alnor HRU-SlimAIR Suspended Heat Recovery Unit Instruction Manual

June 12, 2024
alnor

HRU-SlimAIR Suspended Heat Recovery Unit

Product Information: HRU-SlimAIR

The HRU-SlimAIR is a suspended heat recovery unit with a plate
heat exchanger. It is certified by the Passive House Institute and
can be used as a certified component in passive houses. It is
available in different versions, including HRU-SlimAIR-250,
HRU-SlimAIR-350, and HRU-SlimAIR-500. The unit features a PET
counterflow heat exchanger and an enthalpy counterflow heat
exchanger. All models of the HRU-SlimAIR can be equipped with the
Constant Flow system.

Dimensions

A B C D E F G H
160 mm 242 mm 685 mm 1172 mm 505 mm 1070 mm 143 mm 120 mm
200 mm 300 mm 735 mm 1292 mm 585 mm 1180 mm 126.5 mm 108.5 mm
200 mm 300 mm 898 mm 1416 mm 690 mm 1300 mm 153.7 mm 163 mm

Installation

The HRU-SlimAIR can be installed in different orientations
depending on the model. The SlimAIR-250 and SlimAIR-350 models can
be installed horizontally or vertically. The SlimAIR-500 model can
only be installed vertically.

For vertical installations, the HRQ-SlimAIR-HANG mounting rack
can be used to suspend the unit from the ceiling and mount it on
the wall. The mounting rack allows for easy installation by a
single person.

Technical Data

Model| Air Flow [m3/h] @ 100 Pa| Maximal Efficiency %| Efficiency % (acc. 1254/2014)| Maximal Moisture Efficiency %| Heat Exchanger| Voltage [V/Hz]| Maximum Power Consumption [W]| Sound Power Level LWA [dB (A)]| Weight [kg]| Filters
---|---|---|---|---|---|---|---|---|---|---
SlimAIR-250-H / SlimAIR-250-H-CF| 250| 89.9| 85.0| –| Counterflow PET| 230 / 50| 91.5| 50| 25.5| Built-in pre-heater
SlimAIR-250E-H / SlimAIR-250E-H-CF| 250| 85.6| 75.3| 63.3| Counterflow enthalpy| 230 / 50| 90.3| 50| 25.5| Pre-heater (optional)
SlimAIR-350 / SlimAIR-350-CF| 350| 94.0| 85.6| –| Counterflow PET| 230 / 50| 123.0| 49| 36.0| Built-in RH sensor (optional)
SlimAIR-350E / SlimAIR-350E-CF| 350| 91.0| 76.9| 87.0| Counterflow enthalpy| 230 / 50| 146.0| 49| 36.0| Pre-heater (optional)
SlimAIR-500 / SlimAIR-500-CF| 500| 95.2| 85.0| –| Counterflow PET| 230 / 50| 207.0| 51| 44.0| Built-in pre-heater, Built-in RH sensor (optional)
SlimAIR-500E / SlimAIR-500E-CF| 500| 89.0| 75.4| –| Counterflow enthalpy| 230 / 50| 247.0| 51| 44.0| Pre-heater (optional), Built-in RH sensor (optional)

Note: The technical data provided is in compliance with relevant
standards and regulations.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Dimensions

C

E

NSAUWPIPELWY

EWXTYCRIACGT

A+

F

D

Description
The HRU-SlimAIR heat recovery units are designed for residential buildings. The HRVs have capacities of 250/350/500 m3/h @ 100 Pa, generated by energy- efficient EC fans. Thanks to a counterflow heat exchanger made of a plastic (PET), it achieves up to 90% heat recovery An ERV version with an enthalpy exchanger that recovers moisture is also available. Built-in electric preheater protects heat exchanger against freezing, built-in RH sensors regulates indoor humidity level, wireless radio communication connects controllers and sensors, and all of it is enclosed inside a self-supporting, insulating EPP casing. HRU-SlimAIR can be installed in up to 3 positions, thanks to a special condensate drain system.

HRU-SlimAIR-250 is certified by Passive House Institute and can be used as a certified component in passive houses.

Available versions: HRU-SlimAIR-250-H HRU-SlimAIR-250E-H
HRU-SlimAIR-350 HRU-SlimAIR-350E
HRU-SlimAIR-500 HRU-SlimAIR-500E
HRU-SlimAIR-…-CF

– PET counterflow heat exchanger – enthalpy counterflow heat
exchanger – PET counterflow heat exchanger – enthalpy counterflow heat
exchanger – PET counterflow heat exchanger – enthalpy counterflow heat
exchanger
– all model PremAIR can be equipped with the Constant Flow system

WEXYRHZAUUTNSITA

OCZUETRDPNOIOA R

4xØA

B

G

H

A

B

C

D

E

F

G

H

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

SlimAIR-250 160 242 685 1172 505 1070 143 120

SlimAIR-350 200 300 735 1292 585 1180 126.5 108.5

SlimAir-500 200 300 898 1416 690 1300 153.7 163

l

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

721

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Installation
Suspended HRU-SlimAIR-250 / HRU-SlimAIR-350 / HRU-SlimAIR-500

Horizontal only HRU-SlimAIR-250 / HRU-SlimAIR-350

Equipment & accessories
2xM10 128

Vertical HRU-SlimAIR-250 / HRU-SlimAIR-350 / HRU-SlimAIR-500

HRQ-SlimAIR-HANG
With the optional HRQ-SlimAIR-HANG mounting rack, the HRV unit can be suspended from the ceiling and mounted on the wall vertically. A single person can hang the unit using the mounting rack.

A

60

B

A [mm]

B [mm]

HRQ-SlimAIR-250-HANG 509.5 386.5

l

HRQ-SlimAIR-350-HANG 587 464

HRQ-SlimAIR-500-HANG 689.5 586.6

Installation / Model
Suspended Vertical Horizontal

SlimAIR-250-H / SlimAIR-250-H-CF

SlimAIR-250E-H / SlimAIR-250E-H-CF

SlimAIR-350 / SlimAIR-350-CF

SlimAIR-350E / SlimAIR-350E-CF

SlimAIR-500 / SlimAIR-500-CF

X

SlimAIR-500E / SlimAIR-500E-CF

X

722

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Technical data

SlimAIR-250-H / SlimAIR-250E-H / SlimAIR-350 /

SlimAIR-350E /

SlimAIR-500 /

SlimAIR-250-H-CF SlimAIR-250E-H-CF SlimAIR-350-CF SlimAIR-350E-CF SlimAIR-500-CF

Air flow [m3/h] @ 100 Pa

250

250

350

350

500

Maximal efficiency %1

89.9

85.6

94.0

91.0

95.2

Efficiency % (acc. 1254/2014)2

85.0

75.3

85.6

76.9

85.0

Maximal moisture efficiency %

63.3

87.0

Heat exchanger

counterflow PET

counterflow enthalpy

counterflow PET

counterflow enthalpy

counterflow PET

Voltage [V/Hz]

230 / 50

230 / 50

230 / 50

230 / 50

230 / 50

Maximum power consumption [W]

91.5

90.3

123.0

146.0

207.0

Sound power level LWA[dB (A)] Weight [kg]

50 25.5

50 25.5

49 36.0

49 36.0

51 44.0

Filters Built-in pre-heater Pre-heater Built-in RH sensor

ISO Coarse 70% / ISO ePM1 55% (optional)

X

X

X

X

X

(optional)

(optional)

(optional)

SlimAIR-500E / SlimAIR-500E-CF
500 89.0 75.4 85.0 counterflow enthalpy 230 / 50 247.0 51 44.0
X (optional)

1 Maximal thermal efficiency acc. to EN13141-7 at minimum air flow 2 Thermal efficiency in reference point acc. to EN 13141-7, in compliance with UE 1254/2014

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

723

Equipment & accessories

Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors

Control
Ventilation units can be controlled in several ways:
Application for Android, iOS and via a browser (via the HRQ-GATE internet gateway)

Control via CO2 and RH sensors (we recommend as additional control).

Aplication

HRQ-GATE

The gateway is connected to the local network via the Ethernet port. Communication with the device is wireless. On-line control is possible after installing the application on Andriod and iOS or via a browser on a computer. The application graphically illustrates the operation of the device, allows you to change modes and read basic parameters.

Controller LCD, flush-mounted (HRQ-BUT-LCD) This version has an LCD display, allows you to select 1 of 7 operating modes, program the calendar and read additional operating parameters such as temperatures, current fan speeds or the by-pass status. It also allows you to configure ventilation speeds (according to user preferences).

4-button controller

HRQ-SENS-CO2

HRQ-SENS-RH

HRQ-SENS-I-CO2 (flush-mounted)
Each sensor also functions as a controller – it allows you to select from manual modes and, of course, engage AUTO mode. Indicates errors or dirty filters, but there is no filter status reset option.
Motion sensor HRQ-SENS-PIR
The sensor is designed to detect the presence of a person by motion detection and increase the ventilation demand (70% for 15 minutes). In addition, through a relay, the sensor can switch on the light.

HRQ-BUT-LM11

HRQ-BUT-LM04

This controller allows you to choose between 4 modes. The LM04 model has an AUTO button (instead of PARTY), recommended when there is at least 1 CO2 or RH sensor in the system. Signalling of operation and errors by means of a LED diode.

The HRQ-SW3-I rotary switch is an option for wired control of the ventilation unit and allows you to choose between 3 speeds (AWAY, HOME, HOME +)

Modbus gate (HRQ-MODBUS),
HRQ-MODBUS gate, which allows to control the device using the universal modbus protocol and RS485 data transmission.
NOTE! Controller is not included in the kit. During purchase, choose the controller that is right for you. Multiple controllers can be connected at once – e.g. 4-button controller and an Internet gateway.

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

757

Equipment & accessories

Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors

Control options table:

Model

Photo

HRQ-SW3-I

Communication with unit
cable

Power supply
230V

No of modes

AUTO mode*

Display

Calendar

Dirty filter signalization

Changing speed settings

3

no

no

no

no

no

HRQ-BUT-LM11

wireless

battery

4

no

no

no

yes

no

HRQ-BUT-LM04

wireless

battery

4

yes

no

no

yes

no

HRQ-BUT-LCD

wireless

230 V

7

yes

yes

yes

yes

yes

HRQ-GATE

wireless

230 V

6

yes

yes

no

yes

no

HRQ-SENS-CO2 HRQ-SENS-I-CO2

wireless

230 V

5

yes

no

no

yes

no

HRQ-SENS-RH

wireless

battery

4

yes

no

no

yes

no

HRQ-MODBUS

wireless

230 V

HRQ-MODBUS

wireless

n/d

7

yes

no

no

yes

no

  • requires at least 1 CO2 or RH sensor

758

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors

Constant Flow (CF)
SlimAIR air handling units optionally can be equipped with the Constant Flow system, whose task is to maintain a constant air flow in the installation. CF works by reading the difference between the dynamic pressure around the fan and the static pressure in the duct in front of the fan. The CF system constantly monitors the pressure in the ducts and if the resistance increases, it increases the speed of the fans to maintain a constant flow, such as on the first day when the ventilation unit was commissioned. During exploitation, the installation pressure is naturally disrupted (dirty filters, condensation of water in the heat exchanger, temperature difference changing the air mass). CF counteracts to those changes, thanks to which the airflows remain sustainable, and only a sustainable system takes full advantage of the air handling unit’s capabilities.
Zoning
HRQ-2ZONE is a device designed for residential ventilation systems, dividing the air supply into two controlled and monitored zones. The air flow is controlled by motorized dampers, which are adjusted according to the demand sent by CO2 sensors installed in each zone. Such a system allows for the detection of the habitant’s presence and provides the right amount of fresh air in the right place at the right time.
Connecting the ground heat exchanger
Heat recovery unit has a possibility to connect the ground heat exchanger. This function allows you to control a valve that optionally supply air through the ground-to-air heating system. To do this, install a dedicated damper with the actuator (DATVTML).

Demand Control Ventilation, DCV

The AUTO mode is the most energy-efficient and demand driven mode of SlimAIR units. Operation in the AUTO mode is possible when at least one carbon dioxide CO2 or relative humidity RH sensor operates in the system. In AUTO mode, the sensor (or several sensors) generates the so-called ventilation demand based on ambient air measurements. This request is sent wirelessly to the control board, which sets the efficiency of the fans in the range defined by AWAY and HOME(+ offset) speeds. It means, that in the case of factory settings, the range will be 15-70%. The RH sensor will guard against excessive moisture. If there is a sudden increase in relative humidity (more than 3% within 24 seconds) or the reading exceeds 85%, the sesnor will send 100% demand to the control panel to effectively and quickly reduce the RH level. The CO2 sensor will keep the carbon dioxide concentration below the specified level (the factory default is 800 ppm, you can choose between 700,800,900,1000 and 1100 ppm) thanks to the proportional PID algorithm. This means that the request sent to the control board will change gradually over time until the CO2 concentration decreases. HRU-PremAIR-SENS-C02 sensors have 2 AUTO modes: Comfort and Eco. Comfort is the basic setting (i.e. 800 ppm by default), while Eco increases the limit by 250 (i.e. 1050 by default).

The CO2 sensor is available in the following versions:

surface

flush-mounted

HRQ-SENS-CO

HRQ-SENS-I-CO2

In case of having several sensors, the unit control board will operate according to the highest indication (highest request). In the absence of any demand from the sensors, the ventilation unit will run at AWAY speed (lowest setting).

Cooperation with the kitchen hood
The cooker hood can be connected to the MVHR system via the X25 contact on the main board of the SlimAIR heat recovery units. It is a potential-free contact. Short-circuits of contact inputs will result in an exhaust fan stopping completely during the period the contact is closed.

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

759

Equipment & accessories

Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors
Mobile application PremAIR
Mobile application for controlling a home ventilation unit HRU-SlimAIR, HRU- PremAIR and HRU-MinistAIR by ALNOR. It allows to monitor and control the unit via local network and Internet as well:
· Mode selection (Away, Home, Party, Boost, Auto and Standby)
· Temperature readouts · Registering and displaying remote CO2 and RH sensors
readouts · Fans efficiencies · Defrost mode · By-pass mode · Filters conditions
Available for download in Google Play and App Store: PremAIR Also via web browser: https://premair.alnor.pl/
Screen shot:

760

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Equipment & accessories Cinienie calkowite [Pa] Total pressure [Pa]

Air flow and efficiency

HRU-SlimAIR-250-H
400

350

300

250

200

high

150

med.

100

SUPPLY
max

EXHAUST

cinienie calkowite [Pa] Total pressure [Pa] cinienie [Pa]

400

350
HRU-SlimAIR-250E-H
400
300
350

320500
225000 200 med
150
150
110000

high
high med.

max
SUPPLY
max

EXHAUST
400 350 300 250 200 150 100

Cinienie calkowite [Pa]

50

300

50 low

0

0

50

100

150

200

250

300

PrzAepirlywflopowwie[tmrza3[/mh3]/h]

50
50

lowlow

50

0

0

0

50

100

150

200

250

300

0 0

50

100

1p50rzeApliyr2w00flpoowwie2t5[r0zma [3m/h330/]0h] 350

400

450

przeplyw [m3/h]

HRU-SlimAIR-350

SUPPLY

400
250m3/h (pmrzaxy 100 Pa)
350

EXHAUST

HRU-SlimAIR-350E
250m3/h (przy 100 Pa)
400 max
350

SUPPLY

EXHAUST

Total pressure [Pa] cinienie [Pa]

Total pressure [Pa] cinienie [Pa]

300
250 high
200 med
150

300 high
250
200 med
150

100

50

low

100
low 50

0

0

50

100

150

200

250

300

350

400

450

Air pflrzeoplwyw [m[3m/h] 3/h]

0

0

50

100

150

200

250

300

350

400

450

Air pflrzeoplyww [m[3m/h] 3/h]

724

HRU-SlimAIR-500 400 400

335500

Total pressure [Pa] Cinienie calkowite [Pa] cinienie [Pa]

300 300

250

high

225000

150 200 100 med 150
50
1000 0 low
50

low 100

SUPPLY
max

EXHAUST

max high med

200

300

400

500

600

Przeplyw powietrza [m3/h] Air flow [m3/h]

ALNOR® ventilation systems 0

0

50

100

150

200

250

300

350

400

450

przeplyw [m3/h]

is a legally protected trademark and technical patent. All rights reserved.

l
Suspended heat recovery unit with la plate heat exchanger
HRU-SlimAIR

Equipment & accessories

Performance curve HRU-SlimAIR-250-H

Efficiency [%] Odzysk [%]

90 88 86 84 82 80 78 76 74 72 70
0

50

100

150

200

250

300

PrzepAlyiwr pfloowwietr[zma [m3/h3/]h]

l

l

l

Performance curve Heat ( )andmoisturl e recovery ( )
HRU-SlimAIR-250E-H 90

EfficOidezynskc [y%[]%]

80 l 70
60

l

l

l

l

50

l

40 l

30 0

50

100

150

200

250

300

PrzepAlyiwr pfloowwiet[rzma 3[m/h3]/h]

EffiOcdizyeskn[c%]y [%]

Performance curve HRU-SlimAIR-350

97 95 93 91 89 87 85 83 81
0

50

100 150 200 250 300 350 400

ll
Air

flow

[m3/h]

l

Performance curve Heat ( )andmoisturl e recovery ( ) HRU-SlimAIR-350E

EfficOidzeyskn[c%]y [%]

94 90 86 l 82 78 74 70 l 66 62
0

l

l

l

l

50

100

150

200

250

300

350

l
Air

flow

[m3/h]

l

Efficiency [%]

l

l

Performance curve HRU-SlimAIR-500

Performance curve Heat ( )andmoisturl e recovery ( ) HRU-SlimAIR-500E

95

93

91

89

87

85

83

81

79

77 0

50

100 150 200 250 300 350 400 450 500 550

Airl flow [m3/h]

EfficiOedzynskc [y%][%]

95 90 85 80 l 75 70 65 60 55 50
0

l

50

100 150 200l 250 300 350 400 450 500 550

Airl flow [m3/h]

l
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

725

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Filters

Pleated panel filter creates a larger media surface area for air filtration and ensures lower pressure drops. The filter is classified as in the ISO Coarse 70% or ISO ePM1 55% according to ISO 16890 standards.

Code
HRQ-SlimAIR-FILT-C70 HRQ-SlimAIR-350-FILT-C70 HRQ-SlimAIR-500-FILT-C70

Filter clas
ISO Coarse 70% ISO Coarse 70% ISO Coarse 70%

Dimensions [mm] 170x334x23 220x314x23 218x432x23

HRQ-SlimAIR-FILT-ePM155 HRQ-SlimAIR-350-FILT-ePM155 HRQ-SlimAIR-500-FILT- ePM155

ISO ePM1 55% ISO ePM1 55% ISO ePM1 55%

170x334x23 220x314x23 218x432x23

Filter replacement: bottom access

side access

726

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Smart ventilation system SmartAIR
SmartAIR heat recovery system with zoning is the most intelligent, efficient system on the market. Why is it intelligent? The ventilation system works independently, based on readings from sensors. Besides knowing how many people are in the house, the system also knows where they are. Thus, it provides the right amount of air at the right time and place. A situation like this can be achieved by zoning, i.e. by dividing the house into day and night zones in accordance with the natural cycle of the day of the household members.
Find out more about the HRQ-2ZONE

Complete EPP system
Choose thermally insulated EPP ducting. High mechanical strength, pre- insulated, and quick to assemble. You don’t need an additional insulation layer. It comes in 15/43mm thicknesses.
EPP manifolds (distribution boxes) Manifolds FLX-PLO-EPP-R are designed for use in domestic mechanical ventilation systems. They collect 75mm semirigid ducting, which is then distributed to the rooms. Typical installations contain from 1 to 2 such manifolds for the supply air and the extract air. Expanded polypropylene (EPP), the material used for the manifolds, is also an insulating material.
Duct and fittings made of EPP in thickness 15 or 43 mm.
Check the elements of the EPP System?

Duct-mounted humidifier

The adiabatic humidifier is designed for domestic mechanical ventilation systems with a maximum airflow 600 m3/h. Filtered water naturally evaporates on a special matrix, and then the humidified air is distributed to the ventilation duct system and to the connected rooms. The humidification process is regulated by a wireless room controller and a duct sensor. Built-in PTC heater compensates for temperature losses caused by the evaporation process. The housing is made of EPP, while the matrix is made of fiber glass.

Find out more about duct humidifier

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

727

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Ecodesign Data

Energy class

Model

Sound power
level LWA dB(A)* [dB]

HRU-SlimAIR-250-H

50

HRU-SlimAIR-250-H-CF

50

HRU-SlimAIR-250E-H

50

HRU-SlimAIR-250E-H-CF

50

HRU-SlimAIR-350

49

HRU-SlimAIR-350-CF

49

HRU-SlimAIR-350E

49

HRU-SlimAIR-350E-CF

49

HRU-SlimAIR-500

51

HRU-SlimAIR-500-CF

51

HRU-SlimAIR-500E

51

HRU-SlimAIR-500E-CF

51

Air flow rate [m3/h] 250 250 250 250 350 350 350 350 500 500 500 500

Manual control
A A A A A A A A A A B B

Clock control
A A A A A A A A A A A A

Energy class
Central demand control (1 sensor)
A A A A A A A A A A A A

Local demand control (2 sensor)
A+ A+ A A A+ A+ A A A+ A+ A A

HRU-SlimAIR-250-H-CF
A+

HRU-SlimAIR-350-CF
A+

HRU-SlimAIR-500-CF
A+

50

250 m3/h

dB

49

350 m3/h

dB

51

500 m3/h

dB

ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI

2018

1254/2014

ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI

2018

1254/2014

ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI

2018

1254/2014

728

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-250-H

HRU-SlimAIR-250-H

HRU-SlimAIR-250-H

HRU-SlimAIR-250-H

HRU-SlimAIR-250-H-CF HRU-SlimAIR-250-H-CF HRU-SlimAIR-250-H-CF HRU- SlimAIR-250-H-CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-73.63 -36.71 -12.93 -74.79 -37.64 -13.73 -76.99 -39.39 -15.22 -80.98 -42.46 -17.77

(cold, average, warm climate)

SEC class

A+

A

E

A+

A

E

A+

A

E

A+

A+

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

85.00%

85.00%

85.00%

85.00%

Maximum flow rate [m3/h]2

250

250

250

250

Maxium electric power input [W]

91.5

91.5

91.5

91.5

Sound power LWA [dB(A)]

50

50

50

50

Reference flow rate [m3/s]3

0.049

0.049

0.049

0.049

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.23

0.23

0.23

0.23

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 1.14% Internal: 2.45%

External: 1.14% Internal: 2.45%

External: 1.14% Internal: 2.45%

External: 1.14% Internal: 2.45%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk

www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

865 328 283 837 300 255 786 249 204 702 165 120

The annual heating saved (AHS) [kWh/a/100m2]

8652 4423 2000 8699 4474 2011 8792 4494 2032 8979 4590 2075

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

729

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H-CF HRU-SlimAIR-250E-H-CF HRU-SlimAIR-250E-H-CF HRU-SlimAIR- 250E-H-CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-68.01 -34.05 -11.96 -69.43 -35.09 -12.79 -72.17 -37.07 -14.34 -77.24 -40.64 -17.04

(cold, average, warm climate)

SEC class

A+

A

E

A+

A

E

A+

A

E

A+

A

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

75.30%

75.30%

75.30%

75.30%

Maximum flow rate [m3/h]2

250

250

250

250

Maxium electric power input [W]

90.3

90.3

90.3

90.3

Sound power LWA [dB(A)]

50

50

50

50

Reference flow rate [m3/s]3

0.049

0.049

0.049

0.049

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.21

0.21

0.21

0.21

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 0.67% Internal: 0.79%

External: 0.67% Internal: 0.79%

External: 0.67% Internal: 0.79%

External: 0.67% Internal: 0.79%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

848 311 266 822 285 240 774 237 192 694 157 112

The annual heating saved (AHS) [kWh/a/100m2]

8047 4114 1860 8124 4153 1878 8278 4232 1914 8586 4389 1985

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

730

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-350 HRU-SlimAIR-350-CF

HRU-SlimAIR-350 HRU-SlimAIR-350-CF

HRU-SlimAIR-350 HRU-SlimAIR-350-CF

HRU-SlimAIR-350 HRU-SlimAIR-350-CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-74.43 -37.32 -13.44 -75.52 -38.20 -14.19 -77.62 -39.85 -15.59 -81.40 -42.76 -18.00

(cold, average, warm climate)

SEC class

A+

A

E

A+

A

E

A+

A

E

A+

A+

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

85.60%

85.60%

85.60%

85.60%

Maximum flow rate [m3/h]2

350

350

350

350

Maxium electric power input [W]

123

123

123

123

Sound power LWA [dB(A)]

49

49

49

49

Reference flow rate [m3/s]3

0.068

0.068

0.068

0.068

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.21

0.21

0.21

0.21

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk

www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

848 311 266 822 285 240 774 237 192 694 157 112

The annual heating saved (AHS) [kWh/a/100m2]

8689 4442 2009 8734 4465 2019 8824 4511 2040 9003 4602 2081

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

731

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-350E

HRU-SlimAIR-350E

HRU-SlimAIR-350E

HRU-SlimAIR-350E

HRU-SlimAIR-350E-CF HRU-SlimAIR-350E-CF HRU-SlimAIR-350E-CF HRU-SlimAIR-350E- CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-68.49 -34.04 -11.67 -69.91 -35.10 -12.54 -72.64 -37.13 -14.16 -77.66 -40.75 -16.97

(cold, average, warm climate)

SEC class

A+

A

E

A+

A

E

A+

A

E

A+

A

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

76.90%

76.90%

76.90%

76.90%

Maximum flow rate [m3/h]2

350

350

350

350

Maxium electric power input [W]

146

146

146

146

Sound power LWA [dB(A)]

49

49

49

49

Reference flow rate [m3/s]3

0.068

0.068

0.068

0.068

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.25

0.25

0.25

0.25

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 0.71% Internal: 2.66%

External: 0.71% Internal: 2.66%

External: 0.71% Internal: 2.66%

External: 0.71% Internal: 2.66%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

868 331 286 840 303 258 789 252 207 703 166 121

The annual heating saved (AHS) [kWh/a/100m2]

8147 4165 1883 8219 4201 1900 83.63 4275 1933 8651 4422 2000

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

732

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-500 HRU-SlimAIR-500-CF

HRU-SlimAIR-500 HRU-SlimAIR-500-CF

HRU-SlimAIR-500 HRU-SlimAIR-500-CF

HRU-SlimAIR-500 HRU-SlimAIR-500-CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-73.54 -36.62 -12.84 -74.71 -37.56 -13.65 -76.93 -39.32 -15.15 -80.95 -42.42 -17.73

(cold, average, warm climate)

SEC class

A+

A

E

A+

A

E

A+

A

E

A+

A+

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

85.00%

85.00%

85.00%

85.00%

Maximum flow rate [m3/h]2

500

500

500

500

Maxium electric power input [W]

207

207

207

207

Sound power LWA [dB(A)]

51

51

51

51

Reference flow rate [m3/s]3

0.097

0.097

0.097

0.097

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.23

0.23

0.23

0.23

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 1.3% Internal: 2.98%

External: 1.3% Internal: 2.98%

External: 1.3% Internal: 2.98%

External: 1.3% Internal: 2.98%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk

www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

868 331 286 840 303 258 789 252 207 703 166 121

The annual heating saved (AHS) [kWh/a/100m2]

8652 4423 2000 8699 4447 2011 8792 4494 2032 8979 4590 2075

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

733

Equipment & accessories

Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR

Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex

Supplier’s name or trade mark

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

ALNOR Systemy Wentylacji

Model identifier

HRU-SlimAIR-500E

HRU-SlimAIR-500E

HRU-SlimAIR-500E

HRU-SlimAIR-500E

HRU-SlimAIR-500E-CF HRU-SlimAIR-500E-CF HRU-SlimAIR-500E-CF HRU-SlimAIR-500E- CF

Specific energy consuption

(SEC) [kWh/(m2.a)]

-67.02 -33.02 -10.92 -68.54 -34.17 -11.85 -71.46 -36.33 -13.59 -76.83 -40.21 -16.60

(cold, average, warm climate)

SEC class

A+

B

E

A+

A

E

A+

A

E

A+

A

E

Declared typology

Bidirectional

Bidirectional

Bidirectional

Bidirectional

Type of drive

Variable

Variable

Variable

Variable

Type of heat recovery system

Recuperative

Recuperative

Recuperative

Recuperative

Thermal efficiency1

75.40%

75.40%

75.40%

75.40%

Maximum flow rate [m3/h]2

500

500

500

500

Maxium electric power input [W]

247

247

247

247

Sound power LWA [dB(A)]

51

51

51

51

Reference flow rate [m3/s]3

0.097

0.097

0.097

0.097

Reference pressure difference [Pa]4

50

50

50

50

SPI [W/(m3/h)]5

0.25

0.25

0.25

0.25

Control facotr

1

0.95

0.85

0.65

Declared maxiumum leakages6

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

External: 1.18% Internal: 2.74%

Position and description of visual filter warning

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Visual on status LED light on unit and on status LED light on
controller

Internet address for pre-/dis-assemlby instructions

www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk

The annual electricity consumption (AEC) [kWh/a/100m2]

890 353 308 860 323 278 804 267 222 712 175 130

The annual heating saved (AHS) [kWh/a/100m2]

8054 4117 1862 8130 4156 1879 8284 4234 1915 8590 4391 1986

1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010

734

ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

alnor User Manuals

Related Manuals