Building 36 Temperature Sensor B36-S10 Manual
- June 8, 2024
- Building 36
Table of Contents
- Building 36
- Building 36 Temperature Sensor
- SKU: B36-S10
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Wake Up Period
- Parameter 2: Low Battery Level
- Parameter 3: Temperature Reporting Threshold
- Parameter 4: Configuration Bitmask
- Parameter 5: Battery Reporting Interval
- Parameter 6: Temperature Checking Interval
- Parameter 7: Temperature Reporting Interval
- Parameter 8: Temperature Calibration Offset
- Parameter 9: Mandatory Temperature Reporting Interval
- Technical Data
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Building 36
Building 36 Temperature Sensor
SKU: B36-S10
Quickstart
This is a ****
Multilevel Sensor
for
U.S. / Canada / Mexico.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Put the Z-Wave controller into add mode (refer to controller documentation for
more information).Press the button on the sensor to add to the Z-Wave network.
The LED on the sensor will go solid white when the sensor has been
successfully added.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Battery powered indoor Z-Wave temperature sensor.Sense temperature in any room in the home.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
NOTE: Only reset the sensor to factory default when the primary controller is missing or inoperable.Press and hold the button for 15 seconds.Release the button after 15 seconds and the LED will blink rapidly when the sensor has been reset to factory default.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Put the Z-Wave controller into add mode (refer to controller documentation for more information).Press the button on the sensor to add to the Z-Wave network. The LED on the sensor will go solid white when the sensor has been successfully added.
Exclusion
Put the Z-Wave controller into remove mode (refer to the controller documentation for more information).Press the button on the sensor to remove from the Z-Wave network.The LED on the sensor will blink white when the sensor has been successfully removed.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
The temperature sensor will send wake up notifications when the button is pressed and the temperature sensor is already included in a Z-Wave network.It also sends wake up notifications based at time intervals specified in the wake up set command.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Z-Wave Plus Lifeline. |
---|---|---|
2 | 5 | Sensor Multilevel Temperature Report. |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Wake Up Period
Number of seconds the sensor will stay in the Wake up state following a
button press. The sensor will go to sleep if it receives a wake up no more
information frame.
Size: 2 Byte, Default Value: 600
SettingDescription
10 – 32768 | Seconds to stay awake following button press |
---|
Parameter 2: Low Battery Level
Low Battery Report threshold.
Size: 2 Byte, Default Value: 1755
SettingDescription
1000 – 2500 | Battery level |
---|
Parameter 3: Temperature Reporting Threshold
The minimum temperature difference required to send a new ambient
temperature report.
Size: 2 Byte, Default Value: 10
SettingDescription
0 – 100 | Tenths of a degree Fahrenheit.A value of 10 would be 1.0F. |
---|
Parameter 4: Configuration Bitmask
Configuration bitmask for various device configuration settings. Bit 0 –
reserved.Bit 1 – If set to 1, sensor will send unsolicited temperature
reports.Bits 2 to 15 – reserved
Size: 2 Byte, Default Value: 2
SettingDescription
0 | If zero, sensor will not send unsolicted temperature reports |
---|---|
2 | If Bit 1 is set, sensor will send unsolicited temperature reports when the |
temperature changes.
Parameter 5: Battery Reporting Interval
The number wakeup intervals between autonomous battery reports.
Size: 2 Byte, Default Value: 8
SettingDescription
0 – 255| Number of wake up intervals between autonomous battery reports.The
wake up interval is set in the Wake Up Command Class.
---|---
Parameter 6: Temperature Checking Interval
The number of seconds between temperature readings.
Size: 2 Byte, Default Value: 60
SettingDescription
10 – 255 | The number of seconds between temperature readings |
---|
Parameter 7: Temperature Reporting Interval
The number wakeup intervals between autonomous temperature reports. These
interval reports should be sent regardless of the setting of the temperature
reporting threshold.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 255| The number of wake up intervals between autonomous temperature
reports.If this value is zero, autonomous temperature reporting based on wake
up interval is disabled.
---|---
Parameter 8: Temperature Calibration Offset
Adjust reported temperature by +/- 10 degrees Fahrenheit for calibration.
Size: 2 Byte, Default Value: 0
SettingDescription
-100 – 100 | Tenths of a degree Fahrenheit.A value of 10 would be 1.0F. |
---|
Parameter 9: Mandatory Temperature Reporting Interval
Temperature will be reported regardless of differential from threshold.
Size: 2 Byte, Default Value: 7200
SettingDescription
60 – 64800 | The number of seconds between temperature reports. |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Multilevel Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16010010 |
Z-Wave Product Id | 0x0190.0x0003.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.