Product Specifications:

  • Product Name: Safety Gloves
  • Model: ART. 119.7000
  • Quantity: 6 pairs
  • Certification: CAT. II
  • Sizes Available: 8/M, 9/L, 10/XL, 11/2XL
  • Standard: EN ISO 21420:2020

Product Usage Instructions

Choosing the Correct Size:
Refer to the size chart below to select the appropriate glove size based on your hand measurements:

Glove Size EN ISO 21420 Size
M 8
L 9
XL 10
2XL 11

Putting on the Gloves:
Ensure your hands are clean and dry before wearing the gloves.

  1. Insert your fingers into the glove fingers one by one.
  2. Pull up the glove gently over your hand and wrist.
  3. Adjust the fit to ensure comfort and maximum grip.

Care and Maintenance:
Proper care will extend the life of your safety gloves.

Follow these tips:

  • Regularly inspect for signs of wear or damage.
  • Clean as needed following manufacturer’s instructions.
  • Store in a cool, dry place away from direct sunlight.

Frequently Asked Questions (FAQ):

  1. Q: Can these gloves be washed in a washing machine?
    A: It is recommended to hand wash these gloves with mild soap and water to maintain their quality.

  2. Q: Are these gloves suitable for use in extreme temperatures?
    A: These gloves are designed to provide protection in normal working conditions. Extreme temperatures may affect their performance.

  3. Q: How do I know if I need a different size?
    A: If the gloves feel too tight, restricting movement, or too loose, impeding grip, consider trying a different size based on the size chart.

SIZE 8/M (EN ISO 21420:2020)

  • 1/A = minimum requirement
  • 4/5/F = maximum requirement
  • X – not tested

ASTM F2878-2010 – Level 5
EN ISO 21420:2020

GRANBERG-1197000-Needle-Resistant-Gloves-6

The results are taken from the palm area of the gloves. The protection level increases with performance class.
This product is classed as Category II Personal Protective Equipment (PPE) according to PPE Regulation (EU) 2016/425 and has been shown to comply with this Regulation through the Harmonised Standards EN 388:2016+A1:2018, EN ISO 21420:2020.

Notified Body responsible for certification (Module B):
Name: SATRA Technology Europe Ltd.
Address: Bracetown Business Park, Clonee, Dublin D15 YN2P, Republic of Ireland. Notified Body No: 2777
Declaration of Conformity can be obtained from https://www.granberg.no/catalog/119.7000

GRANBERG-1197000-Needle-Resistant-Gloves-2

Wear the products of suitable sizes to provide optimal level of protection and maximum grip. User must only choose the glove fitting the size of her/his hand.

User Manual issue date: 23.01.2024
Granberg AS, Bjoavegen 1442, NO-5584 Bjoa, NORWAY
Needlestick resistant gloves, black polyester liner fully dipped in black foam latex coating. Needlestick resistant material in the palm, fingers and fingertips provides protection from needle hazards and increases cut protection. ASTM F2878-2010 Hypodermic Needle (25 gauges) Puncture Resistant is level 5 and ANSI/ISEA 105-2016 Level A9 cut resistance- highest level. Recommended to work with waste handing, recycling, sharp objects etc.
Storage/Transport: The gloves are first packed in plastic bags which are subsequently packed in cardboard boxes for transport and storage. Granberg recommends storing unused gloves in original packaging. Prevent direct sunlight.
Maintenance/Cleaning: Both new and used gloves should be inspected before use, and before putting them on to make sure that there is no damage to them. If in doubt, discard the gloves and select a new pair. Leaving the gloves in a contaminated condition may cause a deterioration of quality. Cleaning or disinfecting the gloves may also negatively affect quality. The performance characteristics of gloves that have been worn or cleaned/disinfected/laundered may differ from the performance levels declared. Gloves can only be cleaned with damp cloth, but it will not stop permeation processes. The gloves are not washable.
Obsolescence: When stored as recommended, unused gloves will not suffer any change in their mechanical properties for up to three years from the date of manufacture. Service life depends on application and maintenance and cannot be specified. It is the responsibility of the user to ascertain the suitability of the gloves for the user’s tasks.
Donning/Doffing: Select the right size glove for your hand. Hold the glove by the cuff with one hand. Align the glove thumb with your other hand thumb and slide your hand into the glove, one finger into each finger. Pull by the glove cuff and align fingers into the right position. Use the same procedure for the other hand. If gloves are not contaminated, pull by the fingertips to doff the gloves. If gloves are contaminated, hold the glove cuff and pull toward the finger until the gloves come off.
Please note: Inspect the gloves for damage before use. The gloves shall not be worn when there is a risk of entanglement with moving parts of machines. Gloves containing latex may cause allergic reactions in case of hypersensitivity to latex. Seek medical advice if applicable. None of the raw materials used in glove, or process of manufacturing it, are known to be harmful to the user. These gloves are intended to protect hands in working environment in accordance with EN 388:2016+A1:2018, ASTM F2878-2010 and EN ISO 21420:2020. This product complies with ANSI/ISEA 105-2016. It is the responsibility of the user to evaluate and determine risks based on the intended application. The gloves should only be used for applications declared suitable by the manufacturer. Risk should be evaluated keeping in mind the protection levels and the harmonized standards on which gloves are tested. The results of the tests should help in glove selection, however it must be understood that actual conditions of use cannot be simulated and it is the responsibility of the user, not the manufacturer, to determine glove suitability to the intended use. Further information may be obtained from manufacturer.

SIZE 9/L (EN ISO 21420:2020)

  • 1/A = minimum requirement
  • 4/5/F = maximum requirement
  • X – not tested

ASTM F2878-2010 – Level 5
EN ISO 21420:2020

GRANBERG-1197000-Needle-Resistant-Gloves-6

The results are taken from the palm area of the gloves.
The protection level increases with performance class.
ASTM F2878-2010 – Level 5
This product is classed as Category II Personal Protective Equipment (PPE) according to PPE Regulation (EU) 2016/425 and has been shown to comply with this Regulation through the Harmonised Standards EN 388:2016+A1:2018, EN ISO 21420:2020.

Notified Body responsible for certification (Module B):
Name: SATRA Technology Europe Ltd.
Address: Bracetown Business Park, Clonee, Dublin D15 YN2P, Republic of Ireland. Notified Body No: 2777
Declaration of Conformity can be obtained from https://www.granberg.no/catalog/119.7000

GRANBERG-1197000-Needle-Resistant-Gloves-8

Wear the products of suitable sizes to provide optimal level of protection and maximum grip. User must only choose the glove fitting the size of her/his hand.

User Manual issue date: 23.01.2024
Granberg AS, Bjoavegen 1442, NO-5584 Bjoa, NORWAY
Needlestick resistant gloves, black polyester liner fully dipped in black foam latex coating. Needlestick resistant material in the palm, fingers and fingertips provides protection from needle hazards and increases cut protection. ASTM F2878-2010 Hypodermic Needle (25 gauges) Puncture Resistant is level 5 and ANSI/ISEA 105-2016 Level A9 cut resistance- highest level. Recommended to work with waste handing, recycling, sharp objects etc.
Storage/Transport: The gloves are first packed in plastic bags which are subsequently packed in cardboard boxes for transport and storage. Granberg recommends storing unused gloves in original packaging. Prevent direct sunlight.
Maintenance/Cleaning: Both new and used gloves should be inspected before use, and before putting them on to make sure that there is no damage to them. If in doubt, discard the gloves and select a new pair. Leaving the gloves in a contaminated condition may cause a deterioration of quality. Cleaning or disinfecting the gloves may also negatively affect quality. The performance characteristics of gloves that have been worn or cleaned/disinfected/laundered may differ from the performance levels declared. Gloves can only be cleaned with damp cloth, but it will not stop permeation processes. The gloves are not washable.
Obsolescence: When stored as recommended, unused gloves will not suffer any change in their mechanical properties for up to three years from the date of manufacture. Service life depends on application and maintenance and cannot be specified. It is the responsibility of the user to ascertain the suitability of the gloves for the user’s tasks.
Donning/Doffing: Select the right size glove for your hand. Hold the glove by the cuff with one hand. Align the glove thumb with your other hand thumb and slide your hand into the glove, one finger into each finger. Pull by the glove cuff and align fingers into the right position. Use the same procedure for the other hand. If gloves are not contaminated, pull by the fingertips to doff the gloves. If gloves are contaminated, hold the glove cuff and pull toward the finger until the gloves come off.
Please note: Inspect the gloves for damage before use. The gloves shall not be worn when there is a risk of entanglement with moving parts of machines. Gloves containing latex may cause allergic reactions in case of hypersensitivity to latex. Seek medical advice if applicable. None of the raw materials used in glove, or process of manufacturing it, are known to be harmful to the user. These gloves are intended to protect hands in working environment in accordance with EN 388:2016+A1:2018, ASTM F2878-2010 and EN ISO 21420:2020. This product complies with ANSI/ISEA 105-2016. It is the responsibility of the user to evaluate and determine risks based on the intended application. The gloves should only be used for applications declared suitable by the manufacturer. Risk should be evaluated keeping in mind the protection levels and the harmonized standards on which gloves are tested. The results of the tests should help in glove selection, however it must be understood that actual conditions of use cannot be simulated and it is the responsibility of the user, not the manufacturer, to determine glove suitability to the intended use. Further information may be obtained from manufacturer.

SIZE 10/XL (EN ISO 21420:2020)

  • 1/A = minimum requirement
  • 4/5/F = maximum requirement
  • X – not tested

ASTM F2878-2010 – Level 5
EN ISO 21420:2020

GRANBERG-1197000-Needle-Resistant-Gloves-15

The results are taken from the palm area of the gloves. The protection level increases with performance class.
ASTM F2878-2010 – Level 5
This product is classed as Category II Personal Protective Equipment (PPE) according to PPE Regulation (EU) 2016/425 and has been shown to comply with this Regulation through the Harmonised Standards EN 388:2016+A1:2018, EN ISO 21420:2020.

Notified Body responsible for certification (Module B):
Name: SATRA Technology Europe Ltd.
Address: Bracetown Business Park, Clonee, Dublin D15 YN2P, Republic of Ireland. Notified Body No: 2777
Declaration of Conformity can be obtained from https://www.granberg.no/catalog/119.7000

GRANBERG-1197000-Needle-Resistant-Gloves-12

Wear the products of suitable sizes to provide optimal level of protection and maximum grip. User must only choose the glove fitting the size of her/his hand.

User Manual issue date: 23.01.2024
Granberg AS, Bjoavegen 1442, NO-5584 Bjoa, NORWAY
Needlestick resistant gloves, black polyester liner fully dipped in black foam latex coating. Needlestick resistant material in the palm, fingers and fingertips provides protection from needle hazards and increases cut protection. ASTM F2878-2010 Hypodermic Needle (25 gauges) Puncture Resistant is level 5 and ANSI/ISEA 105-2016 Level A9 cut resistance- highest level. Recommended to work with waste handing, recycling, sharp objects etc.
Storage/Transport: The gloves are first packed in plastic bags which are subsequently packed in cardboard boxes for transport and storage. Granberg recommends storing unused gloves in original packaging. Prevent direct sunlight.
Maintenance/Cleaning: Both new and used gloves should be inspected before use, and before putting them on to make sure that there is no damage to them. If in doubt, discard the gloves and select a new pair. Leaving the gloves in a contaminated condition may cause a deterioration of quality. Cleaning or disinfecting the gloves may also negatively affect quality. The performance characteristics of gloves that have been worn or cleaned/disinfected/laundered may differ from the performance levels declared. Gloves can only be cleaned with damp cloth, but it will not stop permeation processes. The gloves are not washable.
Obsolescence: When stored as recommended, unused gloves will not suffer any change in their mechanical properties for up to three years from the date of manufacture. Service life depends on application and maintenance and cannot be specified. It is the responsibility of the user to ascertain the suitability of the gloves for the user’s tasks.
Donning/Doffing: Select the right size glove for your hand. Hold the glove by the cuff with one hand. Align the glove thumb with your other hand thumb and slide your hand into the glove, one finger into each finger. Pull by the glove cuff and align fingers into the right position. Use the same procedure for the other hand. If gloves are not contaminated, pull by the fingertips to doff the gloves. If gloves are contaminated, hold the glove cuff and pull toward the finger until the gloves come off.
Please note: Inspect the gloves for damage before use. The gloves shall not be worn when there is a risk of entanglement with moving parts of machines. Gloves containing latex may cause allergic reactions in case of hypersensitivity to latex. Seek medical advice if applicable. None of the raw materials used in glove, or process of manufacturing it, are known to be harmful to the user. These gloves are intended to protect hands in working environment in accordance with EN 388:2016+A1:2018, ASTM F2878-2010 and EN ISO 21420:2020. This product complies with ANSI/ISEA 105-2016. It is the responsibility of the user to evaluate and determine risks based on the intended application. The gloves should only be used for applications declared suitable by the manufacturer. Risk should be evaluated keeping in mind the protection levels and the harmonized standards on which gloves are tested. The results of the tests should help in glove selection, however it must be understood that actual conditions of use cannot be simulated and it is the responsibility of the user, not the manufacturer, to determine glove suitability to the intended use. Further information may be obtained from manufacturer.

SIZE 11/2XL (EN ISO 21420:2020)

  • 1/A = minimum requirement
  • 4/5/F = maximum requirement
  • X – not tested

ASTM F2878-2010 – Level 5
EN ISO 21420:2020

GRANBERG-1197000-Needle-Resistant-Gloves-15

The results are taken from the palm area of the gloves. The protection level increases with performance class.
ASTM F2878-2010 – Level 5
This product is classed as Category II Personal Protective Equipment (PPE) according to PPE Regulation (EU) 2016/425 and has been shown to comply with this Regulation through the Harmonised Standards EN 388:2016+A1:2018, EN ISO 21420:2020.

Notified Body responsible for certification (Module B):
Name: SATRA Technology Europe Ltd.
Address: Bracetown Business Park, Clonee, Dublin D15 YN2P, Republic of Ireland. Notified Body No: 2777
Declaration of Conformity can be obtained from https://www.granberg.no/catalog/119.7000

GRANBERG-1197000-Needle-Resistant-Gloves-16

Wear the products of suitable sizes to provide optimal level of protection and maximum grip. User must only choose the glove fitting the size of her/his hand.

User Manual issue date: 23.01.2024
Granberg AS, Bjoavegen 1442, NO-5584 Bjoa, NORWAY
Needlestick resistant gloves, black polyester liner fully dipped in black foam latex coating. Needlestick resistant material in the palm, fingers and fingertips provides protection from needle hazards and increases cut protection. ASTM F2878-2010 Hypodermic Needle (25 gauges) Puncture Resistant is level 5 and ANSI/ISEA 105-2016 Level A9 cut resistance- highest level. Recommended to work with waste handing, recycling, sharp objects etc.
Storage/Transport: The gloves are first packed in plastic bags which are subsequently packed in cardboard boxes for transport and storage. Granberg recommends storing unused gloves in original packaging. Prevent direct sunlight.
Maintenance/Cleaning: Both new and used gloves should be inspected before use, and before putting them on to make sure that there is no damage to them. If in doubt, discard the gloves and select a new pair. Leaving the gloves in a contaminated condition may cause a deterioration of quality. Cleaning or disinfecting the gloves may also negatively affect quality. The performance characteristics of gloves that have been worn or cleaned/disinfected/laundered may differ from the performance levels declared. Gloves can only be cleaned with damp cloth, but it will not stop permeation processes. The gloves are not washable.
Obsolescence: When stored as recommended, unused gloves will not suffer any change in their mechanical properties for up to three years from the date of manufacture. Service life depends on application and maintenance and cannot be specified. It is the responsibility of the user to ascertain the suitability of the gloves for the user’s tasks.
Donning/Doffing: Select the right size glove for your hand. Hold the glove by the cuff with one hand. Align the glove thumb with your other hand thumb and slide your hand into the glove, one finger into each finger. Pull by the glove cuff and align fingers into the right position. Use the same procedure for the other hand. If gloves are not contaminated, pull by the fingertips to doff the gloves. If gloves are contaminated, hold the glove cuff and pull toward the finger until the gloves come off.
Please note: Inspect the gloves for damage before use. The gloves shall not be worn when there is a risk of entanglement with moving parts of machines. Gloves containing latex may cause allergic reactions in case of hypersensitivity to latex. Seek medical advice if applicable. None of the raw materials used in glove, or process of manufacturing it, are known to be harmful to the user. These gloves are intended to protect hands in working environment in accordance with EN 388:2016+A1:2018, ASTM F2878-2010 and EN ISO 21420:2020. This product complies with ANSI/ISEA 105-2016. It is the responsibility of the user to evaluate and determine risks based on the intended application. The gloves should only be used for applications declared suitable by the manufacturer. Risk should be evaluated keeping in mind the protection levels and the harmonized standards on which gloves are tested. The results of the tests should help in glove selection, however it must be understood that actual conditions of use cannot be simulated and it is the responsibility of the user, not the manufacturer, to determine glove suitability to the intended use. Further information may be obtained from manufacturer.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals