Technical Specifications

  • Certification: HCV
  • Material: Stainless steel
  • IP rating: IP68, IP69K
  • Load cell: PW15AH-20
  • Load cell cable: EXCT+ Blu, EXCT- Black, SIGN+ White, SENS+ Green, SENS- Grey, SIGN- Red, GND SHIELD
  • Load cell limit switch: Integrated
  • Load plate surface treatment: Stainless steel
  • Working temperature: Safe for use in various environments
  • Safe overload: Integrated overload protection
  • Break load: As per specifications
  • Linearity: High precision
  • Legal for trade resolution: Compliant
  • Maximum supply voltage: According to requirements
  • Sensitivity: Highly sensitive

Installation
Operating Environment Surface Placement
The HYGIENX platforms are designed for use in environments that comply with the hygiene requirements of the HACCP system. Place the platform on a flat, stable surface to ensure accurate measurements.

Lower Transportation Protection Bolts

  1. Lift cover away from the platform to access the platform frame.
  2. Cut cable ties carefully to release the transportation protection bolts.
  3. Locate the transportation protection bolts based on the model of your platform.

Column Mounting (optional)
If column mounting is required, refer to the detailed instructions provided in the manual for proper installation.

Feet Adjustment
To ensure stability and accurate weighing, adjust the feet of the platform as needed to level it on the surface.

Connection to the Weight Indicator
Follow the wiring code provided to correctly connect the HYGIENX platform to the weight indicator for seamless operation.

Cleaning
How to Clean
Regularly clean the platform using recommended cleaning products to maintain hygiene standards.

Recommended Cleaning Products
Use mild detergents and non-abrasive cleaners to clean the stainless steel surface of the platform.

FAQ

  • Q: Can I adjust the overload protection settings on the HYGIENX platform?
    A: No, overload protection is integrated and pre-regulated by Dini Argeo for optimal performance. Do not attempt to adjust hardware related to overload protection.

Introduction
This document contains all the information and precautions for the use of the HCV certified HYGIENX platforms produced by Dini Argeo. This certification guarantees that the product can be used in contact with food, in environments which comply with the hygiene requirements of the HACCP system. Follow this document carefully, actions not described in this manual are considered as improper use; therefore the manufacturer declines all responsibility in relation to any damage caused to things or persons and considers any kind of warranty on the product to be void. For further information please contact Dini Argeo s.r.l.

Identification

The HYGIENX platforms are identified by a label next to the serial number.

The weighing plate has a laser marking in one of its corners:

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(1\)

Technical specifications

Certification HCV (HACCP compliant verification)
Material AISI 316 stainless steel (rubber-coated feet)
IP rating IP68 / IP69K
Load cell cable Shielded 6-poles, 3 m length, 5 mm diameter
Load cell Single point, made of 17-4 PH stainless steel
Limit switch One for each corner + one central (factory set by Dini

Argeo)
Load plate surface treatment| Load plate: satin-finishing Structure: micro-painting
Working temperature| -10 °C / +50 °C
Safe overload| 150 % FS
Break load| 300 % FS
Linerity| 0,0166 % FS
Legal for trade resolution| 3000d
Maximum supply voltage| 15 VDC
Sensitivity| 2 mV/V ± 10%

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(2\)

Model| A (mm)| B (mm)| C (mm)| D (mm)| E (mm)| F (mm)
---|---|---|---|---|---|---
TSE xx HCV| 330| 230| 90 – 108| 290| 179| 30 – 45
TTE xx – HCV| 330| 330| 90 – 108| 290| 278| 30 – 45
TQE xx – HCV| 400| 400| 115 – 130| 345| 345| 30 – 45
TME xx HCV| 500| 400| 115 – 130| 445| 345| 30 – 45

To change the plate, please observe the drilling areas in the dimension technical drawing, which can be downloaded from www.diniargeo.it

Overload Protection

Overload protection is integrated into the HGX platform and regulated by Dini Argeo. Do not adjust hardware indicated in images below.

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(3\)

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(4\)

Installation

Operating Environment Surface Placement

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(5\)

Lower Transportation Protection Bolts

  1. Lift cover away from platform to access platform frame.

  2. Cut cable ties. DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(6\)

  3. Locate the transportation protection bolts.
    NOTE: TSE-HGX and TTE-HGX models have X-shaped underplates, while TQE-HGX and TME-HGX have rectangular underplates.
    The example below displays the location of protection bolts for TQE-HGX and TME-HGX platforms. DINI-ARGEO-TQE15-FOOD-Single-Cell-
Platforms-\(7\)The example below displays the location of transportation protection bolts for TSE-HGX and TTE-HGX platforms. DINI-
ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(8\)

  4. Loosen lock nut and position to top of bolt head.

  5. Twist bolt and lock nut into frame.

  6. Repeat for remaining transportation protection bolts.

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(9\)

NOTE: Install cable ties and restore transportation protection bolts to original positions before transport.

Column Mounting (optional)

Attach platform to column with four M6 hex bolts, steel M6 washers, spacers and plastic washers.
Note:
The TME-HGX and TSE-HGX platforms provide two mounting positions, this procedure shows examples of both positions. Be aware, the alternate mounting position is only available to TME-HGX and TSE-HGX platforms.
The example below displays the platform in the standard mounting position.

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(10\)

The example below displays the platform in the alternate mounting position.

Attach the indicator to column with provided washers and nuts.

Feet Adjustment

  1. Screw or unscrew the feet to lower or raise the corners of the platform until the bubble centres in the black circle.
  2. When the adjustment is complete, position the bushing so that the thread of the foot is not visible.

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(13\)

Connection to the Weight Indicator

DINI-ARGEO-TQE15-FOOD-Single-Cell-Platforms-\(14\)

Cleaning

To mantain the platform in optimal condition, special attention must be paid to the cleanliness of its surfaces. In the food industry, organic residues accumulating on surfaces can cause rust. This rust is created by oxidation of the ferrous component of the residue and can affect the surface treatment of the platform causing unsightly marks. Clean the table at the end of each working day, following the “How to clean” section. If the table is used in direct contact with saltiness (fish processing or sale) or salt (dairies, milk processing), it must be rinsed with fresh water at the end of each working day. If, despite careful cleaning, small traces of rust appear on the surfaces, they can be easily removed using the product SSCLEANER described in the “Recommended cleaning products” section. Refer to the stainless steel corrosion tables (annex QSG_SS_CORROSION) to find out which substances can damage the platform the most.

How to clean
In order to keep the product in good condition, it is essential that the following cleaning instructions are followed:

  1. Use a pressure washer to remove large residue.
  2. If necessary, apply a stainless steel degreasing agent.
  3. Remove product residue with running water.
  4. Dry with paper towels or a dry cloth. It is also recommended
  5. Apply a stainless steel protective spray to the load cell.

Recommended cleaning products
Code Dini Argeo “SSCLEANER”: Detergent that combines the actions of cleaning, polishing and surface protection.
Removes organic residues, ink stains, rust, encrustations, salt residues, oil and grease deposits. Does not scratch or damage surfaces. Not corrosive and does not harm the skin (pH 10.3 ± 0.5). Avoid eye contact.

HEAD OFFICE

  • Via Della Fisica, 20
  • 41042 Spezzano di Fiorano, Modena – Italy
  • Tel. +39 0536 843418
  • Fax +39 0536 843521

SERVICE ASSISTANCE

  • Via Dell’Elettronica, 15
  • 41042 Spezzano di Fiorano, Modena – Italy
  • Tel. +39 0536 921784
  • Fax +39 0536 926654

www.diniargeo.com