SKG F5 Body Massager Instruction Manual

June 4, 2024
SKG

SKG F5 Body Massager

Product Overview

SKG-F5-Body-Massager-FIG-1

Massage heads

Directions for use

Installation/replacement of massage heads

Choose a massage head and insert it into the round hole at the front end of the fascia gun.

Installation effect

On/OFF & MODE key 

Long press the power button to power on or off the fascia gun.

Intensity switching

After power-on, user can press the power button to switch to intensities 1、2、3 successively.

Heating on/off

Press and hold the key to activate or deactivate the hot compress state.

Hot compress state switching
After power-on, user can press the heating button to switch the temperature, and it can switch three states as below: low temperature, medium temperature and high temperature in turn.

Machine protection state

  1. In the event of machine blockage, the red lamp is normally ON, and the no-load operation is recovered automatically;
  2. In the event of machine blockage, the red lamp is normally ON; if the blockage lasts for 15 seconds, the machine will automatically shut down;
  3. High-temperature protection; when the motor temperature goes above 120°C, the machine automatically shuts down after the red lamp flashes three times; the machine can be turned on and used again after three minutes.

Power indicator

SKG-F5-Body-Massager-FIG-5

Charging

In battery low indication, charge it by connecting one end of the Type-C USB cable to it and the other end with the charger. The power indicator is orange during charging or green after full charging.

Packing list

SKG-F5-Body-Massager-FIG-7

Precautions for hot compress

Warning (hot compress):

  • Low temperature:
    continuous hot compress on the same part for more than 30 minutes may cause low-temperature scalding;

  • Medium temperature:
    continuous hot compress on the same part for more than 10 minutes may cause low-temperature scalding;

  • High temperature:
    continuous hot compress on the same part for more than 1 minute may cause low- temperature scalding;

Use with caution or do not use (hot compress) in any of the following circumstances:

  1. Patients with ulcers, burns or certain skin diseases on the skin surface are strictly prohibited from hot compress;

  2. People with sensitive skin shall be avoided from long-term hot compress, so as to avoid low-temperature scalding;

  3. Patients suffering from hypertension, diabetes, stroke, brain nerve abnormalities and heart, liver and kidney dysfunction, etc., can be subject to hot compress under the guidance of a doctor;

  4. Pregnant women and parturients are prohibited from using this product for hot compress;

  5. Patients with acute purulent inflammation, high fever, unconsciousness, temperature sensory disturbance or poor physical response-ability are prohibited from using the hot compress function;

  6. Patients with bleeding or bleeding tendency are prohibited from using the hot compress function;

  7. Patients with acute soft tissue injuries, such as sprains, strains, contusions and other subcutaneous congestion, shall not be subject to hot compress within 24 to 48 hours;

  8. Women with irregular menstruation, uterine bleeding, etc., can use the hot compress function under
    the guidance of a doctor;

  9. The elderly, children and patients who cannot express their wishes freely shall use with caution or cause the hot compress function;

  10. It is forbidden to use hot compress on delicate parts of the face, eyes, genitals, important blood vessels and organs;

  11. It is forbidden to use hot compress at the treatment site of metal grafts and the site of malignant tumor lesions;

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • The appliace must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
  • Do not expose the appliance or battery to excessive temperatures.
  • This appliance contains batteries that are non-replaceable. When the battery is at end of life, the appliance shall be properly disposed of.
  • The appliance has a heated surface. Persons insensitive to heat must be careful when using the appliance.

Contraindications

  • Cancer patients should never use the product.
  • Patients once receiving Kirschner wire fixing operation should never use the product. (Do not use the product on any fractured part).
  • Osteoporosis patients should never use the product.
  • Phlebothrombosis or pulsing patients should never use the product.
  • Hypertension patients should never use the product.
  • Pregnant women should use the product carefully. Do not use the product on parts close to the abdomen.
  • Kidney stone patients should use the product carefully. Do not use the product on parts close to the kidneys
  • Varicosity patients should never use the product.
  • Acute inflammation patients should never use the product.
  • Never use the product to massage the patellas, the tibias, the metatarsal bones, etc.
  • Never use the product to massage spines directly.
  • Never use the product to massage the cervical vertebras directly.
  • Never use the product to massage the facial muscles directly.
  • Never use the product to massage a single part for more than 4 to 5 minutes.

Indications

  • Relaxing after strength conditioning training
  • Rehabilitation training
  • muscular fascia relaxing and soft tissue extensibility improving
  • Myalgia and fascia fatigue
  • Strength conditioning training

Safety instructions

  • To avoid skin damage, it is not suggested to use the product to massage skin surface directly. Place dry and clean clothes or towel on the part to be massaged and then press and move the product gently.
  • Do not use the high-speed mode or the high-pressure mode for the head or any part with bone(s) but use it for soft tissues only while there is neither pain nor discomfort.
  • Frequent high-speed or high-pressure massage on a single part may result in abrasion. In the case of pain or discomfort, stop the massage immediately.
  • Keep fingers, hair or any hairy parts away from the product’s stretching part to avoid pain or injuries.
  • Do not discard or improperly use the product.
  • Do not refit the product.
  • Do not make the product work or charge in an unattended condition.
  • Only adults are supposed to use the product.
  • People with any contraindication should use the product after consulting with a doctor.
  • The device has a heating surface, people who are not sensitive to heat must pay attention to it.

DISPOSAL

Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. This product must not be disposed of together with domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances. By collecting and recycling waste, you help save natural resources, and make sure the product is disposed of in an environmentally friendly and healthy way.

Precautions

  • Before starting the product, make sure there is no obstacle in front of its massage head. If affected by any obstacle, the product will stop for some time and try to get started again after that.
  • The product is not waterproofing. Keep it from water and other liquids.
  • Do not disassemble the product. In the case of abnormal operation due to disassembling, please send it back to us for debugging. All the costs hereby caused shall be borne by you.
  • The motor surface temperature may rise after long-time continuous operation.
  • The product may get damaged and work abnormally in the case of falling or collision. In this case, contact our after-sale service department in time.

Storage and maintenance

  • Put the product in a place unreachable to children and pets.
  • Never put the product close to heat sources (such as stoves or heaters) or in cars on hot days.
  • Store the product in a dry place.
  • To avoid damage to the battery, do not overcharge or over-discharge it.
  • Do not use the product when it is too hot or too cold.

Parameters

Precautions when discarding the product

Please use a rechargeable battery (lithium-ion battery).

Danger

  • Please use a rechargeable battery for the product only.
  • Do not charge a rechargeable battery taken out from the product.
  • To avoid overheating, do not throw the battery into fire.
  • Do not penetrate the battery with a nail, or impact it with an h heavy force or refit it.
  • Do not connect the battery electrodes directly with any metal.
  • Do not store the battery with necklaces, hairpins, etc.
  • Do not charge, use or store the product close to the stove, under blazing sunlight, etc.
  • In any of the circumstances above, the battery may be heated, catch fire, burst, etc.

Warning

  • Put the chargeable battery taken out from the product in a place unreachable to infants and young children to avoid careless swallowing.
  • In the case of careless swallowing, see a doctor at once.
  • In the case of electrolyte leakage, do not contact with bare hands but handle as below:
  • In the case of electrolyte contact with the eyes, the eyes may get blind.
  • Do not rub your eyes with bare hands, flush with clean water and see a doctor at once. In the case of electrolyte contact with other body parts or clothes, there may be skin inflammation or injuries.
  • Flush with clean water and, if necessary, see a doctor at once.
  • The battery can be dismounted only when the product is discarded, otherwise, there may be fire, electric shock, injuries, etc. If repair is needed (excluding the case of battery replacement), consult with the shop from which you bought the product about it.

The lithium-ion battery used by the product is a recyclable and renewable valuable resource. When discarding it, please have it handled by a professional agency that can recycle charge- -able batteries. Before discarding the product, power it off and take the lithium-ion battery out from it following the steps below. The battery is to be disposed of safely.

  1. Disassemble the top housing with help of a professional tool.
  2. pull out the battery terminal from the PCBA.
  3. Use a professional cutter to cut off the bottom housing and then take out the battery.

Recycling of products and its parts

Suggestive instructions for recycling
To protect the environment, the consumer is responsible to separate the discarded product or its parts from household waste and send it (or them) to a qualified recycling station to be disassembled and recycled as specified by the state.

SKG-F5-Body-Massager-FIG-8

Notes:

  1. Any other part of the product, that is not mentioned in the table above, or any homogeneous material of it does not contain any hazardous substance.
  2. Any part of the product, that contains any hazardous substance as described in the table above, and its homogeneous materials all meet the requirements of RoHS Directive 2011/65/EU.

Warranty service

Scope of warranty service :

  • Within one year following the product’s purchase date, the main body used normally fails not due to any human factor
  • The product fails not due to disassembling, refit, adding of any unexpected item or any other human factor
  • Consumers can provide a warranty service proof (formal invoice, receipt or purchase information screenshot)

In either of the following circumstances, we will not provide warranty service :

  • Consumer cannot provide a formal purchase proof
  • The product is damaged due to any human factor or force majeure.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals