aldes INEA H D100 Permanent Air Extractor Installation Guide
- June 13, 2024
- aldes
Table of Contents
- INEA H D100 Permanent Air Extractor
- INTRODUCTION
- DELIVERY SET
- BRIEF DESCRIPTION
- OPERATION GUIDELINES
- MOUNTING
- ELECTRONIC SYSTEM OPERATION ALGORITHM
- MAINTENANCE
- TROUBLESHOOTING
- STORAGE AND TRANSPORTATION REGULATIONS
- MANUFACTURER’S WARRANTY
- TECHNICAL CHARACTERISTICS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INEA H D100 Permanent Air Extractor
Installation Guide
INEA H D100 Permanent Air Extractor
This user’s manual is a main operating document intended for technical,
maintenance, and operating staff.
The manual contains information about purpose, technical details, operating
principle, design, and installation of the Inea unit and all its
modifications. Technical and maintenance staff must have theoretical and
practical training in the field of ventilation systems and should be able to
work in accordance with workplace safety rules as well as construction norms
and standards applicable in the territory of the country.
INTRODUCTION
Attention: read the user’s manual carefully before proceeding with
installation works. Compliance with the manual requirements ensures reliable
operation and long Service life of the unit. Keep the user’s manual available
as long as you use the unit. You may need to reread the information on the
product servicing.
This unit is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made by children without
supervision.
Children shall not play with the appliance.
Precautions must be taken to avoid the back-flow of gases into the room from
the open flue of gas or other fuel-burning appliances.
Connection to the mains must be made through a disconnecting device, which is
integrated into the fixed wiring system in accordance with the wiring rules
for design of electrical units, and has a contact separation in all poles that
allows for full disconnection under overvoltage category III conditions.
Ensure that the unit is switched off from the supply mains before removing the
guard.
All operations described in this manual must be performed by qualified
personnel only, properly trained and qualified to install, make electrical
connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or perform
maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All user’s manual requirements as well as the provisions of all the applicable
local and national construction, electrical, and technical norms and standards
must be observed when installing and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing,
maintenance, and repair operations.
Only qualified electricians with a work permit for electrical units up to 1000
V are allowed for installation. The present user’s manual should be carefully
read before beginning works.
Check the unit for any visible damage of the impeller, the casing, and the
grille before starting installation. The casing internals must be free of any
foreign objects that can damage the impeller blades.
While mounting the unit, avoid compression of the casing! Deformation of the
casing may result in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky
substances, or fibrous materials.
Do not use the unit in a hazardous or explosive environment containing
spirits, gasoline, insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the
efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the
document’s preparation.
The Company reserves the right to modify the technical characteristics,
design, or configuration of its products at any time in order to incorporate
the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE RELEVANT USER MANUALS.
**** THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
DELIVERY SET
Fan | – 1 pc. |
---|---|
Screws with dowels | – 4 pcs. |
Plastic screwdriver | – 1 pc. (only for the models with a timer) |
User’s manual | – 1 pc. |
Packing box | – 1 pc. |
BRIEF DESCRIPTION
The product is an axial fan for exhaust ventilation of small and medium-sized premises heated in winter. The design of the fan may include a back valve that prevents air from flowing into the room when the fan is off. The fan is designed for connection to Ø100 mm air ducts.
OPERATION GUIDELINES
The fan is rated for connection to 220-240 V/50 Hz single-phase AC power mains, depending on the model type. For more detailed information, see the casing sticker. Ingress protection rating against access to hazardous parts and water ingress is IP44. The manufacturer’s recommended operating temperature range is from +1 °C to + 40 °C.
MOUNTING
The fan can be mounted to the ceiling or onto a wall with air extraction into
a ventilation shaft or a matching diameter round air duct (Fig. 2).
The fan installation steps are given on Fig. 3-11. Electric connection
diagrams are given on Fig. 12-13. Connection diagram terminal key:
L — line
N — neutral
S — external switch
QF — automatic switch
ELECTRONIC SYSTEM OPERATION ALGORITHM
The H model fan with a timer
and humidity sensor is switched to the Speed 2 when the set humidity level
in the room (from 60 to 90 %) is exceeded. As the indoor humidity level drops
down to the set value, the fan continues to operate for 5 minutes and goes to
the Speed 1. The fan can be turned on in manual mode, for example, using a
light switch.After turning on the switch, the fan switches to Speed 2 with a
time delay of 45 s. After the switch is turned off, the fan will continue to
work at the Speed 2 for the time set by the turn-off delay timer, from 2 to 30
minutes, then it will switch to the Speed 1.To set the maximum level of
humidity, it is necessary to set the potentiometer regulator to the H max
position (90 %).
— To adjust the humidity sensor threshold value turn the H potentiometer knob
clockwise (+) or counter-clockwise (-) which sets the threshold value within
the range from 60 % to 90 %. The fan is supplied with a special plastic
screwdriver. Use the screwdriver to adjust the fan activation or deactivation
delay time or the humidity sensor threshold value.
Attention: The timer circuit is live.
Make sure the fan is disconnected from power supply.
Do not use a metal screwdriver, knife, etc.
For adjustment operations not to damage the circuit board.
MAINTENANCE
To clean the unit from any dust and dirt which may accumulate on the surfaces (Fig. 14-17), use a soft cloth and a brush soaked in a mild detergent solution. Avoid spilling liquid on the electrical components. Wipe the cleaned surfaces dry.
TROUBLESHOOTING
Problem | Possible reasons | Troubleshooting. |
---|
When the unit is connected to power mains, the fan does not rotate and does
not respond to any controls.| No power supply.| Make sure the power supply
line is connected correctly, otherwise troubleshoot the connection error.
Internal connection fault.| Contact the Seller.
Low air flow.| The ventilation system is clogged.| Clean the ventilation
system.
Increased noise, vibration.| The impeller is clogged.| Clean the impeller.
The fan is not secured well or is not mounted properly.| Troubleshoot the
installation error.
The ventilation system is clogged.| Clean the ventilation system.
STORAGE AND TRANSPORTATION REGULATIONS
Store the unit in the manufacturer’s original packaging box in a dry closed
ventilated premise with temperature range +5 °C up to + 40 °C and relative
humidity up to 70 %.
Storage environment must not contain aggressive vapors and chemical mixtures
provoking corrosion, insulation, and sealing deformation.
Use suitable hoist machinery for handling and storage operations to prevent
possible damage to the unit.
Follow the handling requirements applicable for the particular type of cargo.
The unit can be carried in the original packaging by any mode of transport
provided proper protection against precipitation and mechanical damage. The
unit must be transported only in the working position.
Avoid sharp blows, scratches, or rough handling during loading and unloading.
Prior to the initial power-up after transportation at low temperatures, allow
the unit to warm up at operating temperature for at least 3-4 hours.
MANUFACTURER’S WARRANTY
The product is in compliance with EU norms and standards on low voltage
guidelines and electromagnetic compatibility. We hereby declare that the
product complies with the provisions of Electromagnetic Compatibility (EMC)
Directive 2014/30/EU of the European Parliament and of the Council, Low
Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the
Council and CE-marking Council Directive 93/68/EEC. This certificate is issued
following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 60 months
after the retail sale date provided the user’s observance of the
transportation, storage, installation, and operation regulations. Should any
malfunctions occur in the course of the unit operation through the
Manufacturer’s fault during the guaranteed period of operation, the user is
entitled to get all the faults eliminated by the manufacturer by means of
warranty repair at the factory free of charge. The warranty repair includes
work specific to elimination of faults in the unit operation to ensure its
intended use by the user within the guaranteed period of operation. The faults
are eliminated by means of replacement or repair of the unit components or a
specific part of such unit component.
The warranty repair does not include:
- routine technical maintenance
- unit installation/dismantling
- unit setup
To benefit from warranty repair, the user must provide the unit, the user’s manual with the purchase date stamp, and the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty service.
The manufacturer’s warranty does not apply to the following cases:
- User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts previously dismounted by the user.
- Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user’s manual.
- User’s failure to ensure timely technical maintenance of the unit.
- External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.
- Redesign or engineering changes to the unit.
- Replacement and use of any assemblies, parts and components not approved by the manufacturer.
- Unit misuse.
- Violation of the unit installation regulations by the user.
- Violation of the unit control regulations by the user.
- Unit connection to power mains with a voltage different from the one stated in the user’s manual.
- Unit breakdown due to voltage surges in power mains.
- Discretionary repair of the unit by the user.
- Unit repair by any persons without the manufacturer’s authorization.
- Expiration of the unit warranty period.
- Violation of the unit transportation regulations by the user.
- Violation of the unit storage regulations by the user.
- Wrongful actions against the unit committed by third parties.
- Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
- Missing seals if provided by the user’s manual.
- Failure to submit the user’s manual with the unit purchase date stamp.
- Missing payment paperwork certifying the unit purchase.
Attention: Following the regulations stipulated herein will ensure a long
and trouble-free operation of the unit.
User’s warranty claims shall be subject to review only upon presentation of
the unit, the payment document and the user’s manual with the purchase date
stamp.
TECHNICAL CHARACTERISTICS
Need after sales technical support?
Visit our website for more information: https://www.aldes-
international.com/fr/contact/
www.aldes.com
20, boulevard Irène Joliot-Curie 69694 Vénissieux Cedex – France Aldes-Inea100
-Inst-Corp-11022968
A
– 122022 – RCS 956 506 828 – Aldes
References