ANDTE DS190P Pints Commercial Dehumidifier User Manual

June 15, 2024
ANDTE

ANDRE - logo

Commercial Dehumidifier
User Manual

DS190P Pints Commercial Dehumidifier

ANDRE DS190P Pints Commercial Dehumidifier -

Model No.: DS190P

Please read this User Manual before operating and save for future reference.

Welcome
Thanks for choosing ANDTE dehumidifier!
ANDTE is dedicated to keeping people healthy, comfortable and more enjoyable by offering quality appliances ranging from dehumidifiers to ice makers, and more. From breathing easier in your office to upgrading your kitchen appliances, we hope ANDTE could help you every step of the way.

Thanks for choosing ANDTE dehumidifier!
ANDTE is dedicated to keeping people healthy, comfortable and more enjoyable by offering quality appliances ranging from dehumidifiers to ice makers, and more. From breathing easier in your office to upgrading your kitchen appliances, we hope ANDTE could help you every step of the way. ANDTE DS190P commercial dehumidifier can remove 190 PPD at saturation (95°F, 90% RH) and 90 PPD at AHAM (80°F, 60% RH), reducing humidity to comfortable levels in a short period of time. This dehumidifier has a solid case to withstand harsh environments, is safe and easy to use, guarantees long- term use and easy maintenance,plus we use a copper tube condenser and high quality and accurate sensors, it will be more effective and last longer.
Before plugging in your new dehumidifier, we suggest that you read this user manual as it contains important safety information, operation instructions, troubleshooting, maintenance tips, and warranty information to ensure the reliability and longevity of your dehumidifier.
We’re always just an email away
To access customer support, please email to AndteServices@outlook.com with your purchase order ID to help us address the problem faster and serve you better.
Thank you again!

Safety Information

  •  Install the dehumidifier on flat surface to minimize vibration and/or noise.
  • Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged.
  • Insert the three-prong plug on the power cord into a matching electrically grounded outlet (120V/ 60 Hz, 15A atleast). Do not use an adapter. Never cut offthe third prong.Do not use an extension cord.
  • Do not operate the dehumidifier in standing water.Keep motor and wiring dry.
  •  Neverimmerse the dehumidifier into water or other liquids.
  •  Do not put the dehumidifier close to heat-generating devices, induding flammable or dangerous materials.
  •  Unplug the power supply before cleaning or storing the dehumidifier. Always grasp the plug (not the cord) to unplug.
  • Do not put fingers or other items into air inlet or air outlet.
  • Neverinsert any other objects into the dehumidifier body.
  •  Do not sit, stand or put heavy objects on the dehumidifier.
  • This dehumidifier should only be used by adults who have read the manual and understand the operating procedure of the dehumidifier.
  • The dehumidifier is not to be used by persons (induding children) with reduced physical, sensory or mental capabilities, or lack ofexperience and knowledge, unless they have been given supervision or instruction by an adult.

Never repair or remove plug and or power cord. Any repairs should be completed by qualified electrician or distributor.

Introduction

Thank you for choosing the dehumidifier by ANDTE!
We hope it will bring great convenience to your work and life.
We recommend that you save the user manual properly for future reference.
Before using this product, please read the user manual carefully to ensure that this product functions at its best.
The ANDTE’s dehumidifier adopt an upgraded design, compact structure, easy to operate, and other characteristics, widely used in scientific research, basement, crawl space, greenery, laboratory, gymnasium, sanitation, commodity storage, underground engineering, and dehumidification in high humidity places such as kitchens, bathrooms, archives, warehouses, etc.  Can be effectively avoided telecommunications equipment, materials, etc, are damaged due to dampness or rust.
Transportation and Custody
During transportation, this product should be handled preciously to prevent violent vibration. Generally, the packaged product should not be stored in the open air for a long time. It should be placed in a well-ventilated, non- corrosive gas warehouse. It should not be placed upside down. Rainproof measures should be adopted when stored temporarily.

Important Safety Tips

Before using the product, for safe and correct operation and maintenance, please read and understand the following safety tips.

  1. When cleaning or storing the dehumidifier, please pull out the plug first, cut off the power supply, and ensure safety.
  2. Don’timmerse the machine in water or close to water sources.
  3. Don’t place the machine near heating devices or flammable dangerous goods.
  4. Don’tinsert fingers or stick-like objects into the air inlet or outlet.
  5. Please ensure that the drainpipe is installed downwards so that the condensate can drain continuously.
  6. The fuselage should be placed or installed horizontally to avoid tilting the fuselage.
  7. Never spray the machine with water.
  8. Don’t spray pesticides or flammable liquids on the machine.
  9. Don’t place heavy objects on the machine or let children and animals ride.
  10. The machine should not be operated in a confined and narrow space.
  11. If the power cord is damaged, to avoid danger, it must be repaired or replaced by the manufacturer or its maintenance department or full-time maintenance personnel.
  12. The power wiring of the machine must be carried out by the national standard wiring rules, and the power cord must be reliably connected to the external grounding wire.
  13. The fixed wiring of the machine connection must be equipped with an all-pole disconnection device (air switch) with a contact distance of at least 0.12inch.
  14. The model specification of the fuse is: 3.15A.
  15. The distance between the machine and surrounding objects should be kept at least: 40 inch.
  16. The dehumidifier is not allowed to be used by persons (including children) who are physical, sensory, or mentally retarded or lack experience and knowledge, don’t touch the machine unless under the supervision or direction of an adult.
  17. Children should be under the supervision of adults to ensure that they do not touch the machine at will

Parts Identification

ANDRE DS190P Pints Commercial Dehumidifier - parts

  1.  Handle Bar
  2.  Control Panel
  3.  Wheels
  4. Air Inlet
  5. Natural outfall
  6. Pump outlet

NOTE: There May be slight differences in the model, the actual machine shall prevail.

ANDRE DS190P Pints Commercial Dehumidifier - parts1

  1. Air Outlet
  2. Cord Winder
  3.  Power Cord Port
  4. Pump access port

Operation Instruction

Operation panel

ANDRE DS190P Pints Commercial Dehumidifier - panel

Buttons Definition

Button| Function
POWER Button| Press to turn the dehumidifier ON or OFF.
UP Button| Press to increase the set-point of humidity level or timer.
DOWN Button| Press to decrease the set-point of humidity level or timer.
TIMER Button| Press to enable the timer function or confirm the timer settings.
PUMP Button| Press and hold the PUMP button for 3-5 seconds to empty water from the pump reservoir manually.
When the water tank is empty , the pump does not start forcibly and the indicator light does not light up.

Operation panel
(1) Target Humidity Value Setting

  1. Check the room humidity (After powering on, the digital number on the control panel is the room humidity readout.);
  2.  Press UP or DOWN button once, the digital number will turn to be the previous setting value and blink;
  3.  Repeatedly press the UP or DOWN button to set a desired humidity percentage value between 10%-98% in increment of 1%. The set humidity value needs to be at least 5% lower than room humidity (The digital number keeps blinking while changes are being made);
  4. After selecting the desired value, wait for a few seconds until the digital number turns to be room humidity readout, then let the dehumidifier run.

NOTE:
The dehumidifier with a humidistat will automatically stop and restart to maintain room humidity level within a range of +3% of the set point.
For example, if the set humidity is 50%,

  • when the inlet humidity level the dehumidifier detects is 47%, 3% lower than the set humidity, the dehumidifier will automatically stop and enter into standby mode. During this time, the digital number keeps blinking
  • when the inlet humidity level the dehumidifier detects raises to 53%, 3% higher than the set humidity, it will automatically restart.
  •  However, if the set humidity level is equal to 10, the dehumidifier will enter CONTINUOUS MODE where the dehumidifier will run continuously.

(2) Timer Setting
The TIMER function enables you to either delay AUTO-ON or delay AUTO-OFF the dehumidifier in the choice from 1 hour to 24 hours.

  •  Setting an AUTO-ON timer: When the dehumidifier is on standby, selecting Timer will turn the dehumidifier on in the hours that will be set.
  •  Setting an AUTO-OFF timer: When the dehumidifier is running, selecting Timer will turn the dehumidifier off in the hours that will be set.

To Set Timer:

  1. Press the TIMER button to activate TIMER feature; (The digital number turns into 00 and blinks.)
  2. Repeatedly press the UP or DOWN button to increase or decrease the delay timer at 1-hour increments, up to 24 hours; (The digital number blinks while changes are being made.)
  3. After selected the desired TIMER setting value, press TIMER button again to confirm the timer setting. Then the digital number turns to be the room humidity readout and the TIMER indicator remains illuminated.

Note:

  •  Set AUTO ON timer when the dehumidifier is off or set AUTO OFF timer when the dehumidifier is running. It’s not allowed to set both AUTO ON and AUTO OFF timer at the same time.
  •  The Delay Start/Stop Feature will work until the dehumidifier either starts or stops
  • The TIMER will ONLY function one time instead of cycling the dehumidifier on or off indefinitely.
  • When AUTO OFF timer has been activated, press the TIMER button again could check the remaining time that the dehumidifier delays to auto off.
  • Setthe timer at 00, the timer function won’t be activated.

(3) Drainage
During operation, the pump will automatically pump the condensation out via the drain hose when the pump reservoir is full. No manual intervention!
Before moving the dehumidifier, press and hold the PUMP button for 3-5 seconds to empty the pump reservoir to avoid water spillage.
The PUMP indicator will light up and blink when the pump is working. The pump will stop working automatically and the PUMP light will go off when the pump reservoir is almost empty.
Smart Functions
Auto Drain
Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
Wait 3 Minutes before Resuming Operation
To avoid any damage to the dehumidifier, the dehumidifier will not start operation following a complete cycle until after 3 minutes. Operation will automatically start after 3 minutes.
Auto Defrost
When the frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
Auto-Restart
If the dehumidifier shuts off unexpectedly due to power being cut, the dehumidifier will restart with the previous function setting automatically when the power resumes.
Note: If the dehumidifier has been turned off before power outage, the dehumidifier will not auto restart after the power resumes.

Maintenance

Ensure the dehumidifier is turned OFF and the plug is removed from the power socket before cleaning or maintenance is carried out.

  1. Cleaning the Dehumidifier
    Clean the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners. The surface may become damaged or deformed.

  2. Cleaning the Air Filter
    The working performance of the dehumidifier will be greatly reduced if the filters become blocked. Please check and clean the filter regularly.
    To Clean the Filter
    1)Open the air filter cover

  1. Slide the filter out.
  2. Vacuum any debris from the filter using the vacuum hose and nozzle attachment.
  3. Immerse the filter into lukewarm water (about 104°F) with a mild detergent, and then wash it and allow it to dry.
  4. Once dry, re-install the filter into the dehumidifier.
    ANDRE DS190P Pints Commercial Dehumidifier - panel1
  1.   Dehumidifier Storage & Transportation
  1. Press and hold the PUMP button for 3-5 seconds to empty the water in the pump reservoir before transportation or storage.
  2. Transport and store the dehumidifier upright.

Trouble shooting guide

Before seeking support from the service team, you can check the following troubleshooting tips:

Fault Cause Solution
Dehumidifier not working 1.The fuse is blown 2.Machine failure prompt

1.Replace the fuse; 2.Please provide the fault code and seek technicalsupport from ANDTE;
Dehumidifying effect is not obvious| 1.Air filter fouling;
2.There are obstacles in the air inlet and outlet of the dehumidifier; 3.The space is not sealed; 4.Refrigerant leakage;| 1.Clean the filter;
2.Remove obstacles;
3.Close the doors and windows, the dehumidification effect of the confined space is more obvious;
4.Please contact ANDTE for technical support;
Water leakage| 1.Machine tilt;
2.The outlet pipe is Blocked;| 1.Adjust the machine and place it horizontally;
2.Remove the access door to remove the foreign matter blocked in the pipe;
Abnormal noise| 1.The machine is not placed smoothly;
2.1s the filter blocked;| 1.Relocate the machine to a stable place;
2.Clean the filter;
Humidity always shows “1 0″(when there is a big difference from the actual humidity)| Humidity sensor failure| 1.When the “10” fault phenomenon is always displayed, the humidity is set to 10%RH, and the machine can still continue to run and be used normally;
2.Repair and replace the humidity sensor;
Humidity alwaysshows “99”(when there is a big difference from the actual humidity)| 1.The surface of the humidity sensor os condensed or wetted with water; il
2.Humidity sensor failure| 1.When the “99′ fault phenomenon is displayed all the time, the machine can still continue to dehumidify and operate normally;
2.After the machine has been running for a period of time, when the moisture on the surface of the humidity sensor dissipates,ig can automatically remove the fault and resume normal operation; 3.Repair and replace the humidity sensor;

  1. When the above fault cannot be eliminated and itis confirmed that repair s required, ploase contact the ANDTE support, please do not disassemble the machine for repair without authorization.
  2.  When the dehumidifier is running or stopped, itis normal to hear the sound of refrigerant circulating
  3. 1tis normal for hot air to be discharged from the air outlet

Safety Precautions

ANDRE DS190P Pints Commercial Dehumidifier - panel2

Service

ANDTE offers a limited 1-year free warranty on this DS190P dehumidifier, with original proof of purchase (typically you maybe only requested to offer the order number or other information to prove a genuine purchase, instead of an invoice) and where a defect has arisen, wholly or substantially, as a result of faulty manufacture, parts or workmanship during the warranty period. During the warranty period, for the damaged part, we will provide a replacement part if it can be restored to normal use by replacing parts. The warranty does not apply where damage is caused by other factors, including without limitation: Normal wear and tear; Abuse, mishandling, accident, or failure to follow operating instructions; Exposure to liquid or infiltration of foreign particles; Servicing or modifications of the product other than by ANDTE. We will try our best to inspect the dehumidifier through photos or videos to troubleshoot and ensure that we can better solve the problem for you.These are our general terms for warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms.

Warranty and Service

If you have an issue with an ANDTE product, please contact us at AndteServices@outlook.com, and we will do our best to resolve it for you.

Support Hours
24 Hours available

  • Please have your order number before contacting customer support.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals