DIMENSION GUIDE
SLIDE-IN INDUCTION RANGE
**PRODUCT MODEL NUMBER: WSIS5030R***

WSIS5030RZSS Induction Range

APPLIANCE: WSIS5030R•
Unit of Measurement in
A Depth Closed Excluding Handle
B Depth Closed Including Handle
C Depth Excluding Doors
D Depth with Door Open 90°
Es Minimum Height
F Width

*IMPORTANT: Minimum height dimensions are at the lowest point of the height adjustment range. When the leveling legs are fully extended, all heights have 1 1/2″ (3.8 cm) of added height.

Whirlpool WSIS5030RZSS Induction Range - lowest point

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

  • It is the installer’s responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/rating plate is located behind the oven door on the top right-hand side of the oven frame.
  • The range should be located for convenient use in the kitchen.
  • Recessed installations must provide complete enclosure of the sides and rear of the range.
  • To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood or microwave hood combination that projects horizontally a minimum of 5″ (12.7 cm) beyond the bottom of the cabinets.
  • All openings in the wall or floor where range is to be installed must be sealed.
  • Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
  • The anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see “Install Anti-Tip Bracket” section in the Owner’s Manual.
  • Grounded electrical supply is required. See the appropriate “Electrical Requirements” section in the Owner’s Manual.
  • Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C).
  • Use an insulated pad or 1/4″ (6.4 mm) plywood under range if installing range over carpeting.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with  the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home – Additional Installation

Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).  When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA  Z240.1 – latest edition, or with local codes.
Mobile Home Installations Require:

  • When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
  • Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be revised. See “Electrical Connection – U.S.A. Only” section in the Owner’s Manual.

Cabinet Dimensions
Cabinet opening dimensions shown are for 25″ (64.0 cm) countertop depth, 24″ (61.0 cm) base cabinet depth and 36″ (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the cooking surface, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range my be installed next to combustible walls with zero clearance.
NOTE: When installed in a slide-in cutout, the front of oven door may protrude beyond the base cabinet.

Whirlpool WSIS5030RZSS Induction Range - Cutout

A. For minimum clearance to top of cooktop, see NOTE
B. 30″ (76.2 cm) minimum opening width
C. 13″ (33 cm) maximum upper cabinet depth
D. 30″ (76.2 cm) minimum opening width
E. The shaded area is recommended for installation of rigid gas pipe and grounded outlet.
F. 13/ 8 ” (33.3 cm)
G. 7 11/16 ” (19.5 cm)
H. 4 13/ 16 ” (12.2 cm)
I. 3 11/ 16 ” (9.4 cm) plus measurement of K
J. Cabinet door or hinges should not extend into the cutout
K. Remaining counter depth should not exceed 2 1/ 4″ (5.7 cm)| A. For minimum clearance to top of cooktop, see NOTE

B. 30″ (76.2 cm) minimum opening width
C. 13″ (33 cm) maximum upper cabinet depth
D. 30″ (76.2 cm) minimum opening width
E. The shaded area is recommended for installation of rigid gas pipe
and grounded outlet.
F. 13/ 8 ” (33.3 cm)
G. 711 1 / 16 ” (19.5 cm)
H. 4 / 16 ” (12.2 cm)
I. 311 / 16 ” (9.4 cm)
J. Cabinet door or hinges should not extend into the cutout
---|---

NOTE: 24″ (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than 1/4″ (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015″ (0.4 mm) stainless steel, 0.024″ (0.6  mm) aluminum or 0.020″ (0.5 mm) copper.
30″ (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Electrical Requirements – U.S.A. Only

WARNIN

Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or electrical shock.

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded.  Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Electrical Connection
Check local codes and consult gas supplier. Check existing electrical supply and gas supply. See “Gas Supply Requirements” section.
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

  • Range must be connected to the proper electrical voltage and frequency as specified on the model/serial/rating plate. The model/serial/rating plate is located behind the oven door on the top right-hand side of the oven frame. A. Model/serial/rating plate (located behind the oven door on the top right-hand side of the oven frame)
  • This range is manufactured with a 4-wire power supply cord rated at 240 V, 40 A, rated at 194°F (90°C) and investigated for use with this range.
    Range Rating*| | Specified Rating of Power Supply Cord Kit and Circuit Protection
    ---|---|---
    120/240 V| 120/208 V| Ampere
    8.8-16.5 kW
    16.6-22.5 kW| 7.8-12.5 kW
    12.6-18.5 kW| 40 or 50**
    50

*The NEC calculated load is less than the total connected load listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.
For 50 A rated cord kits, use kits that specify use with a nominal 1⁄ 8 “(3.5 cm) diameter connection opening.

  • When a 4-wire, single phase 240 V, 60 Hz, AC only electrical 3 supply is available, a 40 A minimum circuit protection is required on 30″ (76.2 cm) ranges, fused on both sides of the line.
  • A time-delay fuse or circuit breaker is recommended.
  • This range is equipped with a UL or CSA International Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range’s final location.
  • Do not use an extension cord.
  • The wiring diagram is located on the back of the range or in a clear plastic bag.

Electrical Requirements – Canada Only

WARNIN

Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or electrical shock.

Be sure that the electrical connection and wire size are adequate and in conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 – latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■ Check with a qualified electrical installer if you are not sure the range is properly grounded.

Range Rating*| | Specified Rating of Power Supply Cord Kit and
Circuit Protection
---|---|---
120/240 V| 120/208 V| Ampere
8.8-16.5 kW
16.6-22.5 kW| 7.8-12.5 kW
12.6-18.5 kW| 40 or 50**
50

*The NEC calculated load is less than the total connected load listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.
For 50 A rated cord kits, use kits that specify use with a nominal 1 3 ⁄ 8 ” (3.5 cm) diameter connection opening.

  • When a 4-wire, single phase 240 V, 60 Hz, AC only electrical supply is available, a 40 A minimum circuit protection is required on 30″ (76.2 cm) ranges, fused on both sides of the line.
  • A time-delay fuse or circuit breaker is recommended.
  • This range is equipped with a UL or CSA International Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range’s final location.Whirlpool WSIS5030RZSS Induction Range - Electrical 2
  • Do not use an extension cord.
  • The wiring diagram is located on the back of the range or in a clear plastic bag.

IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Whirlpool ® appliances are appropriately UL, CUL or CSA approved.

®/™ ©2023 Whirlpool.
All rights reserved.
Used under license in Canada.
W11692339A

Documents / Resources

| Whirlpool WSIS5030RZSS Induction Range [pdf] User Guide
WSIS5030RZSS Induction Range, WSIS5030RZSS, Induction Range
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Whirlpool User Manuals

Related Manuals