S4A H3 Access Controller Reader With Doorbell User Manual
- June 15, 2024
- S4A
Table of Contents
- INTRODUCTION
- Features
- Specifications
- User Capacity
- 1000
- 9
- 88210
- Operating Voltage
- Working Current Idle Current
- 12-18V DC<150mA<60mA
- Proximity Card Reader Radio
- Technolo
- gyRead Range
- EM / EM + Mifare 125KHz/ 125KHz + 13.56MHz 2-6 cm
- PIN Length
- 4-6 digits
- Wiring Connections
- Relay Output, Exit Button, Alarm, Door **Contact, Wiegand Input,
- Relay Adjustable Relay Output Time Lock Output Load
- One (NO, NC, Common) 0-99 Seconds (5 seconds default) 2 Amp Maximum
- Wiegand Interface PIN Output
- EM card: Wiegand 26-44 bits input & **output. Mifare card:
- Environment Operating Temperature Operating Humidity
- Meets IP66 -40°C – 60°C (-40°F – 140°F) 0%RH-98%RH
- Physical ColourDimensionsUnit Weight Shipping Weight
- Zinc-Alloy (A/B) ABS(C) Silver & Black (A/B)
- **Carton Inventory
- INSTALLATION
- Wiring
- Wire Color
- Function
- Notes
- Basic Standalone Wiring
- Red
- DC +
- 12-18V DC Power Input
- Black
- GND
- Negative Pole of DC Power Input
- Blue & Black
- Relay NO
- Normally Open Relay Output (install diode provided)
- White & Black
- Relay Common
- Common Connection for Relay Output
- Green & Black
- Relay NC
- Normally Closed Relay Output (Install diode provided)
- Yellow
- OPEN
- Request to Exit(REX) Input
- Pass-Through Wiring (Wiegand
- Reader or Controller)
- Green
- Data 0
- Wiegand Output (Pass-through) Data 0
- White
- Data 1
- Wiegand Output (Pass-through) Data 1
- Advanced Input and Output Features
- Grey
- Alarm Output
- Negative contact for Alarm
- Brown
- Contact Input
- Door/Gate Contact Input (Normally Closed)
- Brown & Black
- Doorbell A
- Contact for Doorbell
- Yellow & Black
- Doorbell B
- Contact for Doorbell
- Sound and Light Indication
- Operation Status
- LED
- Buzzer
- Stand by
- Red light bright
- Enter into programming mode
- Red light shines
- One beep
- In the programming mode
- Orange light bright
- One beep
- Operation error
- Three beeps
- Exit from the Programming mode
- Red light bright
- One beep
- Open lock
- Green light bright
- One beep
- Alarm
- Red light Shines quickly
- Beeps
- Basic Configure
- Enter and Exit Program Mode
- Programming Step
- Keystroke Combination
- Enter Program Mode
- * (Master Code) # (Factory default is 123456
- Exit Program Mode
- *
- Set Master Code
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Update Master Code
- 0 (New Master Code) # (Repeat New Master Code) #(Master code is any 6
- 3. Exit Program Mode
- *
- Set the Working Mode
- Notes: The device has 3 working modes: Standalone Mode, Controller
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- Standalone/Controller Mode OR 2. Wiegand Reader Mode
- 77 # (Factory default) 78#
- 3. Exit
- *
- STANDALONE MODE
- The device can work as Standalone Access Control for single door.
- Connection Diagram
- **Common Power Supply
- Attention:
- Install a 1N4004 or equivalent diode is needed when use a common power
- **Access Control Power Supply
- Programming
- Programming will be varied depending on access configuration. Follow the
- Notes:
- The Common User ID: 0~987
- Panic User ID: 988~989
- Visitor User ID: 990~999
- ****
- IMPORTANT : User IDs do not have to be proceeded with any leading
- Proximity Card:
- PIN: Can be any 4-6 digits except 8888 which is reserved. Add Common
- PIN / Card user ID: 0~987; PIN length: 4-6 digits except 8888
- Add Common Users
- PIN/ Card user ID: 0~987; PIN length: 4~6 digits except 8888
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- Add Card User
- Using Auto ID(Allows the device to assign Card to next available User ID
- OR2. Select Specific ID(Allows Master to define a specific User ID to
- Add Card: Block Enrollment (Allows Master to add up to 988 cards to the
- Card Number) # The cards can be added continuously. (User ID) # (Read
- Add PIN User
- (Allows the device to assign PIN to next available User ID number)OR2.
- 1 (PIN) #The PINs can be added continuously1 (User ID) # (PIN) #
- . Exit
- *
- Tips for PIN Security (Only valid for 6 digits PIN):
- For higher security we allow you to hide your correct PIN with other
- Example PIN: 123434
- Add Panic Users
- (User ID number is 988, 989; PIN length: 4~6 digits except 8888)
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Add CardOR2. Add PIN1
- 1 (User ID) # (Read Card/Input 8/10 /17 Digits Card number) #1 (User ID)
- (PIN) #
- 3. Exit
- *
- Add Visitor Users
- (User ID number is 990~999; PIN length: 4~6 digits except 8888) There
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- *(Master Code) #
- 2. Add CardOR2. Add PIN
- 1 (User ID) # (0~9) # (Read Card)/ (Input 8/10/17 Digits Card Number) #1
- 3. Exit
- *
- Change PIN Users (PIN length : 4-6 digits except 8888)
- (Note : WiFi versions don’t support change PIN)
- Programming Step
- Keystroke Combination
- Note: Below is done outside programming mode, users can undertake this
- Change PIN
- * (User ID) # (Old PIN) # (New PIN) # (Repeat New PIN) #
- Change PIN of Card + PIN access mode (There will auto allocate PIN (8888)
- Read Card) (Old PIN) # (New PIN) # (Repeat New PIN) #
- **Delete Users
- Programming Step
- Keystroke Combination*
- 1. Enter Program Mode
- * (Master Code) #
- OR2. Delete User – By ID numberOR2. Delete User – By Card numberOR2.
- 2 (User ID)#2 (input 8/10/17 Digits Card Number) #2 (Master Code) #
- 3. Exit
- *
- Set Relay Configuration
- The relay configuration sets the behavior of the output relay on
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Pulse ModeOR2. Toggle Mode
- 3 (1~99) # (factory default) The relay time is 1-99 seconds. (Default is
- 3. Exit
- *
- Set Access Mode
- For Multi user access mode, the interval time of reading can not exceed
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2 Card AccessOR2 PIN AccessOR2 Card + PIN AccessOR2 Card or PIN AccessOR2
- * (Master Code) #40#41#42 # (WiFi versions don’t support this function)43
- (factory default)43 (2~9) #(Only after 2-9 valid users, the door can be
- 3. Exit
- *
- Set Strike-out Alarm
- The strike-out alarm will engage after 10 failed entry attempts (Factory
- Simplified Instruction
- Function Description
- Operation
- Enter the Programming Mode
- * – Master Code – # then you can do the programming (123456 is the
- Change the Master Code
- 0 – New Code -# – Repeat the New Code – # (code: 6 digits)
- Add Card User
- 1 – Read Card – # (can add cards continuously)
- Add PIN User
- 1 – PIN -# (The PIN is any 4-6 digits except 8888 which is reserved
- Delete User
- 2 – Read Card – #2 – PIN – #
- Exit from the Programming Mode
- *
- How to release the door
- Card User
- Read Card
- PIN User
- Input PIN #
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Strike-Out OFF OR 2. Strike-Out ON OR 2. Strike-Out ON
- 6 0 # (factory default) 61 # Access will be denied for 10
- 3. Exit
- *
- Set Door Open Detection
- Door Open Too Long (DOTL) Detection
- When use with an optional magnetic contact or built-in magnetic contact
- Door Forced Open Detection
- When use with an optional magnetic contact or built-in magnetic contact
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Disable Door Open Detection OR 2. Enable Door Open Detection
- 6 3 # (factory default) 6 4 # 5 (0 — 3) # (factory
- 3. Exit
- *
- The function of Set Alarm Time also apply for anti-tamper alarm
- Set Audible and Visual Response
- Programming Step
- Keystroke Combination
- Enter Program Mode
- * (Master Code) #
- 2. Disable Sound Enable SoundOR2. LED Always OFFLED Always ONOR2. Keypad
- 70#71# (factory default)72#73 # (factory default)74#75#76 # (factory
- 3. Exit
- *
- Master Card Usage
- Using Master Card to add and delete users
- Add Card/ PIN Users
- 1. Input (Master Card)
- 2. Input (Card) or (PIN #)
- Repeat step 2 for additional users
- 3. Input (Master Card) again
- Delete Card/ PIN Users
- 1. Input (Master Card Twice within 5s)2. Input (Card) or (PIN #) Repeat
- Users Operation & Reset to Factory Default
- Remarks
- CONTROLLER MODE
- The device can work as Controller, connected with the external Wiegand
- **Connection Diagram
- Set Wiegand Input Formats
- Please set the Wiegand input formats according to the Wiegand output
- Programming Step
- Keystroke Combination
- 1. Enter Program Mode
- * (Master Code) #
- 2. Wiegand Input Bit
- For EM Card : 8 (26- 44) # (factory default is 26bits) **For Mifare
- 3. Disable Parity BitEnable Parity Bit
- 8 0 # 81 # (factory default)
- 4. Exit
- *
- Note: For connecting Wiegand readers with 32, 40, 56 bits output, need
- Programming
- If EM/Mifare card reader: users can be added/deleted on either the device
- The device Connected with Fingerprint Reader
- Connect SF1 as the fingerprint reader to the device. For example:
- Step 1: Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
- Step 2: Add the same Fingerprint(A) on the device:
- The device Connected with Keypad Reader
- The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output
- Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual
- WIEGAND READER MODE
- The device can work as Standard Wiegand Reader, connected to the third
- Connection Diagram
- Notes:
- Set Wiegand Output Formats
- Please set the Wiegand output formats of Reader according to the Wiegand
- User Information Transfer
- The device supports the User Information Transfer function, and the
- **Connection Diagram:
- Remarks:
- **Set Transferring on Master Unit:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- Touch key
- Metal case, anti-vandal
- Waterproof, conforms to IP66
- One relay, 1,000 users (988 common + 2 panic + 10 visitor)
- PIN length: 4~6 digits
- EM card, EM+ Mifare cards optional
- EM card: Wiegand 26-44 bits input & output Mifare card: Wiegand 26-44bits, 56bits, 58bits input & output
- Can be used as Wiegand reader with LED & buzzer output
- Card block enrollment > Tri-color LED status display
- Integrated alarm & buzzer output
- Pulse mode, Toggle mode
- User data can be transferred
- 2 devices can be interlocked for 2 doors
- Built-in light dependent resistor (LDR) for anti tamper > Backlit keypad, can set automatic OFF after 20 seconds
- Diode IN4004 (For relay circuit protection)
- Wall Anchors
- Self Tapping Screws: 4*25mm
- Screw Driver
- Master Card
- Remove the back cover from the unit > Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
- Knock the supplied rubber bungs to the screw holes(A,C)
- Fix the back cover firmly on the wall with 4 flat head screws
- Thread the cable through the cable hole(B)
- Attach the unit to the back cover
- User ID number: Assign a user ID to the access card/ PIN in order to track it.
- Open the door : Read valid user card or input valid user PIN
- Remove Alarm : Enter Master Code # or Master Card or valid user card / PIN
- To reset to factory default & Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
- If no Master Card added, must press the Exit Button for at least 5 seconds before release. (this will make the previous registered Master Card invalid)
- Reset to factory default, the user’s information is still retained.
- Basic Programming is the same as Standalone Mode
- There are some exceptions for your attention:
- The device Connected with External Card Reader
- Add PIN Users: To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either thedevice or the external Keypad Reader.
- Delete PIN Users: the same way as add users.
- When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below
- Brown wire: Green LED light control
- Yellow wire: Buzzer control
- > If you need to connect Brown/Yellow wires: When the input voltage for LED is low, the LED will turn into Green; and when the input voltage for Buzzer is low, it will sound.
- The Master units and Accept units must be same series devices.
- The Master Code of the Master Unit and the Accept Unit must be set to the same.
- Program the transfer operation on Master Unit only.
- If the Accept Unit is already with the users enrolled, it will be covered after transferring.
- For full 1000 users enrolled, the transfer takes about 30 seconds.
**S4A H3 Access Controller Reader With Doorbell User Manual
**
INTRODUCTION
The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long service life.The device supports 1,000 users (988 common users + 2 panic users + 10 visitor users), all user data can be transferred from one to another. It supports multi access modes in card access, PIN access, card + PIN access, or multi cards/PINs access. It has extra features including block enrollment, interlock, Wiegand input & output interface…etc.Three Versions Optional: The device with Bluetooth function is optional The device with big user capacity is optional The device with WiFi function is optional
Features
-
Touch key
-
Metal case, anti-vandal
-
Waterproof, conforms to IP66
-
One relay, 1,000 users (988 common + 2 panic + 10 visitor)
-
PIN length: 4~6 digits
-
EM card, EM+ Mifare cards optional
-
EM card: Wiegand 26-44 bits input & output Mifare card: Wiegand 26-44bits, 56bits, 58bits input & output
-
Can be used as Wiegand reader with LED & buzzer output
-
Card block enrollment > Tri-color LED status display
-
Integrated alarm & buzzer output
-
Pulse mode, Toggle mode
-
User data can be transferred
-
2 devices can be interlocked for 2 doors
-
Built-in light dependent resistor (LDR) for anti tamper > Backlit keypad, can set automatic OFF after 20 seconds
Specifications
User Capacity
Common User
Panic UserVisitor
User
|
1000
9
88210
---|---
Operating Voltage
Working Current Idle Current
|
12-18V DC<150mA<60mA
Proximity Card Reader Radio
Technolo
gyRead Range
|
EM / EM + Mifare 125KHz/ 125KHz + 13.56MHz 2-6 cm
PIN Length
|
4-6 digits
Wiring Connections
|
Relay Output, Exit Button, Alarm, Door **Contact, Wiegand Input,
Wiegand Output**
Relay Adjustable Relay Output Time Lock Output Load
|
One (NO, NC, Common) 0-99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand Interface PIN Output
|
EM card: Wiegand 26-44 bits input & **output. Mifare card:
Wiegand 26-44bits 56bits, 58bits input & output.(Factory default: Wiegand 26bits for EM card, Wiegand 34bits for Mifare card) 4 bits, 8 bits(ASCII), 10 digits Virtual Number** (Factory Default: 4 bits)
Environment Operating Temperature Operating Humidity
|
Meets IP66 -40°C – 60°C (-40°F – 140°F) 0%RH-98%RH
Physical ColourDimensionsUnit Weight Shipping Weight
|
Zinc-Alloy (A/B) ABS(C) Silver & Black (A/B)
Black(C)L148 x W43.5 x D22 (mm) –A /C L165 x W44 x D22 (mm)– B330g–A 415g — B 190g — C405g — A 500g — B 280g — C
**Carton Inventory
**
-
Diode IN4004 (For relay circuit protection)
-
Wall Anchors
-
Self Tapping Screws: 4*25mm
-
Screw Driver
-
Master Card
INSTALLATION
-
Remove the back cover from the unit > Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
-
Knock the supplied rubber bungs to the screw holes(A,C)
-
Fix the back cover firmly on the wall with 4 flat head screws
-
Thread the cable through the cable hole(B)
-
Attach the unit to the back cover
Wiring
Wire Color
|
Function
|
Notes
---|---|---
Basic Standalone Wiring
Red
|
DC +
|
12-18V DC Power Input
Black
|
GND
|
Negative Pole of DC Power Input
Blue & Black
|
Relay NO
|
Normally Open Relay Output (install diode provided)
White & Black
|
Relay Common
|
Common Connection for Relay Output
Green & Black
|
Relay NC
|
Normally Closed Relay Output (Install diode provided)
Yellow
|
OPEN
|
Request to Exit(REX) Input
Pass-Through Wiring (Wiegand
|
Reader or Controller)
Green
|
Data 0
|
Wiegand Output (Pass-through) Data 0
White
|
Data 1
|
Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey
|
Alarm Output
|
Negative contact for Alarm
Brown
|
Contact Input
|
Door/Gate Contact Input (Normally Closed)
Brown & Black
|
Doorbell A
|
Contact for Doorbell
Yellow & Black
|
Doorbell B
|
Contact for Doorbell
Sound and Light Indication
Operation Status
|
LED
|
Buzzer
---|---|---
Stand by
|
Red light bright
|
Enter into programming mode
|
Red light shines
|
One beep
In the programming mode
|
Orange light bright
|
One beep
Operation error
|
|
Three beeps
Exit from the Programming mode
|
Red light bright
|
One beep
Open lock
|
Green light bright
|
One beep
Alarm
|
Red light Shines quickly
|
Beeps
Basic Configure
Enter and Exit Program Mode
Programming Step
|
Keystroke Combination
---|---
Enter Program Mode
|
* (Master Code) # (Factory default is 123456
Exit Program Mode
|
*
Set Master Code
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Update Master Code
|
0 (New Master Code) # (Repeat New Master Code) #(Master code is any 6
digits)
3. Exit Program Mode
|
*
Set the Working Mode
Notes: The device has 3 working modes: Standalone Mode, Controller
Mode, Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone Mode / Controller Mode)
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
Standalone/Controller Mode OR 2. Wiegand Reader Mode
|
77 # (Factory default) 78#
3. Exit
|
*
STANDALONE MODE
The device can work as Standalone Access Control for single door.
(Factory default mode) — 77#
Connection Diagram
**Common Power Supply
**
Attention:
Install a 1N4004 or equivalent diode is needed when use a common power
supply, or the keypad might be damaged. (1N4004 is included in the packing)
**Access Control Power Supply
**
Programming
Programming will be varied depending on access configuration. Follow the
instructions according to your access configuration.
Notes:
-
User ID number: Assign a user ID to the access card/ PIN in order to track it.
The Common User ID: 0~987
Panic User ID: 988~989
Visitor User ID: 990~999
****
IMPORTANT : User IDs do not have to be proceeded with any leading
zeros. Recording of User ID is critical. Modifications to the user require the User ID be available.
Proximity Card:
Proximity Card: EM card/ EM+ Mifare cards
PIN: Can be any 4-6 digits except 8888 which is reserved. Add Common
Users
PIN / Card user ID: 0~987; PIN length: 4-6 digits except 8888
Add Common Users
PIN/ Card user ID: 0~987; PIN length: 4~6 digits except 8888
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
Add Card User
Using Auto ID(Allows the device to assign Card to next available User ID
number)
OR2. Select Specific ID(Allows Master to define a specific User ID to
associate the card to)2.
Add Card: Block Enrollment (Allows Master to add up to 988 cards to the
Reader in a single step) Takes minutes to program.
|
Card Number) # The cards can be added continuously. (User ID) # (Read
Card) / (Input 8/10/17 Digits Card Number) #1 (User ID) # (Card Quantity) # (The First Card 8/10/17 Digits Number) # Cards’ number must be consecutive; Card quantity= numbers of cards to be enrolled
Add PIN User
(Allows the device to assign PIN to next available User ID number)OR2.
Select Specific ID(Allows manager to define a specific User ID to associate the PIN to)
|
1 (PIN) #The PINs can be added continuously1 (User ID) # (PIN) #
. Exit
|
*
Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other
numbers up to a max of 10 digits.
Example PIN: 123434
You could use (123434) or * (123434)
(“” can be any numbers from 0~9)
Add Panic Users
(User ID number is 988, 989; PIN length: 4~6 digits except 8888)
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Add CardOR2. Add PIN1
|
1 (User ID) # (Read Card/Input 8/10 /17 Digits Card number) #1 (User ID)
(PIN) #
3. Exit
|
*
Add Visitor Users
(User ID number is 990~999; PIN length: 4~6 digits except 8888) There
are 10 groups Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5 times, the PIN/card become invalid automatically.
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
*(Master Code) #
2. Add CardOR2. Add PIN
|
1 (User ID) # (0~9) # (Read Card)/ (Input 8/10/17 Digits Card Number) #1
(User ID) # (0~9) # (PIN) #
3. Exit
|
*
Change PIN Users (PIN length : 4-6 digits except 8888)
(Note : WiFi versions don’t support change PIN)
Programming Step
|
Keystroke Combination
---|---
Note: Below is done outside programming mode, users can undertake this
Change PIN
|
* (User ID) # (Old PIN) # (New PIN) # (Repeat New PIN) #
Change PIN of Card + PIN access mode (There will auto allocate PIN (8888)
to cards when adding
|
Read Card) (Old PIN) # (New PIN) # (Repeat New PIN) #
**Delete Users
**
Programming Step
|
Keystroke Combination*
---|---
1. Enter Program Mode
|
* (Master Code) #
OR2. Delete User – By ID numberOR2. Delete User – By Card numberOR2.
Delete ALL Users
|
2 (User ID)#2 (input 8/10/17 Digits Card Number) #2 (Master Code) #
3. Exit
|
*
Set Relay Configuration
The relay configuration sets the behavior of the output relay on
activation.
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Pulse ModeOR2. Toggle Mode
|
3 (1~99) # (factory default) The relay time is 1-99 seconds. (Default is
5 seconds)30#
3. Exit
|
*
Set Access Mode
For Multi user access mode, the interval time of reading can not exceed
5 seconds, or else, the device will exit to standby automatically.
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2 Card AccessOR2 PIN AccessOR2 Card + PIN AccessOR2 Card or PIN AccessOR2
Multi User Access
|
* (Master Code) #40#41#42 # (WiFi versions don’t support this function)43
(factory default)43 (2~9) #(Only after 2-9 valid users, the door can be
opened)
3. Exit
|
*
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory
is OFF). It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid card/PIN or Master code / card.
Simplified Instruction
Function Description
|
Operation
Enter the Programming Mode
|
* – Master Code – # then you can do the programming (123456 is the
factory default master code)
Change the Master Code
|
0 – New Code -# – Repeat the New Code – # (code: 6 digits)
Add Card User
|
1 – Read Card – # (can add cards continuously)
Add PIN User
|
1 – PIN -# (The PIN is any 4-6 digits except 8888 which is reserved
)
Delete User
|
2 – Read Card – #2 – PIN – #
Exit from the Programming Mode
|
*
How to release the door
Card User
|
Read Card
PIN User
|
Input PIN #
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Strike-Out OFF OR 2. Strike-Out ON OR 2. Strike-Out ON
(Alarm) Set Alarm Time
|
6 0 # (factory default) 61 # Access will be denied for 10
minutes (Exit button is still workable) 6 2 # 5 (0 – 3) # (factory default is 1 minute) Enter Master Code # or Master Card or valid user card/ PIN to silence
3. Exit
|
*
Set Door Open Detection
Door Open Too Long (DOTL) Detection
When use with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door. The beep can be stopped by closing the door, master users or valid users, or else, it will continue to beep the same time with the alarm time set.
Door Forced Open Detection
When use with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is opened by force, the inside buzzer and external alarm (if there is) will both operate, they can be stopped by master users or valid users, or else, it will continue to sound the same time with the alarm time set.
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Disable Door Open Detection OR 2. Enable Door Open Detection
Set Alarm Time
|
6 3 # (factory default) 6 4 # 5 (0 — 3) # (factory
default is 1 minute)
3. Exit
|
*
The function of Set Alarm Time also apply for anti-tamper alarm
Set Audible and Visual Response
Programming Step
|
Keystroke Combination
---|---
Enter Program Mode
|
* (Master Code) #
2. Disable Sound Enable SoundOR2. LED Always OFFLED Always ONOR2. Keypad
Backlit Always OFFKeypad Backlit Always ONKeypad Backlit Automatic OFF
|
70#71# (factory default)72#73 # (factory default)74#75#76 # (factory
default)Automatic OFF after 20 seconds, it will go ON by pressing any key (this key isn’t taken into consideration)
3. Exit
|
*
Master Card Usage
Using Master Card to add and delete users
Add Card/ PIN Users
|
1. Input (Master Card)
2. Input (Card) or (PIN #)
Repeat step 2 for additional users
3. Input (Master Card) again
Delete Card/ PIN Users
|
1. Input (Master Card Twice within 5s)2. Input (Card) or (PIN #) Repeat
step 2 for additional users3. Input (Master Card) again
Users Operation & Reset to Factory Default
-
Open the door : Read valid user card or input valid user PIN
-
Remove Alarm : Enter Master Code # or Master Card or valid user card / PIN
-
To reset to factory default & Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
Remarks
-
If no Master Card added, must press the Exit Button for at least 5 seconds before release. (this will make the previous registered Master Card invalid)
-
Reset to factory default, the user’s information is still retained.
CONTROLLER MODE
The device can work as Controller, connected with the external Wiegand
reader. (Factory default mode) — 77 #
**Connection Diagram
Attention: Install a 1N4004 or equivalent diode is needed when use a common
power supply, or the reader might be damaged. (1N4004 is included in the
packing)
**
Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output
format of the external Reader.
Programming Step
|
Keystroke Combination
---|---
1. Enter Program Mode
|
* (Master Code) #
2. Wiegand Input Bit
|
For EM Card : 8 (26- 44) # (factory default is 26bits) **For Mifare
Card: 8 0 (26-44, 56, 58) #** (factory default is 34bits)
3. Disable Parity BitEnable Parity Bit
|
8 0 # 81 # (factory default)
4. Exit
|
*
Note: For connecting Wiegand readers with 32, 40, 56 bits output, need
disable parity bits.
Programming
-
Basic Programming is the same as Standalone Mode
-
There are some exceptions for your attention:
-
The device Connected with External Card Reader
-
If EM/Mifare card reader: users can be added/deleted on either the device
or external reader.
* #### If HID card reader: users can only be added/deleted on extemal reader.
The device Connected with Fingerprint Reader
Connect SF1 as the fingerprint reader to the device. For example:
Step 1: Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
Step 2: Add the same Fingerprint(A) on the device:
1 | Enter Program Mode: * (Master Code) # |
---|
1 (Press Fingerprint A once on SF1) # (ID auto allocated)1 (User ID) # (Press
Fingerprint A on SF1) # (Select specific ID)
3| Exit: *
The device Connected with Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output
format. Choose the below operation according to the PIN output format of your reader.
Programming Step | Keystroke Combination |
---|---|
Enter Program Mode | * (Master Code) # |
PIN input bits | 8 (4 or 8 or 10) # (factory default is 4 bits) |
Exit | * |
Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual
number
-
Add PIN Users: To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either thedevice or the external Keypad Reader.
-
Delete PIN Users: the same way as add users.
WIEGAND READER MODE
The device can work as Standard Wiegand Reader, connected to the third
party Controller-78#
Connection Diagram
Notes:
-
When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below
-
Brown wire: Green LED light control
-
Yellow wire: Buzzer control
-
-
> If you need to connect Brown/Yellow wires: When the input voltage for LED is low, the LED will turn into Green; and when the input voltage for Buzzer is low, it will sound.
Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegand
input formats of the Controller.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | * (Master Code) # |
2. Wiegand output bits PIN output bits | For EM Card: 8 (26- 44) # |
(factory default is 26bits) For Mifare Card: 8 0 (26-44, 56, 58) #
(factory default is 34bits) 8 (4 or 8 or 10) # (factory default is 4
bits)
3. Disable Parity Bit Enable Parity Bit| 8 0 # 81 # (factory
default)
4. Exit|
User Information Transfer
The device supports the User Information Transfer function, and the
enrolled user (cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s name it Accept Unit).
**Connection Diagram:
**
Remarks:
-
The Master units and Accept units must be same series devices.
-
The Master Code of the Master Unit and the Accept Unit must be set to the same.
-
Program the transfer operation on Master Unit only.
-
If the Accept Unit is already with the users enrolled, it will be covered after transferring.
-
For full 1000 users enrolled, the transfer takes about 30 seconds.
**Set Transferring on Master Unit:
**
Programming Step | Keystroke Combination |
---|---|
1. Enter the programming mode | * (Master Code) # |
2. Set transferring | 98 |
Within 30 seconds, Green LED shines, after one beep, the LED will turn into
Red, which means the users’ information has been transferred successfully
Exit| *
Interlock
The device supports the Interlock Function. It is of two Devices for two doors, and mainly used for banks, prisons, and other places where a higher level security is required.
Connection Diagram:
Remarks : The Door Contact must be installed and connected as the diagram. Let’s name the two Devices as “A “and “B” for two doors “1” and “2”
Step 1:
Enroll the users on Device A, then transfer the users’ information to Device B
by “User Information Transfer” function.
Step 2:
Set both of the two Devices (A and B) to Interlock function
Programming Step | Keystroke Combination |
---|---|
1. Enter the programming mode | * (Master Code) # |
2. Set transferring | 98 |
Within 30 seconds, Green LED shines, after one beep, the LED will turn into
Red, which means the users’ information has been transferred successfully
3. Exit| *
If enable interlock, when and only door 2 is closed, the user can read the valid fingerprint/card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid fingerprint/card or input PIN on Reader B, door 2 will open.
Read User Manual Online (PDF format)