S4A HD3 Acces Controller Reader User Manual
- June 1, 2024
- S4A
Table of Contents
HD3 Acces Controller Reader
User Manual User Manual
INTRODUCTION
The device is a single door multifunction standalone access controller or a
Wiegand output reader. It uses Atmel MCU assuring stable performance.
The operation is very user-friendly, and low-power circuit makes it long
service life.
The device can be made with Bluetooth function or with WIFI function.
Card/ PIN device:
It supports 10,000 users (9988 common + 2 panic + 10 visitor)
Card/ PIN/ Fingerprint device:
Three user capacities are available:
- It supports 10,000 card/ PIN users + 100 fingerprint users
- It supports 10,000 card/ PIN users + 500 fingerprint users
- It supports 10,000 card/ PIN users + 880 fingerprint users
Features
OLED display, touch keypad
Wide: ABS, Slim: metal case, anti-vandal
Waterproof, conforms to IP66
One relay
PIN length: 4~6 digits
EM card, EM+ Mifare card optional
EM card: Wiegand 26~44 bits input & output Mifare card: Wiegand 26~44bits, 56bits, 58bits input & output
Can be used as Wiegand reader with LED & buzzer output
Card block enrollment
Tri-color LED status display
Integrated alarm & buzzer output
Pulse mode, Toggle mode
User data can be transferred
2 devices can be interlocked for 2 doors
Built-in light dependent resistor (LDR) for anti tamper
Backlit keypad, can set automatic OFF after 20 seconds
User Capacity | Card/ PIN | Card/ PIN/ Fingerprint |
---|
Common Card/ PIN User Common Fingerprint User Panic User
Visitor User| 9988 /
2
10| 9988
500 (100, 880 optional)
2
10
Operating Voltage
Working Current Idle Current| 12V DC (Wide device) 12-18V DC (Slim device)
<150mA <60mA
Proximity Card Reader Radio Technology
Read Range| EM or EM+Mifare
125KHz or 125KHz+ 13.56MHz 2-6 cm
PIN Length| 4-6 digits
Wiring Connections| Relay Output, Exit Button, Alarm, Door Contact, Wiegand
Input, Wiegand Output
Relay
Adjustable Relay Output Time Lock Output Load| One (NO, NC, Common)
0-99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand Interface
PIN Output| EM card version: Wiegand 26-44 bits
input & output (Factory Default: Wiegand 26bits)
Mifare card version: Wiegand 26-44bits, 56bits, 58bits input & output
(Factory Default: Wiegand 34bits)
4 bits, 8 btts(ASCII), 10 dialtsVktual Number
(Factory Default: 4 bits)
Environment
Operating Temperature
Operating Humidity| Meets IP66
Card/ PIN device: -40°C- 60°C (-40°F – 140°F) Card/ PIN/ Fingerprint device:
-30°C – 60°C (-22°F – 140°F)
0%RH-98%RH
Physical
Colour
Dimensions
Unit Weight Shipping Weight| Wide: ABS Slim: Zinc-Alloy
Wide: Black Slim: Silver & Black
Wide: L116 x W76 x D24 (mm) Slim: L148 x W43.5 x D22 (mm)
Wide: 160g Slim: 330g
Wide: 185g Slim:405g
Wiring (for Wide device)
Color | Function | Notes |
---|---|---|
Red | +12V | 12V DC Power Input |
Black | GND | Negative Pole of DC Power Input |
Blue | NO | Normally Open Relay Output |
Purple | COM | Common Connection for Relay Output |
Orange | NC | Normally Closed Relay Output |
Yellow | OPEN | Request to Exit (REX)Input |
White | D1 | Wiegand Output /Input Data 1 |
Green | DO | Wiegand Output /Input Data 0 |
Grey | Alarm Output | Negative contact for Alarm |
Brown | Contact Output | Door/Gate Contact Input (Normally Closed) |
Light Blue | Doorbell A | Contact for Doorbell |
Light Blue | Doorbell B | Contact for Doorbell |
Wiring (for Slim device)
Wire Color | Function | Notes |
---|
Basic Standalone Wiring
Red| DC+| 12-18V DC Power Input
Black| G N D| Negative Pole of DC Power Input
Blue & Black| Relay NO| Normally Open Relay Output (install diode provided)
White & Black| Relay Common| Common Connection for Relay Output
Green & Black| Relay NC| Normally Closed Relay Output (Install diode provided)
Yellow| OPEN| Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green| Data 0| Wiegand Output (Pass-through) Data 0
White| Data 1| Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey| Alarm Output| Negative contact for Alarm
Brown| Contact Input| Door/Gate Contact Input (Normally Closed)
Brown & Black| Doorbell A| Contact for Doorbell
Yellow & Black| Doorbell B| Contact for Doorbell
Carton Inventory
INSTALLATION
- Remove the back cover from the unit
- Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
- Knock the supplied rubber bungs to the screw holes(A,C)
- Fix the back cover firmly on the wall with 4 flat head screws
- Thread the cable through the cable hole(B)
- Attach the unit to the back cover
CONNECTION DIAGRAM :
Standalone Mode
The device can work as Standalone Access Control for single door.
(Factory default mode)
Connection Diagram (for Wide device)
Common Power Supply Attention:
Install a 1N4004 or equivalent diode is needed when use a common power
supply, or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power Supply
Connection Diagram (for Slim device)
Common Power Supply
Attention:
Install a 1N4004 or equivalent diode is needed when use a common power
supply, or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power Supply
Controller Mode
The device can work as Controller, connected with the external Wiegand
reader.
(Factory default mode)
Connection Diagram (for Wide device) Connection Diagram (for Stim
device)
Attention: Install a 1N4004 or equivalent diode is needed when use a common
power supply, or the reader might be damaged. (1N4004 is included in the
packing)
WIEGAND READER MODE
The device can work as Standard Wiegand Reader, connected to the third party
Controller
Connection Diagram
Notes:
-
When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below:
– Brown wire: Green LED light control
– Yellow wire: Buzzer control -
If you need to connect Brown/Yellow wires:
When the input voltage for LED is low, the LED will tum into Green; and when the input voltage for Buzzer is low, it will sound.
PROGRAMMING
Keys & Functions
0~9: Enter value, menu number
| # Ok means confirm
▼ means down to select
---|---
| Means doorbell
| M means menu
Short press means back to the previous menu
Long press means back to main interface
System Menu
Please input * (Master Code) # to enter system menu.
(Factory default master code is 123456)
> User ID number:
The Common Card/PIN User ID: 1~9988
Panic User ID: 9989~9990
Visitor User ID: 9991~10000
Fingerprint User ID (Only apply to card/PIN/ Fingerprint device)
10001~10100 or 10001~10500 or 10001~10880
PIN: Can be any 4~6 digits
Proximity Card: 125KHz EM card or 13.56MHz Mifare card
- Change Admin
Press ‘1’ to enter Change Admin.Menu No.| Setting| Note
---|---|---
1| Change Admin| New Admin can be any 6 digits - User Setting
Press ‘2’ to enter User Setting.
Press ▼ to select and long press # to confirm. Menu No| Setting| Note
---|---|---
1| Add Directly| Add users directly by inputting PIN/ card
2| Add by ID| Add users by user ID.
The common user ID is between 1~9988, panic
User ID is 9989~9990.
Fingerprint User ID (Only apply to card/PIN/
Fingerprint device) is 10001~10100 or
10001~10500 or 10001~10880.
3| Add Visitor| – Visitor user ID is between 9991~10000
– Add visitor card: ID# (1~9)# (read card)
– Add visitor PIN: ID# (1~9)# (PIN)#
1~9 means times of usage.
4| Block Enrol| Choose the 1st ID–Set Card Number (can set 1~200)– Read the 1st number card
5| Del Directly| – Enter PIN or card to delete user directly
6| Del by ID| – Delete users by inputting user ID
7| Del All User| – Delete ALL users - Door Setting
Press ‘3’ to enter Door Setting.
Press ▼ to select and long press # to confirm. Menu No.| setting| Note
---|---|---
1| Open Time| – Open time can be set to 0~100s
Input 0-100, long press # to confirm.
– Factory default is 5s
2| Access Mode| Access Modes can be set to:
Card/ PIN device: 1 Card, 2 PW, 3 Card/PW,
4 Multi User (max.9)
Card/ PIN/ Fingerprint device: 1 Card, 2 PW,
3 Fingerprint, 4 Card/PW/Fp, 5 Multi User
(max.9)
3| Alarm Time| – 1 OFF (Factory default)
-2 1min
-3 2min
– 4 3min
4| Door Contact| – 1 OFF (Factory default)
-20N
5| Security Mode| – 1 OFF (Factory default)
-2 LOCK Dead
The device will become ‘access deny’ for 10 minutes after 10 failed entry attempts.
Restart the device to back to normal.
– 3 Alarm Mode
The device will alarm after 10 failed entry attempts. Alarm time depends on the device alarm time (refer to Door Setting Menu No.
3 Alarm Time),enter Master Code # or valid user card/PIN to silence.
6| Interlock| – 1 OFF (Factory default)
-20N
Connection Diagram please refer to page 12
7| Collect Card| – 1 OFF (Factory default)
-20N
After this function is turned ON, all cards can open the lock, at the same time, the card is added to the device.
8| WG FMT| – 1 Check OFF
– 2 Check ON (Factory default)
Check means Parity Bit
-3 4bits (Factory default)
– 4 Bbits
– 5 10bits (VirNum)
– 61D: 26
Wiegand format for EM card can be set to 26~44,
– TIC: 34
Wiegand format for Mifare card can be set to 26~58.
9| Working Mode| – 1 Controller (Factory default)
– 2 Reader
In Controller mode, the device can be also used as standalone.
Connection diagram please refer to Page 4~6 - Other Setting
Press ‘4’ to enter Other Setting.
Press ▼ to select and long press # to confirm. Menu No.| Setting| Note
---|---|---
1| Sound| – 1 OFF
– 2 ON (Factory default)
2| Red Led| -1 OFF
– 2 ON (Factory default)
3| Keys Backlight| -1 OFF
– 2 ON
– 3 Auto (Factory default)
Automatic OFF after 20 seconds, it will go ON by pressing any key (this key isn’t taken Into considerations).
4| OLED Backlight| -1 ON
– 2 5S
– 3 10S
– 4 30S (Factory default)
– 5 1min
5| Unbind Machine| – Unbind the device
– Long press # to confirm Unbind, the device will back to main interface after unbinding successfully.
6| Copy Users| Connection diagram please refer to page 11
7| Factory Reset| Reset to factory default, the user’s information is still retained.
ADVANCED APPLICATION
User Information Transfer (Valid for Card/ PIN device)
The device supports the User Information Transfer function, and the enrolled
user (cards, PINs) can be transferred from one (let’s name it Master Unit) to
another (let’s name it Accept Unit).
Connection Diagram:
Remarks:
The Master units and Accept units must be same series devices.
The Master Code of the Master Unit and the Accept Unit must be set to the same.
Program the transfer operation on Master Unit only.
If the Accept Unit is already with the users enrolled, it will be covered after transferring.
For full 10000 users enrolled, the transfer takes about 5 minutes.
Set Transferring on Master Unit: Menu 4 Other Setting— 6 Copy User
Interlock
The device supports the Interlock Function. It is of two Devices for two
doors, and mainly used for banks, prisons, and other places where a higher
level security is required.
Connection Diagram:
Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A “and “B” for two doors “1” and “go
Step 1:
Enroll the users on Device A, then transfer the users’ information to Device B
by ‘User Information Transfer’ function (Page 111)
Step 2:
Set both of the two Devices (A and B) to Interlock function
Menu 3 Door Setting — 6 Interlock
lf enable interlock, when and only door 2 is closed, the user can read the
valid fingerprint/card or input PIN on Reader A, door 1 will open; then when
and only door 1 closed, read valid fingerprint/card or input PIN on Reader B,
door 2 will open.
SOUND AND LIGHT INDICATION
Operation Status | LED | Buzzer |
---|---|---|
Stand by | Red light bright | – |
Enter into programming mode | Red light shines | One beep |
In the programming mode | Orange light bright | One beep |
Operation error | – | Three beeps |
Exit from the Programming mode | Red light bright | One beep |
Open lock | Green light bright | One beep |
Alarm | Red light Shines quickly | Beeps |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>