Replacing Boards.
Installing a New Board
If one of the boards becomes mechanically or electrically faulty, a replacement board is needed. The set parameters (timers, learned floor, etc.) can be retained after the board is replaced.
Retain Parameters for a Replaced MR Board
The following procedure describes how to transfer the parameters from the CT
board to the replaced MR board.
- Turn off power to the controller.
- Install and replace the MR SRU board and reattach the connector terminals.
- Turn on DIP 5B and DIP 7A.
- Power up the Controller.
- On power up, the MR board displays SYNC IN PROGRESS (the car will be Out of Service).
- When complete, SYNC COMPLETE is displayed.
- Turn off the controller.
- Turn off DIP 5B.
- Turn on the controller and the car resumes normal operation.
Retain Parameters for a Replaced CT or COP Board
The following procedure describes how to transfer the parameters from the MR
board to the replaced CT or COP board.
-
Remove power from the controller.
-
Disconnect the connectors and remove the CT or COP board.
-
Install and replace the CT or COP board and reattach the connector terminals.
NOTE: Ensure all DIP switches are correct. -
Turn the CT/COP switch to either the CT or COP that is being replaced.
-
NOTE: The switch is located on the upper right corner of the board.
-
Remove LOTO and apply power to the controller.
-
The Sync Process automatically begins due to a checksum that consistently compares parameters between all three boards.
NOTE: There is no SYN IN PROGRESS displayed. -
When complete, the CT/COP board is in normal operation with all parameters retained.