XTREME Slim OSDP Reader User Manual

June 1, 2024
Xtreme

XTREME Slim OSDP Reader

Introduction

It is a waterproof OSbr reader, and also with Wiegand output, can read 125KHz EM card, hiD card a 13.56MHZ Mitare cards at the same time.

Features
  1. Waterproof, conforms to IP66
  2. OSDP+ Wiegand, AES128 encryption
  3. Card Type: 125KHz HID, EM & 13.56MHz Mifare
  4. Programmable Wiegand output (by remote control included in the box)
  5. EM card: Wiegand 26~44 bits output (default: 26bits)
  6. Mifare card: Wiegand 26~44, 56, 58bits output (default: 34bits)
  7. HID card: Wiegand 26-37 bits output
Specifications

XTREME-Slim-OSDP-Reader-Fig- \(1\)

Installation

  • Drill 2 holes (A, C) on the wall for the screws and one hole (B) for the cable
  • Knock the rubber bungs to the holes (A, C)
  • Fix the back cover on the wall with 2 screws
  • Thread the cable though the cable hole (B)
  • Attach the unit to the back cover

XTREME-Slim-OSDP-Reader-Fig- \(2\)

Wiring

XTREME-Slim-OSDP-Reader-Fig- \(3\)

Connection Diagram

Connect with OSDP Controller

Connect with Wiegand Controller

Programming

Note:
Use the remote control included in the box to do programming

Set Master Code (6 digits)
The Master Code is used to prevent unauthorized access to the system, we highly recommend immediately updating it and recording the New Master Code.

XTREME-Slim-OSDP-Reader-Fig- \(6\)

Set Wiegand Fonnat for EM Cards

XTREME-Slim-OSDP-Reader-Fig- \(7\)

Set Wiegand Fonnat for HID Cards

XTREME-Slim-OSDP-Reader-Fig- \(8\)

Set Wiegand Fonnat for Ml FARE Cards

XTREME-Slim-OSDP-Reader-Fig- \(9\)

Baud Rate Settings (Factory default: 9600)

XTREME-Slim-OSDP-Reader-Fig- \(10\)

Note:
The baud rate of all readers under the same controller should be set to the same as the controller’s baud rate, otherwise the connection will fail.

OSOP Address Settings (Factory default: 0)

XTREME-Slim-OSDP-Reader-Fig- \(11\)

Note:
The addresses of all readers under the same controller should be set to be different, otherwise, the two readers will conflict

Reset to Factory Default (two methods)

Method 1

XTREME-Slim-OSDP-Reader-Fig- \(12\)

Method 2 (This way is suitable for users who forget the master code):
Power off, connect the Yellow wire and GND wire, then power on, and wait for 5 seconds, there will be a long beep, then reset to factory default successfully, then disconnect the Yellow wire and GND wire.

Indicator light status

XTREME-Slim-OSDP-Reader-Fig- \(13\)

Packing List

XTREME-Slim-OSDP-Reader-Fig- \(14\)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals