PHILIPS DN390B Green Space G6 Downlight User Guide

June 1, 2024
Philips

PHILIPS DN390B Green Space G6 Downlight

Specifications

  • Product: GreenSpace G6 Downlight
  • Model Number: 444170264781
  • Indoor Use Only
  • Compliance: IEC, AS/NZ60598
  • IP Rating: IP20 (IP54 for Optical Surface)

Product Usage Instructions

Mounting Instructions

  1. Ensure the downlight is suitable for indoor use only.
  2. Refer to the provided cut-off dimensions and cut-out sizes for installation.
  3. Connect power cable and PSD signal cable as specified.
  4. Place the terminal box into the ceiling after connecting the cables.
  5. Ensure proper clearance distances are maintained to prevent overheating or fire risks.

Installation

  1. Connect the power cable and PSD signal cable to the terminal box.
  2. Place the terminal box into the ceiling securely.
  3. Ensure a minimum height clearance to building elements as specified.
  4. Switch off before inserting the socket.

Product Safety

Warning: Do not touch the optical area to avoid damage or injury. Follow all installation and safety guidelines provided in the manual.

FAQ

  • Q: Can this downlight be used outdoors?
    A: No, this downlight is suitable for indoor use only.

  • Q: What is the IP rating of the product?
    A: The product has an IP20 rating, with IP54 for the Optical Surface.

  • Q: How should I connect the cables for installation?
    A: Connect the power cable and PSD signal cable to the terminal box as instructed in the manual before placing it in the ceiling.

GreenSpace G6 Downlight

Mounting instruction

PHILIPS-DN390B-Green-Space-G6-Downlight- \(1\)

Type| Voltage (v)| Frequency(Hz)| CCT| Reflector| IP| Control| Energy Efficiency Class
---|---|---|---|---|---|---|---
DN390B LED6| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN391B LED11| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN391B LED13| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN392B LED17| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN392B LED20| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN393B LED22| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|
DN394B LED36| 220-240~| 50/60| 830/840/865/930/940| WH/AL| IP20/IP54(Optical area)| PSU/PSD/WIA/L1/1-10V|

Dimension

Cut off Type Cut Out A(mm) B(mm) Weight(Kg)
D100 DN390B LED6 D100 105-110mm 68 D120
D100 DN391B LED11 D100 105-110mm 68 D120
D100 DN391B LED13 D100 105-110mm 68 D120
D150 DN391B LED11 D150 150-155mm 80 D162
D150 DN392B LED17 D150 150-155mm 80 D162
D150 DN392B LED20 D150 150-155mm 80 D162
D200 DN392B LED17 D200 200-205mm 107 D216
D200 DN393B LED22 D200 200-205mm 107 D216
D200 DN394B LED36 D200 200-205mm 107 D216

PHILIPS-DN390B-Green-Space-G6-Downlight- \(2\)

Installation

PHILIPS-DN390B-Green-Space-G6-Downlight- \(3\)

PHILIPS-DN390B-Green-Space-G6-Downlight- \(4\)

Philips Lighting (China) Investment Co., Ltd. Building No. 9, Lane 888 Tianlin Road, Minhang District, Shanghai, China Postalcode: 200233

WARNING RISK OF OVERHEATING OR FIRE IF THE CLEARANCE DISTANCES ARE COMPROMISED.

RISK OF FIRE-REQUIRED CLEARANCE FROM STRUCTURAL MEMBERS AND BUILDING ELEMENTS HCB=20mm MIC=20mm SCB=50mm SCI=0mm

Cut off Type SCB(mm) SCI(mm) MIC(mm HCB(mm)
D100 DN390B LED6 D100 0 0 209 209
D100 DN391B LED11 D100 0 0 209 209
D100 DN391B LED13 D100 0 0 209 209
D150 DN391B LED11 D150 0 0 205.5 205.5
D150 DN392B LED17 D150 0 0 205.5 205.5
D150 DN392B LED20 D150 0 0 205.5 205.5
D200 DN392B LED17 D200 0 0 197.5 197.5
D200 DN393B LED22 D200 0 0 197.5 197.5
D200 DN394B LED36 D200 0 0 197.5 197.5
  1. HCB(Height clearance to building element)
  2. MIC (Minimum insulation clearance)
  3. SCB(Side clearance to building element)
  4. SCI(Side clearance to insulation)

PHILIPS-DN390B-Green-Space-G6-Downlight- \(5\)

Building insulation abutting the luminaire must meet the following requirements:

  • Be of a type that can maintain its dimensions and structural integrity when exposed to the maximum surface temperatures of the class of luminaire,being 90°C
  • Be of a type able to withstand a 30 second needle flame test carried out in a accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the test sample.

Loose fill insulation as defined in NZS 4246 is not permitted to about or cover this luminaire or be used anywhere neat this downlight.

Switch OFF Before insert the socket

Product Type| Run Current| Start (Inrush)| Start Current| Touch current| MCB Type B 16A| MCB Type C 16A
---|---|---|---|---|---|---
(A)(@220V)| Current(A)| Duration (μs) /| or protective| Max no. fitting (pcs)| Max no. fitting (pcs)
 | / Ipeak (A)| T(@50% of Ipeak) (μs)| conductor current (mA)|  |
DN390B LED6 PSU| 0.029| 14| 10| 0.7| 120| 204
DN391B LED11 PSU| 0.049| 14| 10| 0.7| 120| 204
DN391B LED13 PSU| 0.058| 14| 10| 0.7| 120| 204
DN392B LED17 PSU| 0.073| 10| 20| 0.7| 100| 170
DN392B LED20 PSU| 0.08| 10| 20| 0.7| 100| 170
DN393B LED22 PSU| 0.097| 10| 20| 0.7| 100| 170
DN394B LED36 PSU| 0.148| 19.5| 258| 0.7| 40| 68
DN390B LED6 PSD| 0.039| 5.5| 55| 0.7| 32| 54
DN391B LED11 PSD| 0.052| 5.5| 55| 0.7| 32| 54
DN391B LED13 PSD| 0.061| 5.5| 55| 0.7| 32| 54
DN392B LED17 PSD| 0.076| 5.5| 55| 0.7| 32| 54
DN392B LED20 PSD| 0.084| 5.5| 55| 0.7| 32| 54
DN393B LED22 PSD| 0.101| 5.5| 55| 0.7| 32| 54
DN394B LED36 PSD| 0.148| 5.5| 55| 0.7| 32| 54

The leakage current * (touch current or protective conductor current)of electrical circuit may be greatly dependent upon electrical supply cables used as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions.

In some cases referred to as Earth Leakage Current

  1. The luminaire must be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  2. For indoor use only
  3. The luminaire is complied to IEC 60598-1 ed.8 or AS/NZ 60598.
  4. Do not switch on before complete installation.
  5. The light source of this luminaire is not replaceable; when the light source reaches its end of life the Whole luminaire shall be replaced
  6. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid hazard.