Specifications:

  • Model Variants: TA36QQCT-1232IAWT, TA36QQDT-1232IAWT, TA36QQAT-1232IAT, TA36QAAT-1232IAW, TA37QABT-1232IAWUV, TA35QQET-1232IHWT, TA35QQFT-1232IHWT, TA35QQFT-1232IHWTUV, TA53QQCT-1832IAWT, TA53QQET-1832IHWT, TA53QQFT-1832IHWT, TA73QQCT-2432IAWT, TA72QQET-2432IHWT, TA72QQFT-2432IHWT
  • Refrigerant: R32
  • Inverter: DC Inverter

Product Usage Instructions

Safety Precautions:

Incorrect installation or operation may cause harm or damage. Follow these safety precautions:

  • WARNING! – Possibility of death or serious injury.
  • CAUTION! – Possibility of injury or damage to properties.

Grounding:

The air conditioner must be properly grounded. Incomplete grounding may result in electric shocks. Do not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire. Seek assistance from a qualified person.

R32 Flammable Refrigerant:

Warning: This air conditioner uses R32 flammable refrigerant. Handle with care as it may cause harm if roughly treated.

Symbols:

  • Note WARNING: – This symbol indicates the appliance uses a flammable refrigerant.
  • CAUTION CAUTION: – Service personnel should handle the equipment with reference to the installation manual.
  • Symbol: – Information available in operating or installation manual.

Frequently Asked Questions

  • Q: Is it mandatory to ground the air conditioner?
    • A: Yes, the air conditioner must be properly grounded to avoid electric shocks and ensure safety.
  • Q: Can I use the air conditioner without reading the manual?
    • A: It is highly recommended to read the manual thoroughly before operating the unit to prevent any potential harm or damage.

SPLIT-TYPE AIR CONDITIONER

USER MANUAL

For R32 DC Inverter models:

TA36QQCT-1232IAWT TA36QQDT-1232IAWT TA36QQAT-1232IAT TA36QAAT-1232IAW TA37QABT-1232IAWUV TA35QQET-1232IHWT TA35QQFT-1232IHWT TA35QQFT-1232IHWTUV

TA53QQCT-1832IAWT TA53QQET-1832IHWT TA53QQFT-1832IHWT TA73QQCT-2432IAWT TA72QQET-2432IHWT TA72QQFT-2432IHWT

ENG

BIH/ MNE

BG

GR

HR

HU MKD RO SLO SRB

Ver. 2024

ENG

OPERATING INSTRUCTION

Note: All the pictures in this manual are just schematic diagrams, the actual is the standard. Please read this owner’s manual carefully and thoroughly before operating the unit! Take care of this manual for future reference.

BIH/ MNE

UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo za upotrebu prije koriscenja ureaja! Sacuvajte ovo uputstvo za buducu upotrebu.

BG

: , . , !

GR

: , . ! .

HR

UPUTE ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo shematski dijagrami, fizicki proizvod je standard. Molimo Vas da pazljivo i temeljito procitate ovo uputstvo za upotrebu prije koristenja ureaja! Cuvajte ovaj prirucnik za buduce koristenje.

HU

FELHASZNÁLÓI KÉZIKÖNYV
Megjegyzés: A kézikönyvben található képek csak sematikus ábrák, az aktuális a szabvány. Kérjük, figyelmesen olvassa el ezt a kézikönyvet mieltt mködtetné az eszközt! rizze meg ezt a kézikönyvet a késbbiekre is.

MKD

: , . ! .

RO

MANUAL DE UTILIZARE
Nota: Fotografiile din acest manual sunt doar diagrame schematice. V rugm s citii “Manualul de Utilizare” cu atenie, înainte de a utiliza aerul condiionat, pentru a asigura funcionarea corespunztoare. Pstrai manualul pentru referine ulterioare.

SLO

PRIROCNIK ZA UPORABO
Opomba: Vse slike v tem prirocniku so le shematske risbe, dejansko stanje je standard. Prosimo, da pred uporabo skrbno in temeljito preberete ta prirocnik za uporabo! Prirocnik shranite za kasnejso uporabo.

SRB

UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo za upotrebu pre koriscenja ureaja! Sacuvajte ovo uputstvo za buducu upotrebu.

ENG
WARNING
Warning: This air conditioner uses R32 flammable refrigerant.
Notes: Air conditioner with R32 refrigerant, if roughly treated, may cause serious harm to the human body or surrounding things.
· The room space for the installation, use, repair, and storage of this air conditioner should be greater than 5 m’. · Air conditioner refrigerant can not charge more than 1. 7kg. · Do not use any methods to speed up defrost or to clean frosty parts except for particular recommended by
manufacturer. · Not pierce or burn air conditioner, and check the refrigerant pipeline wether be damaged. · The air conditioner should be stored in a room without lasting fire source, for example, open flame, burning gas
appliance, working electric heater and so on. · Notice that the refrigerant may be tasteless. · The storage of air conditioner should be able to prevent mechanical damage caused by accident. · Maintenance or repair of air conditioners using R32 refrigerant must be carried out after security check to
minimize risk of incidents. · Air conditioner must be installed with stop valve cover. · Please read the instruction carefully before installing, using and maintaining.

Symbol

Note WARNING

Explanation
This symbol shows that this appliance uses a flammable refrigerant.If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.

CAUTION

This symbol shows that the operation manual should be read carefully.

CAUTION CAUTION

This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
This symbol shows that information is available such as the operating manual or installation manual.

SAFETY PRECAUTIONS

Incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc. The seriousness is classified by the following indications:

WARNING!

This symbol indicates the possibility of death or serious injury.

CAUTION!

This symbol indicates the possibility of injury or damage to properties.

3

ENG

WARNING!

· This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (Only for the AC with CE-MARKING)

· This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (Except for the AC with CE-MARKING)

·

The air conditioner must be grounded. Incomplete grounding may result in electric shocks. Do

not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire.

· Always switch off the device and cut the power supply when the unit is not in use for long time so as to ensure safety.

· Take care not let the remote control and the indoor unit watered or being too wet. Otherwise, it may cause short circuit.

· If the power supply cable is damaged, it must be replaced by manufacture or its service agent or a similar

qualified person.

· Don’t cut off main power switch during operating or with wet hands. It may cause electric shock.

· Don’t share the socket with other electric appliance. Otherwise, it may cause electric shock even fire and explosion.

· Always switch off the device and cut the power supply before performing any maintenance or cleaning.

Otherwise, it may cause electric shock or damage.

· Don’t pull the power cord when pull out the power plug. The damage of pulling power cord will cause serious

electric shock.

· A warning that ducts connected to an appliance shall not contain an ignition source.

· Don’t install air conditioner in a place where there is flammable gas or liquid. The distance between them should above 1m. It may cause fire even explosion.

· Don’t use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either.

Doing this may cause electric shock or damage to the unit.

· Don’t attempt to repair the air conditioner by yourself. Incorrect repairs may cause fire or explosion. Contact a

qualified service technician for all service requirement.

· Don’t use air conditioner in lightning strom weather. Power supply should be cut in time to prevent the occurrence of danger.

· Don’t put hands or any objects into the air inlets or outlets. This may cause personal injury or damage to the unit.

· Please note whether the installed stand is firm enough or not. If it is damaged, it may lead to the fall of the unit and cause the injury.

· Don’t block air inlet or air outlet. Otherwise, the cooling or heating capacity will be weakened, even cause system stop operating.

· Don’t let the air conditioner blow against the heater appliance. Otherwise it will lead to incomplete combustion, thus causing poisoning.

· The appliance shall be installed in accordance with national wiring regulations.

· An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks.

· This product contains fluorinated greenhouse gases.

· Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

· Ensure no following objects under the indoor unit: 1. microwaves, ovens and other hot objects. 2. computers and other high electrostatic appliances. 3. sockets that plug frequently.

· The joints between indoor and outdoor unit shall not be reused, unless after re-flaring the pipe.

· The specification of the fuse are printed on the circuit bord, such as: 3.15A/250V AC, etc.

4

ENG
WEEE Warning
Meaning of crossed out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging yourhealth and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.

CAUTION!

· Don’t open the windows and doors for long time when the air conditioner is running. Otherwise, the cooling or heating capacity will be weakened.
· Don’t stand on the top of the outdoor unit or place heavy things on it. This cloud cause personal injuries or damage the unit.
· Don’t use the air conditioner for other purposes, such as drying clothes, preserving foods,etc.
· Don’t apply the cold air to the body for a long time. It will deteriorate your physical conditions and cause health problems.
· Set the suitable temperature. It is recommended that the temperature difference between indoor and outdoor temperature should not be too large. Appropriate adjustments of the setting temperature can prevent the waste of electricity.
· If your air conditioner is not fitted with a supply cord and a plug, an anti-explosion all-pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3.0 mm.
· If your air conditioner is permanently connected to the fixed wiring, a anti-explosion residual current device (RCD) having rated residual operating current not exceeding 30 mA should be installed in the fixed wiring.
· The power supply circuit should have leakage protector and air switch of which the capacity should be more than1 .5 times of the maximum current.
· Regarding the installation of the air conditioners, please refer to the below paragraphs in this manual.

NOTICES FOR USE

The conditions of unit can’t normally run
· Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may arise.

Cooling

Outdoor Indoor

43°C (Apply to T1) >52°C (Apply to T3)
<18°C

Heating

Outdoor Indoor

24°C <-7°C
27°C

· When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air conditioner could be shut down.
· When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water dripping or other malfunction.
· In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows are open), there may be water condenses or dripping near the air outlet.
· T1 and T3 refer to ISO 5151.

5

ENG
Notes for heating
· The fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air.
· When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will increased the heating capacity. Then the air conditioner will start defrost function.
· During defrost, the air conditioner will stop heating for about 5-12 minutes. · Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost. · Heating will resume after defrost is complete.

Notes for turning off

· When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.

Emergency operation

· If the remote controller is lost or broken, use force switch button to operate the air conditioner.
· If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode.
· If this button is pushed with the unit ON, the air conditioner will stop running.

Force switch

Airflow direction adjustment
1. Use up-down swing and left-right swing buttons on the remote controller to adjust the airflow direction. Refer to the operation manual of the remote controller for detail.
2. For models without left-right swing function, the fins has to be moved manually.
Note: Move the fins before the unit is in operation, or your finger might be injured. Never place your hand into the air inlet or outlet when the air conditioner is in operation.
Specific caution
1.Open front panel of the indoor. 2. The connector (as Fig) can not touch the terminal
board, and is positioned as shown in Fig.

Connector
Cable 1 Cable 2 Terminal board

6

NAMES OF EACH PART

Air inlet grille Panel

Indoor unit
Air inlet

Air filter

Air louver Air vent

Air outlet

ENG Force switch
Pipe protection ring

Remote controller

Outdoor unit
Power cable

Air outlet grille

Connecting pipe Drain hose

Air outlet Note: All the pictures in this manual are just schematic diagrams, the actual is the standard. Plug, WiFi function, Negative-ion function, and vertical and horizontal; swing function both are optional.
7

CLEAN AND CARE

WARNING! · Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than
5 minutes, otherwise there might be the risk of electric shocks. · Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with
water under any circumstances. · Volatile liquids such as thinner or gasoline will damage the air conditioner housing, therefore please clean the
housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent. · In the course of the using, pay attention to cleaning the filter regularly, to prevent the covering of dust which
may affect the effect. If the service environment of the air conditioner is dusty, correspondingly increase the number of times of cleaning. After removing the filter, do not touch the fin part of the indoor unit with the finger, and no force to damage the refrigerant pipeline.
Clean the panel
When the panel of the indoor unit is contaminated, clean it gently with a wrung towel using tepid water below 40°C, and do not remove the panel while cleaning.
Clean the air filter
Remove the air filter
1. Use both hands to open the panel for an angle from both ends of the panel in accordance with the direction of the arrow.
2. Release the air filter from the slot and remove it.
Clean the Air Filter Use a vacuum cleaner or water to rinse filter, and if the filter is very dirty (for example, with greasy dirt), clean it with warm water (below 45 °C) with mild detergent dissolved in, and then put the filter in the shade to dry in the air.
Mount the Filter 1. Reinstall the dried filter in reverse order of removal, then cover and lock the panel.
Check before use
1. Check whether all the air inlets and outlets of the units are unblocked. 2. Ceck whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any. 3. Check the ground wire is reliably grounded. 4. Check whether the remote control batteries are installed, and whether the power is sufficient. 5. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local
service center.
8

ENG
Maintain after use
1. Cut off the power source of the air conditioner, turn off the main power switch and remove the batteries from the remote controller.
2. Clean the filter and the unit body. 3. Remove the dust and debris from the outdoor unit. 4. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local
service center.

CAUTION!
Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or fire or explode, please contact the authorized service center and let the professionals conduct the maintenance, and checking the following items prior to contacting for maintenance can save your time and money.

TROUBLESHOOTING

Phenomenon
The air conditioner does not work.
The air conditioner can’t run after the immediate start-up after it is shut down. The air conditioner stops running after it starts up for a while.
The wind blows out, but the cooling/ heating effect is not good.
The indoor unit blows out odor. There is sound of running water during the running of air conditioner.

Troubleshooting
· There might be power outages. Wait until power is restored. · Power plug may be loose out from the socket. The plug in the plug tightly. · Power switch fuse may blow. Replace the fuse. · The time for timing boot is yet to come. Wait or cancel the timer settings.
· If the air conditioner is turned on immediately after it is turned off, the protective delay switch will delay the operation for 3 to 5 minutes.
· May reach the setting temperature. It is a normal function phenomenon. · May be at a defrosting state. It will automatically restore and run again after
defrosting. · Shutdown Timer may be set. If you continue to use, please turn it on again.
· Excessive accumulation of dust on filter, blocking at air inlet and outlet, and the excessively small angle of the louver blades all will affect the cooling and heating effect. Please clean the filter, remove the obstacles at the air inlet and outlet and regulate the angle of the louver blades.
· Poor cooling and heating effect caused by doors and windows opening, and unclosed exhaust fan. Please close the doors, windows, the exhaust fan, etc.
· Auxiliary heating function is not turned on while heating, which may lead to poor heating effect. Turn on the auxiliary heating function. (only for models with auxiliary heating function)
· Mode setting is incorrect, and the temperature and wind speed settings are not appropriate. Please re-select the mode, and set the appropriate temperature and wind speed.
· The air conditioner itself does not have undesirable odor. If there is odor, it may be due to accumulation of the odor in the environment. Clean the air filter or activate the cleaning function.
· When the air conditioner is started up or stopped, or the compressor is started up or stopped during the running, sometimes the “hissing” sound of running water can be heard. This is the sound of the flow of the refrigerant, not a malfunction.

9

ENG

Phenomenon A slight “click” sound is heard at the of start-up or shut-down.
The indoor unit makes abnormal sound.
There are water drops over the surface of the indoor unit.
During the cooling operation, the indoor unit outlet sometimes will blow out mist.

Troubleshooting
· Due to temperature changes, panel and other parts will swell, causing the sound of friction. This is normal, not a fault.
· The sound of fan or compressor relay switched on or off. · When the defrosting is started or stop running, it will sound. That is due to the
refrigerant flowed to reverse direction. They are not malfunctions. · Too much dust accumulation in the air filter of the indoor unit may result in
fluctuation of the sound. Clean the air filters in time. · Too much air noise when “Strong wind” is turned on. This is normal, if feeling
uncomfortable, please deactivate the “Strong wind” function.
· When ambient humidity is high, water drops will be accumulated around the air outlet or the panel, etc. This is a normal physics phenomenon.
· Prolonged cooling run in open space produces water drops. Close the doors and windows.
· Too small opening angle of the louver blades may also result in water drops at the air inlet. Increase the angle of the louver blades.
· When the indoor temperature and humidity are high, it happens sometimes. This is because the indoor air is cooled rapidly. After it runs for some time, the indoor temperature and humidity will be reduced and the mist will disappear.

Immediately stop all operations and cut off the power supply, contact our Service center locally in following situations.
· Hear any harsh sound or smell any awful odor during running. · Abnormal heating of power cord and plug occurs. · The unit or remote controller has any impurity or water. · Air switch or leakage protection switch is often disconnected.

NOTICES FOR INSTALLATION

IMPORTANT NOTICES!
· Before installating, please contact with local authorized maintenance cenler, if unit is not installed by the authorized maintenance center, the malfunction may not solved,due to discommodious contact.
· The air conditioner must be installed by professionals according to the national wiring rules and this manual. · Refrigerant leak tesf must be made after installation. · To move and install air conditioner to another place, please contact our local special service center.
Unpacking Inspection
· Open the box and check air conditioner in area with good ventilation (open the door and window) and without ignition source. Note: Operators are required to wear anti-static devices.
· It is necessary to check by professional whether there is refrigerant leakage before opening tlie box of outdoor machine; stop installing the air conditioner if leakage is found.
· The fire prevention equipment and anti-static precautions shall be prepared well before checking.Then check the refrigerant pipeline to see if there is any collision traces, and whether the outlook 1s good.

10

ENG
Safety Principles for Installing Air Conditioner
· Fire prevention device shall be prepared before installation. · Keep installing site ventilated.(open the door and window) · Ignition source,smoking and calling is not allowed to exist in area where R32 refrigerant rocated. · Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and gloves. · Keep leak detector in working state during the installation. · If R32 refrigerant leakage occurs during tfle installation, you shall immediately detect the concentration in indoor
environment until it reaches a safe level. If refrigerant leakage affects the performance of the air conditioner, please immediately stop the operation, and the air conditioner must be vacuumed firstly and be returned to the maintenance station for processing. · Keep electric appliance, power switch, plug, socket, high temperature heat source and high static away from the area underneath sidelines of the indoor unit. · The air conditioner shall be installed in an accessible location to installation and maintenance, without obstacles that may block air inlets or outlets of indoor/outdoor units, and shall keep away from heat source inflammable or explosive conditions. · When installing or repairing the air conditioner and the connecting line is not long enough, the entire connecting line shall be replaced with the connecting line of the original specification; extension is not allowed. · Use new connection pipe, unless re-flaring the pipe.
Requirements For Installation Position
· Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases. · Avoid places subject to strong artificial electric/magnetic fields. · Avoid places subject to noise and resonance. · Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine or h1gli temperature
heat sources). · Avoid places within the reach of cnildren. · Shorten the connection between the indoor and outdoor units. · Select where it is easy to perform service and repair and where the ventilation good. · The outdoor unit shalrnot be installed in any way that could occupy an aisle, stairway, exit, fire escape, catwalk or
any other public area. · The outdoor unit shall be installed as far as possible from the doors and windows of the neighbors as well as the
green plants.
Installation environment inspection
· Check nameRlate of outdoor unit to make sure whether the refrigerant is R32. · Check the floor space of the room. The space shall not be less than usable space(sm2 ) in the specification.The
outdoor unit shall be installed at a well-ventilated place. · Check the surrounding environment of installation site: R32 shall not be installed in the enclosed reserved space
of a building. · When using electric drill to make holes in the wall, check first whether there is pre-buried pipeline for water,
electricity and gas. · It is suggested to use the reserved hole in the roof of tfle walr
Requirements of the mounting structure
· The mounting rack must meet the relevant national or industrial standards in terms of strength with welding and connection areas rustproofed.
· The mounting rack and its load carry surface shall be able to withstand 4 times or above the weight of the unit, or 200kg, whichever is heavier.
· The mounting rack of the outdoor unit shall be fastened with expansion bolt. · Ensure the secure installation regardless of what type of wall on which it is installed, to prevent potential
dropping that could hurt people.
11

ENG
Electrical Safety Requirements
· Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cord diameter must meet the national requirements.
· When the maximum current of air conditioner is 16A, it must use the air switch or leakage protection switch equipped with protection devices.
· The operating range is 90%-110% of the local rated voltage. But insufficient power supply malfunction, electrical shock, or fire. If the voltage instability, proposed to increase the voltage regulator.
· The minimum clearance between the air conditioner and the combustibles is 1.5 m. · The interconnection cord connect the indoor and outdoor units. You must first choose the right cable size
before preparing it for connection. · Cable Types: Outdoor Power Cable: H07RN-F or H05RN-F;
Interconnection cord: H07RN-F or H05RN-F; · Minimum Cross-Sectional Area of Power cable and interconnection cord.

North America

Appliance Amps (A)
10 13 18 25 30 40

AWG
18 16 14 12 10 8

Other regions

Rated Current of Appliance (A) >3 and 6 >6 and 10 >10 and 16 >10 and 16 >10 and 16 >10 and 16

Nominal Cross-Sectional Area (mm2) 0.75 1 1.5 2.5 4 6

· The size of the interconnection cord, power cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.
· Note: Core number of cable refer to the detailed wiring diagram adhered on the unit which you purchased.
Requirements for operations at raised height
· When carrying out installation at 2m or higher above the base level, safety belts must be worn and ropes of sufficient strength be securely fasten to the outdoor unit, to prevent falling that could cause personal injury or death as well as property loss.
Grounding Requirements
· The air conditioner is the class I electrical appliance and must ensure a reliable grounding. · Do not connect the grounding wire to a gas pipe, water pipe, lightning rod, telephone line, or a circuit poorly
grounded to the earth. · The grounding wire is specially designed and shall not be used for other purpose, nor shall it be fastened with a
common tapping screw. · Interconnection cord diameter should be recommended as per instruction manual ,and with type O terminal
that meet local standards (internal diameter of type O terminal needs to match the screw size of the unit, no more than 4.2mm). After installation, check the screws whether have been fixed effectively, and there is no risk of loosening.

12

ENG
Others
· The connection method of the air conditioner and the power cord and the interconnection method of each independent element shall be subject to the wiring diagram affixed to the machine.
· The model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse sleeve.

Packing list

Packing list of the indoor unit

Name Indoor Unit Remote Controller Batteries (7#) Owner’s manual Drain pipe

Quantity Unit

1

Set

1

PC

2

PC

1

Set

1

PC

Packing list of the outdoor unit

Name
Outdoor Unit
Connecting pipe (optional)
Plastic Strap
Pipe Protection Ring
Luting (putty) (optional)

Quantity 1 2 1 1 1

Unit Set PC ROLL PC PACKET

Note: All accessories s hall be subject to actual packaging material, and if there is any difference, please understand.

INSTALL INDOOR UNIT
Dimension drawing of indoor unit installation

Space to the wall 20cm above

Space to the ceiling 15cm above

Space to the wall 20cm above

200-260cm Space to the floor

13

ENG
Mounting plate
1. The wall for installation of the indoor unit shall be hard and firm, so as to prevent vibration.
2. Use the “+” type screw to fasten the peg board, horizontally mount the peg board on the wall, and ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to confirm whether it is solid.
Wall-through Hole
1. Make a hole with an electric hammer or a water drill at the predetermined position on the wall for piping, which shall slant outwardly by 5° -10° .
2. To protect the piping and the cables from being damaged running through the wall, and from the rodents that may inhabit in the hollow wall, a pipe protecting ring shall be installed and sealed with putty.
Note: Usually, the wall hole is 60mm~80mm. Avoid preburied power wire and hard wall when making the hole.

Putty

Pipe protection ring

Route of Pipeline

1. Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In the case of sideway routing, cut off the outlet cutting stock of the opposite side.

Fig 1

Connecting Pipe Drain Hose and Cables

Fig 2 Connecting Pipe Drain Hose and Cables

Outlet material preparation

14

ENG
Drain pipe connection
1. Remove the fixed part to pull out pipe of indoor machine from the case. Screw the hexagon nut in the left of the joint to the end with your hand.
2. Connect the connecting pipe to the indoor unit: Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a torque wrench, and the direction is shown in diagram on the right. The torque used is shown in the following table.
Note: Carefully check if there is any damage of joints before installation. The joints shall not be reused, unless after re-flaring the pipe.

Tightening torque table
The size of pipe (mm) 6 / 6. 35 9 / 9. 52 12 / 12.7 15.88 19.05

Torque (Nm) 15 ~ 88 35 ~ 40 45 ~ 60 73 ~ 78 75 ~ 80

Indoor unit pipe

Taper nut

Connecting pipe

Spanner

Torgue wrench

Wrap the Piping
1. Use the insulation sleeve to wrap the joint part the indoor unit and the connection pipe, and then use insulating material to pack and seal insulation pipe, to prevent generation of condensate water on the joint part.
2. Connect the water outlet with drain pipes, and make the connection pipe, cables, and the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables and drain hose. Run the pipe sloping downward.

Connecting Pipe Drain Hose and Cables
Plastic Strap

Fixing the Indoor Unit
1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit toward the peg board, until the hook is embedded in the slot and makes a “click” sound.

15

ENG

Wiring diagram

· If your air conditioner is provided with interconnection cord , the wiring of the indoor unit is connected in the factory, there is no need of connection.
· If the interconnection cord is not provided, connection is needed in accordance with the

After installation, check: 1. The screws whether have been fixed effectively, and there is no risk of loosening. 2. Connector of display board whether put in the right place and do not touch the terminal board. 3. Control box cover whether cover tightly.

Constant speed

Variable speed

Connector

To Outdoor unit

To Outdoor unit

If there is a connector, connect it directly.

To Outdoor unit

To Outdoor unit

NOTE: · This manual usually includes the wiring mode for the different kind of A/C. We cannot exclude the possibility that
some special type of wiring diagrams are not included. · The diagram are for reference only. If the entity is difference with this wiring diagram, please refer to the detailed
wiring diagram adhered on the unit which you purchased.

16

ENG
INSTALL OUTDOOR UNIT GAS R32
Dimension drawing of outdoor unit installation

50cm above

Space to the obstruction 30cm above

Air inside 10cm above
50cm above Space to the obstruction

Space to the obstruction
200cm above
Air outside

Left installation feet
Air inlet

Right installation feet

Air outlet

Installation outdoor unit bolt
Outdoor Unit Size of Shape W1(W2) x H x D (mm) 665(710)x420x280 600(645)x485x260 660(710)x500x240 700(745)x500x255 730(780)x545x285 760(810)x545x285 790(840)x550x290 800(860)x545x315
800(850)x590(690)x310 825(880)x655x310 900(950)x700x350 900(950)x795x330 970(1044)x803x395

A (mm)
430 400 500 460 540 540 545 545 540 540 630 535 675

B (mm)
280 290 260 260 280 280 300 315 325 335 350 350 409

Install the connection pipe

Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting pipe at the stop valve, and tighten the Taper nut with fingers. Then tighten the Taper nut with a torque wrench. When prolonging the piping, extra amount of refrigerant must be added so that the operation and performance of the air conditioner will not be compromised.

Piping length
5M
5-15M

Amount of refrigerant to be added

Not needed

CC12000Btu

16g/m

CC18000Btu

24g/m

Amount of refrigerant for
the unit
1 kg
2 kg

Stop valve Taper nut Connection pipe
Liquid side pipe Gas side pipe
Spanner

Note: 1. This table is for reference only. 2. The joints shall not be reused, unless after re-flaring the pipe. 3. After installation, check the stop valve cover whether be fixed effectively.

Stop valve cover

17

ENG
INSTALL OUTDOOR UNIT
Wiring Connection
1. Loosen the screws and remove E-parts cover from the unit. 2. Connect the cables respectively to the corresponding terminals of
the terminal board of the outdoor unit (see the wiring diagram), and if there are signals connected to the plug, just conduct butt joint. 3.Ground wire: Remove the grounding screw out of the electric bracket, cover the grounding wire end onto the grounding screw and screw it into the grounding hole. 4.Fix the cable reliably with fasteners (Pressing board). 5.Put the E-parts cover back in its original place and fasten it with screws.

E-parts cover

Wiring diagram
Constant speed

Variable speed

To power

To indoor unit

To indoor unit

To power

To power

To indoor unit Connector

To indoor unit

To power

If there is a connector, connect it directly.
Note: · This manual usually includes the wiring mode for the different kind of A/C. We cannot exclude the possibility
that some speciaI type of wiring diagrams are not included. · The diagram are for reference only. If the entity is difference with this wiring diagram, please refer to the detailed
wiring diagram adhered on the unit which you purchased.

18

ENG

Vacuuming (Gas R32)

Exclusive R32 refrigerant pump must be used in making R32 refrigerant vacuum.

Before working on the air conditioner, remove the cover of the stop valve(gas and liquid valves)and be sure to retighten it afterward.(to prevent the potential air leakage).
1. To prevent air leakage and spilling tighten all connecting nut of all flare tubes.
2. Connect the stop valve, charge hose, manifold valve, and vacuum pump.
3. Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes and check that the compound vacuum gauge reads -0.1MPa (-76cmHg).
4. After applying vacuum, fully open the stop valve with a hex wrench.
5. Check that both indoor and outdoor connections are free of air leakage.

Compound meter -76cmHg Handle Lo
Charge hose

Pressure gauge Manifold valve Handle Hi
Charge hose

Vacuum pump

Stop valve Stop valve (liquid valve) (gas valve)

Outdoor condensation drainage (Heat pump type only)

When the unit is heating, the condensing water and defrosting water can be out reliably through the drain house. Installation: Install the outdoor drain elbow in 25 hole on the base plate, and joint the drain hose to the elbow, so that the waste water formed in the outdoor unit can be drained out to a proper plate.

Chassis Outdoor drain elbow

CHECK AFTER INSTALLATION AND TEST OPERATION

Check after installation
Electrical Safety Check 1. If the supply voltage is as required. 2. If there is any faulty or miss connection in each of the power, signal and grounding wires. 3. If the grounding wire of the air conditioner is securely grounded.
Installation Safety Check 1. If the installation is secure. 2. If the water drain is smooth. 3. If the wiring and piping are correctly installed. 4. Check that no foreign matter or tools are left inside the unit. 5. Check the refrigerant pipeline is protected well.
Leak test of the refrigerant Depending on the installation method, the following methods may be used to check for suspect leak, on areas such as the four connections of the outdoor unit and the cores of the cut-off valves and t-valves: 1. Bubble method: Apply of spray a uniform layer of soap water over the suspected leak spot and observe carefully
for bubble. 2. lnstrument method: Checking for leak by pointing the probe of the leak detector according to the instruction to
the suspect points of leak. Note: Make sure that the ventilation is good before checking.
19

ENG
Test Operation
· Verify that all piping and connection cables are well connected. · Confirm that the values at the gas side the liquid-side are fully open. · Connect the power cord to an independent power socket. · Install batteries in remote control. Note: Make sure that the ventilation is good before testing. Test Operation method: 1. Turn on the power and push the ON/OFF switch button of the remote controller to start the air conditioner. 2. Select COOL, HEAT (not available on cool-only models), SWING and other operation modes with the remote
controller and see if the operation is ok.

MAINTENANCE NOTICE

Attention: For maintenance or scrap, please contact authorized service centers. Maintenance by unqualified person may cause dangers. Feed air conditioner with R32 refrigerant, and maintain the air conditioner in strictly accordance with manufacturer’s requirements. The chapter is mainly focused on special maintenance requirements for appliance with R32 refrigerant. Ask repairer to read after-sales technical service handbook for detailed information.
Qualification requirements of maintenance personnel
1. Special training additional to usual refrigerating equipment repair procedures is required when equipment with flammable refrigerants is affected. In many countries, this training is carried out by national training organisations that are accredited to teach the relevant national competency standards that may be set in legislation. The achieved competence should be documented by a certificate.
2. The maintenance and repair of the air conditioner must be conducted according to the method recommended by the manufacturer. If other professionals are needed to help maintain and repair the equipment, it should be conducted under the supervision of individuals who have the qualification to repair AC equipped with flammable refrigerant.
Inspection of the Site
Safety inspection must be taken before maintaining equipment with R32 refrigerant to make sure the risk of fire is minimized. Check whether the place is well ventilated, whether anti-static and fire prevention equipment is perfect. While maintaining the refrigeration system, observe the following precautions before operating the system.
Operating Procedures
1.General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
2. Checking for presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, Le.non-sparking, adequately sealed or intrinsically safe.
3. Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
4. No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work shall
20

ENG
use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. `No Smoking’ signs shall be displayed. 5. Ventilated Area(open the door and window): Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. 6. Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: · The charge size is in accordance with the room size within which the refrigerant containing parts are installed. · The ventilation machinery and outlets are operating adequately and are not obstructed. · If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant. · Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. 7. Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: · That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking. · That no live electrical components and wiring are exposed while charging, recovering or purging the system. · Keep continuity of earthing.
Inspection of Cable
Check the cable for wear, corrosion, overvoltage, vibration and check if there are sharp edges and other adverse effects in the surrounding environment. During the inspection, the impact of aging or the continuous vibration of the compressor and the fan on it should be taken into consideration.
Leakage check of R32 refrigerant
Note: Check the leakage of the refrigerant in an environment where there is no potential ignition source. No halogen probe (or any other detector that uses an open flame) should be used. Leak detection method: For systems with refrigerant R32, electronic leak detection instrument is available to detect and leak detection should not be conducted in environment with refrigerant. Make sure the leak detector will not become a potential source of ignition, and is applicable to the measured refrigerant. Leak detector shall be set for the minimum ignitable fuel concentration (percentage) of the refrigerant. Calibrate and adjust to proper gas concentration (no more than 25%) with the used refrigerant. The fluid used in leak detection is applicable to most refrigerants. But do not use chloride solvents to prevent the reaction between chlorine and refrigerants and the corrosion of copper pipeline. If you suspect a leak, then remove all the fire from the scene or put out the fire. If the location of the leak needs to be welded, then all refrigerants need to be recovered, or, isolate all refrigerants away from the leak site (using cut-off valve). Before and during the welding, use OFN to purify the entire system.
21

ENG
Removal and Vacuum Pumping
1. Make sure there is no ignited fire source near the outlet of the vacuum pump and the ventilation is well. 2. Allow the maintenance and other operations of the refrigeration circuit should be carried out according to the
general procedure, but the following best operations that the flammability is already taken into consideration are the key. You should follow the following procedures: · Remove the refrigerant. · Decontaminate the pipeline by inert gases. · Evacuation. · Decontaminate the pipeline by inert gases again. · Cut or weld the pipeline. 3. The refrigerant should be returned to the appropriate storage tank. The system should be blown with oxygen free nitrogen to ensure safety. This process may need to be repeated for several times. This operation shall not be carried out using compressed air or oxygen. 4. Through blowing process, the system is charged into the anaerobic nitrogen to reach the working pressure under the vacuum state, then the oxygen free nitrogen is emitted to the atmosphere, and in the end, vacuumize the system. Repeat this process until all refrigerants in the system is cleared. After the final charging of the anaerobic nitrogen, discharge the gas into the atmosphere pressure, and then the system can be welded. This operation is necessary for welding the pipeline.
Procedures of Charging Refrigerants
As a supplement to the general procedure, the following requirements need to be added: – Make sure that there is no contamination among different refrigerants when using a refrigerant charging device.
The pipeline for charging refrigerants should be as short as possible to reduce the residual of refrigerants in it. – Storage tanks should remain vertically up. – Make sure the grounding solutions are already taken before the refrigeration system is charged with refrigerants. – After finishing the charging (or when it is not yet finished), label the mark on the system. – Be careful not to overcharge refrigerants.
Scrap and Recovery
Scrap: Before this procedure, the technical personnel shall be thoroughly familiar with the equipment and all its features, and make a recommended practice for refrigerant safe recovery. For recycling the refrigerant, shall analyze the refrigerant and oil samples before operation. Ensure the required power before the test. 1.Be familiar with the equipment and operation. 2.Disconnect power supply. 3.Before carrying out this process, you have to make sure: · If necessary, mechanical equipment operation should facilitate the operation of the refrigerant tank. · All personal protective equipment is effective and can be used correctly. · The whole recovery process should be carried out under the guidance of qualified personnel. ·The recovering of equipment and storage tank should comply with the relevant national standards. 4. lf possible, the refrigerating system should be vacuumized. 5. If the vacuum state can’t be reached, you should extract the refrigerant in each part of the system from many
places. 6. Before the start of the recovery, you should ensure that the capacity of the storage tank is sufficient. 7. Start and operate the recovery equipment according to the manufacturer’s instructions. 8. Don’t fill the tank to its full capacity (the liquid injection volume does not exceed 80% of the tank volume). 9. Even the duration is short, it must not exceed the maximum working pressure of the tank. 10. After the completion of the tank filling and the end of the operation process, you should make sure that the
tanks and equipment should be removed quickly and all closing valves in the equipment are closed. 11. The recovered refrigerants are not allowed to be injected into another system before being purified and tested. Note: The identification should be made after the appliance is scrapped and refrigerants are evacuated. The identification should contain the date and endorsement. Make sure the identification on the appliance can reflect the flammable refrigerants contained in this appliance.
22

ENG Recovery: 1. The clearance of refrigerants in the system is required when repairing or scrapping the appliance. It is
recommended to completely remove the refrigerant. 2. Only a special refrigerant tank can be used when loading the refrigerant into the storage tank. Make sure the
capacity of the tank is appropriate to the refrigerant injection quantity in the entire system. All tanks intended to be used for the recovery of refrigerants should have a refrigerant identification (i.e. refrigerant recovery tank). Storage tanks should be equipped with pressure relief valves and globe valves and they should be in a good condition. If possible, empty tanks should be evacuated and maintained at room temperature before use. 3. The recovery equipment should be kept in a good working condition and equipped with equipment operating instructions for easy access. The equipment should be suitable for the recovery of R32 refrigerants. Besides, there should be a qualified weighting apparatus which can be normally used. The hose should be linked with detachable connection joint of zero leakage rate and be kept in a good condition. Before using the recovery equipment, check if it is in a good condition and if it gets perfect maintenance. Check if II electrical components are sealed to prevent the leakage of the refrigerant and the fire caused by it. If you have any question, please consult the manufacturer. 4. The recovered refrigerant shall be loaded in the appropriate storage tanks, attached with a transporting instruction, and returned to the refrigerant manufacturer. Don’t mix refrigerant in recovery equipment, especially a storage tank. 5. The space loading R32 refrigeration can’t be enclosed in the process of transportation. Take anti electrostatic measures if necessary in transportation. In the process of transport, loading and unloading, necessary protective measures must be taken to protect the air conditioner to ensure that the air conditioner is not damaged. 6. When removing the compressor or clearing the compressor oil, make sure the compressor is pumped to an appropriate level to ensure that there is no residual R32 refrigerants in the lubricating oil. The vacuum pumping should be carried out before the compressor is returned to the supplier. Ensure the safety when discharging oil from the system.
23

ENG

REMOTE CONTROLLER INSTRUCTIONS

· Carefully read the instructions for safe and correct use of the air- conditioner. · Carefully keep the instructions as it can be referred to at any time.
Buttons description
· Type: A shown as
· Type: B shown as
· Type: A shown as
· Type: B shown as
NOTE
1. There are two different display types of remote control ( type A and type B} , whichever is the actual type.
2. The remote controller display all symbols during power-on, other time only display symbols corresponding to current operation.

1. ON/OFF button Press this button to turn on/off the unit. This will clear the existing timer and sleep settings.

2. MODE Button

Press this button, you can select operation mode as follows:

AUTO

COOL

DRY

HEAT

FAN

NOTE

Heat mode is not available for cool only units. Please read the Usage for Mode for a detailed description.

3. TIMER Button · With the unit on, press this button to set off timer or with it off to set on timer.
· Press this button once, the “ON(OFF)” will flash. Press ” + “or ” – ” to set the number of hours in which the unit will be turned on/off, with an interval of 0.5 hour, and a range of 0.5-24 hours.
· Press it again to confirm the setting, the “ON (OFF)” will stop flashing.
· If the “TIMER” button is not pressed within 10 seconds after the “ON (OFF)” start flashing, the timer setting will be exited.
· If a timer setting is confirmed, press this button again will cancel it.

24

ENG
4. HEAT Button Press this button to enter “HEAT” mode.

5. COOL Button Press this button to enter “COOL” mode.

6. SPEED Button Press this button, you can select fan speed as follows:

Low

Mid

High

Turbo

Auto

NOTE

Auto air speed is not available in fan mode. Turbo air speed is not available in auto mode. This button is invalid in dry mode.

7. + & – Button · Each time the ” + ” is pressed, the temperature setting will increase by 1°C (1°F) and each time the” – “is pressed,
it will decrease by 1°C (1°F).
· The temperature setting range: 16°C (60°F) ~ 32°C(90°F).

NOTE The temperature cannot be set in auto or fan mode.

8. MENU & OK Button · Press the “MENU” button to enter the function selection mode.
Then press , , and to choose the function which you want. After, press the “OK” button, turn on this function. · In function selection mode, press , , and , the character in LCD will be flashing if the function can be selected.
9. L/R SWING Button Press this button to activate left/right swing and press it again to turn off the swing function.
10. U/D SWING Button Press this button to activate up/down swing and press it again to turn off the swing function.

NOTE
· When the unit is on, press the “U/D SWING” button and hold for 3 seconds, the button will shift to be the functional button of “Rated swinging”, and then press the “U/D SWING” button to select the positions of Rated swinging.
· Only by pressing the “U/D SWING” button again and hold for 3 seconds or reinstall the battery of the remote control, can the “U/D SWING” button resume its original function. The power on/off button of the remote control can not enable the exit of the “Rated swinging” function.
11. HEALTH When the unit is on, press the “MENU” button ,then press , , and to choose “HEALTH” character, when the “HEALTH” character will blink, and press the “OK” button to highlight (not highlight) the “HEALTH” character, which will activate (deactivate) the health function.
12. ECO · In the cooling mode, the variable frequency air-conditioner will enter the ECO mode, which consumes the least
electricity, and exit it automatically 8 hours after. · The ECO mode is not available on the fixed frequency air conditioner. · Changing modes or turning off the remote controller will automatically cancel the ECO function.

25

ENG

· In the cooling mode, press the “MENU” button, then press , , and to choose the “ECO”character, when the “ECO” character will blink, and press the “OK” button to highlight (not highlight) the “ECO” character , which will activate (deactivate) the ECO function.

NOTE

The electricity consumption is affected by the ambient temperature and the house structure etc., and when the ambient temperature is high or the house has a large area, be cautious to use the ECO mode.

13. SLEEP
· When the unit is on, press the “MENU” button, then press , , and to choose the “SLEEP” character, when the “SLEEP” character will blink, and press the “OK” button to highlight (not highlight ) the “SLEEP” character , which will activate (deactivate) the function of sleep mode.
· The unit will exit SLEEP mode after 10 hours of continuous operation and restore to the previous status.

NOTE

The sleep function cannot be activated in fan or auto mode. In the sleep mode, the screen of the air-conditioner is off.

14. SILENCE When the unit is on, press the “MENU” button, then press , , and to choose the “SILENCE” character, when the “SILENCE” character will blink, and press the “OK” button to highlight (not highlight ) the “SILENCE” character , which will activate (deactivate) the function of silent wind.
15. ELE.H · When the unit is on, press the “MENU” button, then press , , and to choose the “ELE.H” character,
when the “ELE.H” character will blink, and press the “OK” button to highlight (not highlight ) the “ELE.H” character , which will activate (deactivate) the function of auxiliary heating. · The unit will activate the auxiliary heating function automatically according to the ambient temperature, so as to accelerate the heating. · This button is disabled on some models.

16. DISPLAY Press the “MENU” button, then press , , and to choose the “DISPLAY” character, when the character “DISPLAY” will blink, and press the “OK” button to activate (deactivate) the function of screen display.

17. LIGHT · The unit will activate or deactivate automatically the function of display on the air-conditioner screen according
to the indoor ambient brightness.
· When the unit is on, press the “MENU” button, then press , , and to choose the “LIGHT” character, when the “LIGHT” character will blink, and press the “OK” button to highlight (not highlight) the character “LIGHT”, which will activate (deactivate) the function of light sensing.

18. COSY (Only Type A)
· When the air-conditioner is on under the modes of cooling, press the “MENU” button, then press , , and
to choose the “COSY” character , when the “COSY” character will blink, and press the “OK”button to highlight (not highlight) the character “COSY”, which will activate (deactivate) the function of cleaning.
· When the “COSY” function is on, the fan speed is auto and it will cancel the swinging funcution. When the “COSY” function is on, these operations that turn off the unit, change the mode, and set SLEEP, fan speed, swinging function will automatically exit the”COSY” function, then restore to the previous status.

19. HUMI (Only Type A) Press the “MENU” button, then press , , and to choose the “HUMI” character, when the “HUMI” character will blink, and press the “OK” button to highlight (not highlight) the “HUMI” character , which will activate(deactivate) the humidifying function.
NOTE The humidifying function is not available under the dry mode.

26

ENG
20. iCLEAN · The unit will clean automatically the dusts on the evaporator and dry or blow-dry the moisture. · When the air-conditioner is off, press the “MENU” button, then press , , and to choose the “iCLEAN”
character , when the “iCLEAN” character will blink, and press the “OK” button to highlight ( not highlight) the character “iCLEAN”, which will activate (deactivate) the function of cleaning. · The cleaning function will close automatically after 30 minutes.

21. Child-lock · Press the “HEAT” and “MODE” buttons at the same time and hold for at least 3 seconds to activate or deactivate
the child-lock function.
· When the child-lock function is activated, the remote control will indicate ” “.

22. Anti-F (Only Type B) · Anti-F function: When the unit is closed under the modes of cooling, dry or auto (cooling), it will continue to
operate for about 3 minutes to dry the moisture on the evaporator, so as to prevent the accumulation of bacteria on the evaporator, which causes fungus and strange smell and is harmful to the health.
· When the unit is off, press the “MENU” button, then press , , and to choose the “Anti-F” character , when the “Anti-F” character will blink, and press the “OK” button to highlight (not highlight) the “Anti-F” character , which will activate (deactivate) the Anti-F function.

23. I-FEEL (Only Type B) When the unit is on, press the “MENU” button, then press , , and to choose the “I-FEEL” character, when the “I-FEEL” character will blink, and press the “OK” button to highlight (not highlight ) the “I-FEEL” and ” ” character , which will activate (deactivate) the I-FEEL function .

24. °C/°F · The temperature is displayed by default in Celsius.
· Press the “COOL” and “HEAT” buttons at the same time above 3 seconds, you can set the “°C ” or “°F “.

NOTE

Temperature display in Fahrenheit is not available for some models. When temperature is displayed in Fahrenheit on the remote controller, it might be in Celsius on the unit, the function and operation of which will not be affected.

25. 8° C heating function · 8°C heating function is only available for some models · Only in the heating mode in the power-on state, press the “MODE” and “+” buttons at the same time above 3
seconds to turn on or off the 8°C heating function. · After turning on the 8°C heating function:
a. Press the “HEAT” button, or switch to mode, or select the sleep function, all can exit 8°C heating function. b. Press the “SPEED”,”+”,”-” button is all non-effective. c. Fahrenheit/Celsius switching function is non-effective. d. Turn off and on the unit again, 8°C heating function is still retained. e. Press the “MENU” button, ELE.H function is not selectable.
Auto operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press the “MODE” button, select auto operation mode. 3. By pressing the “SPEED” button, you can select fan speed from Low, Mid, High, Auto. 4. Press the “ON/OFF” button again, the air-conditioner stops.
NOTE In the auto mode, the temperature settings is non-effective.

27

ENG
Cool/Heat operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press the “MODE” button, select cool or heat operation mode. 3. By pressing the ” + “or” – “button, you can set temperature from 16°C (60°F) to 32°C(90°F), the display changes
as you press the button. 4. By pressing the “SPEED” button, you can select fan speed from Low, Mid, High, Turbo, Auto. 5. Press the “ON/OFF” button again, the air-conditioner stops.
NOTE The cold wind type has no heating function.
Fan operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press the “MODE” button, select fan operation mode. 3. By pressing the “SPEED” button, you can select fan speed from Low, Mid, High. 4. Press the “ON/OFF” button again, the air-conditioner stops.
NOTE In the fan mode, the temperature settings is non-effective.
Dry operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press the “MODE” button, select dry operation mode. 3. By pressing the ” + “or” – “button, you can set temperature from 16°C (60°F) to 32°C(90°F), the display changes
as you press the button. 4. Press the “ON/OFF” button again, the air- conditioner stops.
NOTE In the dry mode, the speed settings is non-effective.
Usage
Fix batteries
1. Slide to open the battery cover according to the direction indicated by the arrowhead. 2. lnsert two brand new batteries (7#), and position the batteries to the right electric poles(+&-). 3. Put back the battery cover.
Smart WiFi app user manual can be found at: https://tesla.info/wp- content/uploads/pdf/TeslaTAWiFiapp.pdf