PENTAIR WM-25WBQC Wellmate Residential Captive Air Tanks Classic Instruction Manual
- June 3, 2024
- Pentair
Table of Contents
WM-25WBQC Wellmate Residential Captive Air Tanks Classic
Instruction Manual
WM-25WBQC Wellmate Residential Captive Air Tanks Classic
Important – For your safety, please read the entire installation manual before attempting to install this product.
Never install the tank where it can freeze.
A pressure limiting device or pressure relief valve must be installed with
this tank. The warranty is VOID if the system pressure or temperature exceeds
the maximum operating rating on the tank label.
When using a pump with an air injector, the injector port must be plugged in.
The tank is pressurized from the factory. The precharge pressure may vary
somewhat from tank to tank due to temperature and the length of time in
storage. Check and adjust precharge according to the instruction manual when
completing the installation.
WARNING: Failure to install and operate this tank according to the
manufacturer’s recommendations may cause the tank to fail, resulting in fatal
injury, property damage, and/or rendering the tank inoperable. This tank is
pressurized and under no circumstances should the tank, fittings, or connected
system be disassembled prior to the complete discharging of air and fluid
pressures.
WARNING: Before starting the installation, please read all installation
information and supplements.
-
Turn off the electrical power to the pump at the control box.
-
If replacing an existing tank, drain and depressurize the system of water and air pressure and remove the old tank.
-
Remove the tank from the box and attach the threaded connector to the manifold or tank tee (Figure 1).
-
Place the tank in a vertical position on a level surface. The base should be fully supported to ensure maximum stability.
-
Press the tank drain into the plastic connector used in Step 3 (Figure 1).
NOTE: O-ring on the fitting must be lubricated. -
Insert a red H-clip to lock the fitting into the drain assembly (Figure 1).
-
Connect all plumbing lines.
NOTE: Prevent the tank from heating up if you are sweating fittings.
If you are using the brass sweat connector, remove O-ring prior to sweating the connector. -
An adequately sized pressure relief valve must be installed on the inlet line to the tank. The relief valve must not be isolated from the tank by a check valve and must be set so that the maximum operating pressure at the front of the tank is never exceeded.
-
Check and adjust the precharge air pressure of the tank while still empty. The precharge pressure must be set at 4 PSIG (0.28 bar) below the low-pressure limit of the system. Replace the air stem cap, firmly tightening the air stem.
NOTE: For applications with the following conditions: high flow rates, high system pressures, or elevated water and/or air temperatures, it is recommended to increase the precharge differential to 10 PSIG (0.69 bar) below the low-pressure limit of the system.
Typical System Pressure Range | Precharge |
---|---|
30-50 psig (2.07-3.45 bar) | 26 psig (1.79 bar) |
40-60 psig (2.76-4.14 bar) | 36 psig (2.48 bar) |
- Turn on the system and check to assure all connections are leak free.
- Do not exceed the listed operating specifications on the tank operating label.
NOTE: All plumbing should be in compliance with local codes and standards.
FILTRATION & PROCESS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
P: 262.238.4400 | F: 262.238.4404 |
WWW.PENTAIRAQUA.COM | CUSTOMER CARE: 800.279.9404
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates.
All other registered and unregistered trademarks and logos are the property of
their respective owners. Because we are continuously improving our products
and services, Pentair reserves the right to change specifications without
prior notice.
Pentair is an equal-opportunity employer.
CH20522 REV E AP14 © 2014 Pentair Residential Filtration, LLC. All Rights
Reserved.