Product Information
The 4-in-1 Digital Soil Tester is designed to determine the pH level, temperature, moisture of the soil, and measure light intensity at the planting site for lawns, garden plants, and potted plants. It is intended for household use only and should not be used for commercial purposes.
Specifications:
- Art.-Nr.: 700403
- EAN: 4250679501780
- 4-in-1 Digital Soil Tester
Product Usage Instructions
General Instructions:
This manual and accompanying documents are essential for using the device.
Keep them carefully and pass them on when transferring the device.
Intended Use:
The soil tester is specifically designed for determining soil characteristics
and light intensity at planting sites. Do not use it for any other purposes.
Measurement Guidelines:
Before using the device, ensure it is not damaged. Take measurements at the
approximate planting site before planting. For more accurate results, take
multiple measurements at different spots.
Battery Safety Instructions:
- Battery Replacement: Follow the instructions provided in the manual for safe battery replacement.
Technical Specifications:
The technical specifications of the device can be found in the user manual.
FAQ:
-
Q: Can the soil tester be used for commercial purposes?
A: No, the soil tester is intended for household use only and should not be used commercially. -
Q: How should I clean and maintain the soil tester?
A: Refer to the “Cleaning and Maintenance” section in the user manual for detailed instructions on how to clean and maintain the soil tester.
GENERAL INSTRUCTIONS
This manual and any accompanying documents are part of the device and should be carefully kept and, if necessary, passed on when transferring the device.
INTENDED USE
This 4-in-1 soil tester is designed to determine the pH level, temperature,
and moisture of the soil, as well as measure the light intensity at the
planting site for lawns, garden plants, and potted plants. Any other use is
not intended. This product is not intended for commercial use and should only
be used in household settings.
LIABILITY
We do not assume any liability for property damage or personal injury caused
by improper handling or failure to follow this user manual and safety
instructions. In such cases, any warranty claims are void.
©COPYRIGHT
Lived non-food GmbH: All rights reserved. Company names and product names are
trademarks of their respective owners. No reproduction, transmission, copying,
or storage of this manual or parts thereof is permitted without the
manufacturer’s permission.
CONFORMITY DECLARATION.
This product complies with national, legal, and European requirements. The
conformity declaration for this product can be found at:
http://productip.com/?f=52e1d
SAFETY INSTRUCTIONS
- Despite a stable construction, residual risks exist, as with all electrical and electronic devices. The following safety and hazard instructions serve not only to protect the device but also to safeguard your health.
- For safety and certification reasons (CE), modification and/or alteration of the device are not permitted. Never disassemble the device.
- If you have doubts about its operation, connection, or safety, consult a professional or contact the manufacturer.
WARNING! Dangers to Children! This product is not a toy.
- Keep the device out of reach of children and pets.
- Do not leave packaging materials lying around. Children could play with plastic bags and suffocate.
- DANGER! Fire Hazard. Keep the product away from open flames or strong heat sources. Do not place near flammable materials or easily combustible objects. Avoid extreme heat or cold.
- CAUTION! Avoid direct contact with water or other liquids. Immersing the device or probe in liquids can cause damage or device failure.
- CAUTION! Do not apply excessive force when using the device. The probe may bend or break if pressed too forcefully into the soil.
BATTERY SAFETY INSTRUCTIONS
- Use the recommended 9-volt block battery (6F22 / 6LR61) for the device.
- Protect the battery from extreme heat, fire, or direct sunlight to prevent damage.
- Replace damaged or leaking batteries immediately.
- Remove the battery from the device when not in use to prevent energy loss or damage.
- Dispose of spent batteries according to local regulations.
- Keep batteries out of the reach of children or individuals who may not understand the hazards.
- Avoid excessive heat or short circuits to prevent explosion hazards.
BATTERY REPLACEMENT
- Please observe the battery safety instructions!
- Carefully open the battery compartment on the back of the housing.
- Connect the 9-volt block battery to the terminals, ensuring correct polarity.
- Place the battery into the battery compartment.
- Close the battery compartment. The cover should audibly click into place.
TECHNICAL SPECIFICATIONS
- Weight: approx. 73 g (without battery)
- Power Supply: 9-volt block battery
- Type: 6F22/6LR61
- Operating Temperature: +5°C to +40°C
- Storage Temperature: -10°C to +50°C
- Dimensions: 63 x 315 x 36 mm
- Probe Length: 20 cm
IMPORTANT MEASUREMENT GUIDELINES
CAUTION! Do not use the device if it is damaged. Before use, inspect the device for possible damage.
- Carefully clean the tip of the probe before each measurement.
- Insert the probe straight into the soil. Do not apply force. If you encounter resistance, try another spot.
- The probe must be positioned centrally between the plant stem and the edge of the pot. For large pots with a diameter exceeding 30.5 cm (approximately 12 inches), position the probe at 1/3 the distance from the rim to the plant stem.
- If the flowerpot is particularly deep, insert the probe into the soil until it reaches between the roots.
NOTES Temperature and moisture are measured simultaneously. Before planting, measure the approximate planting site, and for more precise results, conduct multiple measurements at different spots.
THE PRODUCT
Refer to image on page (1)
- Light sensor: Measures the incidence of light
- Display: Digital
- ON: Switching on the product
- °C/°F OFF: Select Celsius or Fahrenheit, Long press to switch off the product
- pH/°C: Select the measuring mode (pH value or moisture & temperature)
- Battery Compartment: At the rear of the product
- Measuring stick: With a sensor to stick into the soil
DISPLAY
NOTE: Before the first measurement, remove the protective film from the
display and the protective cap from the measuring probe.
- A. Light intensity
- B. pH-measuring is active
- C. Measured result of pH-value or temperature in °C or`°F
- D. Moisture
- E. Measuring of temperature is active
- F. Low battery warning
Power Off: The device will automatically power off if no button is pressed for approximately 4 minutes. Hold the °C/°F OFF button for about 3 seconds to manually turn off the device.
LIGHT INTENSITY MEASUREMENT
Position the device in the soil so that the light sensor faces the direction
of the strongest light exposure.
- Turn on the device using the ON button.
- The light intensity will be displayed on the screen.
- Compare the measurement result with the recommendations in the plant table (Chapter “Plant Table”).
Light Intensity Measurement Range: 9 Levels (LOW- to HGH+)
If the measured light intensity is higher/lower than the recommendation, relocate the plant to a spot with less/more sunlight.
SOIL PH MEASUREMENT
Set the measuring mode to pH. Insert the measuring probe into the soil. Turn
on the device using the ON button. The device will begin measuring. After some
time, you can read the measurement result on the display. Allow the device to
remain in the soil for a while to obtain a more accurate result. Compare the
measurement result with the recommendations in the plant table.
pH Value Measurement Range: 12 Levels (3.5 to 9.0; Display Resolution: 0.5)
LO and HH = The measurement result is outside the measurement range
- If the measured pH value is higher than the recommendation, add some granite meal, sulfur powder, or peat to the soil.
- If the measured pH value is lower than the recommendation, add some lime to the soil.
NOTE ON PH VALUE
The amount of acidity or alkalinity in the soil is measured using the “pH
value.”
- pH Value Below 7 = Acidic Soil
- pH Value of 7 = Neutral Soil
- pH Value Above 7 = Alkaline Soil
A high concentration of acid slows down the beneficial work of bacteria in the soil. Excessive alkali in the soil reduces nutrient levels and increases salt concentration, which hinders plant growth.
SOIL MOISTURE MEASUREMENT
- Set the measuring mode to °C.
- Insert the measuring probe into the soil.
- Turn on the device using the ON button.
- After some time, you can read the measurement result on the display. Allow the device to remain in the soil for a while to obtain a more accurate result.
- Compare the measurement result with the recommendations in the plant table.
Moisture Measurement Range: 5 Levels (Very Dry, Dry, Normal, Wet, Very
Wet)
Water Content at Test Site:
- DRY: Below 10%
- NOR: 10% to 20%
- WET: Above 20%
If the measured moisture is lower than the recommended level, water the plant until it reaches the recommended range. If the measured moisture is higher than the recommended level, refrain from watering until it reaches the recommended range.
SOIL TEMPERATURE MEASUREMENT
Temperature Measurement Range: -9°C to +50°C / 16°F to 122°F
- Set the measuring mode to °C.
- Insert the measuring probe into the soil.
- Turn on the device using the ON button.
- You can read the measurement result on the display. If the device is not in the soil, it will display the ambient temperature.
- Use the °C/°F OFF button to switch between Celsius and Fahrenheit units.
THE PACKAGE INCLUDES:
- Soil tester
- 1x block battery
- User manual
CLEANING AND MAINTENANCE
Clean the product using a soft cloth and avoid the use of solvents or
aggressive cleaning agents as they may damage the material.
NOTES: Remove the device from the soil after measuring. Do not use the
device in high-humidity environments. Do not leave the device outdoors; store
it in a dry indoor area. Never clean the product under running water, as this
will render it unusable.
DISPOSAL
Disconnect the battery from the device and dispose of it according to local
regulations for batteries and electronic waste. The consumer is legally
obliged to return electrical and electronic devices at the end of their
lifespan to designated public collection points for proper disposal and
recycling. Your local waste management company will announce the collection
point for electronic devices.
Batteries and accumulators must not be disposed of in household waste! Every consumer is legally obligated to deposit all batteries and accumulators, whether they contain pollutants such as Cd (Cadmium), Hg (Mercury), Pb (Lead), or not, at a collection point provided by the city or retailers, for proper and environmentally friendly disposal.
WARRANTY TERMS
2-year manufacturer’s warranty against material and manufacturing defects. Warranty coverage: Federal Republic of Germany. Proof of purchase is required. Free repair of material or manufacturing defects during the warranty period. No extension of the warranty period through a warranty service.
EXCLUSIONS FROM WARRANTY:
- Damages due to improper operation
- Wear and tear parts/accessories subjected to normal wear and tear
- Defects known to the customer at the time of purchase
- Damages resulting from repairs or interventions by the buyer or unauthorized third parties
- Connection of the device to a power supply with a higher voltage than specified
- Dropping the device or its components
- Improper transportation or inadequate packaging for transportation
- Damages caused by force majeure
- Failure to observe the applicable safety precautions for the device
- Batteries/accumulators are not covered by the warranty.
RETURN POLICY:
In the event of a valid warranty claim, we reserve the right to repair or
replace the defective device at our discretion, free of charge. The replaced
parts or products become our property. We reserve the right to exchange
defective parts or products for successor models. No additional claims beyond
this are available. If sending in the device has been arranged, please send it
securely packaged to our service department at your cost. Don’t forget to
include a copy of the purchase receipt. Always contact us first before sending
in the product. Repairs after the warranty period expires will incur charges.
Shipments sent without prepaid postage cannot be accepted and will be
automatically returned.
SERVICE ADRESSE
Lived non food GmbH
Friedrich-Seele-Straße 20
DE-38122 Braunschweig
+49 (0) 531 224356-81
info@lived-non-food.de
HERSTELLER
Lived non food GmbH
Friedrich-Seele-Straße 20
DE-38122 Braunschweig
www.lived-non-food.de
Stand 11.2023 | Technische
Änderungen vorbehalten.
Subject to technical changes.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>