Aquafire AWA2-20-50 Water Vapor 20 Built In Electric Fireplace Insert Installation Guide
- May 15, 2024
- Aquafire
Table of Contents
- AWA2-20-50 Water Vapor 20 Built In Electric Fireplace Insert
- Quick Start Guide
- Preliminary Planning Information
- Fireplace Specs and Cutout Dimensions
- Enclosure Design Guidelines
- Installing Aquafire Insert
- Maintenance and Cleaning Guidelines
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation Guidelines
and Best Practices
Aquafire Series
AWA2-20-50 / AWA2-40-100
/ AWA2-60-150
AWA2-20-50 Water Vapor 20 Built In Electric Fireplace Insert
Experience the original water vapor flames and dazzling orange glow of Aquafire with our pioneering series of inserts.
Aquafire Series
3 Sizes, AWA2-20-50 20’’ / AWA2-40-100 40” / AWA2-60-150 60’’ .
- Units can be ganged together to create continuous ribbons of flames up to 20 feet (240’’) .
- 20 hours of run time or can be direct plumbed for unlimited run time (direct plumb kit sold separately).
- Adjust the flame size (height) and speed (intensity) to enjoy 8 to 12” inch flames.
- Control via button on device or integrate with in-room automation via the dry port contact.
- Easy Flush Mount Install.
- Air Intake through the lid.
- Alternate Hidden Air Intake (from below).
- Internal UV-C Lighting sanitizes water & vapor.
Quick Start Guide
-
Installing Into Its Site-Built Enclosure
1. Remove the top plate.
2. Connect the 24V power adapter (located on the back side of the unit).
3. Install Aquafire into its housing, as shown in example below.
4. Reinstall the top plate of the fireplace and install is complete. -
Filling Aquafire with Automatic Pump
1 When the water tank is empty, you will see the lights blinking and you will hear small beeps.
2 Connect the fill tube to the water connector and press and hold the “B1” button for 5 seconds.
3 The filling will start automatically and will end automatically when the water tank is full. -
Connect Direct Plumb Kit (Optional)
Connect a suitable reducer to the water network.
1. (Reducer = water network tube dimensions to 1/4″)
2.Connect the 1/4″ PEX pipe to the Aquafire
Direct Plumb Kit (sold separately).
3. The filling will start automatically and will end automatically when the water tank is full. 4. Pairing the Remote Control
Press and hold the Power button on the unit for
1.5 seconds or until the button will begins flashing.
2.Press any button on the remote, you will hear a beep.
3.Beep confirms the control is paired to the unit.
Preliminary Planning Information
Aquafire Pro water vapor fireplace inserts have been designed to be
extremely easy to install, simple to operate, and easy to maintain. When
designing your fireplace, feel free to send your plans in for review and
suggestions by our professional design staff.
Considerations:
- Accessibility to electricity and 1/4’’ water line, similar to ice maker in fridge.
- Recessed into wall, sitting proud of a wall or completely free-standing?
- If light cast upwards to ceiling is undesirable, consider recessing into the wall for a traditional hearth appearance. (we advise to create a ‘light trap’. see Light Trap page for details)
- Determine decorative materials and finishes you expect to use. Since there is no heat, there are virtually no limitations.
- Plan to make it easy to remove fireplace insert should maintenance or repairs become necessary.
- Avoid or prevent air currents from doors, windows, and existing HVAC system which affect flame quality.
Installation:
Prepare the housing for your fireplace insert(s) and make sure the cutout has
sharp corners (not rounded) and dimensions are exactly as specified. These
dimensions are critical because the modules are suspended on flanges that span
the opening. Too small, and fireplace will not fit, too large of opening, and
fireplace insert will look sloppy or may even fall through the opening. Using
the built in ‘lifting loops’, suspend the Aquafire into the cutout after
plugging in electric power converter(s) and connecting the 1/4’’ waterline if
direct plumb kit is installed. If not, simply fill tank using tap water via the
integrated pumping system once installed into enclosure.
That’s it!– the installation is complete. Now start your fireplace and enjoy an
extraordinary fireplace experience every day of the year!
World’s most advanced water vapor fireplace technology!
Fireplace Specs and Cutout Dimensions
Aquafire Dimensions
| |
---|---|---
20’’ AWA2-20-50:
Power: 60 W (Standard wall receptacle)
Tank Capacity: 2.0 Liters / Run Time 20 Hours
Direct Plumbed: 1/4’’ water line
Weight: 29 lbs / Crated Weight 53 lbs| 40’’ AWA2-40-100:
Power: 120 W (Standard wall receptacle)
Tank Capacity: 4.0 Liters / Run Time 20 Hours
Direct Plumbed: 1/4’’ water line
Weight: 58 lbs / Crated Weight 90 lbs| 60’’ AWA2-60-150:
Power: 180 W (Standard wall receptacle)
Tank Capacity:6.5 Liters / Run Time 20 Hours
Direct Plumbed:1/4’’ water line
Weight: 89 lbs / Crated Weight 123 lbs
Cutout Dimensions
SIZE | W | D | H | |
---|---|---|---|---|
20’’ | AWA2-20-50: | 20 ¼’’ x | 12 ¼” x | 12” |
40’’ | AWA2-40-100: | 40 ¼’’ x | 12 ¼” x | 12” |
60’’ | AWA2-60-150: | 60 ¼’’ x | 12 ¼” x | 12” |
Note:
Cutout dimensions are critical! Fireplace inserts are suspended in cutout
opening from the attached Langes so be sure to measure carefully!
Up to 20 Feet of Flame
Connect and combine fireplace inserts together to create up to 20 feet of
continuous flame that can be controlled by a single remote.
Enclosure Design Guidelines
Recommended Enclosure Dimensions
Design Review!
When you have your design schematic or working drawings, it’s a good idea to
get a review by an Aquafire professional. We are here to help!
sales@aquafire.com
Pro Tip: Avoid using reflective materials (tile, stone, HPL, etc) on the top inside of the light trap. A darker, non-reflective finish in the firebox will accentuate the flame effect and limit light bleed.
PLAN VIEW
SINGLE SIDED & DOUBLE-SIDED HEARTH (walls optional)
Pro Tip:
A minimum of 12” clearance plus a blind corner will help to dramatically cut
down on horizontal light reflection.
For optimal results, utilize an open-ended hearth design.
Installing Aquafire Insert
Installing Insert into custom enclosure
Drop-in install
Aquafire inserts are designed to drop in to an enclosure and hang from the
lid’s flanges, allowing for easy install and adequate airflow underneath the
unit.
Cutout Dimensions
SIZE | W | D | H | |
---|---|---|---|---|
20’’ | AWA2-20-50: | 20 ¼’’ x | 12 ¼” x | 12” |
40’’ | AWA2-40-100: | 40 ¼’’ x | 12 ¼” x | 12” |
60’’ | AWA2-60-150: | 60 ¼’’ x | 12 ¼” x | 12” |
*Direct Plumb Kit (optional) requires additional 2” of Height dimension.
Note:
Cutout dimensions are critical! Fireplace inserts are suspended in cutout
opening from the attached flanges so be sure to measure carefully!
Light Bleed Examples
Be aware of side light reflection!
A minimum of 12” clearance plus a blind corner will help to dramatically cut
down on horizontal light reflection. For optimal results, utilize an open-
ended hearth design.
Air Flow Best Practices
SIDE VIEW
SINGLE-SIDED HEARTH
Air currents
Avoid blowing air currents from HVAC units directly toward the Aquafire insert.
Direct air currents can prevent vapor from rising vertically as designed and
limit the flame height.
Air intake requirements
Aquafire inserts require at least 50 square inches of air intake within the
enclosure for every 20 inches of unit length. This is achieved by venting
through either the top lid or, if covered, via a toe kick beneath the
enclosure.
Air vents
Air vents are situated atop the insert to enable airflow when the device is
placed within an enclosure. Should there be a preference for a decorative top
or media obstructing these vents, the enclosure design needs to facilitate
adequate airflow through the sides or bottom.
Maintenance and Cleaning Guidelines
Hard Water Guidelines
For best results, descale your fireplace every three months or more frequently
if you live in an area with hard water.
3.5 to 8.5 Grains Per Gallon, Ideal is 7.0 (moderately hard)
- Hard may produce scaling, shorten transducer life, and require more frequent cleaning.
- If water hardness needs to be adjusted, consult local water conditioning professional.
- Water that is too soft will have reduced flame effect.
Reverse Osmosis is not recommended, it removes all minerals and vapor flame effect will be greatly diminished.
For more instructions visit :https://electricfireplacesdepot.com/pages /aquafire-preventative-maintenance-guidelines
Contact Us
sales@electricfireplacesdepot.com
www.electricfireplacesdepot.com
800-309-2144
www.electricfireplacesdepot.com
Read User Manual Online (PDF format)