AMREX U-HVGSO SynchroSonic Combination Ultrasound User Manual

June 3, 2024
AMREX

AMREX U-HVGSO SynchroSonic Combination Ultrasound

AMREX U-HVGSO SynchroSonic Combination Ultrasound-PRO

Combination Therapy At It’s Best

Combination therapy is designed for the combined simultaneous application of therapeutic ultrasonic energy and electrical stimulation through the transducer.

SynchroSonic U/HVG50

Three widely used therapeutic modalities are provided by the U/HVG50: low voltage galvanic (de) stimulation, high volt stimulation and ultrasound. Low voltage galvanic (de} allows the practitioner to conduct denervation testing or to perform iontophoresis applications. High volt stimulation produces no heat under the electrodes and therefore causes less tissue irritation. Ultrasound allows for increased cell permeability with greater metabolic exchange across the cell wall. While providing micro massage to the patient, the ultrasound produces an analgesic and thermal effect when applied to the nerve root and primary treatment site. Each of the three modalities may be applied separately or the ultrasound may be combined with either low voltage galvanic (de) or high volt stimulation simultaneously through the ultrasound transducer.

Optional Accessories

For greater convenience, this top-of-the-line full-range combination therapy unit can be easily wall-mounted or placed on our three-shelf, high-impact plastic utility cart.

Specifications

SynchroSonic U/HVG50 Combination Ultrasound with optional three-shelf utility cart

Input Power Requirements

  • Line Voltage ……………………………………………….. 120 Vac, 60 Hz Special voltage available on request)
  • Current …………………………………………… 1.0 A
  • Line Leakage ……………………………………….. < 50 µA

Ultrasonic Generator

(Complies with FDA Regulation 21 CFR 1050.10 nd FCC Regulations)

  • Frequency ………………………………………… 1.0 MHz ± 5%

  • Waveform ………………………………………. amplitude modulated a 120 Hz ± 1%

  • Pulse Duration ………………………………………. 8 ms ± 1%

  • Output Mode ………………………………………. adjustable interrupted & non-interrupted

  • Output Power ………………………………………. 0 to 20 W total ± 20% 0 to 5 W/cm2 ± 20%

  • Temporal Peakffemporal Average Intensity …………. 2.8:1 ± 20%

  • Treatment Timer ……………………………………….. adjustable 0 to 30 minutes

Applicator (Transducer)

  • Crystal Material ……………………………………………………………… … barium-titanate
  • Applicator Beam Type ………………………………………… collimating
  • Frequency ………………………………………… 1.0 MHz ± 5%
  • ERA (Effective Radiating Area) …………………………. 4 cm2 ± 20%
  • B R (Beam Nonuniformity Ratio) ………………….. 5.5:1 maximum
  • Small Faceplate Size ………………………………………. 1.5″ diameter
  • Standard Faceplate Size ………………………………………. 2.25″ diameter

Ultrasound Features

  • lightweight standard transducer
  • Optional QuickConnect… transducer
  • Optional small transducer with QuickConnect cable
  • Cable fault alarm system
  • Transducer protection switch
  • Adjustable interrupted output mode
  • 0 to 20 watt output · 30 minute timer

High Volt Stimulator Features

  • Dual channel, 4 pad high volt pulsed de stimulator
  • Selectable frequencies – pulsation to tetanize
  • Selectable surge and reciprocal rates – ramped
  • Intensity reset circuit
  • Combination therapy capability

Low Voltage Galvanic Features

  • Single channel, 2 pad low voltage galvanic (de)
  • 0 to 10 mA current for iontophoresis treatments
  • Adjustable surge and alternating polarity surge rates
  • Combination: iontophoresis/phonophoresis with FDA-approved substances
  • Two-Year Warranty – Generator – Parts and Labor
  • One-Year Warranty – Transducer – Parts and Labor
  • CSA Approved

Electrical Generator – High Volt

  • Waveform ……………… de “needle” pulses with no parasitic spike

  • Output Voltage ………………………………………. 0 to 500 peak V

  • Output Intensity ……………………………… 20 µC maximum charge per pulse into 100 .n toad

  • Pulse Width ……………………………………………………………… 30 µs

  • Frequency Range ……………………………….. 1 to 160 pulses per s

  • Reciprocal/Surge Duration ……………………………. 2.5, 5 and 10 s

Electrical Generator – Low Voltage Galvanic

  • Description ………….. variable constant current source de output

  • Output Intensity …………………………………………………. 0 lo 10 mA

  • Surge Duration …………….. variable 3.33 s on/off to 0.50 s on/off

  • Alternating Polarity Surge ……………. variable 3.33 s ± to 0.50 s ±

Instrument U/HVG50

  • Overall Dimensions …………………………… 19½” W x 11· D x 7″ H
  • Weight (including transducer) ………………………………. 18 lbs.
  • Shipping Weight ………………………………………………………. 27 lbs.

Ordering Information U/HVG50

  • Standard Sound head ………………………………………. 32-U/HVGS0
  • Standard Qu1ckConnect Sound head ………………. 32-U/HVG50-D
  • Small QuickConnect Soundhead ………………… 32-U/HVGS0-SM
  • Standard/Small QuickConnect Soundhead …….. 32-U/HVG50-D2

Caution: Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner