Aquafire AWPR2-20-50 AFireWater Prestige Water Vapor Electric Fireplace Installation Guide
- June 1, 2024
- Aquafire
Table of Contents
- Aquafire AWPR2-20-50 AFireWater Prestige Water Vapor Electric Fireplace
- Product Information
- Product Usage Instructions
- FEATURE
- Quick Start Guide
- Preliminary Planning Information
- Fireplace Specs and Cutout Dimensions
- Installing Aquafire Insert
- Enclosure Design Guidelines
- Maintenance and Cleaning Guidelines
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aquafire AWPR2-20-50 AFireWater Prestige Water Vapor Electric Fireplace
Product Information
Specifications
- Model: Aquafire Pro Series AWPR2-20 / AWPR2-40 / AWPR2-60
- Power: 60W / 120W / 180W (Standard wall receptacle)
- Tank Capacity: 2.0 Liters / 4.0 Liters / 6.5 Liters
- Run Time: 20 Hours
- Direct Plumbed: 1/4” water line
- Weight: 29 lbs / 58 lbs / 89 lbs (Crated Weight: 53 lbs / 90 lbs / 123 lbs)
Product Usage Instructions
Installing Into Its Site-Built Enclosure
- Remove the top plate.
- Connect the 24V power adapter located on the back of the unit.
- Install Aquafire into its housing as shown in the example.
- Reinstall the top plate and complete the installation.
Filling Aquafire with Automatic Pump
- When the water tank is empty, lights will blink and small beeps will be heard.
- Connect the fill tube to the water connector and press and hold the B1 button for 5 seconds.
- The filling process will start and end automatically when the tank is full.
Connecting to Water Supply
- Connect a suitable reducer to the water network (Reducer = water network tube dimensions to 1/4).
- Connect the 1/4 PEX pipe to Aquafire through either the bottom opening or side opening.
Pairing the Remote Control
- Press and hold the Power button on the unit for 5 seconds until it starts flashing.
- Press any button on the remote; a beep confirms successful pairing.
Frequently Asked Questions (FAQ)
What are the different sizes available in the Aquafire Pro Series?
The Aquafire Pro Series offers three sizes: AWPR2 20-50 (20''), AWPR2-40-100 (40''), and AWPR2-60-150 (60'').
How long is the run time of Aquafire Pro models?
The run time for all models is 20 hours.
How do I know when to fill the water tank?
When the water tank is empty, lights will blink, and you will hear small beeps indicating it's time to refill.
FEATURE
3 Sizes, AWPR2-20-50 20’’ / AWPR2-40-100 40’’ / AWPR2-60-150
- Units can be ganged together to create continuous ribbons of flames up to 20 feet (240’’) .
- Can be direct plumbed for automated filling (unlimited run time), or manually (20 hours of run time).
- Integrated pumping system can remove water from the tank(s) or be used to fill manually without overflowing.
- Adjust flame color, size and speed (intensity) (8’’ to 10’’ flames).
- Set flames to natural color or select from 30 other preset colors.
- Control via button on device, smart phone app, or integrate with in-room automation via the dry port contact.
- Easy Flush Mount Install.
- Air Intake through the lid.
- Alternate Hidden Air Intake (from below).
- Internal UV-C Lighting sanitizes water & vapor.
Quick Start Guide
Installing Into Its Site-Built Enclosure
- Remove the top plate.
- Connect the 24V power adapter (located on the back side of the unit).
- Install Aquafire into its housing, as shown in example below.
- Reinstall the top plate of the fireplace and install is complete.
Filling Aquafire with Automatic Pump
- When the water tank is empty, you will see the lights blinking and you will hear small beeps.
- Connect the fill tube to the water connector and press and hold the “B1” button for 5 seconds.
- The filling will start automatically and will end automatically when the water tank is full.
Connecting to Water Supply
- Connect a suitable reducer to the water network.(Reducer = water network tube dimensions to 1/4″)
- Connect the 1/4″ PEX pipe to Aquafire. Two possible connections: Bottom opening or side opening.
Pairing the Remote Control
- Press and hold the Power button on the unit for 5 seconds or until the button will begins flashing.
- Press any button on the remote, you will hear a beep.
- Beep confirms the control is paired to the unit.
Preliminary Planning Information
Aquafire Pro water vapor fireplace inserts have been designed to be
extremely easy to install, simple to operate, and easy to maintain. When
designing your fireplace, feel free to send your plans in for review and
suggestions by our professional design staff.
Considerations:
- Accessibility to electricity and 1/4’’ water line, similar to ice maker in fridge.
- Recessed into wall, sitting proud of a wall or completely free-standing?
- If light cast upwards to ceiling is undesirable, consider recessing into the wall for a traditional hearth appearance. (we advise to create a ‘light trap’. see Light Trap page for details)
- Determine decorative materials and finishes you expect to use. Since there is no heat, there are virtually no limitations.
- Plan to make it easy to remove fireplace insert should maintenance or repairs become necessary.
- Avoid or prevent air currents from doors, windows, and existing HVAC system which affect flame quality.
Installation:
Prepare the housing for your fireplace insert(s) and make sure the cutout has
sharp corners (not rounded) and dimensions are exactly as specified. These
dimensions are critical because the modules are suspended on flanges that span
the opening. Too small, and fireplace will not fit, too large of opening, and
fireplace insert will look sloppy or may even fall through the opening. Using
the built in ‘lifting loops’, suspend the Aquafire Pro into the cutout after
plugging in electric power converter(s) and connecting the 1/4’’ waterline if
direct plumbed. If not direct plumbed, fill tank using tap water via the
integrated pumping system once installed into cutout.
That’s it!– the installation is complete. Now start your fireplace and enjoy an
extraordinary fireplace experience every day of the year!
Fireplace Specs and Cutout Dimensions
Aquafire Dimensions
Cutout Dimensions
Up to 20 Feet of Flame
Connect and combine fireplace inserts together to create up to 20 feet of
continuous flame that can be controlled by a single remote.
Installing Aquafire Insert
Installing Insert into custom enclosure
Drop-in install
Aquafire inserts are designed to drop in to an enclosure and hang from the
lid’s flanges, allowing for easy install and adequate airflow underneath the
unit.
Cutout Dimensions
Note: Cutout dimensions are critical! Fireplace inserts are suspended in cutout opening from the attached flanges so be sure to measure carefully!
Enclosure Design Guidelines
Design Review!
When you have your design schematic or working drawings, it’s a good idea to
get a review by an Aquafire professional. We are here to help!
sales@aquafire.com
Recommended Enclosure Dimensions
PLAN VIEW
SINGLE SIDED & DOUBLE-SIDED HEARTH (walls optional)
Enclosure Ideas
Some examples of the many ways to install Aquafire.
Light Bleed Examples
Air Flow Best Practices
Air vents
Air vents are situated atop the insert to enable airflow when the device is
placed within an enclosure. Should there be a preference for a decorative top
or media obstructing these vents, the enclosure design needs to facilitate
adequate airflow through the sides or bottom.
Maintenance and Cleaning Guidelines
Hard Water Guidelines
For best results, descale your fireplace every three months or more frequently
if you live in an area with hard water.
3.5 to 8.5 Grains Per Gallon, Ideal is 7.0 (moderately hard)
- Hard may produce scaling, shorten transducer life, and require more frequent cleaning.
- If water hardness needs to be adjusted, consult local water conditioning professional.
- Water that is too soft will have reduced flame effect.
Reverse Osmosis is not recommended, it removes all minerals and vapor flame effect will be greatly diminished.
For more instruction visit: https://electricfireplacesdepot.com/pages /aquafire-preventative-maintenance-guidelines
Contact Us
sales@electricfireplacesdepot.com
www.electricfireplacesdepot.com
(800)-309-2144
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>