DIMLUX 21-039 Air Pump Controller Fan
Product Information
Specifications:
- Brand: DIMLUX
- Product: Fan/Pump Controller
- Model: V-1022-2021
- Made in: Holland
- Website: dimlux.nl
Product Usage Instructions
-
General Settings
In the controller, you can change 4 main settings: Home, Fan, Pump, and Valve. Press ESCAPE to navigate to each setting. -
Home Setting
This setting displays the current time and allows you to adjust the temperature offset. -
Fan Setting
This setting controls the fan operation. You can adjust parameters such as mode fan, temperature setpoint, fan speed, and more. -
Pump Setting
Here you can monitor the pump current and make adjustments if needed. -
Valve Setting
This setting is not used unless setup is located in very cold outdoor areas. Contact Support for assistance in such cases.
Frequently Asked Questions (FAQ):
How do I change the fan speed?
Navigate to the Fan setting using the ESCAPE button. Use the + or - key to scroll through the menu and locate the options for High Speed Fan and Low Speed Fan to adjust the fan speed accordingly.
Can I change the temperature setpoint for the fan?
Yes, in the Fan setting, you can find the Temperature Setpoint option to change the target water temperature for the fan operation.
What is the default temperature offset in the Home setting?
The default temperature offset is 1.5°C. You can press SET to change this value as needed.
GENERAL
In the controller you change 4 main settings.
- HOME
- FAN
- PUMP
- VALVE
You can find each of the 4 settings by pressing ESCAPE
MENU HOME
ESCAPE → HOME → Press SET to enter Menu
Use the + or – key to scroll the menu and to change a value. Use set to enter
a value.
- Time: The present time. press set to change
- Temp offset: (default 1.5*C) press set to change
MENU FAN
ESCAPE → FAN → Press SET to enter Menu
Use the + or – key to scroll the menu and to change a value. Use set to enter
a value.
- Mode fan: (default: temperature) change to Fan off, fan on or Temperature
- Temperature Setpoint: (default 27*C) Change the target water temperature
- BB fan: (Default 7) To set range before fullspeed
- Temp: Cutoff point: (default 25*C) Fan start and stop at minimum speed
- Fall/Rise delay: (default off) Delay before fan ramps up/down
- High Speed Fan: (default 100%) Set maximum fan speed
- Lo Speed Fan: (default 20%) Set minimum fan speed (set to 35% when using smartbox)
- Power Safe Fan: (default on) The fan can run when pump is off, on or off
- Temp Hysterese Fan: (default 1*C) Set temp hysterese for the fan
MENU PUMP
ESCAPE → PUMP → Press SET to enter Menu
Use the + or – key to scroll the menu and to change a value. Use set to enter
a value.
- Mode pump: (default Current) Change to pump off, pump on and pump current
- Current Treshold: (default 500mA) Pump start when compressor current is > setpoint
- Auto Interval: (default 10min/60sec) pump on with compressor off duration and interval
- Trailing Time: (default 10min) Time that pump stays on after compressor off
- Trailing countdown: (not a setting) shows actual duration of trailing time in seconds
- Sensor Model: (Default depends on supplied sensor) should match tekst on pump sensor
- Pressure Switch: Not supported
MENU VALVE
ESCAPE → Press → SET to enter Menu
Use the + or – key to scroll the menu and to change a value. Use set to enter
a value.
Not used. Contact Support when setup is located in very cold outdoor areas.