TESLA TA36QQCT-1232IAWT Series Split Type Air Conditioner User Manual
- June 1, 2024
- Tesla
Table of Contents
- TESLA TA36QQCT-1232IAWT Series Split Type Air Conditioner
- Product Information
- Product Usage Instructions
- Frequently Asked Questions
- OPERATING INSTRUCTION
- SAFETY PRECAUTIONS
- NOTICES FOR USE
- NAMES OF EACH PART
- CLEAN AND CARE
- TROUBLESHOOTING
- NOTICES FOR INSTALLATION
- CHECK AFTER INSTALLATION AND TEST OPERATION
- MAINTENANCE NOTICE
- REMOTE CONTROLLER INSTRUCTIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESLA TA36QQCT-1232IAWT Series Split Type Air Conditioner
Product Information
Specifications:
- Model Variants: TA36QQCT-1232IAWT, TA36QQDT-1232IAWT, TA36QQAT-1232IAT, TA36QAAT-1232IAW, TA37QABT-1232IAWUV, TA35QQET-1232IHWT, TA35QQFT-1232IHWT, TA35QQFT-1232IHWTUV, TA53QQCT-1832IAWT, TA53QQET-1832IHWT, TA53QQFT-1832IHWT, TA73QQCT-2432IAWT, TA72QQET-2432IHWT, TA72QQFT-2432IHWT
- Refrigerant: R32
- Inverter: DC Inverter
Product Usage Instructions
Safety Precautions:
Incorrect installation or operation may cause harm or damage. Follow these safety precautions:
- WARNING! – Possibility of death or serious injury.
- CAUTION! – Possibility of injury or damage to properties.
Grounding:
The air conditioner must be properly grounded. Incomplete grounding may result in electric shocks. Do not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire. Seek assistance from a qualified person.
R32 Flammable Refrigerant:
Warning: This air conditioner uses R32 flammable refrigerant. Handle with care as it may cause harm if roughly treated.
Symbols:
- Note WARNING: – This symbol indicates the appliance uses a flammable refrigerant.
- CAUTION CAUTION: – Service personnel should handle the equipment with reference to the installation manual.
- Symbol: – Information available in operating or installation manual.
Frequently Asked Questions
- Q: Is it mandatory to ground the air conditioner?
- A: Yes, the air conditioner must be properly grounded to avoid electric shocks and ensure safety.
- Q: Can I use the air conditioner without reading the manual?
- A: It is highly recommended to read the manual thoroughly before operating the unit to prevent any potential harm or damage.
SPLIT-TYPE AIR CONDITIONER
USER MANUAL
For R32 DC Inverter models:
TA36QQCT-1232IAWT TA36QQDT-1232IAWT TA36QQAT-1232IAT TA36QAAT-1232IAW TA37QABT-1232IAWUV TA35QQET-1232IHWT TA35QQFT-1232IHWT TA35QQFT-1232IHWTUV
TA53QQCT-1832IAWT TA53QQET-1832IHWT TA53QQFT-1832IHWT TA73QQCT-2432IAWT TA72QQET-2432IHWT TA72QQFT-2432IHWT
ENG
BIH/ MNE
BG
GR
HR
HU MKD RO SLO SRB
Ver. 2024
ENG
OPERATING INSTRUCTION
Note: All the pictures in this manual are just schematic diagrams, the actual is the standard. Please read this owner’s manual carefully and thoroughly before operating the unit! Take care of this manual for future reference.
BIH/ MNE
UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo
za upotrebu prije koriscenja ureaja! Sacuvajte ovo uputstvo za buducu
upotrebu.
BG
: , . , !
GR
: , . ! .
HR
UPUTE ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo shematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljito procitate ovo
uputstvo za upotrebu prije koristenja ureaja! Cuvajte ovaj prirucnik za buduce
koristenje.
HU
FELHASZNÁLÓI KÉZIKÖNYV
Megjegyzés: A kézikönyvben található képek csak sematikus ábrák, az aktuális a
szabvány. Kérjük, figyelmesen olvassa el ezt a kézikönyvet mieltt mködtetné az
eszközt! rizze meg ezt a kézikönyvet a késbbiekre is.
MKD
: , . ! .
RO
MANUAL DE UTILIZARE
Nota: Fotografiile din acest manual sunt doar diagrame schematice. V rugm s
citii “Manualul de Utilizare” cu atenie, înainte de a utiliza aerul
condiionat, pentru a asigura funcionarea corespunztoare. Pstrai manualul
pentru referine ulterioare.
SLO
PRIROCNIK ZA UPORABO
Opomba: Vse slike v tem prirocniku so le shematske risbe, dejansko stanje je
standard. Prosimo, da pred uporabo skrbno in temeljito preberete ta prirocnik
za uporabo! Prirocnik shranite za kasnejso uporabo.
SRB
UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo
za upotrebu pre koriscenja ureaja! Sacuvajte ovo uputstvo za buducu upotrebu.
ENG
WARNING
Warning: This air conditioner uses R32 flammable refrigerant.
Notes: Air conditioner with R32 refrigerant, if roughly treated, may cause
serious harm to the human body or surrounding things.
· The room space for the installation, use, repair, and storage of this air
conditioner should be greater than 5 m’. · Air conditioner refrigerant can not
charge more than 1. 7kg. · Do not use any methods to speed up defrost or to
clean frosty parts except for particular recommended by
manufacturer. · Not pierce or burn air conditioner, and check the refrigerant
pipeline wether be damaged. · The air conditioner should be stored in a room
without lasting fire source, for example, open flame, burning gas
appliance, working electric heater and so on. · Notice that the refrigerant
may be tasteless. · The storage of air conditioner should be able to prevent
mechanical damage caused by accident. · Maintenance or repair of air
conditioners using R32 refrigerant must be carried out after security check to
minimize risk of incidents. · Air conditioner must be installed with stop
valve cover. · Please read the instruction carefully before installing, using
and maintaining.
Symbol
Note WARNING
Explanation
This symbol shows that this appliance uses a flammable refrigerant.If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of fire.
CAUTION
This symbol shows that the operation manual should be read carefully.
CAUTION CAUTION
This symbol shows that a service personnel should be handling this equipment
with reference to the installation manual.
This symbol shows that information is available such as the operating manual
or installation manual.
SAFETY PRECAUTIONS
Incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc. The seriousness is classified by the following indications:
WARNING!
This symbol indicates the possibility of death or serious injury.
CAUTION!
This symbol indicates the possibility of injury or damage to properties.
3
ENG
WARNING!
· This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (Only for the AC with CE-MARKING)
· This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (Except for the AC with CE-MARKING)
·
The air conditioner must be grounded. Incomplete grounding may result in electric shocks. Do
not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire.
· Always switch off the device and cut the power supply when the unit is not in use for long time so as to ensure safety.
· Take care not let the remote control and the indoor unit watered or being too wet. Otherwise, it may cause short circuit.
· If the power supply cable is damaged, it must be replaced by manufacture or its service agent or a similar
qualified person.
· Don’t cut off main power switch during operating or with wet hands. It may cause electric shock.
· Don’t share the socket with other electric appliance. Otherwise, it may cause electric shock even fire and explosion.
· Always switch off the device and cut the power supply before performing any maintenance or cleaning.
Otherwise, it may cause electric shock or damage.
· Don’t pull the power cord when pull out the power plug. The damage of pulling power cord will cause serious
electric shock.
· A warning that ducts connected to an appliance shall not contain an ignition source.
· Don’t install air conditioner in a place where there is flammable gas or liquid. The distance between them should above 1m. It may cause fire even explosion.
· Don’t use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either.
Doing this may cause electric shock or damage to the unit.
· Don’t attempt to repair the air conditioner by yourself. Incorrect repairs may cause fire or explosion. Contact a
qualified service technician for all service requirement.
· Don’t use air conditioner in lightning strom weather. Power supply should be cut in time to prevent the occurrence of danger.
· Don’t put hands or any objects into the air inlets or outlets. This may cause personal injury or damage to the unit.
· Please note whether the installed stand is firm enough or not. If it is damaged, it may lead to the fall of the unit and cause the injury.
· Don’t block air inlet or air outlet. Otherwise, the cooling or heating capacity will be weakened, even cause system stop operating.
· Don’t let the air conditioner blow against the heater appliance. Otherwise it will lead to incomplete combustion, thus causing poisoning.
· The appliance shall be installed in accordance with national wiring regulations.
· An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks.
· This product contains fluorinated greenhouse gases.
· Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
· Ensure no following objects under the indoor unit: 1. microwaves, ovens and other hot objects. 2. computers and other high electrostatic appliances. 3. sockets that plug frequently.
· The joints between indoor and outdoor unit shall not be reused, unless after re-flaring the pipe.
· The specification of the fuse are printed on the circuit bord, such as: 3.15A/250V AC, etc.
4
ENG
WEEE Warning
Meaning of crossed out wheeled dustbin: Do not dispose of electrical
appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food
chain, damaging yourhealth and well-being. When replacing old appliances with
new ones, the retailer is legally obligated to take back your old appliance
for disposals at least free of charge.
CAUTION!
· Don’t open the windows and doors for long time when the air conditioner is
running. Otherwise, the cooling or heating capacity will be weakened.
· Don’t stand on the top of the outdoor unit or place heavy things on it. This
cloud cause personal injuries or damage the unit.
· Don’t use the air conditioner for other purposes, such as drying clothes,
preserving foods,etc.
· Don’t apply the cold air to the body for a long time. It will deteriorate
your physical conditions and cause health problems.
· Set the suitable temperature. It is recommended that the temperature
difference between indoor and outdoor temperature should not be too large.
Appropriate adjustments of the setting temperature can prevent the waste of
electricity.
· If your air conditioner is not fitted with a supply cord and a plug, an
anti-explosion all-pole switch must be installed in the fixed wiring and the
distance between contacts should be no less than 3.0 mm.
· If your air conditioner is permanently connected to the fixed wiring, a
anti-explosion residual current device (RCD) having rated residual operating
current not exceeding 30 mA should be installed in the fixed wiring.
· The power supply circuit should have leakage protector and air switch of
which the capacity should be more than1 .5 times of the maximum current.
· Regarding the installation of the air conditioners, please refer to the
below paragraphs in this manual.
NOTICES FOR USE
The conditions of unit can’t normally run
· Within the temperature range provided in following table, the air
conditioner may stop running and other anomalies may arise.
Cooling
Outdoor Indoor
43°C (Apply to T1) >52°C (Apply to T3)
<18°C
Heating
Outdoor Indoor
24°C <-7°C
27°C
· When the temperature is too high, the air conditioner may activate the
automatic protection device, so that the air conditioner could be shut down.
· When the temperature is too low, the heat exchanger of the air conditioner
may freeze, leading to water dripping or other malfunction.
· In long-term cooling or dehumidification with a relative humidity of above
80% (doors and windows are open), there may be water condenses or dripping
near the air outlet.
· T1 and T3 refer to ISO 5151.
5
ENG
Notes for heating
· The fan of the indoor unit will not start running immediately after the
heating is started to avoid blowing out cool air.
· When it is cold and wet outside, the outdoor unit will develop frost over
the heat exchanger which will increased the heating capacity. Then the air
conditioner will start defrost function.
· During defrost, the air conditioner will stop heating for about 5-12
minutes. · Vapor may come out from the outdoor unit during defrost. This is
not a malfunction, but a result of fast defrost. · Heating will resume after
defrost is complete.
Notes for turning off
· When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.
Emergency operation
· If the remote controller is lost or broken, use force switch button to
operate the air conditioner.
· If this button is pushed with the unit OFF, the air conditioner will operate
in Auto mode.
· If this button is pushed with the unit ON, the air conditioner will stop
running.
Force switch
Airflow direction adjustment
1. Use up-down swing and left-right swing buttons on the remote controller to
adjust the airflow direction. Refer to the operation manual of the remote
controller for detail.
2. For models without left-right swing function, the fins has to be moved
manually.
Note: Move the fins before the unit is in operation, or your finger might be
injured. Never place your hand into the air inlet or outlet when the air
conditioner is in operation.
Specific caution
1.Open front panel of the indoor. 2. The connector (as Fig) can not touch the
terminal
board, and is positioned as shown in Fig.
Connector
Cable 1 Cable 2 Terminal board
6
NAMES OF EACH PART
Air inlet grille Panel
Indoor unit
Air inlet
Air filter
Air louver Air vent
Air outlet
ENG Force switch
Pipe protection ring
Remote controller
Outdoor unit
Power cable
Air outlet grille
Connecting pipe Drain hose
Air outlet Note: All the pictures in this manual are just schematic diagrams,
the actual is the standard. Plug, WiFi function, Negative-ion function, and
vertical and horizontal; swing function both are optional.
7
CLEAN AND CARE
WARNING! · Before the cleaning of the air conditioner, it must be shut down
and the electricity must be cut off for more than
5 minutes, otherwise there might be the risk of electric shocks. · Do not wet
the air conditioner, which can cause an electric shock. Make sure not to rinse
the air conditioner with
water under any circumstances. · Volatile liquids such as thinner or gasoline
will damage the air conditioner housing, therefore please clean the
housing of air conditioner only with soft dry cloth and damp cloth moistened
with neutral detergent. · In the course of the using, pay attention to
cleaning the filter regularly, to prevent the covering of dust which
may affect the effect. If the service environment of the air conditioner is
dusty, correspondingly increase the number of times of cleaning. After
removing the filter, do not touch the fin part of the indoor unit with the
finger, and no force to damage the refrigerant pipeline.
Clean the panel
When the panel of the indoor unit is contaminated, clean it gently with a
wrung towel using tepid water below 40°C, and do not remove the panel while
cleaning.
Clean the air filter
Remove the air filter
1. Use both hands to open the panel for an angle from both ends of the panel
in accordance with the direction of the arrow.
2. Release the air filter from the slot and remove it.
Clean the Air Filter Use a vacuum cleaner or water to rinse filter, and if the
filter is very dirty (for example, with greasy dirt), clean it with warm water
(below 45 °C) with mild detergent dissolved in, and then put the filter in the
shade to dry in the air.
Mount the Filter 1. Reinstall the dried filter in reverse order of removal,
then cover and lock the panel.
Check before use
1. Check whether all the air inlets and outlets of the units are unblocked.
2. Ceck whether there is blocking in the water outlet of the drain pipe, and
immediately clean it up if any. 3. Check the ground wire is reliably grounded.
4. Check whether the remote control batteries are installed, and whether the
power is sufficient. 5. Check whether there is damage in the mounting bracket
of the outdoor unit, and if any, please contact our local
service center.
8
ENG
Maintain after use
1. Cut off the power source of the air conditioner, turn off the main power
switch and remove the batteries from the remote controller.
2. Clean the filter and the unit body. 3. Remove the dust and debris from the
outdoor unit. 4. Check whether there is damage in the mounting bracket of the
outdoor unit, and if any, please contact our local
service center.
CAUTION!
Do not repair the air conditioner by yourself as wrong maintenance may cause
electric shock or fire or explode, please contact the authorized service
center and let the professionals conduct the maintenance, and checking the
following items prior to contacting for maintenance can save your time and
money.
TROUBLESHOOTING
Phenomenon
The air conditioner does not work.
The air conditioner can’t run after the immediate start-up after it is shut
down. The air conditioner stops running after it starts up for a while.
The wind blows out, but the cooling/ heating effect is not good.
The indoor unit blows out odor. There is sound of running water during the
running of air conditioner.
Troubleshooting
· There might be power outages. Wait until power is restored. · Power plug may
be loose out from the socket. The plug in the plug tightly. · Power switch
fuse may blow. Replace the fuse. · The time for timing boot is yet to come.
Wait or cancel the timer settings.
· If the air conditioner is turned on immediately after it is turned off, the
protective delay switch will delay the operation for 3 to 5 minutes.
· May reach the setting temperature. It is a normal function phenomenon. · May
be at a defrosting state. It will automatically restore and run again after
defrosting. · Shutdown Timer may be set. If you continue to use, please turn
it on again.
· Excessive accumulation of dust on filter, blocking at air inlet and outlet,
and the excessively small angle of the louver blades all will affect the
cooling and heating effect. Please clean the filter, remove the obstacles at
the air inlet and outlet and regulate the angle of the louver blades.
· Poor cooling and heating effect caused by doors and windows opening, and
unclosed exhaust fan. Please close the doors, windows, the exhaust fan, etc.
· Auxiliary heating function is not turned on while heating, which may lead to
poor heating effect. Turn on the auxiliary heating function. (only for models
with auxiliary heating function)
· Mode setting is incorrect, and the temperature and wind speed settings are
not appropriate. Please re-select the mode, and set the appropriate
temperature and wind speed.
· The air conditioner itself does not have undesirable odor. If there is odor,
it may be due to accumulation of the odor in the environment. Clean the air
filter or activate the cleaning function.
· When the air conditioner is started up or stopped, or the compressor is
started up or stopped during the running, sometimes the “hissing” sound of
running water can be heard. This is the sound of the flow of the refrigerant,
not a malfunction.
9
ENG
Phenomenon A slight “click” sound is heard at the of start-up or shut-down.
The indoor unit makes abnormal sound.
There are water drops over the surface of the indoor unit.
During the cooling operation, the indoor unit outlet sometimes will blow out
mist.
Troubleshooting
· Due to temperature changes, panel and other parts will swell, causing the
sound of friction. This is normal, not a fault.
· The sound of fan or compressor relay switched on or off. · When the
defrosting is started or stop running, it will sound. That is due to the
refrigerant flowed to reverse direction. They are not malfunctions. · Too much
dust accumulation in the air filter of the indoor unit may result in
fluctuation of the sound. Clean the air filters in time. · Too much air noise
when “Strong wind” is turned on. This is normal, if feeling
uncomfortable, please deactivate the “Strong wind” function.
· When ambient humidity is high, water drops will be accumulated around the
air outlet or the panel, etc. This is a normal physics phenomenon.
· Prolonged cooling run in open space produces water drops. Close the doors
and windows.
· Too small opening angle of the louver blades may also result in water drops
at the air inlet. Increase the angle of the louver blades.
· When the indoor temperature and humidity are high, it happens sometimes.
This is because the indoor air is cooled rapidly. After it runs for some time,
the indoor temperature and humidity will be reduced and the mist will
disappear.
Immediately stop all operations and cut off the power supply, contact our
Service center locally in following situations.
· Hear any harsh sound or smell any awful odor during running. · Abnormal
heating of power cord and plug occurs. · The unit or remote controller has any
impurity or water. · Air switch or leakage protection switch is often
disconnected.
NOTICES FOR INSTALLATION
IMPORTANT NOTICES!
· Before installating, please contact with local authorized maintenance
cenler, if unit is not installed by the authorized maintenance center, the
malfunction may not solved,due to discommodious contact.
· The air conditioner must be installed by professionals according to the
national wiring rules and this manual. · Refrigerant leak tesf must be made
after installation. · To move and install air conditioner to another place,
please contact our local special service center.
Unpacking Inspection
· Open the box and check air conditioner in area with good ventilation (open
the door and window) and without ignition source. Note: Operators are required
to wear anti-static devices.
· It is necessary to check by professional whether there is refrigerant
leakage before opening tlie box of outdoor machine; stop installing the air
conditioner if leakage is found.
· The fire prevention equipment and anti-static precautions shall be prepared
well before checking.Then check the refrigerant pipeline to see if there is
any collision traces, and whether the outlook 1s good.
10
ENG
Safety Principles for Installing Air Conditioner
· Fire prevention device shall be prepared before installation. · Keep
installing site ventilated.(open the door and window) · Ignition
source,smoking and calling is not allowed to exist in area where R32
refrigerant rocated. · Anti-static precautions in necessary for installing air
conditioner, e.g. wear pure cotton clothes and gloves. · Keep leak detector in
working state during the installation. · If R32 refrigerant leakage occurs
during tfle installation, you shall immediately detect the concentration in
indoor
environment until it reaches a safe level. If refrigerant leakage affects the
performance of the air conditioner, please immediately stop the operation, and
the air conditioner must be vacuumed firstly and be returned to the
maintenance station for processing. · Keep electric appliance, power switch,
plug, socket, high temperature heat source and high static away from the area
underneath sidelines of the indoor unit. · The air conditioner shall be
installed in an accessible location to installation and maintenance, without
obstacles that may block air inlets or outlets of indoor/outdoor units, and
shall keep away from heat source inflammable or explosive conditions. · When
installing or repairing the air conditioner and the connecting line is not
long enough, the entire connecting line shall be replaced with the connecting
line of the original specification; extension is not allowed. · Use new
connection pipe, unless re-flaring the pipe.
Requirements For Installation Position
· Avoid places of inflammable or explosive gas leakage or where there are
strongly aggressive gases. · Avoid places subject to strong artificial
electric/magnetic fields. · Avoid places subject to noise and resonance. ·
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind,
direct sunshine or h1gli temperature
heat sources). · Avoid places within the reach of cnildren. · Shorten the
connection between the indoor and outdoor units. · Select where it is easy to
perform service and repair and where the ventilation good. · The outdoor unit
shalrnot be installed in any way that could occupy an aisle, stairway, exit,
fire escape, catwalk or
any other public area. · The outdoor unit shall be installed as far as
possible from the doors and windows of the neighbors as well as the
green plants.
Installation environment inspection
· Check nameRlate of outdoor unit to make sure whether the refrigerant is R32.
· Check the floor space of the room. The space shall not be less than usable
space(sm2 ) in the specification.The
outdoor unit shall be installed at a well-ventilated place. · Check the
surrounding environment of installation site: R32 shall not be installed in
the enclosed reserved space
of a building. · When using electric drill to make holes in the wall, check
first whether there is pre-buried pipeline for water,
electricity and gas. · It is suggested to use the reserved hole in the roof of
tfle walr
Requirements of the mounting structure
· The mounting rack must meet the relevant national or industrial standards in
terms of strength with welding and connection areas rustproofed.
· The mounting rack and its load carry surface shall be able to withstand 4
times or above the weight of the unit, or 200kg, whichever is heavier.
· The mounting rack of the outdoor unit shall be fastened with expansion bolt.
· Ensure the secure installation regardless of what type of wall on which it
is installed, to prevent potential
dropping that could hurt people.
11
ENG
Electrical Safety Requirements
· Be sure to use the rated voltage and air conditioners dedicated circuit for
the power supply, and the power cord diameter must meet the national
requirements.
· When the maximum current of air conditioner is 16A, it must use the air
switch or leakage protection switch equipped with protection devices.
· The operating range is 90%-110% of the local rated voltage. But insufficient
power supply malfunction, electrical shock, or fire. If the voltage
instability, proposed to increase the voltage regulator.
· The minimum clearance between the air conditioner and the combustibles is
1.5 m. · The interconnection cord connect the indoor and outdoor units. You
must first choose the right cable size
before preparing it for connection. · Cable Types: Outdoor Power Cable:
H07RN-F or H05RN-F;
Interconnection cord: H07RN-F or H05RN-F; · Minimum Cross-Sectional Area of
Power cable and interconnection cord.
North America
Appliance Amps (A)
10 13 18 25 30 40
AWG
18 16 14 12 10 8
Other regions
Rated Current of Appliance (A) >3 and 6 >6 and 10 >10 and 16 >10 and 16 >10 and 16 >10 and 16
Nominal Cross-Sectional Area (mm2) 0.75 1 1.5 2.5 4 6
· The size of the interconnection cord, power cable, fuse, and switch needed
is determined by the maximum current of the unit. The maximum current is
indicated on the nameplate located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse, or switch.
· Note: Core number of cable refer to the detailed wiring diagram adhered on
the unit which you purchased.
Requirements for operations at raised height
· When carrying out installation at 2m or higher above the base level, safety
belts must be worn and ropes of sufficient strength be securely fasten to the
outdoor unit, to prevent falling that could cause personal injury or death as
well as property loss.
Grounding Requirements
· The air conditioner is the class I electrical appliance and must ensure a
reliable grounding. · Do not connect the grounding wire to a gas pipe, water
pipe, lightning rod, telephone line, or a circuit poorly
grounded to the earth. · The grounding wire is specially designed and shall
not be used for other purpose, nor shall it be fastened with a
common tapping screw. · Interconnection cord diameter should be recommended as
per instruction manual ,and with type O terminal
that meet local standards (internal diameter of type O terminal needs to match
the screw size of the unit, no more than 4.2mm). After installation, check the
screws whether have been fixed effectively, and there is no risk of loosening.
12
ENG
Others
· The connection method of the air conditioner and the power cord and the
interconnection method of each independent element shall be subject to the
wiring diagram affixed to the machine.
· The model and rating value of the fuse shall be subject to the silkscreen on
corresponding controller or fuse sleeve.
Packing list
Packing list of the indoor unit
Name Indoor Unit Remote Controller Batteries (7#) Owner’s manual Drain pipe
Quantity Unit
1
Set
1
PC
2
PC
1
Set
1
PC
Packing list of the outdoor unit
Name
Outdoor Unit
Connecting pipe (optional)
Plastic Strap
Pipe Protection Ring
Luting (putty) (optional)
Quantity 1 2 1 1 1
Unit Set PC ROLL PC PACKET
Note: All accessories s hall be subject to actual packaging material, and if there is any difference, please understand.
INSTALL INDOOR UNIT
Dimension drawing of indoor unit installation
Space to the wall 20cm above
Space to the ceiling 15cm above
Space to the wall 20cm above
200-260cm Space to the floor
13
ENG
Mounting plate
1. The wall for installation of the indoor unit shall be hard and firm, so as
to prevent vibration.
2. Use the “+” type screw to fasten the peg board, horizontally mount the peg
board on the wall, and ensure the lateral horizontal and longitudinal
vertical.
3. Pull the peg board by hand after the installation, to confirm whether it
is solid.
Wall-through Hole
1. Make a hole with an electric hammer or a water drill at the predetermined
position on the wall for piping, which shall slant outwardly by 5° -10° .
2. To protect the piping and the cables from being damaged running through
the wall, and from the rodents that may inhabit in the hollow wall, a pipe
protecting ring shall be installed and sealed with putty.
Note: Usually, the wall hole is 60mm~80mm. Avoid preburied power wire and hard
wall when making the hole.
Putty
Pipe protection ring
Route of Pipeline
1. Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In the case of sideway routing, cut off the outlet cutting stock of the opposite side.
Fig 1
Connecting Pipe Drain Hose and Cables
Fig 2 Connecting Pipe Drain Hose and Cables
Outlet material preparation
14
ENG
Drain pipe connection
1. Remove the fixed part to pull out pipe of indoor machine from the case.
Screw the hexagon nut in the left of the joint to the end with your hand.
2. Connect the connecting pipe to the indoor unit: Aim at the pipe center,
tighten the Taper nut with fingers, and then tighten the Taper nut with a
torque wrench, and the direction is shown in diagram on the right. The torque
used is shown in the following table.
Note: Carefully check if there is any damage of joints before installation.
The joints shall not be reused, unless after re-flaring the pipe.
Tightening torque table
The size of pipe (mm) 6 / 6. 35 9 / 9. 52 12 / 12.7 15.88 19.05
Torque (Nm) 15 ~ 88 35 ~ 40 45 ~ 60 73 ~ 78 75 ~ 80
Indoor unit pipe
Taper nut
Connecting pipe
Spanner
Torgue wrench
Wrap the Piping
1. Use the insulation sleeve to wrap the joint part the indoor unit and the
connection pipe, and then use insulating material to pack and seal insulation
pipe, to prevent generation of condensate water on the joint part.
2. Connect the water outlet with drain pipes, and make the connection pipe,
cables, and the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables and drain
hose. Run the pipe sloping downward.
Connecting Pipe Drain Hose and Cables
Plastic Strap
Fixing the Indoor Unit
1. Hang the indoor unit on the peg board, and move the unit from left to
right to ensure that the hook is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit
toward the peg board, until the hook is embedded in the slot and makes a
“click” sound.
15
ENG
Wiring diagram
· If your air conditioner is provided with interconnection cord , the wiring
of the indoor unit is connected in the factory, there is no need of
connection.
· If the interconnection cord is not provided, connection is needed in
accordance with the
After installation, check: 1. The screws whether have been fixed effectively, and there is no risk of loosening. 2. Connector of display board whether put in the right place and do not touch the terminal board. 3. Control box cover whether cover tightly.
Constant speed
Variable speed
Connector
To Outdoor unit
To Outdoor unit
If there is a connector, connect it directly.
To Outdoor unit
To Outdoor unit
NOTE: · This manual usually includes the wiring mode for the different kind of
A/C. We cannot exclude the possibility that
some special type of wiring diagrams are not included. · The diagram are for
reference only. If the entity is difference with this wiring diagram, please
refer to the detailed
wiring diagram adhered on the unit which you purchased.
16
ENG
INSTALL OUTDOOR UNIT GAS R32
Dimension drawing of outdoor unit installation
50cm above
Space to the obstruction 30cm above
Air inside 10cm above
50cm above Space to the obstruction
Space to the obstruction
200cm above
Air outside
Left installation feet
Air inlet
Right installation feet
Air outlet
Installation outdoor unit bolt
Outdoor Unit Size of Shape W1(W2) x H x D (mm) 665(710)x420x280
600(645)x485x260 660(710)x500x240 700(745)x500x255 730(780)x545x285
760(810)x545x285 790(840)x550x290 800(860)x545x315
800(850)x590(690)x310 825(880)x655x310 900(950)x700x350 900(950)x795x330
970(1044)x803x395
A (mm)
430 400 500 460 540 540 545 545 540 540 630 535 675
B (mm)
280 290 260 260 280 280 300 315 325 335 350 350 409
Install the connection pipe
Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting pipe at the stop valve, and tighten the Taper nut with fingers. Then tighten the Taper nut with a torque wrench. When prolonging the piping, extra amount of refrigerant must be added so that the operation and performance of the air conditioner will not be compromised.
Piping length
5M
5-15M
Amount of refrigerant to be added
Not needed
CC12000Btu
16g/m
CC18000Btu
24g/m
Amount of refrigerant for
the unit
1 kg
2 kg
Stop valve Taper nut Connection pipe
Liquid side pipe Gas side pipe
Spanner
Note: 1. This table is for reference only. 2. The joints shall not be reused, unless after re-flaring the pipe. 3. After installation, check the stop valve cover whether be fixed effectively.
Stop valve cover
17
ENG
INSTALL OUTDOOR UNIT
Wiring Connection
1. Loosen the screws and remove E-parts cover from the unit. 2. Connect the
cables respectively to the corresponding terminals of
the terminal board of the outdoor unit (see the wiring diagram), and if there
are signals connected to the plug, just conduct butt joint. 3.Ground wire:
Remove the grounding screw out of the electric bracket, cover the grounding
wire end onto the grounding screw and screw it into the grounding hole. 4.Fix
the cable reliably with fasteners (Pressing board). 5.Put the E-parts cover
back in its original place and fasten it with screws.
E-parts cover
Wiring diagram
Constant speed
Variable speed
To power
To indoor unit
To indoor unit
To power
To power
To indoor unit Connector
To indoor unit
To power
If there is a connector, connect it directly.
Note: · This manual usually includes the wiring mode for the different kind of
A/C. We cannot exclude the possibility
that some speciaI type of wiring diagrams are not included. · The diagram are
for reference only. If the entity is difference with this wiring diagram,
please refer to the detailed
wiring diagram adhered on the unit which you purchased.
18
ENG
Vacuuming (Gas R32)
Exclusive R32 refrigerant pump must be used in making R32 refrigerant vacuum.
Before working on the air conditioner, remove the cover of the stop valve(gas
and liquid valves)and be sure to retighten it afterward.(to prevent the
potential air leakage).
1. To prevent air leakage and spilling tighten all connecting nut of all
flare tubes.
2. Connect the stop valve, charge hose, manifold valve, and vacuum pump.
3. Fully open the handle Lo of the manifold valve and apply vacuum for at
least 15 minutes and check that the compound vacuum gauge reads -0.1MPa
(-76cmHg).
4. After applying vacuum, fully open the stop valve with a hex wrench.
5. Check that both indoor and outdoor connections are free of air leakage.
Compound meter -76cmHg Handle Lo
Charge hose
Pressure gauge Manifold valve Handle Hi
Charge hose
Vacuum pump
Stop valve Stop valve (liquid valve) (gas valve)
Outdoor condensation drainage (Heat pump type only)
When the unit is heating, the condensing water and defrosting water can be out reliably through the drain house. Installation: Install the outdoor drain elbow in 25 hole on the base plate, and joint the drain hose to the elbow, so that the waste water formed in the outdoor unit can be drained out to a proper plate.
Chassis Outdoor drain elbow
CHECK AFTER INSTALLATION AND TEST OPERATION
Check after installation
Electrical Safety Check 1. If the supply voltage is as required. 2. If there
is any faulty or miss connection in each of the power, signal and grounding
wires. 3. If the grounding wire of the air conditioner is securely grounded.
Installation Safety Check 1. If the installation is secure. 2. If the water
drain is smooth. 3. If the wiring and piping are correctly installed. 4. Check
that no foreign matter or tools are left inside the unit. 5. Check the
refrigerant pipeline is protected well.
Leak test of the refrigerant Depending on the installation method, the
following methods may be used to check for suspect leak, on areas such as the
four connections of the outdoor unit and the cores of the cut-off valves and
t-valves: 1. Bubble method: Apply of spray a uniform layer of soap water over
the suspected leak spot and observe carefully
for bubble. 2. lnstrument method: Checking for leak by pointing the probe of
the leak detector according to the instruction to
the suspect points of leak. Note: Make sure that the ventilation is good
before checking.
19
ENG
Test Operation
· Verify that all piping and connection cables are well connected. · Confirm
that the values at the gas side the liquid-side are fully open. · Connect the
power cord to an independent power socket. · Install batteries in remote
control. Note: Make sure that the ventilation is good before testing. Test
Operation method: 1. Turn on the power and push the ON/OFF switch button of
the remote controller to start the air conditioner. 2. Select COOL, HEAT (not
available on cool-only models), SWING and other operation modes with the
remote
controller and see if the operation is ok.
MAINTENANCE NOTICE
Attention: For maintenance or scrap, please contact authorized service
centers. Maintenance by unqualified person may cause dangers. Feed air
conditioner with R32 refrigerant, and maintain the air conditioner in strictly
accordance with manufacturer’s requirements. The chapter is mainly focused on
special maintenance requirements for appliance with R32 refrigerant. Ask
repairer to read after-sales technical service handbook for detailed
information.
Qualification requirements of maintenance personnel
1. Special training additional to usual refrigerating equipment repair
procedures is required when equipment with flammable refrigerants is affected.
In many countries, this training is carried out by national training
organisations that are accredited to teach the relevant national competency
standards that may be set in legislation. The achieved competence should be
documented by a certificate.
2. The maintenance and repair of the air conditioner must be conducted
according to the method recommended by the manufacturer. If other
professionals are needed to help maintain and repair the equipment, it should
be conducted under the supervision of individuals who have the qualification
to repair AC equipped with flammable refrigerant.
Inspection of the Site
Safety inspection must be taken before maintaining equipment with R32
refrigerant to make sure the risk of fire is minimized. Check whether the
place is well ventilated, whether anti-static and fire prevention equipment is
perfect. While maintaining the refrigeration system, observe the following
precautions before operating the system.
Operating Procedures
1.General work area: All maintenance staff and others working in the local
area shall be instructed on the nature of work being carried out. Work in
confined spaces shall be avoided. The area around the workspace shall be
sectioned off. Ensure that the conditions within the area have been made safe
by control of flammable material.
2. Checking for presence of refrigerant: The area shall be checked with an
appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially toxic or flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with all
applicable refrigerants, Le.non-sparking, adequately sealed or intrinsically
safe.
3. Presence of fire extinguisher: If any hot work is to be conducted on the
refrigeration equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand. Have a dry powder or CO2
fire extinguisher adjacent to the charging area.
4. No ignition sources: No person carrying out work in relation to a
refrigeration system which involves exposing any pipe work shall
20
ENG
use any sources of ignition in such a manner that it may lead to the risk of
fire or explosion. All possible ignition sources, including cigarette smoking,
should be kept sufficiently far away from the site of installation, repairing,
removing and disposal, during which refrigerant can possibly be released to
the surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no flammable hazards
or ignition risks. `No Smoking’ signs shall be displayed. 5. Ventilated
Area(open the door and window): Ensure that the area is in the open or that it
is adequately ventilated before breaking into the system or conducting any hot
work. A degree of ventilation shall continue during the period that the work
is carried out. The ventilation should safely disperse any released
refrigerant and preferably expel it externally into the atmosphere. 6. Checks
to the refrigeration equipment: Where electrical components are being changed,
they shall be fit for the purpose and to the correct specification. At all
times the manufacturer’s maintenance and service guidelines shall be followed.
If in doubt, consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants: · The charge size is in accordance with the room size within
which the refrigerant containing parts are installed. · The ventilation
machinery and outlets are operating adequately and are not obstructed. · If an
indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant. · Refrigeration pipe or components
are installed in a position where they are unlikely to be exposed to any
substance which may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to
being corroded or are suitably protected against being so corroded. 7. Checks
to electrical devices: Repair and maintenance to electrical components shall
include initial safety checks and component inspection procedures. If a fault
exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the owner
of the equipment so all parties are advised. Initial safety checks shall
include: · That capacitors are discharged: this shall be done in a safe manner
to avoid possibility of sparking. · That no live electrical components and
wiring are exposed while charging, recovering or purging the system. · Keep
continuity of earthing.
Inspection of Cable
Check the cable for wear, corrosion, overvoltage, vibration and check if there
are sharp edges and other adverse effects in the surrounding environment.
During the inspection, the impact of aging or the continuous vibration of the
compressor and the fan on it should be taken into consideration.
Leakage check of R32 refrigerant
Note: Check the leakage of the refrigerant in an environment where there is no
potential ignition source. No halogen probe (or any other detector that uses
an open flame) should be used. Leak detection method: For systems with
refrigerant R32, electronic leak detection instrument is available to detect
and leak detection should not be conducted in environment with refrigerant.
Make sure the leak detector will not become a potential source of ignition,
and is applicable to the measured refrigerant. Leak detector shall be set for
the minimum ignitable fuel concentration (percentage) of the refrigerant.
Calibrate and adjust to proper gas concentration (no more than 25%) with the
used refrigerant. The fluid used in leak detection is applicable to most
refrigerants. But do not use chloride solvents to prevent the reaction between
chlorine and refrigerants and the corrosion of copper pipeline. If you suspect
a leak, then remove all the fire from the scene or put out the fire. If the
location of the leak needs to be welded, then all refrigerants need to be
recovered, or, isolate all refrigerants away from the leak site (using cut-off
valve). Before and during the welding, use OFN to purify the entire system.
21
ENG
Removal and Vacuum Pumping
1. Make sure there is no ignited fire source near the outlet of the vacuum
pump and the ventilation is well. 2. Allow the maintenance and other
operations of the refrigeration circuit should be carried out according to the
general procedure, but the following best operations that the flammability is
already taken into consideration are the key. You should follow the following
procedures: · Remove the refrigerant. · Decontaminate the pipeline by inert
gases. · Evacuation. · Decontaminate the pipeline by inert gases again. · Cut
or weld the pipeline. 3. The refrigerant should be returned to the appropriate
storage tank. The system should be blown with oxygen free nitrogen to ensure
safety. This process may need to be repeated for several times. This operation
shall not be carried out using compressed air or oxygen. 4. Through blowing
process, the system is charged into the anaerobic nitrogen to reach the
working pressure under the vacuum state, then the oxygen free nitrogen is
emitted to the atmosphere, and in the end, vacuumize the system. Repeat this
process until all refrigerants in the system is cleared. After the final
charging of the anaerobic nitrogen, discharge the gas into the atmosphere
pressure, and then the system can be welded. This operation is necessary for
welding the pipeline.
Procedures of Charging Refrigerants
As a supplement to the general procedure, the following requirements need to
be added: – Make sure that there is no contamination among different
refrigerants when using a refrigerant charging device.
The pipeline for charging refrigerants should be as short as possible to
reduce the residual of refrigerants in it. – Storage tanks should remain
vertically up. – Make sure the grounding solutions are already taken before
the refrigeration system is charged with refrigerants. – After finishing the
charging (or when it is not yet finished), label the mark on the system. – Be
careful not to overcharge refrigerants.
Scrap and Recovery
Scrap: Before this procedure, the technical personnel shall be thoroughly
familiar with the equipment and all its features, and make a recommended
practice for refrigerant safe recovery. For recycling the refrigerant, shall
analyze the refrigerant and oil samples before operation. Ensure the required
power before the test. 1.Be familiar with the equipment and operation.
2.Disconnect power supply. 3.Before carrying out this process, you have to
make sure: · If necessary, mechanical equipment operation should facilitate
the operation of the refrigerant tank. · All personal protective equipment is
effective and can be used correctly. · The whole recovery process should be
carried out under the guidance of qualified personnel. ·The recovering of
equipment and storage tank should comply with the relevant national standards.
4. lf possible, the refrigerating system should be vacuumized. 5. If the
vacuum state can’t be reached, you should extract the refrigerant in each part
of the system from many
places. 6. Before the start of the recovery, you should ensure that the
capacity of the storage tank is sufficient. 7. Start and operate the recovery
equipment according to the manufacturer’s instructions. 8. Don’t fill the tank
to its full capacity (the liquid injection volume does not exceed 80% of the
tank volume). 9. Even the duration is short, it must not exceed the maximum
working pressure of the tank. 10. After the completion of the tank filling and
the end of the operation process, you should make sure that the
tanks and equipment should be removed quickly and all closing valves in the
equipment are closed. 11. The recovered refrigerants are not allowed to be
injected into another system before being purified and tested. Note: The
identification should be made after the appliance is scrapped and refrigerants
are evacuated. The identification should contain the date and endorsement.
Make sure the identification on the appliance can reflect the flammable
refrigerants contained in this appliance.
22
ENG Recovery: 1. The clearance of refrigerants in the system is required when
repairing or scrapping the appliance. It is
recommended to completely remove the refrigerant. 2. Only a special
refrigerant tank can be used when loading the refrigerant into the storage
tank. Make sure the
capacity of the tank is appropriate to the refrigerant injection quantity in
the entire system. All tanks intended to be used for the recovery of
refrigerants should have a refrigerant identification (i.e. refrigerant
recovery tank). Storage tanks should be equipped with pressure relief valves
and globe valves and they should be in a good condition. If possible, empty
tanks should be evacuated and maintained at room temperature before use. 3.
The recovery equipment should be kept in a good working condition and equipped
with equipment operating instructions for easy access. The equipment should be
suitable for the recovery of R32 refrigerants. Besides, there should be a
qualified weighting apparatus which can be normally used. The hose should be
linked with detachable connection joint of zero leakage rate and be kept in a
good condition. Before using the recovery equipment, check if it is in a good
condition and if it gets perfect maintenance. Check if II electrical
components are sealed to prevent the leakage of the refrigerant and the fire
caused by it. If you have any question, please consult the manufacturer. 4.
The recovered refrigerant shall be loaded in the appropriate storage tanks,
attached with a transporting instruction, and returned to the refrigerant
manufacturer. Don’t mix refrigerant in recovery equipment, especially a
storage tank. 5. The space loading R32 refrigeration can’t be enclosed in the
process of transportation. Take anti electrostatic measures if necessary in
transportation. In the process of transport, loading and unloading, necessary
protective measures must be taken to protect the air conditioner to ensure
that the air conditioner is not damaged. 6. When removing the compressor or
clearing the compressor oil, make sure the compressor is pumped to an
appropriate level to ensure that there is no residual R32 refrigerants in the
lubricating oil. The vacuum pumping should be carried out before the
compressor is returned to the supplier. Ensure the safety when discharging oil
from the system.
23
ENG
REMOTE CONTROLLER INSTRUCTIONS
· Carefully read the instructions for safe and correct use of the air-
conditioner. · Carefully keep the instructions as it can be referred to at any
time.
Buttons description
· Type: A shown as
· Type: B shown as
· Type: A shown as
· Type: B shown as
NOTE
1. There are two different display types of remote control ( type A and type
B} , whichever is the actual type.
2. The remote controller display all symbols during power-on, other time only
display symbols corresponding to current operation.
1. ON/OFF button Press this button to turn on/off the unit. This will clear the existing timer and sleep settings.
2. MODE Button
Press this button, you can select operation mode as follows:
AUTO
COOL
DRY
HEAT
FAN
NOTE
Heat mode is not available for cool only units. Please read the Usage for Mode for a detailed description.
3. TIMER Button · With the unit on, press this button to set off timer or
with it off to set on timer.
· Press this button once, the “ON(OFF)” will flash. Press ” + “or ” – ” to set
the number of hours in which the unit will be turned on/off, with an interval
of 0.5 hour, and a range of 0.5-24 hours.
· Press it again to confirm the setting, the “ON (OFF)” will stop flashing.
· If the “TIMER” button is not pressed within 10 seconds after the “ON (OFF)”
start flashing, the timer setting will be exited.
· If a timer setting is confirmed, press this button again will cancel it.
24
ENG
4. HEAT Button Press this button to enter “HEAT” mode.
5. COOL Button Press this button to enter “COOL” mode.
6. SPEED Button Press this button, you can select fan speed as follows:
Low
Mid
High
Turbo
Auto
NOTE
Auto air speed is not available in fan mode. Turbo air speed is not available in auto mode. This button is invalid in dry mode.
7. + & – Button · Each time the ” + ” is pressed, the temperature setting
will increase by 1°C (1°F) and each time the” – “is pressed,
it will decrease by 1°C (1°F).
· The temperature setting range: 16°C (60°F) ~ 32°C(90°F).
NOTE The temperature cannot be set in auto or fan mode.
8. MENU & OK Button · Press the “MENU” button to enter the function selection
mode.
Then press , , and to choose the function which you want. After, press the
“OK” button, turn on this function. · In function selection mode, press , ,
and , the character in LCD will be flashing if the function can be selected.
9. L/R SWING Button Press this button to activate left/right swing and press
it again to turn off the swing function.
10. U/D SWING Button Press this button to activate up/down swing and press it
again to turn off the swing function.
NOTE
· When the unit is on, press the “U/D SWING” button and hold for 3 seconds,
the button will shift to be the functional button of “Rated swinging”, and
then press the “U/D SWING” button to select the positions of Rated swinging.
· Only by pressing the “U/D SWING” button again and hold for 3 seconds or
reinstall the battery of the remote control, can the “U/D SWING” button resume
its original function. The power on/off button of the remote control can not
enable the exit of the “Rated swinging” function.
11. HEALTH When the unit is on, press the “MENU” button ,then press , , and
to choose “HEALTH” character, when the “HEALTH” character will blink, and
press the “OK” button to highlight (not highlight) the “HEALTH” character,
which will activate (deactivate) the health function.
12. ECO · In the cooling mode, the variable frequency air-conditioner will
enter the ECO mode, which consumes the least
electricity, and exit it automatically 8 hours after. · The ECO mode is not
available on the fixed frequency air conditioner. · Changing modes or turning
off the remote controller will automatically cancel the ECO function.
25
ENG
· In the cooling mode, press the “MENU” button, then press , , and to choose the “ECO”character, when the “ECO” character will blink, and press the “OK” button to highlight (not highlight) the “ECO” character , which will activate (deactivate) the ECO function.
NOTE
The electricity consumption is affected by the ambient temperature and the house structure etc., and when the ambient temperature is high or the house has a large area, be cautious to use the ECO mode.
13. SLEEP
· When the unit is on, press the “MENU” button, then press , , and to choose
the “SLEEP” character, when the “SLEEP” character will blink, and press the
“OK” button to highlight (not highlight ) the “SLEEP” character , which will
activate (deactivate) the function of sleep mode.
· The unit will exit SLEEP mode after 10 hours of continuous operation and
restore to the previous status.
NOTE
The sleep function cannot be activated in fan or auto mode. In the sleep mode, the screen of the air-conditioner is off.
14. SILENCE When the unit is on, press the “MENU” button, then press , , and
to choose the “SILENCE” character, when the “SILENCE” character will blink,
and press the “OK” button to highlight (not highlight ) the “SILENCE”
character , which will activate (deactivate) the function of silent wind.
15. ELE.H · When the unit is on, press the “MENU” button, then press , , and
to choose the “ELE.H” character,
when the “ELE.H” character will blink, and press the “OK” button to highlight
(not highlight ) the “ELE.H” character , which will activate (deactivate) the
function of auxiliary heating. · The unit will activate the auxiliary heating
function automatically according to the ambient temperature, so as to
accelerate the heating. · This button is disabled on some models.
16. DISPLAY Press the “MENU” button, then press , , and to choose the “DISPLAY” character, when the character “DISPLAY” will blink, and press the “OK” button to activate (deactivate) the function of screen display.
17. LIGHT · The unit will activate or deactivate automatically the function
of display on the air-conditioner screen according
to the indoor ambient brightness.
· When the unit is on, press the “MENU” button, then press , , and to choose
the “LIGHT” character, when the “LIGHT” character will blink, and press the
“OK” button to highlight (not highlight) the character “LIGHT”, which will
activate (deactivate) the function of light sensing.
18. COSY (Only Type A)
· When the air-conditioner is on under the modes of cooling, press the “MENU”
button, then press , , and
to choose the “COSY” character , when the “COSY” character will blink, and
press the “OK”button to highlight (not highlight) the character “COSY”, which
will activate (deactivate) the function of cleaning.
· When the “COSY” function is on, the fan speed is auto and it will cancel the
swinging funcution. When the “COSY” function is on, these operations that turn
off the unit, change the mode, and set SLEEP, fan speed, swinging function
will automatically exit the”COSY” function, then restore to the previous
status.
19. HUMI (Only Type A) Press the “MENU” button, then press , , and to choose
the “HUMI” character, when the “HUMI” character will blink, and press the “OK”
button to highlight (not highlight) the “HUMI” character , which will
activate(deactivate) the humidifying function.
NOTE The humidifying function is not available under the dry mode.
26
ENG
20. iCLEAN · The unit will clean automatically the dusts on the evaporator
and dry or blow-dry the moisture. · When the air-conditioner is off, press the
“MENU” button, then press , , and to choose the “iCLEAN”
character , when the “iCLEAN” character will blink, and press the “OK” button
to highlight ( not highlight) the character “iCLEAN”, which will activate
(deactivate) the function of cleaning. · The cleaning function will close
automatically after 30 minutes.
21. Child-lock · Press the “HEAT” and “MODE” buttons at the same time and
hold for at least 3 seconds to activate or deactivate
the child-lock function.
· When the child-lock function is activated, the remote control will indicate
” “.
22. Anti-F (Only Type B) · Anti-F function: When the unit is closed under the
modes of cooling, dry or auto (cooling), it will continue to
operate for about 3 minutes to dry the moisture on the evaporator, so as to
prevent the accumulation of bacteria on the evaporator, which causes fungus
and strange smell and is harmful to the health.
· When the unit is off, press the “MENU” button, then press , , and to choose
the “Anti-F” character , when the “Anti-F” character will blink, and press the
“OK” button to highlight (not highlight) the “Anti-F” character , which will
activate (deactivate) the Anti-F function.
23. I-FEEL (Only Type B) When the unit is on, press the “MENU” button, then press , , and to choose the “I-FEEL” character, when the “I-FEEL” character will blink, and press the “OK” button to highlight (not highlight ) the “I-FEEL” and ” ” character , which will activate (deactivate) the I-FEEL function .
24. °C/°F · The temperature is displayed by default in Celsius.
· Press the “COOL” and “HEAT” buttons at the same time above 3 seconds, you
can set the “°C ” or “°F “.
NOTE
Temperature display in Fahrenheit is not available for some models. When temperature is displayed in Fahrenheit on the remote controller, it might be in Celsius on the unit, the function and operation of which will not be affected.
25. 8° C heating function · 8°C heating function is only available for some
models · Only in the heating mode in the power-on state, press the “MODE” and
“+” buttons at the same time above 3
seconds to turn on or off the 8°C heating function. · After turning on the 8°C
heating function:
a. Press the “HEAT” button, or switch to mode, or select the sleep function,
all can exit 8°C heating function. b. Press the “SPEED”,”+”,”-” button is all
non-effective. c. Fahrenheit/Celsius switching function is non-effective. d.
Turn off and on the unit again, 8°C heating function is still retained. e.
Press the “MENU” button, ELE.H function is not selectable.
Auto operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press
the “MODE” button, select auto operation mode. 3. By pressing the “SPEED”
button, you can select fan speed from Low, Mid, High, Auto. 4. Press the
“ON/OFF” button again, the air-conditioner stops.
NOTE In the auto mode, the temperature settings is non-effective.
27
ENG
Cool/Heat operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press
the “MODE” button, select cool or heat operation mode. 3. By pressing the ” +
“or” – “button, you can set temperature from 16°C (60°F) to 32°C(90°F), the
display changes
as you press the button. 4. By pressing the “SPEED” button, you can select fan
speed from Low, Mid, High, Turbo, Auto. 5. Press the “ON/OFF” button again,
the air-conditioner stops.
NOTE The cold wind type has no heating function.
Fan operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press
the “MODE” button, select fan operation mode. 3. By pressing the “SPEED”
button, you can select fan speed from Low, Mid, High. 4. Press the “ON/OFF”
button again, the air-conditioner stops.
NOTE In the fan mode, the temperature settings is non-effective.
Dry operation mode
1. Press the “ON/OFF” button, the air-conditioner starts to operate. 2. Press
the “MODE” button, select dry operation mode. 3. By pressing the ” + “or” –
“button, you can set temperature from 16°C (60°F) to 32°C(90°F), the display
changes
as you press the button. 4. Press the “ON/OFF” button again, the air-
conditioner stops.
NOTE In the dry mode, the speed settings is non-effective.
Usage
Fix batteries
1. Slide to open the battery cover according to the direction indicated by
the arrowhead. 2. lnsert two brand new batteries (7#), and position the
batteries to the right electric poles(+&-). 3. Put back the battery cover.
Smart WiFi app user manual can be found at: https://tesla.info/wp-
content/uploads/pdf/TeslaTAWiFiapp.pdf
28
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>