CRESTRON UC-M70-NC-T Flex Tabletop Large Room Conference System Installation Guide
- June 1, 2024
- CRESTRON
Table of Contents
CRESTRON UC-M70-NC-T Flex Tabletop Large Room Conference System
Important Information
The UC-M70-NC-T Crestron Flex tabletop conferencing system provides a large room conference solution for use with Microsoft Teams® Rooms software. It supports single or dual video displays and features a Crestron Flex tabletop conference device and UC bracket assembly.
Minimum Requirements:
- A Microsoft Teams certified USB Camera (not included).
- A video display (not included) connected to the UC Engine. A second display is optional.
- A Microsoft Teams Rooms provisioned account (not included).
In the Box
Tabletop Conference Device
1 | Tabletop Conference Device, Microsoft Teams video (6510716) |
---|---|
1 | Cable, CAT5e, RJ-45 – RJ-45, 12 ft (3.7 m) (2033988) |
1 | Cable Retention Plate (2047908) |
3 | Tie Wrap (2047935) |
UC Bracket Assembly
1| UC Bracket Assembly with UC Engine and HDMI® content ingest (UC-
BRKT-200-S-T-ASSY, 6512689)
---|---
2| Anchor, Drywall, Plastic, 3/8 in. x 1/2 in. (9.5 mm x 12.7 mm) (2052565)
1| Key, Anchor (4529654)
2| Screw, 8-AB x 1-1/2 in. (38.1 mm), Pan Head, Combo (2052567)
4| Tie Wrap (2047935)
Additional Items
1 | Microphone pod (6508084) |
---|---|
1 | Cable, CAT6a, RJ-45 – RJ-45, 20 ft (6.1 m) (6507640) |
1 | Cable, CAT5e, RJ-45 – RJ-45, 7 ft (2.1 m) (6509924) |
1 | Cable, DisplayPort™ to HDMI, 6 ft (1.8 m) (6508282) |
1 | Cable, HDMI, 20 ft (6.1 m) (6503567) |
1 | Cable, HDMI, 6 ft (1.8 m) (6512150) |
1 | Cable, USB 2.0, A – Micro-B, 6 ft (1.8 m) (6510947) |
1 | Cable, USB Extension, USB Type A Male-to-Female, 15 ft (4.6 m) (6508260) |
1 | Power supply (6500187) |
Mount Devices
Mount the UC Bracket Assembly
Mount the UC Bracket Assembly to VESA® compliant display devices, a wall, or
other building structure. Anchors and screws are supplied for installation on
walls with 3/8 in. (9.5 mm) to 3/4 in. (19 mm) thickness.
CAUTION: Preinstalled screws may protrude from the back of the UC Bracket Assembly. Exercise caution when handling the UC Bracket Assembly to avoid scratching or damaging surfaces.
NOTE: The integrated cable tie wraps are reusable. Avoid damaging the cable tie wraps.
Install the Cable Retention Plate
The included cable retention plate provides tie-down points for cables that
connect to the Crestron® conference device.
Remove the adhesive backing from the cable retention plate and install the
plate on the underside of the conference device as shown in the following
diagram. Ensure the cable retention plate is firmly attached before securing
cables.
CAUTION: When turning over the device, place the device on a soft surface to avoid damage.
NOTE: If a swivel mount kit (CCS-UCA-
SMK) is to be used, use the cable
retention bracket included with the swivel mount kit as described in the CCS-
UCA-SMK DO Guide (Doc. 7882).
Connect
Identify the UC Bracket Assembly
The UC Bracket Assembly is available in two models. Identify the model
included with your Crestron Flex system. Tap or click the corresponding image
below to navigate to the appropriate connection instructions.
UC Bracket Assembly with HD-CONV-USB-200
UC Bracket Assembly with HD-CONV-USB-300
System Overview
For UC Bracket Assembly with HD-CONV-USB-200
When connections are complete, the system appears as shown below. Refer to
Make Connections for detailed connection instructions.
For UC Bracket Assembly with HD-CONV-USB-300
When connections are complete, the system appears as shown below. Refer to
Make Connections for detailed connection instructions.
Make Connections
NOTE: For reference, the UC Bracket Assembly is shown with the HD-CONV- USB-200 in the following connection diagrams. Unless otherwise indicated in this guide, the connections remain the same for the UC Bracket Assembly with HD-CONV-USB-200 and HD CONV-USB-300.
-
Make UC Engine connections as shown in the following illustrations. The conference device can communicate with the UC Engine over a direct connection or a network connection. Select one of the connection types as described below.
-
Make a direct connection for simple installation and setup. Only use the direct connect adapter to connect the conference device to the UC Engine. Do not use the direct connect adapter to connect the UC Engine to the network.
Direct Connection
-
Make a network connection if the system is to be managed by the XiO Cloud® service.
NOTE: When a network connection is used, disconnect the direct connect adapter from the UC Engine.
Network Connection
-
-
Connect displays to the UC Engine.
-
Connect a camera (not included) to the UC Engine as shown in the image below. Do not connect the camera to any of the other USB ports.
-
Connect a laptop to the HD-CONV-USB-200 or HD-CONV-USB-300.
-
Bundle the cables to the bracket assembly with the integrated cable tie wraps. The cable tie wraps are reusable.
Bundle Cables
Bundle the cables together and use a provided tie wrap to secure the bundle to
one of the positions on the cable retention plate at the rear of the device.
Avoid bundling power and data cables together.
Configure
Apply Power
Press the power button on the bottom of the UC Engine and apply power to all of the other devices in the system. The conference device will display its IP address.
Configure the Conference Device
NOTE: If a Direct Connection was made between the conference device and the UC Engine, skip to Configure the System.
-
On a computer, enter the IP address displayed on the conference device into a web browser.
NOTES:- The device and computer must be on the same network switch and VLAN.
- A login with administrative rights for the device is required.
-
Log in to the device and navigate to DEVICE > Applications.
-
Enter the following information in the appropriate fields:
-
Teams Video PC Address: Enter the IP address or hostname of the UC Engine.
NOTE: The hostname is printed on a label affixed to the UC Engine. -
Teams Video PC Port: By default, port number 49500 is used. If a different port number has been configured on the UC Engine, enter that port number instead.
-
Teams Video Username: Enter the login username for the UC Engine. (The default username is “admin”.)
-
Teams Video Password: Enter the login password for the UC Engine. (The default password is “sfb”.)
-
-
Select Save Changes.
Configure the System
Use the conference device and your Microsoft Teams credentials to configure the UC Engine. For detailed information on deploying Microsoft Teams Rooms, refer to the Microsoft Teams Rooms documentation.
Visit the Product Page
Scan the QR code to visit the product page.
UC-M70-NC-T
www.crestron.com/model/6513793
Additional Information
Original Instructions
The U.S. English version of this document is the original instructions.
All other languages are a translation of the original instructions.
Crestron product development software is licensed to Crestron dealers and
Crestron Service Providers (CSPs) under a limited nonexclusive,
nontransferable Software Development Tools License Agreement. Crestron product
operating system software is licensed to Crestron dealers, CSPs, and end-users
under a separate End-User License Agreement. Both of these Agreements can be
found on the Crestron website at
www.crestron.com/legal/software_license_agreement.
The product warranty can be found at
www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at
www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specific
information, visit
www.crestron.com/opensource.
Crestron, the Crestron logo and Xi O Cloud are either trademarks or registered
trademarks of Crestron Electronics, Inc. in the United States and/or other
countries.
HDMI is either a trademark or registered trademark of HDMI Licensing LLC in
the United States and/or other countries. Microsoft Teams is either a
trademark or registered trademark of Microsoft Corporation in the United
States and/or other countries. DisplayPort and VESA are either trademarks or
registered trademarks of Video Electronics Standards Association in the United
States and/or other countries. Other trademarks, registered trademarks, and
trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Crestron disclaims any
proprietary interest in the marks and names of others. Crestron is not
responsible for errors in typography or photography.
©2024 Crestron Electronics, Inc.
Doc. 9473A
01/25/24
References
- Patents [Crestron Electronics, Inc.]
- Software License Agreements (Embedded Software and Software Tools) [Crestron Electronics, Inc.]
- UC-M70-NC-T [Crestron Electronics, Inc.]
- Open Source Software [Crestron Electronics, Inc.]
- Standard Terms & Conditions and Warranties [Crestron Electronics, Inc.]
- Microsoft Teams Rooms - Microsoft Teams | Microsoft Learn
- Patents [Crestron Electronics, Inc.]
- Software License Agreements (Embedded Software and Software Tools) [Crestron Electronics, Inc.]
- CCS-UCA-SMK [Crestron Electronics, Inc.]
- UC-M70-NC-T [Crestron Electronics, Inc.]
- UC-M70-NC-Z [Crestron Electronics, Inc.]
- Standard Terms & Conditions and Warranties [Crestron Electronics, Inc.]