EG4 UL1973 Wallmount Indoor 280Ah Lithium Battery User Guide

June 1, 2024
Eg4

EG4-logo

EG4 UL1973 Wallmount Indoor 280Ah Lithium Battery

Specifications

  • Model : WallMount Indoor 280Ah lithium battery
  • LED Indicator Lights: 2 (RUN/ALM)
  • SOC Indicator Lights : Ring of LEDs
  • Communication Interface: RS485, CAT 5, 5e, 6

Product Usage Instructions

  1. Front Panel Indicator Lights
    The front panel of the battery unit features LED indicator lights with the following functions:

  2. RUN/ALM Lights
    ALM (Red): Indicates a fault has occurred.
    RUN (Green, Static Blinking): Battery is in the idle state or charging/discharging

  3.  SOC Indicator Lights
    The ring of LED lights surrounding the EG4 logo indicates the state of charge of the unit based on the number and color of LEDs lit up as shown in the table provided.

BMS Communications
The battery communicates with compatible inverters using a Master battery designation and requires a specific communication protocol.

  1. Closed Loop Communications

  2. Power off all battery DC breakers and BMS power buttons.

  3. Change the inverter protocol with the master battery temporarily set to address 64. Restart the BMS after changing the DIP switch settings for the
    changes to take effect.

  4. Select the corresponding CAN protocol for EG4 inverters and change the DIP switch address back to 1 for inverter communications.
    The compatibility lists for closed-loop communications with EG4 inverters are provided in tables based on the communication protocol used.

FAQ

  • Q: How can I check the state of charge (SOC) of the battery?
    A: The ring of LED lights surrounding the EG4 logo indicates the SOC percentage based on the number and color of LEDs lit up.

  • Q: What is the procedure for changing the inverter protocol?
    A: To change the inverter protocol, follow the steps outlined in the user manual, including temporarily setting the master battery to address 64 and selecting the appropriate CAN protocol.

  • Q: Can the battery communicate with both inverter and software simultaneously?
    A: The battery cannot communicate with the software and a closed-loop inverter simultaneously. Ensure only one communication method is active at a time

EG4 ® WALL MOUNTINDOOR 280 Ah LITHIUM BATTERY
DEVICE MONITORING AND
SETTINGS GUIDE

The purpose of this document is to educate the end-user on the process of preparing the battery for wiring the power connections and paralleling connections.

The purpose of this document is to educate the end-user on the process of preparing the battery for wiring the power connections and paralleling connections.

  • ©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
  • VERSION 1.0
  • INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE.
  • MODEL#: WM-48|280-LL-00 / WM-48-280-1-IN-LL-00

FRONT PANEL INDICATOR LIGHTS

RUN/ALM LIGHTS
The WallMount Indoor 280Ah lithium battery features 2 LED status indicator lights on the front panel of the unit. Their functions are listed below:EG4-UL1973-Wallmount-Indoor-280Ah-Lithium-Battery-
\(1\)

The unit also features a ring of LED lights surrounding the EG4 logo that indicate the SOC (state of charge) of the unit. The table below provides detailed logic of the LED lights.

SOC % Number of LEDs Color
0%-15% 1 (lower quadrant) Red
16%-25% 1 (lower quadrant) Green
26%-50% 2 (lower, left quadrants) Green
51%-75% 3 (lower, left, right quadrants) Green
76%-100% 4 (all 4 quadrants) Green

BMS COMMUNICATIONS

  • EG4 batteries interface with compatible inverters by designating a “Master” battery (DIP switch ID No. 1).
  • The battery will connect directly to the inverter via an RS485 battery communications cable or a standard CAT 5, 5e, or 6 cable for closed loop communications with supported EG4 and non-EG4 inverters using CAN bus protocol.EG4-UL1973-Wallmount-Indoor-280Ah-Lithium-Battery- \(4\)
  • The PC software “BMS TOOLS” provides real-time battery analysis and diagnostics. The battery cannot communicate with the software and a closed loop inverter simultaneously.
  • Scan the QR code on the left for a video walking through the BMS Tools setup process.
  • EG4-UL1973-Wallmount-Indoor-280Ah-Lithium-Battery- \(2\)Scan the QR code on the right for a white sheet walking through the BMS Tools setup process.

 CLOSED LOOP COMMUNICATIONS

  1. Power off all battery DC breakers and BMS power buttons.
  2. The inverter protocol can only be changed with the master battery temporarily set to address 64 (all switches ON). After the DIP switch is changed, restart the BMS using the BMS power button for the settings to take effect. (See image)
  3. On the master battery, press and hold the “Return ” key for 5 seconds and release to enter the “Protocol Setting” menu.
  4. Select the corresponding CAN protocol (P01-EG4/LUX) for the system if using EG4 inverters,(See table below).
  5. Change the master DIP switch address back to address 1 for inverter communications & power cycle the BMS. (See image)EG4-UL1973-Wallmount-Indoor-280Ah-Lithium-Battery- \(4\)

The tables below show compatibility lists depending on the type of communication protocol used for closed-loop communications between battery and inverter.

CLOSED LOOP COMMS. WITH EG4 INVERTERS

MODEL| PROTOCOL SELECTION
18kPV/6000XP| CAN – P01
CAN PROTOCOL LIST

PROTOCOL #| MANUFACTURER
P01-EG4/LUX| EG4/LUX
P02-GRW| Growatt
P03-SLK| Sol-Ark
P04-DY| Deye
P05-MGR| Mangareva
P06-VCT| Victron
P07-LUX| Lux power
P08-SMA| SMA
RS485 PROTOCOL LIST

PROTOCOL #| MANUFACTURER
P01-EG4| EG4
P02-GRW| Growatt
P03-SCH| Schneider

NOTE: Both the CAN Protocol and RS485 Protocol menus are password protected. The password for each is “123456”.EG4-UL1973-Wallmount-Indoor-
280Ah-Lithium-Battery- \(6\)

NOTE: Closed loop communications using RS485 protocols require a specific pinout on the commas cable from battery to inverter. Refer to the table below for EG4 specifics.

EG4 INVERTER MODEL PROTOCOL COMMUNICATION CABLE PINOUT
18kPV CAN To inverter – RJ 45 Pin 4-H & Pin 5-L To battery – RJ 45 Pin 4-H &

Pin 5-L
RS485| To inverter – RJ45 Pins 7-A & 8-B To battery – RJ45 Pins 1-B & 2-A
6000XP| CAN| To inverter – RJ 45 Pin 4-H & Pin 5-L To battery – RJ 45 Pin 4-H & Pin 5-L
RS485| To inverter – RJ45 Pins 1-B & 2-A To battery – RJ45 Pins 1-B & 2-A
3000EHV (Legacy Product)| RS485|

  • To inverter – USB Type B
  • To battery – RJ45 Pins 1-B & 2-A

8KEXP (Legacy Product)| CAN| To inverter – RJ 45 Pin 4-H & Pin 5-L To battery – RJ 45 Pin 4-H & Pin 5-L
RS485| To inverter – RJ45 Pins 7-B & 8-A To battery – RJ45 Pins 1-B & 2-A
6000EX (Legacy Product)| RS485| To inverter – RJ45 Pins 3 & 5 To battery – RJ45 Pins 1-B & 2-A
6500EX (Legacy Product)| RS485| To inverter – RJ45 Pins 3 & 5 To battery – RJ45 Pins 1-B & 2-A

 FIRMWARE UPDATES

Always ensure all system components are fully up to date before commissioning the system. Navigate to the EG4 WallMount Indoor battery product page by visiting www.eg4electronics.com to find the latest firmware files. A PDF walkthrough will be included in the downloaded .zip file. If encountering difficulties during the updating process, contact the distributor for more information.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>