alnor HRU-WALL-WI-150-60 Decentralized Heat Recovery Units
Specifications
- Model: HRU-WALL-WI-150-60
- Air Flow [m3/h]: 20/40/60
- Power [W]: 1.4/2.3/3.8
- Weight [kg]: 4.3
Product Usage Instructions
Description of the Unit
The HRU-WALL is a decentralized, ductless ventilation unit with heat
recovery, designed to operate continuously and only be switched off for
maintenance or servicing. It is recommended to switch the unit to exhaust-only
mode or supply-only mode when heat exchange is not needed or not advised.
Safety
Ensure to follow safety precautions during installation and usage.
Technical Data
The technical specifications are as follows:
- Air Flow [m3/h]: 20/40/60
- Power [W]: 1.4/2.3/3.8
- Weight [kg]: 4.3
Operation
Application Installation and Device Pairing
- Ensure all devices are within the router’s range.
- Set the switch to the App position.
- Select “Connect new device”.
General information
Description of the unit
HRU-WALL is a single alternate flow decentralized (single point)
residential heat recovery unit, also called a «push» unit, designed to ensure
adequate ventilation in enclosed environments without energy losses. It is
recommended that two units are installed in pairs: when one unit is pulling,
the other is pushing. A pair of units can be installed in the same room or in
different rooms (i.e. living room and bedroom). The unit is suitable for
installation on an outside wall.
INFO: The unit should operate continuously, and only stop for maintenance or service. When heat exchange is not useful (for example in mid-season when indoor and outdoor temperatures are similar), or when heat exchange is not recommended (for example with the option “summer free cooling”), it is recommended to set the unit in “extract-only” or “intake-only” mode and NOT to switch it off.
How to use this manual
Read this manual carefully before using the product and keep it in a safe
place for reference.
Admonitions
- WARNING identifies a hazard that could lead to personal injury, including death
- NOTE is used to highlight additional information.
Safety
General safety instructions
This product was constructed up to standard and in compliance with
regulations relating to electrical equipment and must be installed by
technically qualified personnel. The manufacturer assumes no responsibility
for damage to persons or property resulting from failure to observe the
regulations contained in this manual.
Precautions for installation, use and maintenance
- The device should not be used for applications other than those specified in this manual.
- After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small children or people with disabilities.
- Do not touch the appliance with wet hands/feet.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
- Do not use the product in the presence of inflammable vapors, such as alcohol, insecticides, gasoline, etc.
- If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use original spare parts only for repairs.
- The electrical system to which the device is connected must comply with regulations.
- Before connecting the product to the power supply or the power outlet, ensure that: the data plate (voltage and frequency) correspond to those of the electrical mains and the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
- The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from any type of combustion unit. It must expel air outside via its own special duct.
- Operating temperature: -20°C up to +50°C.
- The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
- Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
- Do not immerse the device or its parts in water or other liquids.
- Turn off the main switch whenever a malfunction is detected or when cleaning.
- For installation an omnipolar switch should be incorporated in the fixed wiring, by the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- Do not obstruct the fan or exhaust grille to ensure optimum air passage.
- Ensure adequate air return/discharge into/from the room in compliance with existing regulations to ensure proper device operation.
- If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove, etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
Directives / Norms
- 2014/35/EU Low Voltage Directive (LVD) and 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following standards:
- Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003) +A1+A2.
- Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2 (2015); EN 61000-3-2(2014); EN 61000-3- 3(2013).
Technical data
Features
- Tube material: high quality, impact, and UV-resistant ABS colour RAL 9010.
- Design front cover removable for cleaning without the use of tools.
- Easy maintenance installation plate, for easy access to the heat exchanger from inside the room.
- Anti-dust filter, easily removable for washing by the user without tools.
- Regenerative honeycombs ceramic heat exchanger.
- External grille in high quality, external hood in aluminum, painted in white RAL 9010, acoustically lined.
- High-efficiency aerodynamic fan with “winglet” blades to optimize quietness and efficiency.
- Single phase EC reversible brushless motor with integral thermal protection.
- Motor mounted on high-quality ball bearings.
- The unit is double insulated: no earth connection is required.
- Trickle speed is selectable.
- Boost mode.
- Free-cooling (Bypass single direction) mode.
- IPX4 degree of protection.
- Power supply 220V to 240V~ 50Hz.
Technical specification
- Model: HRU-WALL-150-60
- Airflow [m3/h] : 20/40/60
- Power [W]: 1.4/2.3/3.8
- Weight [kg]: 4.3
Dimensions
Dimensions (mm)
Operation
The installation of the app and pairing of the device
Step 1.
Download the WallAIR Remote application from the Google Play or App Store and
install it on your Android or iOS device. An app installed on the smartphone
allows you to control a single heat recovery unit or a group of heat recovery
units within range of the WLAN (Wi-Fi network) (Wi-Fi network).
Step 2.
Make sure all devices are within the router’s range.
Set the jumper in the App position.
Step 3.
When the heat recovery unit is turned on, it creates a Wi-Fi access point
called HRU-WALL-150 which does not require a password. Connect the smartphone
to this access point. Next, run the application and go to „Settings”.
Step 4.
Then select „Connect a new device”.
Step 5.
Select your Wi-Fi network and enter the password (to which the HRU-WALL-WI and
smartphone/tablet will be connected).
Step 6.
Your smartphone should be reconnected to your Wi-Fi network. If this condition
is met, the application will proceed to the next screen.
Step 7.
Select the room in which the device is installed. You can also add a new
group.
Step 8.
Turn off the power to the heat recovery unit and set the jumper to RUN mode.
Step 9.
It is necessary to repeat the above steps for all HRU-WALL-WI-150-60 units.
Synchronization
- Synchronization of two or more units is done by adding these units to the same room in the application (see chapter 4. step 7.)
- You can change the synchronization options by clicking “Settings” in the application and changing the room selection.
Jumper positioning
- The integral jumper set in position A (Fig. 19A) means “extract-only” mode.
- The integral jumper set in position B (Fig. 19B) means “supply-only” mode.
The jumper position defines both the air-flow direction when the unit is activated for the first time (for the synchronisation) and the air-flow direction of the free-cooling mode.
Maintenance and service
- Maintenance can be carried out by the user as indicated at page 22.
- Service must be performed only by technically qualified personnel by local rules and regulations. Make sure that the main supply to the unit is disconnected (page 23).
- Cleaning of the heat exchanger can be performed from outside as well.
Disposal and recycling
- Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centers, or else send the product back to the retailer when purchasing a new, equivalent type device.
- Separate collection of decommissioned equipment for recycling, treatment, and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment.
- Improper disposal of the product by the user may result in administrative sanctions as provided by law.
Installation
Reset of the synchronization
OPTION 1
OPTION 2
Filter cleaning
Filter cleaning (maintenance)
NOTE: Filter cleaning can be carried out by the user.
Heat exchanger
Heat exchanger cleaning (service)
NOTE: Heat exchanger cleaning must be carried out only by technically
qualified personnel.
Energy Label
- Model: HRU-WALL-WI-150-60
- Sound power level Lwa [dB]: 38
- Airflow [m3/h]: 60
- Energy class: A
Product Regulations
Product fiche according to ERP Directive, Regulations 1253/2014, 1254/2014
Mark| ALNOR
Systemy Wentylacji
---|---
Model| HRU-WALL-100-25| HRU-WALL-150-60
Specific energy consumption (SEC) [kWh/(m2/rok)] (warm, average, cold
climates)| -15,6| -37,5| -75,6| -16,2| -38,2| -76,4
Energy class| A
Unit typology| Residential – bidirectional
Type of drive| multi-speed drive
Type of Heat Recovery System| heat recovery
Maximum thermal efficiency| 82%
at 70% at least of the maximum flow rate to the Regulation 1253/2014 and
1254/2014| 74%
Maximum flow rate| 25 m3/h| 60 m3/h
Electric power input at maximum flow rate| 2,6 W| 3,8 W
Sound power level (LWA)| 35 dBA| 38 dBA
Reference flow rate| 17 m3/h| 41 m3/h
Reference pressure difference| 10 Pa
Specific power input (SPI)| 0,071 W/m3/h| 0,054 W/m3/h
Control factor| 1| 1
Control typology| Manual control (no DCV)
Maximum internal leakage rate| N/A
Maximum external leakage rate| 1
Internal mixing rate| N/A
External mixing rate| N/A
Visual filter warning| N/A
Instructions to install regulated grilles| N/A
Internet address for pre/disassembly instructions|
www.alnor.com.pl
Airflow sensitivity to pressure variations| N/A
Indoor/outdoor air tightness| 21 m3/h| 60 m3/h
Annual electricity consumption (AEC) [kWh/year] (warm, average, cold
climates)| 1| 1| 1| 0.7| 0.7| 0.7
Annual heating saved (AHS) [kWh/year] ((warm, average, cold climates)| 18|
39.9| 78| 18.1| 40| 78.2
FAQ
Frequently Asked Questions
Q: How often should the filter be cleaned?
A: The filter should be cleaned every 3-6 months depending on usage and air quality.
Q: Can the unit be used in both summer and winter?
A: Yes, the unit can be used year-round, but it is recommended to adjust settings based on seasonal requirements.