S4A 500KG Waterproof Magnetic Lock Instructions
- June 7, 2024
- S4A
Table of Contents
S4A 500KG Waterproof Magnetic Lock Instructions
Main Parameters
- Voltage: DC12V/24V
- Current:0.5/0.25A
- Armature piate: 185mmL x 61mmW x l2mmD
- Magnet: 230mmL x 63mmW x 4OmmD
- Holding force: 1200LBS
- Operating temperature: -5°C
Diagram
Typical installation:
-
Out-swing door
-
In-swing door
Armature Plate Mounts To The Door
Attention: Please do not over tighten the screw for the armature plate,this will ensure the rubber washer maintain the required elasticity, allowing the armature plate to auto-adjust to the proper position in accordance to the magnetism.
Connection
-
DC12V: red and yellow connects +, black and green connects — (chart 1)
DC24V: red connects+ , and black connects—, ( yellow and green are in the line.) (chart 2)
DC12V Input Wiring:
Connection Method (chart 1)
DC24V Input Wiring:
Connection Method (chart 2) -
Door sensor connection method (optional) (chart 3)
If a normally open signal is needed , please connect the black and green wires.
Door sensor
Armature and magnet are properly alignet
Input voltage too low or insufficient contact between armature and magnet
(chart 3)