WORCESTER 12-18 Greenstar Danesmoor External Regular and External System Instruction Manual

June 1, 2024
WORCESTER

WORCESTER 12-18 Greenstar Danesmoor External Regular and External System

WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-
product

Specifications

  • Product: Greenstar Danesmoor External Regular 2022+ and External System 2022+
  • Boiler Types: 12/18, 18/25 & 25/32
  • Flue Type: Conventional and room sealed
  • Compatible with: Fully pumped open vent and sealed central heating systems, domestic hot water cylinders
  • Fuel Type: Kerosene (Class C2) only

Product Information

Energy Efficiency

The Greenstar oil-fired condensing boiler is designed for high energy efficiency, ensuring economical running costs and value for money.

Servicing

Regular servicing of the boiler is essential to maintain its performance and efficiency. Refer to the maintenance section for detailed instructions.

User Caution

Users should follow all safety instructions and guidelines provided in the user manual to ensure safe operation of the boiler.

Product Usage Instructions

Maintenance

Regular maintenance is crucial for the proper functioning of the boiler. Follow these steps:

  1. Ensure the boiler is turned off and cooled down before attempting any maintenance.
  2. Check and clean the boiler components as per the manufacturer’s instructions.
  3. Schedule professional servicing at regular intervals to keep the boiler in optimal condition.

Boiler Installation

Proper installation of the boiler is essential for its efficient operation. Follow these guidelines:

  1. Hire a qualified professional for the installation to ensure compliance with safety standards.
  2. Ensure proper ventilation and flue installation according to the manufacturer’s specifications.
  3. Connect the boiler to the central heating system and domestic hot water cylinders as required.

Fault Finding

If you encounter any issues with the boiler, follow these steps for fault finding:

  1. Refer to the user manual for common fault conditions and troubleshooting tips.
  2. If unable to resolve the issue, contact a qualified technician for assistance.

FAQ

Q: Can I use any fuel type with this boiler?

A: No, this boiler is designed to work with Kerosene (Class C2) fuel only. The use of other fuel types may damage the boiler.

Q: How often should I service the boiler?

A: It is recommended to service the boiler annually to ensure optimal performance and efficiency. Regular servicing also helps in identifying potential issues early.

Floor standing oil-fired condensing boiler using conventional flue and room sealed flue
Greenstar Danesmoor External Regular 2022+ and External System 2022+ 12/18, 18/25 & 25/32
For fully pumped open vent and sealed central heating systems and domestic hot water cylinders. For use with Kerosene (Class C2) only.

Preface

Please read these instructions carefully

  • These instructions are applicable to the Worcester, Bosch Group appliance model stated on the front cover only.
  • These instructions apply in the UK only and must be followed except for any statutory obligation.
  • After installation please leave this User instruction Manual, Installation, Commissioning and Servicing Instructions and completed Benchmark Checklist with the user.

Dedicated to heating comfort

  • Thank you for purchasing a Greenstar oil-fired condensing appliance manufactured by Worcester, Bosch Group. The company prides itself on manufacturing appliances to the strictest quality control standards throughout every stage of production.
  • Worcester, Bosch group has led the field in innovative appliance design and performance for over 50 years. This heritage means all our products are of exceptional quality and proven reliability.
  • The Greenstar range in particular is extremely energy efficient, offering you economical running costs and value for money. It is amongst the top energy rated appliances available.
  • There is also the reassurance of our parts and labour guarantee – backed up by Worcester Total Cover, an optional complete maintenance scheme to keep your appliance operating at peak condition and efficiency.

Key to symbols and safety instructions

Key to symbols

Warnings
Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background.

The following keywords are defined and can be used in this document:

  • NOTICE indicates a situation that could result in damage to property or equipment.
  • CAUTION indicates a situation that could result in minor to medium injury.
  • WARNING indicates a situation that could result in severe injury or death.
  • DANGER indicates a situation that will result in severe injury or death.

Important information

This symbol indicates important information where there is no risk to people or property.

Additional symbols

WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-
fig-1

Examples of additional symbols used

A numbered step in an action sequence
A sequence of numbered steps or actions carried out in a specific order to complete a task.

  1. First action
  2. Second action
  3. Third action etc.

A step in an action sequence
A sequence of defined actions or steps carried out in order to complete a task.

  • Action
  • Next action
  • etc.

A reference to a related part in the document or to other related documents.
To refer the reader to a specific figure/table/section within the manual.

e.g. figure 1.

A reference number to identify or refer to a part or item.
In a related figure, items or parts identified by a sequential number.

List entries, first and second levels

  • A single component/item
  • A component/list, made up of multiple parts/items.
    • Sub component or sub-list of main component/list.
    • etc.

Safety instructions
These operating instructions are intended for the user of the heating system.

  • Read any operating instructions (boiler, heating controls, etc.) carefully before operation and keep them.
  • Observe the safety instructions and warnings.

Oil fumes or leaks from the appliance
If you smell oil fumes, observe the following rules.

  • Extinguish any naked flames
  • Isolate the electrical supply
  • Isolate the fuel supply to the boiler
  • Contact an approved contractor and have the fault rectified

Health and safety
The appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations). Where applicable, the CE mark indicates compliance with relative EU Directives.

Combustion air/room air
The air in the installation room must be free of combustible or chemically aggressive substances.

Do not use or store combustible or explosive materials (paper, propellants, thinners, paints, etc.) within the vicinity of the appliance.

Safety of electrical devices for domestic use and similar purposes:
The following requirements apply in accordance with EN 60335-1 in order to prevent hazards from occurring when using electrical appliances:
“This appliance can be used by children of 8 years and older, as well as by people with reduced physical, sensory or mental capabilities or lacking in experience and knowledge, if they are supervised and have been given instruction in the safe use of the appliance and understand the resulting dangers. Children shall not play with the appliance. Cleaning and user maintenance must not be performed by children without supervision.”
“If the power cable is damaged, it must be replaced by the manufacturer, its customer service department or a similarly qualified person, so that risks are avoided.”

Intended use
This appliance must only be used as a heat appliance in an open vented or sealed hot water heating system for domestic purposes.
Any misuse or unauthorised modifications to the appliance, flue or associated accessories and heating system will invalidate the guarantee.

Do not modify the appliance or flue system in any way.

Worcester, Bosch Group accepts no liability arising from any such actions. This does not affect your statutory rights.

General Information

Energy efficiency
Energy efficiency information is given in the Installation, Commissioning and Servicing Instructions supplied with the appliance.

Servicing
The Service Checklist can be found at the rear of the boiler’s installation instructions. It will be required in the event of any guarantee work and may be required by the local Building Control Inspector.

  • Have the boiler serviced regularly by a competent, OFTEC registered engineer.
  • Ensure that the service engineer completes the Service Record, at the rear of the Installation, Commissioning and Servicing Instruction manual, after each service.
  • Have any work carried out only by a competent, OFTEC registered engineer.
  • Always use original spares, to help maintain the efficiency, safety and reliability of the appliance.

User caution
It is forbidden for any interference with the appliance other than those actions allowed in this document.

CAUTION: Incorrect use
Any incorrect use can result in danger to the householder.

Using your boiler

Remove the front panel to gain access to the boiler controls and reset buttons.
Release the latches at the base of the front panel, using the key provided, lower the panel and pull towards you to remove. Refer to the figure below.
Store the front panel safely away from the working area.

Controls

  1. Temperature control
  2. Pressure gauge (System boiler only)
  3. Boiler mode indicator
  4. Mode switch
  5. Reset button – Heating (behind the front panel)
  6. Reset button – Flue thermostat (behind the front panel)
  7. Lockout indicator / reset button (located behind the front panel on the burner control box see ‘reset button locations’ below).WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-2

Operating the boiler

Switching the boiler on/off

  • Remove the front panel to gain access to the controls.
  • To switch on the boiler; turn on the water, oil and electricity supply to the boiler.
  • Check the programmer/timer is correctly configured and is set to ON.
  • Set the room thermostat to the desired setting.
  • Open and set thermostatic radiator valves as required.
  • Turn the boiler water temperature control to the required setting.
  • To switch off the boiler; turn the programmer/timer to OFF for heating and hot water.
  • If the boiler is left unused and exposed to freezing conditions; shut off all the mains supplies, isolate the boiler and drain the system and boiler.

Setting the heating temperature

  • Turn the control clockwise to increase the water temperature. The demand light will illuminate until the water reaches the set temperature. Once the set temperature is reached the demand light extinguishes
  • Turn the control anti-clockwise to reduce the water temperature.WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-3

The minimum and maximum ranges of the temperature control positions are approximately 55°C to 81°C.

Controlling the central heating

  • Set the programmer/timer to the correct time with the required ON/OFF periods.
  • Turn the room thermostat to the temperature required.
  • Set the thermostatic radiator valves to achieve the required temperature for each room.

Frost protection

  • The appliance has a built-in frost thermostat to protect the internal components.
  • Frost thermostats can be wired into the boiler.
  • Frost protection should be fitted to the system where the system is most exposed and at risk of freezing.

If there is no hot water or heating, check page 11 and 12 for fault condition guidance.

Maintenance

Maintaining your boiler

  • Your new boiler represents a long term investment in a reliable, high quality product.
  • In order to realise its maximum working life and to ensure it continues to operate at peak efficiency and performance, it is essential that servicing and maintenance checks are performed at least once a year by an OFTEC engineer or other suitably qualified person.
  • If you would like to know more about servicing options from Worcester, Bosch Group, please visit worcester-bosch.co.uk. Please tick the appropriate box on your warranty registration card for further details of the Worcester, Bosch Group Service Contract.
  • When your boiler requires servicing please contact a Worcester, Bosch Group contact centre (see the back cover for details).
  • In addition to the service contract we are pleased to offer a one -off annual service or breakdown call out for your boiler.

Maintenance tips:

  • Regularly check the oil level in the tank
  • Do not obstruct the flue outlet or the air inlet
  • Regularly check the system pressure gauge, see chapter 5

Use in hard water areas
In exceptionally hard water areas a device to prevent scale formation may be fitted. Installation of a scale inhibitor assembly should be in accordance with the requirements of the local water company.
An isolating valve should be fitted to allow for servicing.

Servicing
You must have the boiler regularly serviced by a competent, qualified OFTEC registered engineer using approved spares, to help maintain the economy, safety and reliability of the boiler. The boiler should be serviced once each year after installation unless the installation conditions and usage demand more frequent services.

  • Ensure that the service engineer completes the Service Record in the checklist after each service.
  • The completed checklist will be required in the event of any warranty work and may be required by the local Building Control Inspector.
  • The checklist and service interval record can be found at the rear of the Installation, Commissioning and Servicing Instructions.

External filling loop (sealed system only)

This appliance is fitted to a sealed heating system which is pressurised. Your installer will advise you of the minimum and maximum pressure indicated on the pressure gauge.

  • Check regularly that the pressure is maintained.

  • If the pressure gauge reads less than 1 bar then the system requires re-charging.
    Check for leaks on heating system (pipe work and radiator valves).

  • Contact your installer or maintenance engineer if a permanent significant decrease or increase in pressure is indicated on the pressure gauge.
    Constantly having to re-pressurising the heating system should be investigated as the concentration of inhibitor in the system will be reduced; this can result in corrosion within the heating system.

Once the external filling loop has been located, follow the instructions for re-pressurising the system.

  1. Unscrew blanking cap.
  2. Attach the hose to the valves, screw on hand-tight.
  3. Turn the handle/screwdriver slot through 90° to open the valves.
  4. The handle/screwdriver slot will be in-line with the valvesWORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-4
  5. When the pressure reaches between the 1 and 1.5 bar marks (zone A), turn the handle/screwdriver slot back, through 90°, to close the valve.
  6. The handle/screwdriver slot will be at 90° to the valves
  7. Remove the hose and replace the blanking caps.
    If the pressure gauge reads more than 1.5 bar as a result of over filling, bleed one radiator until the pressure gauge returns to between 1 and 1.5 bar.

General information

WARNING:

  • External equipment operating at 230 Volts must not be serviced or repaired during adverse weather conditions.
  • Do not use pressure washers or steam cleaners on this appliance or cabinet.

Fuel
This appliance is designed to use (Class C2) Kerosene, no other fuel must be used.

Boiler installation

Boiler location

WARNING: Boiler installation:

  • This boiler must not be installed where here is a potential for excessive ground water coverage.
  • Never allow the flue terminal or air inlet to become obstructed by plants or any other objects.
  • To prevent “wetting” it is recommended that the flue terminal faces away from walls.
  • This boiler is only suitable for installing externally at a suitable location onto a fixed, permanent, rigid surface capable of supporting the boiler weight. Wood and tarmac hard-standings are not recommended.
  • The boiler must be installed on a flat level surface to ensure that condensate does not enter the primary heat exchanger.
  • The cabinet is not load bearing, and only provides weather protection for the boiler inside.
  • There must be sufficient hard standing and access around the boiler for servicing.WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-5

General notes
To get the best from your boiler, read these instructions carefully.

Central heating system
During the first few hours of operation of the central heating system, check that all radiators are being heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator. Ask your installer to show you how this is done. Repeated venting will reduce the quantity of water in the system and this must be replenished for safe and satisfactory operation of the boiler.
When excessive venting or water leaks are found in the system you must contact a service engineer to inspect the installation and rectify any fault.
Only use additives compatible with the boiler and system. Use of incompatible additives can cause damage and will invalidate the boiler guarantee.

Condensate drain
This is a condensing boiler and the terminal will, at times give out a plume of water vapour. This is quite normal.
The boiler also produces quantities of condensate which is discharged regularly via a pipe to drain.
This pipe must not be blocked or altered in any way.

Clearances, see section 6.2
Your installer will have provided adequate space around the boiler for safety and servicing access.
Do not restrict this space with the addition of trellises, fences etc. next to the boiler.

Room thermostat
A room temperature controller must be fitted to control the central heating. Refer to instructions supplied with the thermostat for information on siting and setting.

Thermostatic radiator valves
It is recommended that this type of valve is fitted to all but one of the radiators (or at least those in the sleeping accommodation). The remaining radiator, which must be where the room thermostat is located, should be un- controlled and must be left open.

Fault finding

In the event that the appliance stops functioning or does not perform as expected, you can carry out a few simple checks. These checks are some of the most common causes and are listed in the table below. Should the problem persist, then it will be necessary to contact Worcester, Bosch Group.

Problem Cause Remedy
Desired room temperature is not reached Thermostatic radiator valve(s) set
too low Increase thermostatic radiator valve setting(s).
Temperature control for central heating flow on boiler set too low

Increase central heating flow temperature control setting
Low temperature setting on the room thermostat| ▶| Increase settings on room thermostat
Air trapped in heating system (System model)| ▶| Bleed radiators and re- pressurise the heating system
Low system water pressure (System model)| ▶| Re-pressurise the system, refer to page 8
Desired room temperature is too high| Thermostatic radiator valve(s) are set too high| ▶| Turn down thermostatic radiator valves/room thermostat
Room thermostat is set too high| ▶| Reduce the thermostat setting
▶| Reduce central heating temperature by turning down the Central Heating control on boiler
Heating stays on for too long| Clock is incorrectly set| ▶| Check setting and adjust
Hot water temperature too low| Temperature set too low on cylinder thermostat control.| ▶| Check setting and adjust
Air trapped in heating system (System model)| ▶| Bleed radiators and re- pressurise the heating system
Low system water pressure (System model)| ▶| Re-pressurise the system, refer to page 8
Hot water temperature too high| Temperature set too high on cylinder thermostat control.| ▶| Check setting and adjust
System pressure low| Leak within the heating system| ▶| Check system for obvious leaks.

Table 2 Fault finding

Fault conditions
The ‘Boiler mode’ and ‘Lockout’ lights can indicate some basic fault conditions:

  1. Accessing controls:
    Undo the screws on the bottom of the front panel using the tool provided. The panel can be removed by pulling out at the base and then sliding down to disengage from the lid.

  2. Normal operation:
    Boiler mode light ON
    The appliance is in boiler mode, with a demand for heat from the controls.

  3. Both lights ON:
    Boiler not firing

    • Check the level in the oil tank.
    • Press the Reset button (A). The boiler should fire.
    • If there is no response, wait 2 minutes and press the Reset Button (A) again.
    • If Lockout light stays on, do not attempt further resets.
    • Contact your Service Engineer for advice.
  4. Boiler mode light ON, lockout light OFF:

    • Boiler not on – No heating/hot water
    • Press Reset Button (B), press Reset Button (C) both are below the fascia.
    • If the boiler remains off, contact your Service Engineer for advice.
    • If this fault re-occurs contact your Installer or Service Engineer.
  5. Both lights OFF:
    Boiler not on – No heating / hot water

    • Ensure there is power supply to the boiler.
    • Check the programmer is set to ON and thermostat is calling for heat.
    • Ensure that the Service switch is in Boiler mode.
    • If there is power supply to the boiler contact your service engineer for advice.WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-6

Fault or breakdown

This boiler is supported in mainland UK by Worcester, Bosch Group, part of Bosch Thermotechnology Ltd.
Specialist service engineers are available to attend a breakdown occurring on this appliance.

Invoices for attendance and repair work carried out on this appliance by any third party will not be accepted.

  • No charge will be made for parts and/or labour providing: An appliance fault is found and the appliance is within the guarantee period. Reasonable evidence of this must be supplied on request. i.e. the Benchmark Checklist.
    A call-out charge will be made where:

    • The appliance is outside the guarantee period.
    • Evidence cannot be provided that the first year service inspection has been carried out (i.e. an entry in the Benchmark Checklist).
    • Our Field Service Engineer finds no fault with the appliance.
    • The cause of breakdown is misuse or with other parts of your plumbing/heating system, or with equipment not supplied by Worcester, Bosch Group.
    • Before calling the help line check the central heating system pressure. If the pressure is low then check for obvious leaks around the heating system; repair before the system is re-pressurised.
    • For further support refer to the trouble shooting tool on the website.

If the boiler fails to give complete satisfaction, please check the following points before calling for a service engineer

  1. Oil level in the tank
  2. Power to the boiler
  3. All control settings

Technical support

No appliance fault is found on over 30% of all service calls.
In the case of a suspected fault, refer to the fault finding section of this guide.

In the event of a appliance fault or breakdown please contact Worcester, Bosch Group appointments team on 0330 123 9339.
Your advisor will arrange for an engineer to call with the minimum of delay; under normal circumstances this will be from 1 – 3 working days (excluding weekends and bank holidays) for priority breakdown situations (no hot water and/ or heating).

Boiler data label
The data label [1] can be found on the inside of the left hand side panel.
To access, remove the front panel:

  • Release the two latches at the bottom of the front panel using the key provided. The panel will drop down and can be carefully removed.
    To replace front panel:

  • Push the front panel up behind the top panel, push in and secure the latches in place with the key. (You can record this information on the inside back cover of this manual.)WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-fig-7

Energy saving

Tips on energy saving

Room thermostats
Reducing the setting of the room thermostat by 1°C can reduce fuel consumption by up to 10%.

New control systems
Upgrade your heating control system with the latest equipment available. The minimum level of control for a heating system is a programmer, interlocking room thermostat and thermostatic radiator valves.

Radiators

  • More often than not radiators will be sited underneath a window, so the warm air from the radiator heats the colder incoming air from the window.
  • The performance of the radiator will be affected if the curtains are allowed to drape over the radiator or shelves are fitted above it.
  • The positioning of furniture and tables in front of the radiator should also be avoided.
  • It is advisable to manually adjust all radiator valves every 2-3 months to prevent them from sticking. It is also important that the plastic tops of all valves are always in position and not cracked or damaged to help prevent accidents. Care should be taken when vacuum cleaning carpets to avoid damage to valves and pipework.
  • The heating system and the outputs of the radiators have been carefully selected by your installer. The temperature obtainable in any given room is dependent on all radiators being operated at the same time. If you decide to turn off radiators in unused rooms, spare bedrooms etc., you may experience slightly lower room temperatures in rooms adjacent to unheated rooms.

Heating economically

  • The boiler is designed to provide a high level of comfort while keeping oil consumption and the resulting environmental effect as low as possible.
  • The central heating control on the boiler should be set as low as possible while still maintaining a comfortable room temperature.
  • The temperature of each room can be set individually using the thermostatic radiator valves (except the primary room with the room thermostat).

Roof insulation
Around 30% of the heat loss from a property is through the roof. Replace any old insulation with new insulation, preferably to a minimum thickness of 200mm.

Window frames
Single glazed windows, particularly those with steel frames, can lose a great deal of heat.
Consideration should be given to replacement with uPVC or wooden framed double glazed units.

Curtains
Lined curtains, or heavier full length curtains can provide excellent insulation. However, always ensure that the curtains do not drape over radiators.

Draughts
Try to ensure that draughts around doors, windows, letterboxes and keyholes etc., are reduced by using a suitable draught excluder.

Your guarantee

This appliance has a guarantee against faulty materials or workmanship from the date of installation subject to the following terms and conditions:

  • During the period of this guarantee any components of the appliance which are proven to be faulty or defective in manufacture will be exchanged or repaired free of charge by Bosch Thermotechnology Ltd.
  • The householder may be asked to prove the date of installation, that the appliance was correctly commissioned and, where appropriate, the first year’s service has been carried out to the satisfaction of Bosch Thermotechnology Ltd., when requested. These should be documented as a part of the Benchmark Checklist.
  • The appliance has been used only for the normal domestic purposes for which it was designed.

This guarantee does not affect your statutory rights.

Guarantee registration
Your Greenstar appliance carries a guarantee against faulty material or manufacturer subject to Terms and Conditions. To read the full Terms & Conditions please visit us on-line at www.worcester-bosch.co.uk/guarantee. The Guarantee Registration form is available on this same page and can be completed and submitted electronically.
Alternatively, please telephone one of our Guarantee Registration advisors on 0330 123 2552.
Your statutory rights are not affected by the manufacturers guarantee.

For you records:

WORCESTER-12-18-Greenstar-Danesmoor-External-Regular-and-External-System-
fig-8

[*] Refer to the boiler data label inside the casing

Environment/disposal

Environmental protection is a fundamental corporate strategy of the Bosch Group.
The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed. We use the best possible technology and materials for protecting the environment taking account of economic considerations.

Packaging
We participate in the recycling programmes of the countries in which our products are sold to ensure optimum recycling. All of our packaging materials are environmentally compatible and can be recycled.

General checks before calling a Service engineer

Check the:

  1. Oil level in the tank?
  2. Power to the boiler?
  3. Control settings?

No boiler fault is found on over 30% of all service call outs.

Please read the fault section of the manual before contacting our service team.

Worcester, Bosch Group
Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0330 123 9559
Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd.
worcester-bosch.co.uk
6 721 844 015 (2022/01)

WORCESTER, BOSCH GROUP:

  • TECHNICAL SUPPORT: 0330 123 3366
  • APPOINTMENTS: 0330 123 9339
  • SPARES: 0330 123 9779
  • LITERATURE: 0330 123 9119
  • TRAINING: 0330 123 0166
  • SALES: 0330 123 9669

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WORCESTER User Manuals

Related Manuals