alnor HRU-SlimAIR Suspended Heat Recovery Unit Instruction Manual
- June 12, 2024
- alnor
Table of Contents
HRU-SlimAIR Suspended Heat Recovery Unit
Product Information: HRU-SlimAIR
The HRU-SlimAIR is a suspended heat recovery unit with a plate
heat exchanger. It is certified by the Passive House Institute and
can be used as a certified component in passive houses. It is
available in different versions, including HRU-SlimAIR-250,
HRU-SlimAIR-350, and HRU-SlimAIR-500. The unit features a PET
counterflow heat exchanger and an enthalpy counterflow heat
exchanger. All models of the HRU-SlimAIR can be equipped with the
Constant Flow system.
Dimensions
A | B | C | D | E | F | G | H |
---|---|---|---|---|---|---|---|
160 mm | 242 mm | 685 mm | 1172 mm | 505 mm | 1070 mm | 143 mm | 120 mm |
200 mm | 300 mm | 735 mm | 1292 mm | 585 mm | 1180 mm | 126.5 mm | 108.5 mm |
200 mm | 300 mm | 898 mm | 1416 mm | 690 mm | 1300 mm | 153.7 mm | 163 mm |
Installation
The HRU-SlimAIR can be installed in different orientations
depending on the model. The SlimAIR-250 and SlimAIR-350 models can
be installed horizontally or vertically. The SlimAIR-500 model can
only be installed vertically.
For vertical installations, the HRQ-SlimAIR-HANG mounting rack
can be used to suspend the unit from the ceiling and mount it on
the wall. The mounting rack allows for easy installation by a
single person.
Technical Data
Model| Air Flow [m3/h] @ 100 Pa| Maximal Efficiency %| Efficiency % (acc.
1254/2014)| Maximal Moisture Efficiency %| Heat Exchanger| Voltage [V/Hz]|
Maximum Power Consumption [W]| Sound Power Level LWA [dB (A)]| Weight [kg]|
Filters
---|---|---|---|---|---|---|---|---|---|---
SlimAIR-250-H / SlimAIR-250-H-CF| 250| 89.9| 85.0| –| Counterflow PET| 230 /
50| 91.5| 50| 25.5| Built-in pre-heater
SlimAIR-250E-H / SlimAIR-250E-H-CF| 250| 85.6| 75.3| 63.3| Counterflow
enthalpy| 230 / 50| 90.3| 50| 25.5| Pre-heater (optional)
SlimAIR-350 / SlimAIR-350-CF| 350| 94.0| 85.6| –| Counterflow PET| 230 / 50|
123.0| 49| 36.0| Built-in RH sensor (optional)
SlimAIR-350E / SlimAIR-350E-CF| 350| 91.0| 76.9| 87.0| Counterflow enthalpy|
230 / 50| 146.0| 49| 36.0| Pre-heater (optional)
SlimAIR-500 / SlimAIR-500-CF| 500| 95.2| 85.0| –| Counterflow PET| 230 / 50|
207.0| 51| 44.0| Built-in pre-heater, Built-in RH sensor (optional)
SlimAIR-500E / SlimAIR-500E-CF| 500| 89.0| 75.4| –| Counterflow enthalpy| 230
/ 50| 247.0| 51| 44.0| Pre-heater (optional), Built-in RH sensor (optional)
Note: The technical data provided is in compliance with relevant
standards and regulations.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Dimensions
C
E
NSAUWPIPELWY
EWXTYCRIACGT
A+
F
D
Description
The HRU-SlimAIR heat recovery units are designed for residential buildings.
The HRVs have capacities of 250/350/500 m3/h @ 100 Pa, generated by energy-
efficient EC fans. Thanks to a counterflow heat exchanger made of a plastic
(PET), it achieves up to 90% heat recovery An ERV version with an enthalpy
exchanger that recovers moisture is also available. Built-in electric
preheater protects heat exchanger against freezing, built-in RH sensors
regulates indoor humidity level, wireless radio communication connects
controllers and sensors, and all of it is enclosed inside a self-supporting,
insulating EPP casing. HRU-SlimAIR can be installed in up to 3 positions,
thanks to a special condensate drain system.
HRU-SlimAIR-250 is certified by Passive House Institute and can be used as a certified component in passive houses.
Available versions: HRU-SlimAIR-250-H HRU-SlimAIR-250E-H
HRU-SlimAIR-350 HRU-SlimAIR-350E
HRU-SlimAIR-500 HRU-SlimAIR-500E
HRU-SlimAIR-…-CF
– PET counterflow heat exchanger – enthalpy counterflow heat
exchanger – PET counterflow heat exchanger – enthalpy counterflow heat
exchanger – PET counterflow heat exchanger – enthalpy counterflow heat
exchanger
– all model PremAIR can be equipped with the Constant Flow system
WEXYRHZAUUTNSITA
OCZUETRDPNOIOA R
4xØA
B
G
H
A
B
C
D
E
F
G
H
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
SlimAIR-250 160 242 685 1172 505 1070 143 120
SlimAIR-350 200 300 735 1292 585 1180 126.5 108.5
SlimAir-500 200 300 898 1416 690 1300 153.7 163
l
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
721
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Installation
Suspended HRU-SlimAIR-250 / HRU-SlimAIR-350 / HRU-SlimAIR-500
Horizontal only HRU-SlimAIR-250 / HRU-SlimAIR-350
Equipment & accessories
2xM10 128
Vertical HRU-SlimAIR-250 / HRU-SlimAIR-350 / HRU-SlimAIR-500
HRQ-SlimAIR-HANG
With the optional HRQ-SlimAIR-HANG mounting rack, the HRV unit can be
suspended from the ceiling and mounted on the wall vertically. A single person
can hang the unit using the mounting rack.
A
60
B
A [mm]
B [mm]
HRQ-SlimAIR-250-HANG 509.5 386.5
l
HRQ-SlimAIR-350-HANG 587 464
HRQ-SlimAIR-500-HANG 689.5 586.6
Installation / Model
Suspended Vertical Horizontal
SlimAIR-250-H / SlimAIR-250-H-CF
SlimAIR-250E-H / SlimAIR-250E-H-CF
SlimAIR-350 / SlimAIR-350-CF
SlimAIR-350E / SlimAIR-350E-CF
SlimAIR-500 / SlimAIR-500-CF
X
SlimAIR-500E / SlimAIR-500E-CF
X
722
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Technical data
SlimAIR-250-H / SlimAIR-250E-H / SlimAIR-350 /
SlimAIR-350E /
SlimAIR-500 /
SlimAIR-250-H-CF SlimAIR-250E-H-CF SlimAIR-350-CF SlimAIR-350E-CF SlimAIR-500-CF
Air flow [m3/h] @ 100 Pa
250
250
350
350
500
Maximal efficiency %1
89.9
85.6
94.0
91.0
95.2
Efficiency % (acc. 1254/2014)2
85.0
75.3
85.6
76.9
85.0
Maximal moisture efficiency %
–
63.3
–
87.0
–
Heat exchanger
counterflow PET
counterflow enthalpy
counterflow PET
counterflow enthalpy
counterflow PET
Voltage [V/Hz]
230 / 50
230 / 50
230 / 50
230 / 50
230 / 50
Maximum power consumption [W]
91.5
90.3
123.0
146.0
207.0
Sound power level LWA[dB (A)] Weight [kg]
50 25.5
50 25.5
49 36.0
49 36.0
51 44.0
Filters Built-in pre-heater Pre-heater Built-in RH sensor
ISO Coarse 70% / ISO ePM1 55% (optional)
X
X
X
X
X
(optional)
(optional)
(optional)
SlimAIR-500E / SlimAIR-500E-CF
500 89.0 75.4 85.0 counterflow enthalpy 230 / 50 247.0 51 44.0
X (optional)
1 Maximal thermal efficiency acc. to EN13141-7 at minimum air flow 2 Thermal efficiency in reference point acc. to EN 13141-7, in compliance with UE 1254/2014
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
723
Equipment & accessories
Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors
Control
Ventilation units can be controlled in several ways:
Application for Android, iOS and via a browser (via the HRQ-GATE internet
gateway)
Control via CO2 and RH sensors (we recommend as additional control).
Aplication
HRQ-GATE
The gateway is connected to the local network via the Ethernet port. Communication with the device is wireless. On-line control is possible after installing the application on Andriod and iOS or via a browser on a computer. The application graphically illustrates the operation of the device, allows you to change modes and read basic parameters.
Controller LCD, flush-mounted (HRQ-BUT-LCD) This version has an LCD display, allows you to select 1 of 7 operating modes, program the calendar and read additional operating parameters such as temperatures, current fan speeds or the by-pass status. It also allows you to configure ventilation speeds (according to user preferences).
4-button controller
HRQ-SENS-CO2
HRQ-SENS-RH
HRQ-SENS-I-CO2 (flush-mounted)
Each sensor also functions as a controller – it allows you to select from
manual modes and, of course, engage AUTO mode. Indicates errors or dirty
filters, but there is no filter status reset option.
Motion sensor HRQ-SENS-PIR
The sensor is designed to detect the presence of a person by motion detection
and increase the ventilation demand (70% for 15 minutes). In addition, through
a relay, the sensor can switch on the light.
HRQ-BUT-LM11
HRQ-BUT-LM04
This controller allows you to choose between 4 modes. The LM04 model has an AUTO button (instead of PARTY), recommended when there is at least 1 CO2 or RH sensor in the system. Signalling of operation and errors by means of a LED diode.
The HRQ-SW3-I rotary switch is an option for wired control of the ventilation unit and allows you to choose between 3 speeds (AWAY, HOME, HOME +)
Modbus gate (HRQ-MODBUS),
HRQ-MODBUS gate, which allows to control the device using the universal modbus
protocol and RS485 data transmission.
NOTE! Controller is not included in the kit. During purchase, choose the
controller that is right for you. Multiple controllers can be connected at
once – e.g. 4-button controller and an Internet gateway.
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
757
Equipment & accessories
Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors
Control options table:
Model
Photo
HRQ-SW3-I
Communication with unit
cable
Power supply
230V
No of modes
AUTO mode*
Display
Calendar
Dirty filter signalization
Changing speed settings
3
no
no
no
no
no
HRQ-BUT-LM11
wireless
battery
4
no
no
no
yes
no
HRQ-BUT-LM04
wireless
battery
4
yes
no
no
yes
no
HRQ-BUT-LCD
wireless
230 V
7
yes
yes
yes
yes
yes
HRQ-GATE
wireless
230 V
6
yes
yes
no
yes
no
HRQ-SENS-CO2 HRQ-SENS-I-CO2
wireless
230 V
5
yes
no
no
yes
no
HRQ-SENS-RH
wireless
battery
4
yes
no
no
yes
no
HRQ-MODBUS
wireless
230 V
–
–
–
–
–
–
HRQ-MODBUS
wireless
n/d
7
yes
no
no
yes
no
- requires at least 1 CO2 or RH sensor
758
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors
Constant Flow (CF)
SlimAIR air handling units optionally can be equipped with the Constant Flow
system, whose task is to maintain a constant air flow in the installation. CF
works by reading the difference between the dynamic pressure around the fan
and the static pressure in the duct in front of the fan. The CF system
constantly monitors the pressure in the ducts and if the resistance increases,
it increases the speed of the fans to maintain a constant flow, such as on the
first day when the ventilation unit was commissioned. During exploitation, the
installation pressure is naturally disrupted (dirty filters, condensation of
water in the heat exchanger, temperature difference changing the air mass). CF
counteracts to those changes, thanks to which the airflows remain sustainable,
and only a sustainable system takes full advantage of the air handling unit’s
capabilities.
Zoning
HRQ-2ZONE is a device designed for residential ventilation systems, dividing
the air supply into two controlled and monitored zones. The air flow is
controlled by motorized dampers, which are adjusted according to the demand
sent by CO2 sensors installed in each zone. Such a system allows for the
detection of the habitant’s presence and provides the right amount of fresh
air in the right place at the right time.
Connecting the ground heat exchanger
Heat recovery unit has a possibility to connect the ground heat exchanger.
This function allows you to control a valve that optionally supply air through
the ground-to-air heating system. To do this, install a dedicated damper with
the actuator (DATVTML).
Demand Control Ventilation, DCV
The AUTO mode is the most energy-efficient and demand driven mode of SlimAIR units. Operation in the AUTO mode is possible when at least one carbon dioxide CO2 or relative humidity RH sensor operates in the system. In AUTO mode, the sensor (or several sensors) generates the so-called ventilation demand based on ambient air measurements. This request is sent wirelessly to the control board, which sets the efficiency of the fans in the range defined by AWAY and HOME(+ offset) speeds. It means, that in the case of factory settings, the range will be 15-70%. The RH sensor will guard against excessive moisture. If there is a sudden increase in relative humidity (more than 3% within 24 seconds) or the reading exceeds 85%, the sesnor will send 100% demand to the control panel to effectively and quickly reduce the RH level. The CO2 sensor will keep the carbon dioxide concentration below the specified level (the factory default is 800 ppm, you can choose between 700,800,900,1000 and 1100 ppm) thanks to the proportional PID algorithm. This means that the request sent to the control board will change gradually over time until the CO2 concentration decreases. HRU-PremAIR-SENS-C02 sensors have 2 AUTO modes: Comfort and Eco. Comfort is the basic setting (i.e. 800 ppm by default), while Eco increases the limit by 250 (i.e. 1050 by default).
The CO2 sensor is available in the following versions:
surface
flush-mounted
HRQ-SENS-CO
HRQ-SENS-I-CO2
In case of having several sensors, the unit control board will operate according to the highest indication (highest request). In the absence of any demand from the sensors, the ventilation unit will run at AWAY speed (lowest setting).
Cooperation with the kitchen hood
The cooker hood can be connected to the MVHR system via the X25 contact on the
main board of the SlimAIR heat recovery units. It is a potential-free contact.
Short-circuits of contact inputs will result in an exhaust fan stopping
completely during the period the contact is closed.
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
759
Equipment & accessories
Heat Recovery Unit PremAIR, SlimAIR and MinistAIR
Controllers and sensors
Mobile application PremAIR
Mobile application for controlling a home ventilation unit HRU-SlimAIR, HRU-
PremAIR and HRU-MinistAIR by ALNOR. It allows to monitor and control the unit
via local network and Internet as well:
· Mode selection (Away, Home, Party, Boost, Auto and Standby)
· Temperature readouts · Registering and displaying remote CO2 and RH sensors
readouts · Fans efficiencies · Defrost mode · By-pass mode · Filters
conditions
Available for download in Google Play and App Store: PremAIR Also via web
browser: https://premair.alnor.pl/
Screen shot:
760
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Equipment & accessories Cinienie calkowite [Pa] Total pressure [Pa]
Air flow and efficiency
HRU-SlimAIR-250-H
400
350
300
250
200
high
150
med.
100
SUPPLY
max
EXHAUST
cinienie calkowite [Pa] Total pressure [Pa] cinienie [Pa]
400
350
HRU-SlimAIR-250E-H
400
300
350
320500
225000 200 med
150
150
110000
high
high med.
max
SUPPLY
max
EXHAUST
400 350 300 250 200 150 100
Cinienie calkowite [Pa]
50
300
50 low
0
0
50
100
150
200
250
300
PrzAepirlywflopowwie[tmrza3[/mh3]/h]
50
50
lowlow
50
0
0
0
50
100
150
200
250
300
0 0
50
100
1p50rzeApliyr2w00flpoowwie2t5[r0zma [3m/h330/]0h] 350
400
450
przeplyw [m3/h]
HRU-SlimAIR-350
SUPPLY
400
250m3/h (pmrzaxy 100 Pa)
350
EXHAUST
HRU-SlimAIR-350E
250m3/h (przy 100 Pa)
400 max
350
SUPPLY
EXHAUST
Total pressure [Pa] cinienie [Pa]
Total pressure [Pa] cinienie [Pa]
300
250 high
200 med
150
300 high
250
200 med
150
100
50
low
100
low 50
0
0
50
100
150
200
250
300
350
400
450
Air pflrzeoplwyw [m[3m/h] 3/h]
0
0
50
100
150
200
250
300
350
400
450
Air pflrzeoplyww [m[3m/h] 3/h]
724
HRU-SlimAIR-500 400 400
335500
Total pressure [Pa] Cinienie calkowite [Pa] cinienie [Pa]
300 300
250
high
225000
150 200 100 med 150
50
1000 0 low
50
low 100
SUPPLY
max
EXHAUST
max high med
200
300
400
500
600
Przeplyw powietrza [m3/h] Air flow [m3/h]
ALNOR® ventilation systems 0
0
50
100
150
200
250
300
350
400
450
przeplyw [m3/h]
is a legally protected trademark and technical patent. All rights reserved.
l
Suspended heat recovery unit with la plate heat exchanger
HRU-SlimAIR
Equipment & accessories
Performance curve HRU-SlimAIR-250-H
Efficiency [%] Odzysk [%]
90 88 86 84 82 80 78 76 74 72 70
0
50
100
150
200
250
300
PrzepAlyiwr pfloowwietr[zma [m3/h3/]h]
l
l
l
Performance curve Heat ( )andmoisturl e recovery ( )
HRU-SlimAIR-250E-H 90
EfficOidezynskc [y%[]%]
80 l 70
60
l
l
l
l
50
l
40 l
30 0
50
100
150
200
250
300
PrzepAlyiwr pfloowwiet[rzma 3[m/h3]/h]
EffiOcdizyeskn[c%]y [%]
Performance curve HRU-SlimAIR-350
97 95 93 91 89 87 85 83 81
0
50
100 150 200 250 300 350 400
ll
Air
flow
[m3/h]
l
Performance curve Heat ( )andmoisturl e recovery ( ) HRU-SlimAIR-350E
EfficOidzeyskn[c%]y [%]
94 90 86 l 82 78 74 70 l 66 62
0
l
l
l
l
50
100
150
200
250
300
350
l
Air
flow
[m3/h]
l
Efficiency [%]
l
l
Performance curve HRU-SlimAIR-500
Performance curve Heat ( )andmoisturl e recovery ( ) HRU-SlimAIR-500E
95
93
91
89
87
85
83
81
79
77 0
50
100 150 200 250 300 350 400 450 500 550
Airl flow [m3/h]
EfficiOedzynskc [y%][%]
95 90 85 80 l 75 70 65 60 55 50
0
l
50
100 150 200l 250 300 350 400 450 500 550
Airl flow [m3/h]
l
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
725
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Filters
Pleated panel filter creates a larger media surface area for air filtration and ensures lower pressure drops. The filter is classified as in the ISO Coarse 70% or ISO ePM1 55% according to ISO 16890 standards.
Code
HRQ-SlimAIR-FILT-C70 HRQ-SlimAIR-350-FILT-C70 HRQ-SlimAIR-500-FILT-C70
Filter clas
ISO Coarse 70% ISO Coarse 70% ISO Coarse 70%
Dimensions [mm] 170x334x23 220x314x23 218x432x23
HRQ-SlimAIR-FILT-ePM155 HRQ-SlimAIR-350-FILT-ePM155 HRQ-SlimAIR-500-FILT- ePM155
ISO ePM1 55% ISO ePM1 55% ISO ePM1 55%
170x334x23 220x314x23 218x432x23
Filter replacement: bottom access
side access
726
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Smart ventilation system SmartAIR
SmartAIR heat recovery system with zoning is the most intelligent, efficient
system on the market. Why is it intelligent? The ventilation system works
independently, based on readings from sensors. Besides knowing how many people
are in the house, the system also knows where they are. Thus, it provides the
right amount of air at the right time and place. A situation like this can be
achieved by zoning, i.e. by dividing the house into day and night zones in
accordance with the natural cycle of the day of the household members.
Find out more about the HRQ-2ZONE
Complete EPP system
Choose thermally insulated EPP ducting. High mechanical strength, pre-
insulated, and quick to assemble. You don’t need an additional insulation
layer. It comes in 15/43mm thicknesses.
EPP manifolds (distribution boxes) Manifolds FLX-PLO-EPP-R are designed for
use in domestic mechanical ventilation systems. They collect 75mm semirigid
ducting, which is then distributed to the rooms. Typical installations contain
from 1 to 2 such manifolds for the supply air and the extract air. Expanded
polypropylene (EPP), the material used for the manifolds, is also an
insulating material.
Duct and fittings made of EPP in thickness 15 or 43 mm.
Check the elements of the EPP System?
Duct-mounted humidifier
The adiabatic humidifier is designed for domestic mechanical ventilation systems with a maximum airflow 600 m3/h. Filtered water naturally evaporates on a special matrix, and then the humidified air is distributed to the ventilation duct system and to the connected rooms. The humidification process is regulated by a wireless room controller and a duct sensor. Built-in PTC heater compensates for temperature losses caused by the evaporation process. The housing is made of EPP, while the matrix is made of fiber glass.
Find out more about duct humidifier
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
727
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Ecodesign Data
Energy class
Model
Sound power
level LWA dB(A)* [dB]
HRU-SlimAIR-250-H
50
HRU-SlimAIR-250-H-CF
50
HRU-SlimAIR-250E-H
50
HRU-SlimAIR-250E-H-CF
50
HRU-SlimAIR-350
49
HRU-SlimAIR-350-CF
49
HRU-SlimAIR-350E
49
HRU-SlimAIR-350E-CF
49
HRU-SlimAIR-500
51
HRU-SlimAIR-500-CF
51
HRU-SlimAIR-500E
51
HRU-SlimAIR-500E-CF
51
Air flow rate [m3/h] 250 250 250 250 350 350 350 350 500 500 500 500
Manual control
A A A A A A A A A A B B
Clock control
A A A A A A A A A A A A
Energy class
Central demand control (1 sensor)
A A A A A A A A A A A A
Local demand control (2 sensor)
A+ A+ A A A+ A+ A A A+ A+ A A
HRU-SlimAIR-250-H-CF
A+
HRU-SlimAIR-350-CF
A+
HRU-SlimAIR-500-CF
A+
50
250 m3/h
dB
49
350 m3/h
dB
51
500 m3/h
dB
ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI
2018
1254/2014
ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI
2018
1254/2014
ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI
2018
1254/2014
728
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-250-H
HRU-SlimAIR-250-H
HRU-SlimAIR-250-H
HRU-SlimAIR-250-H
HRU-SlimAIR-250-H-CF HRU-SlimAIR-250-H-CF HRU-SlimAIR-250-H-CF HRU- SlimAIR-250-H-CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-73.63 -36.71 -12.93 -74.79 -37.64 -13.73 -76.99 -39.39 -15.22 -80.98 -42.46 -17.77
(cold, average, warm climate)
SEC class
A+
A
E
A+
A
E
A+
A
E
A+
A+
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
85.00%
85.00%
85.00%
85.00%
Maximum flow rate [m3/h]2
250
250
250
250
Maxium electric power input [W]
91.5
91.5
91.5
91.5
Sound power LWA [dB(A)]
50
50
50
50
Reference flow rate [m3/s]3
0.049
0.049
0.049
0.049
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.23
0.23
0.23
0.23
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 1.14% Internal: 2.45%
External: 1.14% Internal: 2.45%
External: 1.14% Internal: 2.45%
External: 1.14% Internal: 2.45%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk
www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
865 328 283 837 300 255 786 249 204 702 165 120
The annual heating saved (AHS) [kWh/a/100m2]
8652 4423 2000 8699 4474 2011 8792 4494 2032 8979 4590 2075
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
729
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H HRU-SlimAIR-250E-H-CF HRU-SlimAIR-250E-H-CF HRU-SlimAIR-250E-H-CF HRU-SlimAIR- 250E-H-CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-68.01 -34.05 -11.96 -69.43 -35.09 -12.79 -72.17 -37.07 -14.34 -77.24 -40.64 -17.04
(cold, average, warm climate)
SEC class
A+
A
E
A+
A
E
A+
A
E
A+
A
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
75.30%
75.30%
75.30%
75.30%
Maximum flow rate [m3/h]2
250
250
250
250
Maxium electric power input [W]
90.3
90.3
90.3
90.3
Sound power LWA [dB(A)]
50
50
50
50
Reference flow rate [m3/s]3
0.049
0.049
0.049
0.049
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.21
0.21
0.21
0.21
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 0.67% Internal: 0.79%
External: 0.67% Internal: 0.79%
External: 0.67% Internal: 0.79%
External: 0.67% Internal: 0.79%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
848 311 266 822 285 240 774 237 192 694 157 112
The annual heating saved (AHS) [kWh/a/100m2]
8047 4114 1860 8124 4153 1878 8278 4232 1914 8586 4389 1985
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
730
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-350 HRU-SlimAIR-350-CF
HRU-SlimAIR-350 HRU-SlimAIR-350-CF
HRU-SlimAIR-350 HRU-SlimAIR-350-CF
HRU-SlimAIR-350 HRU-SlimAIR-350-CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-74.43 -37.32 -13.44 -75.52 -38.20 -14.19 -77.62 -39.85 -15.59 -81.40 -42.76 -18.00
(cold, average, warm climate)
SEC class
A+
A
E
A+
A
E
A+
A
E
A+
A+
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
85.60%
85.60%
85.60%
85.60%
Maximum flow rate [m3/h]2
350
350
350
350
Maxium electric power input [W]
123
123
123
123
Sound power LWA [dB(A)]
49
49
49
49
Reference flow rate [m3/s]3
0.068
0.068
0.068
0.068
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.21
0.21
0.21
0.21
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk
www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
848 311 266 822 285 240 774 237 192 694 157 112
The annual heating saved (AHS) [kWh/a/100m2]
8689 4442 2009 8734 4465 2019 8824 4511 2040 9003 4602 2081
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
731
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-350E
HRU-SlimAIR-350E
HRU-SlimAIR-350E
HRU-SlimAIR-350E
HRU-SlimAIR-350E-CF HRU-SlimAIR-350E-CF HRU-SlimAIR-350E-CF HRU-SlimAIR-350E- CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-68.49 -34.04 -11.67 -69.91 -35.10 -12.54 -72.64 -37.13 -14.16 -77.66 -40.75 -16.97
(cold, average, warm climate)
SEC class
A+
A
E
A+
A
E
A+
A
E
A+
A
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
76.90%
76.90%
76.90%
76.90%
Maximum flow rate [m3/h]2
350
350
350
350
Maxium electric power input [W]
146
146
146
146
Sound power LWA [dB(A)]
49
49
49
49
Reference flow rate [m3/s]3
0.068
0.068
0.068
0.068
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.25
0.25
0.25
0.25
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 0.71% Internal: 2.66%
External: 0.71% Internal: 2.66%
External: 0.71% Internal: 2.66%
External: 0.71% Internal: 2.66%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
868 331 286 840 303 258 789 252 207 703 166 121
The annual heating saved (AHS) [kWh/a/100m2]
8147 4165 1883 8219 4201 1900 83.63 4275 1933 8651 4422 2000
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
732
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-500 HRU-SlimAIR-500-CF
HRU-SlimAIR-500 HRU-SlimAIR-500-CF
HRU-SlimAIR-500 HRU-SlimAIR-500-CF
HRU-SlimAIR-500 HRU-SlimAIR-500-CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-73.54 -36.62 -12.84 -74.71 -37.56 -13.65 -76.93 -39.32 -15.15 -80.95 -42.42 -17.73
(cold, average, warm climate)
SEC class
A+
A
E
A+
A
E
A+
A
E
A+
A+
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
85.00%
85.00%
85.00%
85.00%
Maximum flow rate [m3/h]2
500
500
500
500
Maxium electric power input [W]
207
207
207
207
Sound power LWA [dB(A)]
51
51
51
51
Reference flow rate [m3/s]3
0.097
0.097
0.097
0.097
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.23
0.23
0.23
0.23
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 1.3% Internal: 2.98%
External: 1.3% Internal: 2.98%
External: 1.3% Internal: 2.98%
External: 1.3% Internal: 2.98%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk
www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
868 331 286 840 303 258 789 252 207 703 166 121
The annual heating saved (AHS) [kWh/a/100m2]
8652 4423 2000 8699 4447 2011 8792 4494 2032 8979 4590 2075
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
733
Equipment & accessories
Suspended heat recovery unit with a plate heat exchanger
HRU-SlimAIR
Product fiche, Commission Regulation (EU) No 1253/2014, 1254/2014, Annex
Supplier’s name or trade mark
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
ALNOR Systemy Wentylacji
Model identifier
HRU-SlimAIR-500E
HRU-SlimAIR-500E
HRU-SlimAIR-500E
HRU-SlimAIR-500E
HRU-SlimAIR-500E-CF HRU-SlimAIR-500E-CF HRU-SlimAIR-500E-CF HRU-SlimAIR-500E- CF
Specific energy consuption
(SEC) [kWh/(m2.a)]
-67.02 -33.02 -10.92 -68.54 -34.17 -11.85 -71.46 -36.33 -13.59 -76.83 -40.21 -16.60
(cold, average, warm climate)
SEC class
A+
B
E
A+
A
E
A+
A
E
A+
A
E
Declared typology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Type of drive
Variable
Variable
Variable
Variable
Type of heat recovery system
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency1
75.40%
75.40%
75.40%
75.40%
Maximum flow rate [m3/h]2
500
500
500
500
Maxium electric power input [W]
247
247
247
247
Sound power LWA [dB(A)]
51
51
51
51
Reference flow rate [m3/s]3
0.097
0.097
0.097
0.097
Reference pressure difference [Pa]4
50
50
50
50
SPI [W/(m3/h)]5
0.25
0.25
0.25
0.25
Control facotr
1
0.95
0.85
0.65
Declared maxiumum leakages6
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
External: 1.18% Internal: 2.74%
Position and description of visual filter warning
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Visual on status LED light on unit and on status LED light on
controller
Internet address for pre-/dis-assemlby instructions
www.ventilation-alnor.co.uk www.ventilation-alnor.co.uk www.ventilation- alnor.co.uk www.ventilation-alnor.co.uk
The annual electricity consumption (AEC) [kWh/a/100m2]
890 353 308 860 323 278 804 267 222 712 175 130
The annual heating saved (AHS) [kWh/a/100m2]
8054 4117 1862 8130 4156 1879 8284 4234 1915 8590 4391 1986
1 According to EN 13141-7:2010 2 According to EN 13141-7:2010 with at pressure diference 100 Pa 3 According to EN 13141-7:2010 at 70% of maximum flow at static pressure diference 50 Pa 4 According to EN 13141-7:2010 5 According to EN 13141-7:2010 at reference point – 70% of maxiumum air flow 6 According to EN 13141-7:2010
734
ALNOR® ventilation systems
is a legally protected trademark and technical patent. All rights reserved.
References
- Systemy wentylacji i rekuperacja - rekuperatory, kanały, kształtki, akcesoria wentylacyjne | Alnor
- Home Ventilation Systems | Alnor
- ALNOR Rekuperator
- Your comfort zone with SMART ventilation | Alnor
- Plenum box for air valve, EPP | Alnor
- Duct humidifier | Alnor
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>