PHILIPS-SM345C-UV-C-Disinfection-Upper-Air-CM-PRODUCT-
IMAGE

Specifications

  • Product Name: UV-C disinfection upper air CM
  • Model: SM345C C 4xTUV PLS 9W HFM
  • Power Consumption: 36 W
  • Input Voltage: 220 to 240 V
  • Frequency: 50 or 60 Hz
  • Safety Class: I
  • Dimensions: 595 x 198 x 595 mm
  • Material: Aluminum housing, aluminum reflector, white and black optic material
  • Ingress Protection: IP20 (Finger-protected)
  • UV-C Radiation: Yes

Product Usage Instructions

Installation

  1. Identify a suitable location for mounting the UV-C disinfection upper air CM.
  2. Ensure the area is clear and accessible for installation.
  3. Mount the device securely using the provided mounting hardware.

Operation

  1. Connect the UV-C disinfection upper air CM to a power source within the specified voltage range.
  2. Turn on the device using the mains outlet socket.
  3. Avoid direct exposure to UV-C radiation while the device is in operation.

Maintenance

  1. Regularly clean the device’s housing and reflector to maintain optimal performance.
  2. Replace the light sources as needed according to the manufacturer’s recommendations.

Frequently Asked Questions (FAQ)

  • Q: Is the UV-C disinfection upper air CM dimmable?
    A: No, the product is not dimmable.

  • Q: What is the warranty period for the UV-C disinfection upper air CM?
    A: The product comes with a warranty period of 1 year.

  • Q: Can the UV-C disinfection upper air CM be used for random switching?
    A: Yes, the product is suitable for random switching.

UV-C disinfection upper air CM

  • SM345C C 4xTUV PLS 9W HFM
  • 4, 36 W, 220 to 240 V, 50 or 60 Hz, Safety class I, Finger- protected, 0.2 J standard
  • Philips UV-C disinfection upper air ceiling mounted is designed to be installed on false ceilings for the disinfection of air in a wide range of applications. Optimized for low ceiling heights, the UV-C rays are distributed at device level and above. The beam of UV-C rays is controlled by specific reflectors and the louvre design. This allows for the disinfection of the air in a space, while ensuring that day-to-day business activities can continue underneath the area where the device is active.

Warnings and Safety

  • DANGER: Risk Group 3 UV product according IEC 62471. Like any disinfection system, UV-C lamps and devices must be installed and used in the correct way. Direct exposure to UV-C can be dangerous and result in a sunburn-like reaction to the skin and serious damage to the cornea. As UV-C is invisible to the eye, the UV-C upper air device must be used and installed in strict accordance with the requirements set forth in the user manual and/or the mounting instructions.
  • Philips UV-C luminaires systems must only be sold and installed by professionals according to our stringent safety and legal requirements. Our UV-C products are not meant to be used in applications or activities which may cause and/or lead to death, personal injury and/or damage to the environment.
  • The UV-C upper air device effectiveness in the deactivation of certain viruses, bacteria, protozoa, fungi or other harmful micro-organisms is as described above under the heading “Benefits”. Signify and its group of companies do not promise or warrant that the use of the UV-C upper air devices will protect any user from or prevent infection and/or contamination with any viruses, bacteria, protozoa, fungi, illness or disease. The UV-C upper air devices are not approved and/or certified as a medical device by the FDA and/or any other regulatory body. As such, the UV-C upper air devices are not intended for and must not be used to disinfect medical devices and/or for medical purposes. In addition to and without limitation of any exclusions or limitations of liability of Signify and its group of companies as set forth in any agreement for the sale, distribution or otherwise making available of the UV-C upper air devices, Signify and its group of companies shall have no responsibility or liability whatsoever for any claim or damage that may arise from or relate to any use of the UV-C upper air devices outside of their intended use or contrary to their installation and operation instructions, each as described in this document, the user manuals and/or the mounting instructions.

Product data

Product data|
---|---
General Information| | | Mounting device| –
Number of gear units| 4 units| | Overall length| 595 mm
Gear| HFM [HF Matchbox]| | Overall width| 198 mm
CE mark| CE mark| | Overall height| 595 mm
Warranty period| 1 years| | Dimensions (Height x Width x Depth)| 595 x 198 x 595 mm
Flammability mark| –| | |
ENEC mark| –| | Approval and Application|
Glow-wire test| –| | Ingress protection code| IP20 [Finger- protected]
EU RoHS compliant| Yes| | Mech. impact protection code| IK02 [0.2 J standard]
| | | Protection class IEC| Safety class I
Light Technical| | | Photobiological risk| Photobiological risk group 3 @200mm to
Number of light sources| 4| | | EN62778
Beam angle of light source| – degree(s)| | |
Optic type| –| | UV|
Luminaire light beam spread| –| | UV-C radiation| 8.8 W
| | | UV-C irradiance defined at 2m| 11.4 µW/cm²
Operating and Electrical| | | UV-C irradiance defined at 0.2m| 137.2 µW/cm²
Input Voltage| 220 to 240 V| | |
Line Frequency| 50 or 60 Hz| | Initial Performance (IEC Compliant)|
Inrush current| 13 A| | Power consumption tolerance| +/-10%
Inrush time| 0.111 ms| | |
Power Consumption| 36 W| | Application Conditions|
Power Factor (Fraction)| 0.6| | Performance ambient temperature Tq| 25 °C
Connection| Mains outlet socket| | Maximum dim level| Not applicable
Cable| Cable 0.2 m without plug| | Suitable for random switching| No
Number of products on MCB of 16 A type B| 70| | |
| | | Product Data|
Temperature| | | Order product name| SM345C C 4xTUV PLS 9W HFM
Ambient temperature range| +10 to +40 °C| | Full product name| SM345C C 4xTUV PLS 9W HFM
| | | Full product code| 871951452757700
Controls and Dimming| | | Order code| 52757700
Dimmable| No| | Material Nr. (12NC)| 911401580671
Control interface| –| | Numerator Quantity Per Pack| 1
| | | EAN/UPC – Product/Case| 8719514527577
Mechanical and Housing| | | Numerator Packs per outer box| 1
Housing Material| Aluminum| | EAN/UPC – Case| 8719514527577
Reflector material| Aluminum| | |
Optic material| –| | |
Housing Color| White and black| | |

Dimensional drawing

  • © 2023 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.
  • www.lighting.philips.com
  • 2023, December 7 – data subject to change

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals