EBycco LCD-M5 Hand Control Panel User Manual
- June 1, 2024
- EBycco
Table of Contents
EBycco LCD-M5 Hand Control Panel
Product Information
Specifications
- Model: EBycco Electric Bike E9/ EB7Pro/ G7 Display
- Control Panel: LCD-M5 Hand Control Panel
- Out shell material: ABS
- Window material: High hardness acrylic
- Work Voltage: DC24V, 36V, 48V, 60V
- Communication protocol: UART
Product Usage Instructions
Display Functions
The display provides the following information:
- Speed display
- Power level display
- Power indicator
- Failure warning
- Total mileage
- Single mileage
- Headlight display
- Single driving time display
Control and Setting Functions
The control panel allows you to:
- Power switch control
- Headlight switch control
- 6Km/h point control
- Wheel diameter setting
- Maximum speed setting
- Idle automatic hibernation time setting
- Backlight brightness setting
- Voltage level setting
Vehicle Status Display Area
The display shows different status codes indicating the vehicle’s state:
Status Code | State | Meaning |
---|---|---|
E00 | Normal | – |
E06 | Battery under voltage | – |
Frequently Asked Questions
Q: How do I turn on the headlight manually?
A: The headlight can be manually turned on by using the control panel.
Q: How do I set the maximum speed limit?
A: You can set the maximum speed limit through the control panel settings. Navigate to the speed limit setting and input the desired value.
Dimension
Out shell Size and Material
Out shell material is ABS, Liquid crystal transparent window material is high hardness acrylic。
Transfer Ring Selection
Work Voltage and connection mode
- Work voltage : DC24V 、36V 、48V 、60V(which you can choose on the meter),the others you can customise.
- Connection mode :
Line sequence of the label connector
Table: Line sequence of the label connector table
Order of line | Color of line | Function |
---|---|---|
1 | Brown(VCC) | Instrument power cord |
2 | Green(RX) | Meter data receiving line |
3 | Black(GND) | Meter earth wire |
4 | Orange(K) | Controller power line |
5 | White(TX) | Data transmission line of instrument |
Notes: Part of the products lead wire use the waterproof connection. User cannot see the color of lead line.
Function description
- Display function Speed display, power level display, power indicator, failure warning, total mileage, single mileage, headlight display, single driving time display
- Control, setting up functions Power switch control, headlight switch control, 6Km/h point control, wheel diameter setting, maximum speed setting, idle automatic hibernation time setting, backlight brightness setting, voltage level setting
- Communication protocol:UART
All the contents of the display screen(full display in boot 1S)
introduction
Show content introduction
Headlight The instrument can be manually turned on and the brightness of the sensing environment is automatically turned on(light sensitivity support is required).
Battery power display BATTERY
Multifunctional display area
Total mileage ODO, single mileage TRIP A, single mileage TRIP B, battery current voltage VOL, current operating current CUR, remaining mileage RM; Instrument boot time TM
Vehicle mode
Walk boost mode; Cruise: constant speed cruise mode; PAS: Power file position: 0 ~ 9 adjustable;
Speed display area
Maximum speed MAX, average speed AVG Unit MPH, KM/H The meter will calculate the true speed based on the wheel diameter and signal data
Vehicle Status Display Area
Vehicle Status Code Meaning
Status Code | State Meaning | Remarks |
---|---|---|
E00 | Normal | |
E06 | Battery under voltage | |
E07 | Motor failure | |
E08 | turn malfunctioning | |
E09 | Controller failure | |
E10 | Communication reception failure | |
E11 | Communication dispatch failure |
Setting
- P01: Backlight brightness, level 1 darkest, level 3 brightest;
- P02: mileage unit, 0: KM; 1: MILE;
- P03: Voltage level: 24V, 36V, 48V, 60V, 64V default 36V;
- P04: Dormancy time: 0, not dormancy; Other numbers are dormancy times, range:
- 1-60; Unit minutes;
- P05: Help file bit: 0, 3 file mode:
- 1,5 gear mode:
- P06: Wheel diameter: unit, inch; Precision: 0.1;
- This parameter is related to the meter display speed and needs to be entered correctly;
- P07: Speed gauge magnetic steel number: range: 1-100;
- This parameter is related to the meter display speed and needs to be entered correctly;
- If it is an ordinary hub motor, direct input of magnetic steel;
- If it is a high-speed motor, it is also necessary to calculate the deceleration ratio, and the input data = the number of magnetic steel × deceleration ratio;
- For example: number of motor magnets 20, deceleration ratio 4.3: input data is: 86 = 20 × 4.3
- P08: Speed limit: range 0-100km / H, 100 means no speed limit,
- The input data here represents the maximum operating speed of the vehicle: for example, input 25, indicating that the maximum operating speed of the vehicle will not exceed 25km/h; Drive speed maintained at set value,
- Error: ± 1km/h; (Speed limit for power and steering)
- Note: The value here is based on kilometers. When the unit setting is converted from kilometers to miles, the speed value of the display interface automatically converts to the correct mile value, but the speed limit value set at this menu under the mile interface is not converted. Is inconsistent with the actual speed limit of the mile speed;
- Note: P09-P15 menu is only valid in communication state
- P09: zero start, non-zero start setting, 0: zero start; 1: Non-zero start;
- P10: The drive mode is set to 0: Power Drive(how much power is output is
- determined by the power file bit, and the switch is invalid).
- Electric drive(by turning the handle drive, when the power file bit is invalid).
- Power Drive and Electric Drive Coexistence
- P11: Help sensitivity setting range: 1-24;
- P12: Help start intensity setting range: 0-5;
- P13: Power Magnetic Steel Disk Type Setting 5, 8, 12 Magnetic Steel Types
- P14: Controller limit value set default 12A range: 1-20A
- P15: Controller undervoltage
- P16: ODO zero setting length press key 5 seconds ODO zero
- P17 :0: No enabling cruising, 1: enabling cruising; Automatic cruise optional(valid for protocol 2 only)
- P18: Display speed ratio adjustment range: 50 % ~ 150 %,
- P19: 0 power bit, 0: 0, 1: does not include 0
- P20 :0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby
Key Introduction
Press the button to use the brief Key operation is divided into short press
and long press, and combination key length press
Short press is used for rapid/frequent operations, such as the specific key
combination position as follows
- When riding, you need to modify the power/speed file, short-press
- Toggle display data for multi-function areas during cycling, short click
Single key length is mainly used to switch the mode / switch state Composite keys(long presses) are used to set parameters because the operation is complex, which can reduce errors (Short press does not make the composite key, because it is easy to trigger mistakenly, so it is too difficult to do)
Specific operational explanations:
- modify the power ratio/power file
- Let’s say the current is in power mode.
- Short press Help + 1
- Short press Help – 1
- Toggle speed display Long press, Toggle speed display
- Set / Disable 6Km/h Cruise, Switch Headlight, ODO Clear Zero Static state of vehicles, long press, Will enter 6KM/h cruise mode, let go of cruise mode; long press Turn the lights on and off; P16Menu Interface, long press five seconds, ODO clear zero。
Switching liquid crystal display
If the current display is working, long press , Will turn off the screen, instead turn on the screen
Toggle multi-function display area content
Short Can switch the value of the multifunction display area
Set Parameters
Long press + Will enter the parameter setting interface. Parameters that can be set include, Wheel diameter(in: inches), number of magnetic steel, liquid crystal brightness, low-pressure points, etc.(see settings: P01-P20); Under Settings Interface, Can be short press Set the value to perform a minimum- precision unit value operation, you can also long press,or
Continuous Fast Modify Parameters:
- Short press Switch to Next Parameter; Exit settings and save parameters. If not operated, the modified parameters will automatically exit and be saved after 8 seconds.
Note: due to the upgrade of the company’s products, the content of the product will be different from the specifications, but it will not affect your normal use.
- Company: ebycco.com
- ebyccous@gmail.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>