation, to damages resulting from loss of use
or cost of installation. Some states do not allow limitations on how long an
implied warranty lasts and/or do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitations may not apply to
you.
For Products Purchased outside the U.S.A. Please contact your local dealer for
warranty information.
Trademark Acknowledgement Cobra®, Nothing Comes Close to a Cobra®, Pentagon
Protection® and the snake design are registered trademarks of Cobra
Electronics Corporation, USA. Cobra Electronics CorporationTM is a trademark
of Cobra Electronics Corporation, USA.
19 | P a g e
MAINTENANCE & PRODUCT SERVICE
Maintenance Very little maintenance is required to keep the inverter operating
properly. The exterior of the unit should be cleaned periodically with a damp
cloth to prevent accumulation of dust and dirt. At the same time, tighten the
screws on the DC input terminals. Be sure vents and fans are free of dust or
debris. Product Service For any questions about operating or installing this
new Cobra product, please go to www.cobra.com
20 | P a g e
PURE SINE 400W
Power Inverter
Pure Sine Power Inverter with Fast Charge USB
Ideal for travelers and outdoor enthusiasts who want to power devices and
equipment as if they were home. Perfect for specialty and medical equipment.
Count on Cobra for Power Where You Need It.
USB-C Port
Product Features
400 Watts Continuous Power 800 Watts Peak Power
Input/Output LED Indicator
90% Efficiency
(2) GFCI Protected AC Outlets
USB-A Port
(2) AC Outlets
USB-A Fast Charge Port
USB-C Fast Charge Port
LED Indicator
Compatible with Cobra Remote On/Off Controller with Fast Charge USB
Sold Separately
Cooling Fan
Power Button
Remote On/Off Controller Port
Pentagon Protection® Safety Rugged Industrial Design
Negative Battery Terminal
Positive Battery Terminal
*Optional Cobra Remote On/Off Controller with Fast Charge USB to monitor & charge devices from anywhere
inside your vehicle
What’s Included: · Cobra CPI400PSW
Power Inverter · 16″ #12 AWG
Direct-to-Battery Power Cables · 16″ 12 Volt Accessory Cable · Quick Start
Guide
www.cobra.com
Model # CPI400PSW
PURE SINE 400W
Power Inverter
Appliance Wattage Reference Chart
vsetahritcslems.ost vehicles.
General General
Unit Dimensions Unit D5im.5e0n”siHonxs2.87″ W5.5×00″.6H5x”2D.87″ W x 0.65″ D
(139.7mm x 72.9(m13m9.x7m16m.5x1m72m.9) mm x 16.51mm)
uyrccheallrgpehoynoeu,rscmelal rptphhoonnee, ,smtabarletpthaonndeo, thaebrlet
and other e devices. -bright LED. nigleorpetciohnasrg. ing options.
ietsUs.Sol.dA.in the U.S.A.
Unit Weight (Lbs.U) nit W9e.i2ghotz(.L(b2s6.0) .8g.)9.2 oz. (260.8g.)
Individual Box Individ1u0a.l2B5o”xH x 7.25″1W0.2×52″.2H5x”7D.25″ W x 2.25″ D Dimensions Dimen(s2i6o0n.s35mm x 184(2.1650m.3m5mxm57x.158m4.m15)mm x 57.15mm)
Individual Box WeInigdhivtid1u.a2l5Blobxs.W(5ei6g7htg.1) .25 lbs. (567 g.)
Battery
BatterLyithium-cobalt Lithium-cobalt
Battery Capacity Batter2y2C.a2pWahcity 22.2Wh
35 W USB Output USB O2u.t4pAut
2.4A
Start Current Start C1u8r0reAnt
180A
Peak Current Peak C3u6r0reAnt
360A
Model
ModelCPP8000 CPP8000
Master Pack Qty.Maste6r Pack Qty. 6
Master Pack Maste1r 2P.a4c0k” H x15.551″2W.4×0″7.H68x1″5D.55″ W x 7.68″ D
30-60 W Dimensions Dimen(s3i1o5nms m x 395mm(31x51m9m5mxm3)95mm x 195mm)
Master Pack WeiMghatste8r .P5alcbks.W(3e.ig8h5tkg.8).5 lbs. (3.85 kg.)
UPC #
UPC #0 28377 31382 00 28377 31382 0
Master Pack BarcMoadsete2r P0a0ck28B3a7rc7o3de13282004 28377 31382 4
60-90 W without notwicieth.out notice.
40-100 W
35-150 W
90-150 W
German GermanPortuguesPeortuguesSe panish Spanish
200 W
Continuous Power Surge Power Efficiency Rating No-load draw Output Waveform
Input Voltage Range Output Low Voltage Alarm Low Voltage Cut-Off AC
Receptacles Fast Charge USB-A Output Fast Charge USB-C Output Remote-Ready
Output Port Remote Included 12V Vehicle Accessory Cable Includes Direct-to-
Battery Cables Direct-to-Battery Cables Thermal Shut-Down Reverse Polarity
Protection Volt/Watt Meter Warranty Package Type Product Weight Product
dimensions Package dimensions Master pack quantity Master pack dimensions
Master pack weight UPC Master pack barcode
Sold Separately
400W 800W 90% < .6A Pure Sine Wave 10.5 – 15.0V DC 115V AC, 60Hz, 3.4A, 400W 10.5V DC 9.5V DC 2 GFCI Protected AC Outputs 5V/3.0A, 9V/1.67A Fast Charge 5V/3.0A, 9V/1.67A Fast Charge Yes No Yes Yes 16″ #12 AWG Cables Yes Yes 2-Color LED 2 Year Gift Carton 1.98 lbs 8.86″ H x 5.39″ W x 2.83″D 11.02″ W x 9.06″ H x 3.15″ D 6 10.24″ H x 11.42″ W x 18.90″ D 16.04 lbs 0 28377 31556 5 2 00 28377 31556 9
300 W
General Product Launch Info
MSRP/MAP:
$129.95
kaenddetshigensanraekeredgeisstiegrneadre registered
www.cobra.com aCEolercptororantiicosnC, UoSrApo. ration, USA.
CPP8000 5C/P1P58000 5/15
Cobra® and the snake design are registered trademarks of Cobra Electronics
Corporation, USA. Cobra Electronics CorporationTM is a trademark of Cobra
Electronics Corporation, USA. Other trademarks and trade names are those of
their respective owners.
Model # CPI400PSW
Important Power Inverter Safety Information
Before installing and using your Cobra power inverter, please read these
general precautions and warnings. Caution and Warning Statements To make the
most of this inverter, it must be installed and used properly. Please read the
installation and operating instructions carefully before installing and using
it.
CAUTION: Statements specify conditions which could cause damage to the unit or
other equipment.
WARNING: Statements identify conditions that could result in personal injury
or loss of life.
General Precautions 1. Never install the inverter in a boat’s engine
compartment where gas and battery fumes
are present. 2. Do not operate the inverter if it has been dropped or damaged
in any way. 3. Do not open the inverter; it contains no user-serviceable
parts. Attempting to service unit could
cause electrical shock. NOTE: Internal components remain charged after all
power is disconnected. 4. Do not expose the inverter to rain, snow, bilge
water or spray. 5. Do not obstruct the ventilation openings. 6. Do not install
the inverter in zero-clearance compartment.
CAUTION: This inverter should be used in negative ground applications only.
WARNING: Power inverters contain components that tend to produce arcs or
sparks.
To prevent fire or explosion, do not install the inverter in areas or
compartments containing batteries or flammable materials or in locations that
require ignitionprotected equipment. WARNING: To reduce the risk of fire, do
not cover or obstruct the ventilation openings. Do not install inverter in
zero-clearance compartment.
Proposition 65 Warning: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.
Caution: Rechargeable Appliances Certain chargers for small nickel cadmium
batteries can be damaged if connected to a Modified Sine Wave inverter. These
chargers will operate efficiently with a Cobra Pure Sine Wave inverter. Two
particular types of equipment prone to this problem: 1. Small battery-operated
appliances such as flashlights, razors, and night lights that can be plugged
directly into an AC receptacle to recharge. 2. Certain battery chargers for
battery packs used in hand power tools. These chargers have a
WARNING label stating that dangerous voltages are present at the battery
terminals. This problem does not occur with the vast majority of battery
operated equipment. Most use a separate charger or transformer that is plugged
into the AC receptacle and produces a low voltage output. If the label on the
AC adapter or charger states that it produces a low voltage AC or DC output
(less than 30 volts), the inverter will have no problem powering the adapter
safely.
Limited 2-Year Warranty
For Products Purchased in the U.S.A.
Cobra Electronics Corporation warrants that its Cobra power inverter, and the
component parts thereof, will be free of defects in workmanship and materials
for a period of two years from the date of first consumer purchase. This
warranty may be enforced by the first consumer purchaser, provided that the
product is utilized within the U.S.A.
Cobra will, without charge, repair or replace, at its option, defective power
inverters, products or component parts upon delivery to the Cobra Factory
Service department, accompanied by proof of the date of first consumer
purchase, such as a duplicated copy of a sales receipt.
You must pay any initial shipping charges required to ship the product for
warranty service, but the return charges will be at Cobra’s expense, if the
product is repaired or replaced under warranty. This warranty gives you
specific legal rights, and you may also have other rights which may vary from
state to state.
Exclusions: This limited warranty does not apply:
1. To any product damaged by accident.
2. In the event of misuse or abuse of the product or as a result of
unauthorized alterations or repairs.
3. If the serial number has been altered, defaced, or removed.
4. If the owner of the product resides outside the U.S.A.
All implied warranties, including warranties of merchantability and fitness
for a particular purpose are limited in duration to the length of this
warranty. Cobra shall not be liable for any incidental, consequential or other
damages; including, without limitation, to damages resulting from loss of use
or cost of installation.
Some states do not allow limitations on how long an implied warranty lasts
and/or do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations may not apply to you.
For Products Purchased Outside the U.S.A.
Please contact your local dealer for warranty information.
lnformaci6n lmportante de Seguridad del lnversor de Potencia
Lea las siguientes precauciones y advertencias antes de instalar y usar su
lnversor de Potencia Cobra.
Declaraciones de Precauci6n y Advertencias lnstale y utilice adecuadamente su
inversor para aprovecharlo al maxima. Lea cuidadosamente las instrucciones de
instalaci6n y operaci6n antes de instalar y usar su inversor.
PRECAUCION: Las declaraciones a continuaci6n especifican las condiciones que
pueden provocar dafios a la unidad u otro equipo.
ADVERTENCIA: Las declaraciones a continuaci6n especifican las condiciones que
pueden resultar en lesion personal o perdida de la vida.
Precauciones generales:
1. Nunca instale el inversor en el compartimiento del motor de un barco donde
haya vapores de gasolina y de la bateria.
2. No opere el inversor si se ha cafdo o dafiado de cualquier manera.
3. No abra el inversor, no contiene piezas a las que pueda dar servicio el
usuario. Si intenta abrir la unidad para darle servicio puede recibir una
descarga electrica.
NOTA: Los componentes internos permanecen cargados despues de desconectar la
fuente de alimentaci6n.
4. No exponga el inversor a la lluvia, nieve, agua de sentina, o aspersion.
5. No obstruya las aberturas de ventilaci6n.
6. No instale el inversor en compartimientos sin espacio libre.
PRECAUCION: El inversor se debe utilizar para aplicaciones de tierra negativa
solamente.
ADVERTENCIA: Los inversores de potencia contienen componentes que pueden
generar arcos o chispas. Para evitar incendios o explosiones, no instale el
inversor en areas o compartimientos que contenga baterias o materiales
inflamables, ni en lugares que requieran el uso de equipo protegido contra
incendios.
ADVERTENCIA: Para reducir el riesgo de incendio, no cubra ni obstruya las
aberturas de ventilaci6n. No instale el inversor en compartimientos sin
espacio libre.
Advertencia de la Propuesta 65: Cancer y dafio reproductive –
www.P65Warnings.ca.gov.
Precauci6n: Electrodomesticos Recargables Ciertos cargadores de baterias
pequefias de nfquel y cadmio se pueden dafiar si se conectan a un inversor de
Onda Sinusoidal Modificada. Dichos cargadores funcionan eficazmente con un
lnversor Cobra Pure Sine Wave. Dos tipos especfficos de equipo son propensos a
dicho problema: 1. Dispositivos pequefios que funcionan con baterias, tales
como linternas, afeitadoras, y luces nocturnas
que se pueden conectar directamente a un tomacorrientes de corriente alterna
para su recarga. 2. Ciertos cargadores de baterias que se utilizan con
herramientas electricas. Dichos cargadores cuentan
con una etiqueta de ADVERTENCIA que indica que las terminales de las baterias
tienen voltajes peligrosos presentes.
Este problema no sucede en la gran mayorfa del equipo operado por baterias. La
mayoria utiliza un cargador o transformador separado que se conecta al
tomacorriente de corriente alterna y genera una salida de voltaje bajo. Si la
etiqueta en el adaptador o cargador de corriente alterna indica que genera una
salida de voltaje bajo de corriente alterna o directa (menos de 30 voltios),
el inversor no tendra problema para alimentar el adaptador de manera segura.
Garantfa limitada de 2 anos
Para productos adquiridos en EE. UU. Cobra Electronics Corporation garantiza
que el lnversor de Potencia Cobra, y los componentes del mismo, estaran libres
de defectos de mano de obra y materiales por un periodo de dos anos a partir
de la fecha de compra del primer consumidor. La presente garantfa podria
aplicarse al primer comprador consumidor, siempre y cuando el producto se
utilice en EE. UU.
Cobra reparara o reemplazara, sin cargo y a su propio criteria, inversores de
potencia defectuosos o refacciones al recibirlas en el departamento de
Servicio de fabrica de Cobra, acompanados de comprobante de compra del primer
comprador de consume, tal como una copia del recibo de compra.
Usted debera pagar los cargos iniciales de envfo necesarios para embarcar el
producto para su servicio bajo garantfa, sin embargo los cargos de devoluci6n
seran a cargo de Cobra, si el producto se repara o reemplaza bajo garantfa. La
presente garantfa le proporciona derechos especfficos legales, y tambien
podrfa tener otros derechos, los cuales varfan en cada estado.
Exclusiones: La presente garantfa limitada no se aplica a lo siguiente:
1. A ningun producto danado por accidente.
2. En caso de uso indebido o abuso del producto como resultado de
alteraciones o reparaciones no autorizadas.
3. Si el numero de serie ha sido alterado, desfigurado o retirado.
4. Si el propietario del producto reside fuera de EE. UU.
Todas las garantfas implicitas, incluyendo garantfas de comerciabilidad e
idoneidad para un objetivo en particular son limitadas a la duraci6n de la
presente garantfa. Cobra no se hara responsable de danos incidentales,
consecuenciales, u otros; incluyendo, sin limitaci6n, a danos generados por
perdida de uso o costo de instalaci6n.
Algunos estados no permiten limitaciones en cuanto a la duraci6n de la
garantfa, y/o no permiten la exclusion o limitaci6n de danos incidentales o
consecuenciales, asi que las limitaciones anteriores podrfan no aplicar a
usted.
Para productos adquiridos fuera de EE. UU.
Comunfquese con su distribuidor local para informaci6n de garantfas.
Register your new Cobra product
www.cobra.com/register
Register your product today to get:
Helpful Product Tips
Exclusive Offers
Expert Advice
!,cobra®
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>