BOSCH GAS 55 M AFC Professional Wet and Dry Vacuum Cleaner Instruction Manual

June 1, 2024
Bosch

BOSCH GAS 55 M AFC Professional Wet and Dry Vacuum Cleaner

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-PRODUCT-
IMAGE

Specifications :

  • Brand : Bosch Power Tools
  • Model : GAS 55 M AFC Professional
  • Power : 2200 W
  • Voltage : 230 V
  • Max. Suction Power : 266.4 l/s
  • Dust Class : M
  • Weight : 16.2 kg

Product Information

The Bosch GAS 55 M AFC Professional is a powerful vacuum cleaner designed for heavy-duty cleaning tasks. It features Automatic Filter Cleaning (AFC) for efficient operation and maintenance.

Key Components :

  • Suction Hose Holder
  • Airflow Regulator
  • Operating Mode Selector

Product Usage Instructions

Warnings:

  • Always supervise children to prevent them from playing with the vacuum cleaner.
  • Avoid vacuuming asbestos-containing materials as asbestos is carcinogenic.
  • Only use the vacuum cleaner for its intended purposes as described in the user manual.
  • Immediately turn off the vacuum cleaner if operating in a wet environment and consider using a Residual Current Device (RCD) for electrical safety.
  • Have the vacuum cleaner serviced or repaired only by qualified personnel using original spare parts to maintain safety standards.

Technical Data:

  • Max. Power Consumption: 2200 W
  • Max. Suction Power: 266.4 l/s
  • Dust Class: M
  • Weight: 16.2 kg

Product Assembly:
To assemble the vacuum cleaner, follow the instructions provided in the user manual. Start by attaching the suction hose as shown in Figure B.

FAQ :

  • Q: Can I use this vacuum cleaner to clean wet surfaces?
    A: It is recommended to avoid using the vacuum cleaner on wet surfaces. If unavoidable, consider using a Residual Current Device (RCD) for safety.

  • Q: How often should I clean the filter?
    A: The Automatic Filter Cleaning (AFC) feature helps maintain filter efficiency. However, it is advisable to check and clean the filter regularly according to usage frequency.

  • Q: Can I use attachments with different hose diameters?
    A: The vacuum cleaner supports different hose diameters (15 mm, 22 mm, 35 mm) as indicated by symbols. Ensure compatibility before using attachments.

Robert Bosch Power Tools GmbH

Safety information for vacuum cleaners

Read all the safety information and instructions. Failure to observe the safety information and follow instructions may result in electric shock. fire and/or serious inquiry.

  • Save all warnings and instructions for future reference.
  • This vacuum cleaner is not intended for use by children or persons with physical, sensory or mental impairments.
  • It should not be used by persons who have insufficient experience and knowledge. Otherwise, there is a risk of operating errors and injuries.
  • Supervise children. This will ensure that children do not play with the vacuum cleaner.
  • Comply with all safety provisions for the substances being extracted.

WARNING
Never vacuum material that contains asbestos. Asbestos is a carcinogenic substance.

  •   WARNING
  • Only use the vacuum cleaner if you have been adequately informed about the use of the equipment, the substances to be vacuumed and how to dispose of these safely. Thorough instruction on how to use the equipment prevents accidental misuse and injuries.
  • WARNING The vacuum cleaner is suitable for vacuuming dry substances, and can also be used to vacuum liquids when taking appropriate measures. The penetration of liquids increases the risk of an electric shock.
  • Do not use the vacuum cleaner to vacuum combustible or explosive liquids, such as petrol, oil, alcohol or solvents. Do not vacuum hot, burning or explosive dust. Do not operate the vacuum cleaner in areas subject to explosion hazards. Dust, vapours and liquids can ignite or explode.
  • WARNING Only use the socket for the purpose stipulated in the operating manual.
  • WARNING If you notice a foam or water leak,  switch off the vacuum cleaner immediately and empty the container. Otherwise, the vacuum cleaner can become damaged.
  • NOTE: The vacuum cleaner must only be stored in-doors.
  • NOTE: Clean the liquid fill level sensors regularly and check whether they are damaged. Otherwise, the equipment may not function properly.
  • If operating the vacuum cleaner in a damp location is unavoidable, use a residual current device (RCD). Use of an RCD reduces the risk of electric shock.
  • Always check the vacuum cleaner, cable and plug before use. Do not use the vacuum cleaner if you discover any damage. Do not open the vacuum cleaner yourself. It should be repaired exclusively by a qualified professional using only genuine spare parts. Damaged vacuum cleaners, cables and plugs increase the risk of electric shock.
  • Do not crush the cable or run the device over it. Do not pull on the power cable to pull the plug out of the socket or to move the vacuum cleaner. Damaged cables increase the risk of an electric shock.
  • Pull the plug out of the socket before cleaning or performing maintenance on the vacuum cleaner, making tool adjustments, changing accessories or putting away the vacuum cleaner. This safety measure prevents the vacuum cleaner from being started accidentally.
  • Ensure that the workplace is well ventilated.
  • The vacuum cleaner should be repaired exclusively by a qualified professional using only genuine spare parts. This will ensure that the safety of the vacuum cleaner is maintained.
  • If the dust extractor is being used in areas containing hazardous substances, then vacuum, wipe or seal the outside of the dust extractor before taking it out of the hazardous area.
  • All parts of the dust extractor are deemed contaminated and you must ensure appropriate measures are taken to prevent the hazardous substances from spreading.
  • WARNING The dust extractor contains dust  particles that pose a risk to health. Emptying and maintenance procedures, including the disposal of dust containers, should only be carried out by professionals. Suitable protective equipment is required. Do not operate the vacuum cleaner unless the complete filter system is correctly inserted. Otherwise, you are putting your health at risk.
  • Before using the equipment for the first time, check that the vacuum hose is in perfect condition. Leave the vacuum hose fitted to the vacuum cleaner while doing this so that no dust escapes accidentally. Otherwise, you may end up inhaling dust particles.
  • Do not sit on the vacuum cleaner. You can damage the vacuum cleaner this way.
  • Take care when using the power cable and the vacuum hose. Improper use of these can put other people at risk.
  • Do not clean the vacuum cleaner by spraying a jet of water directly at it. Water entering the top of the vacuum cleaner will increase the risk of electric shock.
  • Connect the dust extractor to a properly earthed power supply system. The plug socket and extension cable must have a fully functioning protective conductor.

Products sold in GB only :

  • Your product is fitted with an BS 1363/A approved electric plug with internal fuse (ASTA approved to BS 1362).
  • If the plug is not suitable for your socket outlets, it should be cut off and an appropriate plug fitted in its place by an authorised customer service agent. The replacement plug  should have the same fuse rating as the original plug.
  • The severed plug must be disposed of to avoid a possible shock hazard and should never be inserted into a mains socket elsewhere.

Symbols

The following symbols may provide you with important information pertaining to the use of your dust extractor. Please take note of these symbols and their meaning. Knowing what these symbols mean will help you to use your extractor more effectively and more safely.

Symbols and their meaning

  • WARNING! Read all the safety and general instructions. Failure to observe the safety and general instructions may result in electric shock, fire and/or serious injury.
  • Dust extractor from dust class M in accordance with IEC/EN 60335-2-69 for the dry extraction of harmful dusts with an exposure limit of ≥ 0.1 mg/m³
  • WARNING! The dust extractor contains dust particles that pose a risk to health. Emptying and maintenance procedures, including the disposal of dust containers, should only be carried out by professionals. Suitable protective equipment is required. Do not operate the dust extractor unless the complete filter system is correctly inserted. Otherwise, you are putting your health at risk.

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(19\)

  • You can attach an L-Boxx to the top part of the dust extractor for transporting the extractor and to provide space saving storage for extractor accessories and/or the power tool.

  • Do not use the dust extractor with an L-Boxx attached. This will raise the dust extractor’s centre of gravity. The extractor may tip over. There is a risk of injury and damage if you do this.

  • Only attach a maximum of one L-Boxx.

  • The weight of the L-BOXX along with its contents must not exceed 15 kg.

  • Do not hang the dust extractor on a crane hook, e.g. in order to transport it. The dust extractor is not suitable for moving with a crane. There is a risk of in-jury and damage if you do this.

  • Do not sit or stand on the dust extractor. The dust extractor may tip over and become damaged if you do this. This poses a risk of injury.BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(23\)

  • Automatic start/stop

    • Extracting dust that accumulates from working power tools.
    • The dust extractor switches on automatically and off again with a time delay.
  • Switching Off

  • Extraction Extracting dust deposits

Product Description and Specifications

Please observe the illustrations at the beginning of this operating manual.

Intended Use

  • The dust extractor is intended for collecting, vacuuming, conveying and separating wood chips as well as non-flammable dry dusts, non-flammable liquids and water air mixtures.
  • The dust extraction capability of the dust extractor has been tested and corresponds to dust class M. It is suitable for the increased demands in professional use, e.g. in trade, industry and workshops.
  • Dust extractors from dust class M in accordance with IEC/EN 60335-2-69 may only be used to vacuum and extract harmful dust with an exposure limit of ≥ 0.1 mg/m3.
  • Only use the dust extractor if you can fully evaluate all functions and carry them out without restrictions, or if you have received corresponding instructions.

Product features

The numbering of the product features refers to the representation of the vacuum cleaner on the graphic pages.

  1. Container
  2. Sealing plug for extraction connection
  3. Hose adapter
  4. Holder for vacuum hose
  5. Socket for power tool
  6. Volume flow rate controller
  7. Mode selector switch
  8. Suction power regulator
  9. AFC button
  10.  Carrying handle
  11. L-Boxx holder
  12. Guide handle
  13. Top part of dust extractor
  14. Cable holder
  15.  Catch for top part of dust extractor
  16. Wheel
  17.  Castor brake
  18. Castor
  19.  Castor frame
  20. Closing flap for filter cover
  21. Holder for crevice nozzle/curved nozzle
  22. Holder for suction tubes
  23.  Dump hose
  24. Holder for floor nozzle
  25.  Dust extraction adapter
  26.  False air intake
  27. Vacuum hose
  28. Curved nozzle
  29.  Disposal bag
  30.  Flat-pleated filter (PES)
  31.  Crevice nozzle
  32. Rubber lip
  33. Brush inserts
  34. Floor nozzle
  35. Suction tube
  36. Adapter for vacuum hose holder
  37. Snap fastener
  38. Control LED
  39. Filter cover
  40. Fill level sensors

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(1\) BOSCH-GAS-55-M-AFC-
Professional-Wet-and-Dry-Vacuum-Cleaner- \(3\)

Technical data

  • Measured using a vacuum hose 3 m long and 35 mm in diameter
  • The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
  • Values can vary depending on the product, scope of application and environmental conditions. To find out more, visit www.bosch-professional.com/wac.

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(36\)

  • Permitted connected load of the connected power tool.
  • These values can differ for other country specific models. Please take note of the information on the socket of the dust extractor.

Noise/Vibration Information

  • Noise emission values determined according to
  • EN 60335-2-69.
  • Typically the A-weighted sound pressure level of the dust extractor is 70 dB(A). Uncertainty K = 3 dB. The noise level when working can exceed 80 dB(A).
  • Wear hearing protection
  • Total vibration values ah (triax vector sum) and uncertainty K determined according to EN 60335-2-69: ah<2.5 m/s2,
  • K = 1.5 m/s2.

Assembly

  • Pull the plug out of the socket before cleaning or performing maintenance on the vacuum cleaner, making tool adjustments, changing accessories or putting away the vacuum cleaner. This safety measure prevents the vacuum cleaner from being started accidentally.

  • Fitting the holder for the vacuum hose
    (see figure A)

  • Slide the holder (4) for the vacuum hose firmly into the corresponding adapters (36) from above until they click into place.

  • Fitting the vacuum hose (see figure B)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(5\)

  • Pull the sealing plug (2) out of the hose adapter (3). Attach the vacuum hose (27) to the hose adapter (3) and turn it clockwise as far as it will go.

  • Always seal the extraction connection with the sealing plug whenever you remove the vacuum hose. This prevents dust from escaping.

  • Note: The friction generated by the dust in the vacuum hose and accessory during extraction causes an electrostatic charge that the user may experience as static discharge (depending on environmental factors and their physiological state).

  • Bosch generally recommends using an anti-static vacuum hose (accessory) to vacuum up fine dust and dry materials.

  • Fitting the vacuuming accessories (see figure C)

  • The vacuum hose (27) is equipped with a clip system which can be used to connect vacuuming accessories (dust extraction adapter (25), curved nozzle (28)).

  • Fitting the nozzles and tubes

    • Push the curved nozzle (28) onto the vacuum hose (27) until you hear both snap fasteners (37) on the vacuum hose engage.
    • Then attach the required extraction accessory (floor nozzle, crevice nozzle, suction tube, etc.) firmly to the curved nozzle (28).
    • To remove the accessory, press the snap fasteners (37) inwards and pull apart the components.

Fitting the dust extraction adapter

  • Push the dust extraction adapter (25) onto the vacuum hose (27) until you hear both snap fasteners (37) on the vacuum hose engage.

  • To remove the adapter, press the snap fasteners (37) in-wards and pull apart the components.

  • Inserting/removing the disposal bag or dust bag (dry extraction) (see figure D)

  • A disposal bag (29) or dust bag must be used for the dry extraction of dust class M materials.

  • Insofar as materials with or without an exposure limit of  ≥ 1 mg/m3 (dust class L materials) are extracted, these can be sucked straight into the container.

  • Note: If using a paper filter bag, you must make sure that automatic filter cleaning (AFC) is switched off; you should also do the same if using a fleece filter bag (see ” Automatic filter cleaning (see figure I)”, page 24).

  • WARNING The dust extractor contains dust
    particles that pose a risk to health. Emptying and maintenance procedures, including the disposal of dust containers, should only be carried out by professionals. Suitable protective equipment is required. Do not operate the vacuum cleaner unless the complete filter system is correctly inserted. Otherwise, you are putting your health at risk.

  • Inserting the disposal bag

    • Open the catches (15) and remove the top part of the vacuum cleaner (13).
    • Insert the disposal bag (29) into the container (1) with the inlet facing forwards.
    • Pull the inlet over the connection flange and all the way into the recess of the connection flange.
    • Make sure that the disposal bag (29) touches all the in-side walls of the container (1).
    • Fold the rest of the disposal bag (29) over the edge of the container (1).
    • Put the top part of the vacuum cleaner (13) on and close the catches (15).
  • Removing and sealing the disposal bag

    • Open the catches (15) and remove the top part of the vacuum cleaner (13).
    • Pull the full disposal bag (29) backwards out of the connection flange.
    • Carefully take the disposal bag (29) out of the container (1) without damaging it.
    • When doing so, make sure that the disposal bag does not scrape against the connection flange or other sharp objects.
    • Remove the adhesive strip cover and tape up the disposal bag.
      Then tie up the disposal bag (29) below the inlet using the adhesive strip cover that has been removed.
  • Changing/inserting the dust bag (accessory)

    •  Open the catches (15) and remove the top part of the vacuum cleaner (13).
    • Pull the full dust bag backwards out of the connection flange. Close the opening in the dust bag by turning down the top. Take the closed dust bag out of the container (1).
    • Place the new dust bag over the vacuum cleaner’s connection flange. Make sure that the entire length of the dust bag touches the inside wall of the container (1).
    • Put the top part of the vacuum cleaner (13) on and close the catches (15).
    • Fitting the rubber lip (wet extraction) (see figure E)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(8\)
      Note: The requirements for the degree of penetration (dust class M) have only been verified for dry extraction.
  • Use a suitable tool to lift the brush inserts (33) out of the floor nozzle (34).

  • Place the rubber lips (32) in the floor nozzle (34). Note: The textured side of the rubber lips must be facing outwards.

  • Attaching the L-Boxx (see figure F)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(9\)

  • You can attach an L-Boxx to the top part of the dust extractor for transporting the extractor and to provide space-saving storage for extractor accessories and/or the power tool.

  • Click the L-Boxx onto the adapters (11).

  •  Do not use the dust extractor with an L-Boxx attached. This will raise the dust extractor’s centre of gravity. The extractor may tip over. There is a risk of injury and damage if you do this.

  • Do not carry the dust extractor by the carrying handle of the attached L-Boxx. The dust extractor is too heavy for the carrying handle of the L-Boxx. There is a risk of injury and damage if you do this.

Operation

  • Pull the plug out of the socket before cleaning or performing maintenance on the vacuum cleaner, making tool adjustments, changing accessories or putting away the vacuum cleaner. This safety measure prevents the vacuum cleaner from being started accidentally.

Start-up

  • Pay attention to the mains voltage. The voltage of the power source must correspond with the data on the type plate of the vacuum cleaner.
  • Make sure you inform yourself about the applicable regulations/laws on how to handle harmful types of dust in your country.
  • The dust extractor may be used for vacuuming and extracting the following materials:
    • Dusts with an exposure limit of ≥ 0.1 mg/m3
  • Products that are only sold in AUS and NZ: Use a residual current device (RCD) with a nominal residual current of 30 mA or less.
  • The dust extractor must categorically not be used in potentially explosive areas.
  • To ensure optimum suction power, you must always fully unwind the vacuum hose (27) from the top part of the dust extractor (13).
  • Dry vacuuming
  • Vacuuming up dust deposits
    • Adjust the volume flow controller (6) to suit the hose diameter used.
    • To switch on the dust extractor, set the mode selector switch (7) to the “extraction” symbol.
    • To switch off the dust extractor, set the mode selector switch (7) to the “switch off” symbol.
  • The dust extractor is fitted with airflow monitoring. In the “vacuuming” operating mode, the volume flow monitoring is fixed to a value of 20 m/s, irrespective of the setting of the volume flow controller (6).
  • If the value falls below this, e.g. due to accumulated dirt in the vacuum hose, a full dust bag or a clogged flat pleated filter, an audible alarm signal will sound. In this case, switch off the dust extractor and check it as described in the “Rectifying faults” section.
  • Extracting dust that accumulates from working power tools (see figure G)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(10\)
  • There must be a sufficient air exchange rate in the room when the exhaust air comes back into the room. Be aware of the corresponding national regulations.
  • The dust extractor has a plug socket with a protective earth contact (5) that can be used to connect an external power tool. Observe the maximum permitted connected load of the connected power tool.
  • In order for sufficient dust transport to be ensured at the extraction point, the volume flow must not fall below the minimum specified for the connected power tool.

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(37\)

  • Adjust the volume flow controller (6) to suit the hose diameter used.

  • Fit the dust extraction adapter (25).

  • Insert the dust extraction adapter (25) into the extraction outlet of the power tool.

  • Note: When working with power tools that have a low air feed into the vacuum hose (e.g. jigsaws, sanders, etc.), the English | 23 false air intake (26) of the dust extraction adapter (25) must be opened. This will ensure that the automatic filter cleaning function works correctly.

  • To do this, turn the ring above the false air intake (26) until the opening is at its maximum size.

  • To activate the automatic start/stop function of the dust extractor, set the mode selector switch (7) to the “automatic start/stop” symbol.

  • In this operating mode, the volume flow is electronically monitored according to the setting of the volume flow controller (6). Having the correct setting selected ensures sufficient dust transport.

  • To start the dust extractor, switch on the power tool connected to the plug socket (5). The dust extractor will start automatically.

  • To stop dust extraction, switch the power tool off. The automatic start/stop run on function will run for up to 15 seconds longer in order to extract the remaining dust from the vacuum hose.

  • To switch off the dust extractor, set the mode selector switch (7) to the “switch off” symbol.

  • If the acoustic warning signal sounds, the dust extractor must be checked as described in the “Rectifying faults” section.

  • Wet extraction (see figure H)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(11\)

  • Do not use the vacuum cleaner to vacuum combustible or explosive liquids, such as petrol, oil, alcohol or solvents. Do not vacuum hot, burning or explosive dust. Do not operate the vacuum cleaner in areas subject to explosion hazards. Dust, vapours and liquids can ignite or explode.

  • The vacuum cleaner must not be used as a water pump. The vacuum cleaner is designed for vacuuming air and vacuuming water mixtures.

  • Note: The requirements for the degree of penetration (dust class M) have only been verified for dry extraction.
    Steps to Take before Wet Vacuuming

  • Remove the disposal bag (29) or dust bag if necessary. Note: Use a wet filter bag (accessory), which separates liquid from solids, to make disposal easier when vacuuming water-solid mixtures.

  • Fit the rubber lip (32) in the floor nozzle (34) (see “Fitting the rubber lip (wet extraction) (see figure E)”, page 22).

  •  Switch off the automatic filter cleaning (AFC) (see ” Automatic filter cleaning (see figure I)”, page 24).

Vacuuming up liquids

  • To switch on the dust extractor, set the mode selector switch (7) to the “extraction” symbol.

  • The dust extractor is equipped with fill level sensors (40). The dust extractor shuts down if the maximum fill level has

  • been reached. Set the mode selector switch (7) to the
    “switch off” symbol.

  • Note: When extracting non-conductive liquids (e.g. drilling emulsion, oils and fats), the dust extractor will not switch off when the container is full. The fill level must be constantly monitored and the container emptied in good time.

If the acoustic warning signal sounds during wet extraction, the operating reliability of the dust extractor is not affected. No measures to rectify the fault are necessary.

  • To switch off the dust extractor, set the mode selector switch (7) to the “switch off” symbol.

  • Pull the dump hose (23) from its holder and drain off the waste water through the dump hose.

  • To transport the dust extractor, screw the sealing plug (2) onto the hose adapter (3).

  • Empty the container (1).
    To prevent mould growth after wet extraction:

    • Remove the flat-pleated filter (30) and leave this to dry thoroughly.
    • Remove the top part of the dust extractor (13), open the filter cover (39) and leave both elements to dry thoroughly.
  • Automatic filter cleaning (see figure I)BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(12\)

  • When automatic filter cleaning (AFC) is active, the flat-pleated filter (30) is cleaned every 15 seconds using blasts of air (pulsating noise).

  • The filter cleaning function should be used regularly, and at the very latest when the suction power is no longer sufficient.

  • Regular use of the filter cleaning function will increase the service life of the filter.

  • In order to achieve an optimum filter service life, deactivate the automatic filter cleaning function only in exceptional cases, e.g. when vacuuming pure liquids or using a paper filter bag.

  • A flat-pleated filter with surface dirt is still fully functional. It is not necessary to clean the flat-pleated filter manually by shaking or blowing it out; this may even damage the filter.

  • Note: The automatic filter cleaning function is switched on by default when the dust extractor leaves the factory.

  • It is only possible to switch the automatic filter function on or off when the tool is switched on.

    • Deactivating AFC
    • Press the AFC button (9).
    • The control LED (38) will go out.
    • Activating AFC
    • Press the AFC button (9).
    • The control LED (38) will light up green.

Maintenance and service

  • Maintenance and Cleaning

  • Pull the plug out of the socket before cleaning or per-forming maintenance on the vacuum cleaner, making tool adjustments, changing accessories or putting away the vacuum cleaner. This safety measure prevents the vacuum cleaner from being started accidentally.

  • To ensure safe and efficient operation, always keep the dust extractor and the ventilation slots clean.

  • Wear a dust mask when servicing and cleaning the vacuum cleaner.

  • In order to avoid safety hazards, if the power supply cord needs to be replaced, this must be done by Bosch or by an after-sales service centre that is authorised to repair Bosch power tools.

  • For the user to carry out maintenance, the dust extractor needs to be disassembled, cleaned and maintained as far as this is possible without endangering maintenance personnel or  other persons. Before disassembly, the dust extractor should be cleaned to prevent any potential hazards. The room/enclosure in which the dust extractor is disassembled should be well ventilated. Wear personal protective equipment while carrying out maintenance. After completing maintenance, the maintenance area should be cleaned. An inspection regarding the dust extraction capability must be carried out at least once a year by the manufacturer or someone who has been trained, e.g. to check for filter damage, that the dust extractor is tight and that the control unit is functioning correctly.

  • Class M dust extractors that have been in dirty environments should have their exteriors, as well as all their components, cleaned. Suction, wipe down and seal the outside of the dust extractor before removing it from the danger zone. When performing maintenance and repair work, all dirty parts that cannot be cleaned satisfactorily must be disposed of. Such parts must be disposed of in impermeable bags in accordance with the valid provisions for disposing of such waste.

  • Removing/changing the flat-pleated filter (see figures J1−J2) BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner- \(14\)

  • Suction power is dependent on the condition of the filter. Therefore, the filter should be cleaned regularly.

  • If the flat-pleated filter (30) becomes damaged, replace it immediately.

  • Pull on the closing flap (20) and open the filter cover (39).

  • Hold the flat-pleated filter (30) by the supports and take it out from above.

  • Use a damp cloth to remove any dust and dirt that accrues around the closing edge of the filter cover (39) when removing the flat-pleated filter (30).
    PES and PTFE flat-pleated filters can be rinsed out under running water.

  • Insert the cleaned (or a new) flat-pleated filter (30), ensuring that it is positioned correctly and securely. Close the filter cover (39) again (must audibly click into place).

Cleaning the container

  •  Wipe the container (1) from time to time using a non-abrasive off-the-shelf cleaning product and leave it to dry.

  • Cleaning the fill level sensors (see figure K)
    Make sure that the fill level sensors are cleaned (40) occasionally.

  • Open the catches (15) and remove the top part of the vacuum cleaner (13).

  • Clean the fill level sensors (40) using a soft cloth.

  • Put the top part of the vacuum cleaner (13) on and close the catches (15).

Storage and transport

  • Storage (see figure L)
  • Wrap the power cable around the cable holder (14).
  • Insert the accessory into the holders provided for it: Suction tubes (35) into the holders (22), crevice nozzle (31) into the holder (21), floor nozzle (34) into the holder
    (24).

Rectifying faults

  • If a fault (e.g. a filter damage) occurs, the vacuum cleaner must be switched off immediately. The fault must be repaired before resuming operation.

  • Open the elastic bands of the vacuum hose holder (4) and wrap the vacuum hose (27) around the top part of the dust extractor in the holder (4).
    Hook the elastic bands back in.

  • Click the L-Boxx onto the holders (11).

  • Store the dust extractor in a dry room and secure it so that it cannot be used by unauthorised persons.

  • Put the castor brake (17) down to hold the castors (18) in place.

Transport (see figure M)

  • To transport the dust extractor, screw the sealing plug (2) onto the hose adapter (3).
  • Only ever carry the vacuum cleaner by the carrying handle (10).
  • Use the guide handle (12) to push the dust extractor or to pull it up steps.

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(38\) BOSCH-GAS-55-M-AFC-
Professional-Wet-and-Dry-Vacuum-Cleaner- \(39\) BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(40\)

Accessories

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(41\)

  • After-Sales Service and Application Service
  • Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. You can find explosion drawings and information on spare parts at: www.boschpt.com
  • The Bosch product use advice team will be happy to help you with any questions about our products and their accessories.
  • In all correspondence and spare parts orders, please always include the 10‑digit article number given on the nameplate of the product.
  • Great Britain
  • Robert Bosch Ltd. (B.S.C.)
  • P.O. Box 98
  • Broadwater Park
  • North Orbital Road
  • Denham Uxbridge
  • UB 9 5HJ
  • At www.boschpt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair. Tel. Service: (0344) 7360109
  • E-Mail: boschservicecentre@bosch.com
  • You can find further service addresses at:
    www.bosch-pt.com/serviceaddresses

Disposal

  • The vacuum cleaner, its accessories and packaging should be recycled in an environmentally friendly manner.
  • Do not dispose of the vacuum cleaner along with household waste.
  • Only for EU countries:
  • According to the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment and its implementation into national law, vacuum cleaners that are no longer usable must be collected separately and disposed of in an environ-mentally friendly manner.
  • If disposed incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.
  • Only for United Kingdom:
  • According to The Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended), products that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

TOOLS

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(42\)BOSCH-GAS-55-M-AFC-
Professional-Wet-and-Dry-Vacuum-Cleaner- \(43\)

EU Declaration of Conformity

  • Wet/dry dust extractor
  • Article number
  • We declare under our sole responsibility that the stated products comply with all applicable provisions of the directives and regulations listed below and are in conformity with the following standards. Technical file at: *

BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(44\)

Declaration of Conformity

  • Wet/dry dust extractor Article number
  • GAS 55 M AFC 3 601 JC3 360
  • We declare under our sole responsibility that the stated products comply with all applicable provisions of the regulations listed below and are in conformity with the following standards.
  • Technical file at: Robert Bosch Ltd. (PT/SOP-GB), Broadwater Park, North Orbital Road, Uxbridge UB9 5HJ, United Kingdom
  • The Supply of Machinery (Safety) Regulations 2008
  • The Electromagnetic Compatibility Regulations 2016
  • The Restriction of the Use of Certain Hazardous Substances in
  • Electrical and Electronic Equipment Regulations 2012
  • EN 60335-1:2012+A11:2014+A13:2017+
  • A1:2019+A2:2019+A14:2019+A15:2021
  • EN 60335-2-69:2012
  • EN 55014-1:2017+A11:2020
  • EN 55014-2:2015
  • EN IEC 61000-3-2:2019
  • EN 61000-3-3:2013+A1:2019
  • EN IEC 63000:2018
  • Robert Bosch Ltd. Broadwater Park, North Orbital Road, Uxbridge UB9 5HJ, United Kingdom, as authorised representative acting on behalf of Robert Bosch Power Tools GmbH, 70538 Stuttgart, Germany
  • Place of issue: Uxbridge Date of issue: 14/10/2023
    BOSCH-GAS-55-M-AFC-Professional-Wet-and-Dry-Vacuum-Cleaner-
\(445\)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals